USER’S MANUAL
CBF 110/130
CBF 110/130 T/TH/TP
CBF 110/130 LIGHT
CBF 110/130 LIGHT T/TH/TP
Centrifugal ceiling fan
CBF
CONTENTS
Safety requirements .....................................................................................................................................................................2
Purpose ................................................................................................................................................................................................ 4
Delivery Set ....................................................................................................................................................................................... 5
Designation key ............................................................................................................................................................................ 5
Technical data .................................................................................................................................................................................. 6
Design and operating principle ........................................................................................................................................... 7
Mounting and set-up ................................................................................................................................................................ 9
Connection to power mains ................................................................................................................................................. 12
Maintenance .................................................................................................................................................................................... 14
Storage and transportation regulations ........................................................................................................................ 16
Manufacturer’s Warranty ........................................................................................................................................................... 17
Acceptance certificate .............................................................................................................................................................. 17
Seller information ......................................................................................................................................................................... 18
Installation certificate .................................................................................................................................................................. 18
Warranty card ...................................................................................................................................................................................18
This user’s manual is the primary operating document intended for technical, maintenance and operations staff.
The user’s manual contains information regarding the field of application, delivery package, operating principle, and design of the centrifugal
fan CBF fan and all its modifications.
Technical and maintenance staff must have proper theoretical knowledge and practical training specific to ventilation systems as well as the
necessary skills to carry out the work in accordance with labour safety and construction regulations and standards applicable in the respective
territory.
The information provided in the present document is true as at the document preparation.
Due to the continuous product development the company reserves the right to update the technical specifications, design or delivery
package of its products.
No part of the present publication may be reproduced, uploaded or saved in reference-providing information systems or translated into other
languages in any form whatsoever without the company’s prior written consent.
READ AND SAVE THESE INSTRUCTIONS
SAFETY REQUIREMENTS
• Please read the user’s manual carefully prior to installing and operating the unit.
• All user’s manual requirements as well as the provisions of all the applicable local and national construction, electrical, and technical
norms and standards must be observed when installing and operating the unit.
• The warnings contained in the user’s manual must be considered most seriously since they contain vital personal safety information.
• Failure to follow the rules and safety precautions noted in this user’s manual may result in an injury or unit damage.
• After a careful reading of the manual, keep it for the entire service life of the unit.
• While transferring the unit control, the user’s manual must be turned over to the receiving operator.
UNIT INSTALLATION AND OPERATION SAFETY PRECAUTIONS
• Disconnect the unit from power mains prior
to any installation operations.
• The unit must be grounded!
• Unpack the unit with care.
• While installing the unit, follow the safety
regulations specific to the use of electric
tools.
2
vents-us.com
• Do not change the power cable length
at your own discretion. Do not bend the
power cable. Avoid damaging the power
cable. Do not put any foreign objects on the
power cable.
• Do not use damaged equipment or cables
when connecting the unit to power mains.
• Do not lay the power cable of the unit in
close proximity to heating equipment.
• Do not operate the unit outside the
temperature range stated in the user’s
manual. Do not operate the unit in
aggressive or explosive environments.
• Do not touch the unit controls with wet
hands. Do not carry out the installation and
maintenance operations with wet hands.
• Do not allow children to operate the unit.
• Do not store any explosive or highly
flammable substances in close proximity to
the unit.
• Do not open the unit during operation.
• Do not block the air duct when the unit is
switched on.
• Do not wash the unit with water. Protect
the electric parts of the unit against ingress
of water.
• Disconnect the unit from power mains prior
to any technical maintenance.
• When the unit generates unusual sounds,
odour, or emits smoke, disconnect it from
power supply and contact the Seller.
• Do not direct the air flow produced by the
unit towards open flame or ignition sources.
• In case of continuous operation of the unit,
periodically check the security of mounting.
• Do not sit on the unit and avoid placing
foreign objects on it.
THE PRODUCT MUST BE DISPOSED SEPARATELY AT THE END OF ITS SERVICE LIFE.
DO NOT DISPOSE THE UNIT AS UNSORTED MUNICIPAL WASTE.
vents-us.com
• Use the unit only for its intended purpose.
3
PURPOSE
The centrifugal ceiling extract fan CBF is designed for extract ventilation of small to medium-sized premises.
THE UNIT SHOULD NOT BE OPERATED BY CHILDREN OR PERSONS WITH REDUCED
PHYSICAL, MENTAL, OR SENSORY CAPACITIES, OR THOSE WITHOUT THE APPROPRIATE
TRAINING. THE UNIT MUST BE INSTALLED AND CONNECTED ONLY BY PROPERLY
QUALIFIED PERSONNEL AFTER THE APPROPRIATE BRIEFING.
THE CHOICE OF UNIT INSTALLATION LOCATION MUST PREVENT UNAUTHORIZED
ACCESS BY UNATTENDED CHILDREN.
WARNING: NOT SUITABLE FOR USE WITH SOLIDSTATE SPEEDCONTROLS
AVERTISSEMENT : NE CONVIENT PAS A DES REGULATEURS DE VITESSE A SEMI
CONDUCTEURS.
THE UNIT MUST NOT BE OPERATED IN KITCHEN PREMISES.
CBF
CAUTION! FOR GENERAL VENTILATING USE ONLY. DO NOT USE TO EXHAUST
HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS
The unit is rated for continuous operation.
Transported air must not contain any flammable or explosive mixtures, evaporation of chemicals, sticky substances, fibrous materials, coarse
dust, soot and oil particles or environments favourable for the formation of hazardous substances (toxic substances, dust, pathogenic germs).
4
vents-us.com
DELIVERY SET
NAME QUANTITY
Fan 1 pc.
LED lamp (for fans with the Light option) 2 pcs.
Cable gland 1 pc.
Mounting bracket 4 pcs.
Fastening kit 1 pc.
User’s manual 1 pc.
Packing box 1 pc.
DESIGNATION KEY
Ceileo 130 Light TP
Additional options
T : timer
TH : humidity sensor and timer
TP : motion sensor and timer
Basic options
_ : no integrated light
Light : integrated LED light
Rated air capacity (CFM)
Fan series
Ceileo : centrifugal ceiling fan
vents-us.com
5
TECHNICAL DATA
A
E
H
Ød
ØD
L2
L1
B
C
A
E
H
BL1
L2
Ød
ØD
h
C
b
a
h
CBF 110/130 Light
CBF 110/130 Light T/TH/TP
CBF 110/130
CBF 110/130 T/TH/TP
The unit is designed for indoor application at ambient temperature from +34 °F up to +104 °F at max. RF 80 %.
Ingress protection rating against access to hazardous parts and water ingress is IPX4.
The unit design is constantly being improved, so some models may be slightly different from those ones described in this manual.
OVERALL AND CONNECTION DIMENSIONS OF THE FANS
CBF
Ceileo 110/130
Ceileo 110/130 T/TH/TP
Ceileo 110/130 Light
Ceileo 110/130 Light T/TH/TP
MODEL
DIMENSIONS, inch
D D L1 L2 A B C E H H A B
5 7/8” 3 7/8” 3 15/16” 1 3/4” 13” 10 3/16” 10 1/4” 15 9/16” 7 3/8”
11
/
16
- -
5 7/8” 3 7/8” 3 15/16” 1 3/4” 13” 10 3/16” 10 1/4” 15 9/16” 7 3/8” 2 7/6” 8 3/16” 4 13/16”
6
vents-us.com