The HR204 (Fig. 1) and HR205 (Fig. 2) are
whole house ventilation units.
This appliance must be installed in accordance
with the manufacturers’ instructions and the
regulations in force.
Duct systems must be installed in accordance
with CIBSE guides and BRE Digest 398.
Read the instructions fully before installing or
using the appliance.
Warning : The ventilation for any open
flued appliance must always be
considered before siting the extract and
inlet vents, the vents must also be sited
away from other flue terminals, ventilators
etc. on the outside of the dwelling. In
addition there shall be adequate
ventilation of the room when the cooker
hood is used at the same time as
appliances burning gas or other fuel. The
exhaust air duct must not be discharged
into a flue which is used for exhausting
fumes from appliances burning gas or
other fuels. Refer to the relevant current
British Standard Codes of Practice, Part J
of the Building Regulations England and
Wales and Part F of the Building
Standards (Scotland) Regulations.
3
Page 4
1.0 User Information
•HR204
Important:The HR204 is not suitable for
installation above any cooking
appliance.
The HR204 is a mechanical ventilation
with heat recovery (MVHR) unit. The unit
provides continuous extraction of stale air
from the dwelling typically from the
bathroom and from the kitchen. The stale
air passes through the heat exchanger
before being ducted to outside.
Fresh air from the outside is continuously
drawn into the unit and passed through a
filter and then into the heat exchanger. In
the heat exchanger the fresh air is prewarmed and ducted into the dwelling
typically to living rooms/ bedrooms.
•HR205
The HR205 is a mechanical ventilation
with heat recovery (MVHR) unit, designed
solely to operate with the Vent-Axia telescopic
cooker hood. The unit provides continuous
extraction of stale air from the dwelling
typically from the bathroom and the
kitchen. The stale air passes through the
heat exchanger before being ducted to
outside.
Fresh air from the outside is continuously
drawn into the unit, passed through a filter
and then into the heat exchanger. In the
heat exchanger the fresh air is prewarmed and ducted into the dwelling
typically to living rooms/ bedrooms.
When the telescopic hood is extended the
MVHR unit switches automatically to
boost. The hood draws steam and fumes
from cooking through metal filters and
direct to outside.
Important: The cooker hood must
always be fully opened when the cooker
/hob is in use.
Warning: Do not flambé under the
cooker hood
4
Page 5
1.0 User Information
Cleaning the Unit
Warning: Disconnect from mains electrical
supply before cleaning any components.
Note: It is important that any door or
cupboard front covering the MVHR unit is
easily removab le by the user as access for
regular cleaning of the air filters and heat
exchanger is required.
Warning: Failure to clean the cooker hood
and its filters as described below will lead
to a fire risk.
Release hand
fastners
Air inlet
filter pull
out, brush
& vacuum
clean
Warning
Pull forward & remove
the outer case
UP
FRONT
UP
FRONT
Use strap to pull
out heat
exchanger.
WiringService
WHC0006A
The cooker hood and filters should be
checked and cleaned every 3 months.
Fig. 3
1.1 Heat Exchanger - HR204 & HR205
1. Lift off the front door panel by releasing the
two hand screws and lifting upwards.
2. Note how the heat exchanger is fitted and by
using the plastic strap pull forwards to remove.
3. If necessary the heat exchanger can be
washed in warm water using a mild detergent.
Take care not to damage the fins. Re-assemble
in reverse order after thoroughly drying.
1.2 Air Inlet Filter - HR204 & HR205
Fig. 4
1. Lift off the front door panel by releasing the
two hand screws and lifting upwards.
2. Remove the air inlet filter by pulling forwards.
3. Carefully brush and vacuum the filter in a well
ventilated area.
HR205
Remove the cooker hood filters for cleaning
View from below the unit
Fig. 4
Fig. 5
4. Re-assemble in reverse order.
1.3 Cooker Hood Filters - HR205
Fig. 5
1. Rear Filter - To remove the rear filter grip and
pull inwards the grey handles at either side and
slide the filter forwards and downw ards.
2. Front Filter - To remove the front filter grip and
pull inwards the grey handles at either side and
drop the filter downwards.
3. The filters can be washed in a dishwasher or
in warm soapy water. Thoroughly dry the filters
and re-assemble in reverse order.
When the electricity is switched on the external
controls (humidstat or normal/boost switch)
supply electricity to the fans.
On normal running the fans run at the voltage
set during commissioning (80,100,120,140 or
160 volts).
Air is then moved through the unit (see Fig 8) If
the fans become jammed then a thermal trip in
the fan senses temperature rise and breaks the
electrical supply to the motor. This can only be
reset by disconnecting from the mains
supply.
If the external controls call for boost operation
the fans automatically run at 230 volts and
increase the air movement of both exhaust and
inlet air.
• HR205
When the electricity is switched on the unit
checks for continuity across the overheat
thermostat.
Power ON
Normal Operation
Fans run in whole
house mode at 80, 100,
120, 140, or 160 Volts.
Cooker
Hood
Open
Boost Operation
Fans run at 230 Volts.
Cooker
Hood
Closed
Continuous extract
typically from
bathroom/kitchen.
Continuous supplying
of fresh filtered
air typically to
living room/ bedroom.
Lights on the Cooker
Hood can be used.
Increased extract rates,
also extract from
Cooker Hood.
Increased supply to
living room/bedroom.
The fans then run at the voltage set during
commissioning (80,100,120,140 or 160 volts).
Air is then moved through the unit (see Fig 8) If
the fans become jammed then a thermal trip in
the fan senses temperature rise and breaks the
electrical supply to the motor. This can only be
reset by disconnecting from the mains
supply.
If the overheat thermostat senses an elevated
rise in temperature from the cooker/hob it breaks
the electrical supply to the fans. The overheat
thermostat can only be reset by
disconnecting the mains supply to the unit.
In the event of a serious fire at the hob (e.g. chip
pan fire) the in built fire damper will operate
sealing the clean air side of the unit from the fire.
10
Lights on the Cooker
Hood can be used.
WHC0021A
Fig. 10
Page 11
5.0 Installation Requirements
5.1Location
1. The cooker hood MVHR unit is only suitable
for installation above a domestic cooker or
domestic hob. The HR205 must be sited a
minimum of 700 mm above the cooker/hob.
2. The exhaust duct must pass through an
outside wall or roof and discharge to atmosphere
in a suitable position .The clean air inlet duct
must pass through an outside wall or roof and be
suitably positioned to provide an adequate fresh
air supply from atmosphere.
5.2Site requirements
1. For the HR205 a flat vertical area 1332mm
high x 600mm wide is required for installation.
For the HR204 a flat vertical area 692mm high x
562mm wide is required for installation.
Important: The HR204 is not suitable for
installation above any cooking appliance
or with any extraction system servicing
a cooking appliance.
2. Before installation consideration must be
given to the position of the ductwork
connections, the electrical connection and the
condensate pipe connection.
Warning: Please check the information on
the data plate is compatible with local
supply conditions.
3. The installation must be carried out by a
competent person and be in accordance with the
relevant Building regulations (Scotland)
(consolidation), the Local building regulations,
the current I.E.E. Wiring regulations.
Reference should also be made to the BRE
digest 398 and CIBSE guidelines.
Warning: The addition of anything that
may interfere with the normal operation of
the appliance without the express written
permission of Vent-Axia Ltd could
invalidate the appliance warranty and
infringe regulations.
Warning: If the unit is fitted in a room
containing a bath or shower then
reference should be made to the current
I.E.E. Wiring Regulations and Building
Regulations.
11
Page 12
5.0 Installation Requirements
5.3General
1. The MVHR unit has five normal fan speed
settings and one boost setting. The
performance curve chart (Section 3, Fig. 8)
gives the ventilation rates at each fan speed
setting compared to the pressure drop of the
system.
2. The transmission of noise along ducts should
be reduced by fitting noise attenuation ducts
Part No. FS100.
5. 4 Ducting
1. The outside exhaust duct and outside air
intake duct should be sited a minimum of 1
metre apart to minimise the risk of contaminated
air being drawn into the house.
2. The duct work system should be sized and
installed to minimise the pressure loss along it.
Examples of different ducting & fittings
Outside
Wall
RD104WHRD104WH
Terminals
minimum
1m apart
NQT100
IQTB45
0.25m
NQT100
OR
NQT40
NQT100
1m
IQTB90
NQT100
or
NQT40
3. Using larger diameter pipes and keeping the
number of bends and fittings used to a minimum
will reduce the pressure drop and allow the unit
to be set at a lower fan speed.
4. Ducting should be insulated in cold areas to
minimise heat losses. All duct joints should be
suitably taped to ensure an air tight seal.
RD060
RD015
1.5m
EV100
Bathroom
RD015
RD060
RD015
SV100
Living
Room
Fig. 13
12
1m
IQTB45
IFD100
HR205
Fresh air in
Exhaust out
RD070
Warm air out
Hot stale air in
WHC0010A
Page 13
5.0 Installation Requirements
Warning : The ventilation for any open
flued appliance must always be
considered before siting the extract and
inlet vents, the vents must also be sited
away from other flue terminals, ventilators
etc. on the outside of the dwelling. In
addition there shall be adequate
ventilation of the room when the cooker
hood is used at the same time as
appliances burning gas or other fuel. The
exhaust air duct must not be discharged
into a flue which is used for exhausting
fumes from appliances burning gas or
other fuels. Refer to the relevant current
British Standard Codes of Practice, Part J
of the Building Regulations England and
Wales and Part F of the Building
Standards (Scotland) Regulations.
5.5System controls
1. An optional Humidistat (HS6) Part No. 370254
is available for automatic boost control.
2. An optional boost switch (NBSW) Part No.
370495 is available for manual/boost control
remote from the unit. An optional pull cord boost
switch (PCSW) Part No. 370278 is available for
manual/boost control remote from the unit.
5.6Electrical supply
1. External wiring must be correctly earthed ,
polarised and in accordance with the current
I.E.E. Regulations.
2. The mains supply must be 230v ~ 50Hz fused
at 3amps
Note: The method of connection to the
mains supply must facilitate complete
electrical isolation of the appliance.
Connection may be via a fused double
pole isolator with a contact separation of
at least 3mm in all poles and supplying the
MVHR unit and its system controls only.
5.7Condensate drain
Fig. 14
1. The condensate pipe should have a
continuous fall of 10° (1 in 6) with as much of the
condensate pipe as possible run inside the
property to avoid freezing. The pipe should also
incorporate a trap with a minimum height of
75mm. See Fig. 17.
2. The HR205 has two alternative condensate
outlet positions: - rear and left hand side
HR204 has three condensate outlet positions: rear, bottom and left hand side.
.
The
13
Page 14
6.0 Installation
Make sure the Wall
Template is level
Mark position
of the
condensate
pipe 15 mm
(drill where
required)
Top of hob
6.1Preparation
1. Check site requirements (Section 5) before
commencing.
ir
rm A
a
t
W
u
O
le
a
t St
o
H
In
ir
A
ir
A
h
es
r
F
In
t
s
u
a
h
x
t
E
u
O
Mark position
of the
fixing holes
2 top (minimum)
& 1 lower
then drill & plug
2. Remove the fixing template from the MVHR
carton.
After considering the site requirements position
the template on the wall ensuring it is level.
3. Mark the positions of at least two top fixing
holes, the lower fixing hole and the condensate
outlet.
Measure 700mm
from hob
If required mark off the positions of the four duct
connections.
4. Drill and plug the wall at the fixing points
and drill the condensate hole.
5. The top two screws should now be fitted
leaving enough space for the keyhole fixing slots
to engage.
6. Place the MVHR unit on its back (Fig. 15). Lift
HR205
off the front door panel by releasing the two
hand screws and lifting upwards.
Mark out the
position of the
unit of the
Wall Template
Part No. 372706
Exhaust
Fresh AirInHot Stale
Out
Bottom of
Mounting
Brackets
4 Fixing Holes
(Key Holes)
Use one
hole each side
MVHR
Side
Minimum Side
Clearance
24mm
(HR205c)
Minimum Side
Clearance
5mm
(HR204)
Back Case
Condensate Hole
Side Case Knock
Out Condensate Hole
Minimum Side
Clearance 1mm
Bottom Condensate
Pipe Exit (HR204 Only)
Minimum
Top
Clearance
200mm
Wall Template HR204 &
HR205
(with cooker hood)
Whole House Ventilation System
Minimum
Side
Clearance
(MVHR)
Minimum
24
Top Clearance
for servicing
200
300
Minimum
Side
Clearance
(MVHR)
24
Minimum
Side
Minimum
Clearance
Front
(C.Hood)
Clearance
1
for servicing
250
Clearances
HR205c
Minimum Bottom
All dimensions
Clearance from Hob
700
Bottom of
Cooker Hood
Cooker Hood
Measure Minimum
Bottom Clearance
700mm
From Hob
(HR205c Model)
Minimum
Clearance
servicing
in mm
Fixing Hole
7. Remove the bottom electrical cover by
releasing the 3 screws, pulling the panel
forwards and disconnecting the earth lead to the
panel.
Warm Air
Air In
Out
98mm
Minimum
Side
Clearance
5
Minimum Top
Clearance
for servicing
280
200
Minimum
Side
Front
Clearance
for
250
Clearances
HR204
Minimum Bottom
Clearance
100
Bottom
Minimum Side
5
Minimum Side
Bottom of
MVHR Unit
Minimum Bottom Clearance
100mm
(HR204 Model)
Top of
MVHR
Unit
MVHR
Clearance
24mm
(HR205c)
Clearance
5mm
(HR204)
Minimum Side
Clearance 1mm
Mains
Cable
Outlet
Side
understairs installation
WHC0013A
Stair Case
Example of a possible
HR204
Fig. 15
14
Ground Floor
Page 15
6.0 Installation
6.2Assembly of the MVHR unit and the
cooker hood - HR205 only.
Remove
the
Cooker
Hood
filters
before
fitting
Cooker
Hood to
MVHR
Unit
View from below the unit
Top View (MVHR Unit
placed on it's back)
Warning
UP
FRONT
Use a
packing
piece to
hold
open
the
cooker
hood
1. Unpack the cooker hood, locate the four
screws and washers and the protective box for
the cooker hood plug and socket.
2. Open out the telescopic hood and remove the
two metal filters by releasing the grey plastic
springs and sliding out.
3. Offer up the hood to the MVHR unit and
carefully feed the cable and four pin cooker hood
socket through the hole in the back right hand
side of the MVHR unit.
4. Align the cooker hood and attach it to the
MVHR unit using the four screws provided.
Note: it will be necessary to support the
telescopic hood when attaching it to the
MVHR unit.
5. Carefully route the cook er hood cable and
socket into the MVHR unit and engage it with the
plug ensuring the locating lugs align.
It is important that the cables are routed away
from the cooker hood outlet and fire damper.
WHC0032A
MVHR
Unit
Connect
Cooker
Hood
Grommet
Secure Cooker Hood to MVHR
Unit with 4 screws supplied
Correct route for cooker hood cable
connection (HR205)
Connector
Clamp the
Protective Box
around the
Connector
Cable
Clips
Grommet
HR205
The cable
must be
routed clear
of the fire
damper
6. Locate the assembled plug and socket in the
protective box taking care to route the cables as
shown (Fig. 16). Clip the bo x together and
secure using the screws provided. Locate the
large cable grommet in the hole and ensure it is
seated correctly.
6.3Condensate outlet
1. If the condensate pipe is to exit the unit at the
left hand side, stand the unit up on its base
taking care not to damage the telescopic hood
and filters.
2. Locate the semi-pierced hole and carefully
remove the metal disc.
3. Swap over the grommet used on the rear exit
hole and seal the rear hole with duct tape or
similar.
Note: The HR204 has an extra condensate
outlet on the bottom panel.
Fig. 16
15
Page 16
6.0 Installation
6.4Fitting the MVHR unit
1. Offer the combined unit to the wall and
engage the keyhole slots over the screws
previously fitted.
2. Make sure the unit is level and tighten the top
screws before engaging the final screw.
6.5Making the condensate connection
1. The condensate connector is suitable for 15
mm pipe.
2. The condensate pipe should incorporate a
water trap to prevent foul air being drawn into the
unit. The minimum height of the trap should be
75 mm.
Note: To ensure the condensate pipe is
primed, slowly pour water into the
condensate tray until it discharges into
the drain.
Fig. 17
16
Page 17
6.0 Installation
6.6Making the duct connections
1. The unit has four duct connections suitable for
100mm plastic pipe.
1. Exhaust outlet to outside
2. Air inlet from outside
3. Stale air inlet from dwelling
4. Fresh air outlet to dwelling
Notes: It is essential that the duct system
is connected as indicated.
It is important that the duct system does
not interfere with the correct fitting of the
outer door and does not prevent the
correct operation of the unit.
6.7Controls
160
140
120
100
80
L
N
Fit bottom cover panel.
Warning
HR205
WiringService
UP
FRONT
Position the white lead
for the required fan speed
setting, (160v fast to 80v slow
available) 120v shown.
WHC0009A
Fig. 18
1. The HR204 requires external controls to
enable normal/boost switching, see Page 20 Wiring Diagrams.
2. The HR205 can have optional external
controls fitted, see Pages 18 and 19 - Wiring
Diagrams.
6.8Making the electrical connection
Warning: This appliance must be earthed
1. The normal running speed of the fans is set at
120v.
2. The unit must be set to the appropriate
voltage as determined by air flow required and
duct system pressure loss (see Section 5.3).
To change the voltage setting for the fans,
unscrew and remove the white wire from the
120v connection on the controller.
3. Carefully insert the wire into the desired
connection (80, 100, 120, 140 or 160) and
secure the wire.
4. Fit the bottom cover panel.
5. Connect the flying lead to the mains supply see Section 5.6.
6. Check the electrical installation for; Earth
continuity, short circuits, resistance to earth and
correct polarity.
17
Page 18
7.0 Wiring Diagrams
HR205 MVHR Unit Wiring
Mains
In
230v
br
b
g/y
Fan
(air out)
r
b
g/y
For
External
Controls
br
b
g/y
r
Overheat Thermostat
1
N
2
L
3
b
4
L
N
gr
gr
Key Colors
b - Blue
gr - Grey
r - Red
w - White
b
bk
w
br
w
b
br
To Cooker Hood
Fan
(air in)
br - Brown
g/y - Green/Yellow
p - Purple
bk - Black
g/y
Controller
w
br
grgr
O
B
C
160
140
b
r
120
100
80
L
g/y
N
b
br
r
b
WHC0031A
bk
br
b
b
L
Fuse (3.15AT)
N
b
Earth for
Inspection
Panel
Fig. 19
b
p
br
boost
speed
230v
b
br
gr
c
Micro Switch
To MVHR
gr
40 watts
bulb
br
Light Switch
HR205 Cooker Hood Wiring
p
bulb
40 watts
br
18
Page 19
7.0 Wiring Diagrams
HR205 MVHR Unit Wiring with optional
Humidstat HS6
Mains
In
230v
(air out)
g/y
br
b
g/y
Fan
r
HS6 Humidistat
Common
0
Boost
2
Ordinary
1
Key Colors
b - Blue
gr - Grey
r - Red
w - White
br - Brown
g/y - Green/Yellow
p - Purple
bk - Black
Fan
(air in)
N
L
Remove Link
1
N
L
2
3
gr
b
gr
4
br
b
g/y
r
b
L
N
gr
br
gr
br
w
br
Overheat
b
Thermostat
bk
w
w
br
b
b
To Cooker Hood
bk
b
b
Controller
O
B
C
L
Fuse (3.15AT)
N
160
140
120
100
80
L
N
r
g/y
Earth for
Inspection
Panel
g/y
b
r
b
br
b
Mains
In
230v
(air out)
g/y
br
b
g/y
Fan
r
HR205 MVHR Unit Wiring with optional
Normal/Boost Switch
Manual Normal /Boost
Switch NBSW or
Pull Switch PCSW
Common
Boost
Remove Link
Normal
1
gr
2
3
b
b
gr
4
br
b
g/y
r
b
L
N
gr
w
br
gr
w
b
br
c
w
br
Overheat
Thermostat
bk
br
b
bk
b
b
To Cooker Hood
Key Colors
b - Blue
gr - Grey
r - Red
w - White
Controller
O
B
C
L
Fuse (3.15AT)
N
br - Brown
g/y - Green/Yellow
p - Purple
bk - Black
160
140
120
100
80
L
N
r
g/y
Earth for
Inspection
Fan
(air in)
g/y
b
r
b
br
WHC0011A
b
Fig. 20
Panel
19
Page 20
7.0 Wiring Diagrams
HR204 MVHR Unit Wiring
Mains
In
230v
br
b
g/y
Fan
(air out)
r
b
g/y
For
External
Controls
br
b
g/y
r
Fan
(air in)
Key Colors
b - Blue
gr - Grey
r - Red
w - White
1
N
2
L
3
b
4
L
N
br
br
b
br - Brown
g/y - Green/Yellow
p - Purple
bk - Black
For
External
Controls
br
b
b
Controller
O
B
C
L
Fuse (3.15AT)
N
160
140
120
100
80
L
N
g/y
g/y
b
r
b
br
r
b
WHC0033A
Earth for
Inspection
Panel
20
Fig. 21
Page 21
7.0 Wiring Diagrams
HR204 MVHR Unit Wiring with optional
Humidstat HS6
Mains
In
230v
(air out)
g/y
br
b
g/y
Fan
r
HS6 Humidistat
Common
0
Boost
2
Ordinary
1
Key Colors
b - Blue
gr - Grey
r - Red
w - White
br - Brown
g/y - Green/Yellow
p - Purple
bk - Black
Fan
(air in)
N
L
1
N
L
br
b
g/y
r
b
2
3
b
4
L
N
br
br
b
br
b
b
Controller
O
B
C
L
Fuse (3.15AT)
N
160
140
120
100
80
L
N
r
g/y
Earth for
Inspection
Panel
g/y
b
r
b
br
b
Mains
In
230v
(air out)
g/y
br
b
g/y
Fan
r
HR204 MVHR Unit Wiring with optional
Manual/Boost Switch
Key Colors
b - Blue
gr - Grey
r - Red
w - White
Manual Normal /Boost
Switch NBSW or
Pull Switch PCSW
Normal
c
1
2
3
b
br
b
g/y
r
b
L
N
4
br
Boost
b
Common
br
br
b
b
Controller
O
B
C
L
Fuse (3.15AT)
N
br - Brown
g/y - Green/Yellow
p - Purple
bk - Black
160
140
120
100
80
L
N
b
br
r
b
g/y
Fan
(air in)
g/y
r
b
WHC0012A
Earth for
Inspection
Panel
Fig. 22
21
Page 22
8.0 Commissioning
8.1 Prepare for commissioning - HR205
1. Refit the front door panel by hooking it over
the top lip of the appliance and swinging down.
Tighten the two case screws.
2. Ensure the telescopic hood is retracted.
3. Turn on the electrical supply. The unit will now
start running at the normal ventilation speed.
4. Pull the telescopic hood forward. The unit will
now switch to boost speed.
5. Check the operation of the cooker hood lights.
8.1a Prepare for commissioning - HR204
1. Refit the front door panel by hooking it over
the top lip of the appliance and swinging down.
Tighten the two case screws.
2. Check the external controls are set to normal
running.
3. Turn on the electrical supply. The unit will now
start running at the normal ventilation speed.
4. Set the external control to boost. The unit will
now switch to boost speed.
22
Page 23
8.0 Commissioning
8.2Balancing the system
Inside View of
Supply V alve
Air direction
SV100
Adjust Ceiling Supply Valve for Living Room etc
Air Deflector
Plate
Locking Nut
to lock
the valve
in position
Air
Direction
Indictor
Note: It is important that a suitable
anemometer is used to balance the
system therefore giving the required
ventilation rates to each room.
1. Set the appliance running on normal speed.
2. Make a preliminary adjustment of all the duct
inlet and outlet louvres.
Note: The supply air terminal is directional
and incorporates a deflector plate. Ensure
that the deflector plate is correctly
positioned so that the active part of the
terminal is discharging to the room.
3. Check the flow rate and adjust if necessary
the extract valve furthest from the appliance.
4. Check the flow rates and adjust if necessary
the remaining extract valves.
5. Repeat the flow checks and adjust until the
extract system is balanced.
6. Check the flow rate and adjust if necessary
the inlet valve furthest from the appliance.
Inside View of
Extract Valve
Locking Nut
to lock
the valve
in position
WHC0029A
7. Check the flow rate and adjust if necessary
the remaining inlet valves.
8. Repeat the checks and adjust until the system
is correctly balanced.
Note: If the flow rates have been achieved
with all the louvres nearly closed, it may
be possible to reduce the fan speed and
re-adjust the louvre settings.
8.3Instruct the user
Instruct the user in the operation of the
appliance. Hand over these instructions, giving
advice on the necessity for regular servicing of
the filters and heat exchanger.
Note: It is important that any door or
cupboard front covering the MVHR unit is
easily removab le by the user as access for
regular cleaning of the air filter and heat
exchanger is required.
EV100
Adjust Ceiling Extract Valve for Bathroom etc
Fig. 23
23
Page 24
Release handand
fastners (Butterfly Bolts)
Air inlet
filter pull
out, brush
& vacuum
clean
Remove
covers
to inspect
Warning
LH/RH
Fans &
Fire
Damper
(clean as
required)
HR205
Pull out & clean the
Condensate Tray
Pull forward & remove
the outer case
UP
FRONT
UP
FRONT
Use strap to pull
out heat
exchanger.
WiringService
Pull Cooker
Hood forward
9.0 Maintenance
Important: Before servicing ensure that
the appliance is isolated from the
electrical supply. After isolating from the
electrical supply, allow one minute for the
fans to stop rotating before servicing the
appliance.
1. HR205 only -Extend the telescopic hood and
remove the two metal filters. The cooker hood
filters can be washed in a dishwasher;
alternatively a hot hand wash will suffice. Check
and clean the filters if necessary. Dry the filters
thoroughly before re-fitting.
2. Lift off the front door panel by releasing the
two hand screws and lifting upwards.
3. Identify the air inlet filter and remove by
pulling forwards.
Taking note of the offset sliders, carefully
remove the heat e xchanger by gently pulling
forwards.
4. Remove the bottom electrical cover by
releasing the 3 screws, pulling the panel
forwards and disconnecting the earth lead to the
panel.
5. Loosen the two screws on each side plate and
lift to remove.
6. HR205 only - Check the cooker hood inlet for
debris and fat deposits. Clean as required.
Check the fire damper is in satisfactory condition
and unaffected by debris and fat deposits.
Replace if necessary.
7. Check both fans, fan compartments and
WHC0016A
exhaust duct outlets for deposits. Clean as
necessary.
8. Remove the condensate tray by pulling
forwards. Check and clean if necessary.
9. Check the condition of the four heat
exchanger sealing strips and front door seal.
Replace all seals as necessary (Fig. 24).
Remove
the cooker
hood
filters
for cleaning
View from
below the
unit
Fig. 24
24
10. Carefully wash the heat exchanger in
warm soapy water taking care not to loosen the
heat exchanger fins. Thoroughly dry the heat
exchanger before re-fitting.
Note: Ensure the heat exchanger is
located correctly in the offset sliders.
11. Carefully vacuum the air inlet filter. Replace if
necessary.
12. Re-assemble in reverse order and re-fit the
outer door ensuring the door makes a good seal.
Page 25
9.0 Maintenance
13. Turn on the electrical supply to the appliance.
With the hood closed the appliance will run on
normal setting. Extend the hood and the
appliance will switch to boost setting. With the
appliance on boost check the operation of the
cooker lights
14. Check the condition of the ductwork system,
the soundness of all joints and repair if
necessary
25
Page 26
10.0 Changing Components
Bulkhead
Controller
Controller
securing
screws (4 off)
160
140
120
100
80
L
N
Warning
Mounting
bracket to
bulkhead
securing
screws (2 off)
Controller
Mounting
Bracket
Rear View of the Controller
Take note of the fan speed setting,
120v shown. When the new controller
is fitted, fit the white lead to the
position of the old controller for the
correct fan speed.
Controller
UP
FRONT
IMPORTANT: ISOLATE FROM THE
ELECTRICAL SUPPLY BEFORE STARTING
ANY WORK ON THE APPLIANCE.
The fans continue to rotate for one minute after
isolating from the electrical supply
10.1 Controller
1. HR205 Only - Fully extend the telescopic
cooker hood and remove the two metal filters.
2. Remove the outer door by releasing the two
screws and lifting the door up and forwards.
3. Remove the bottom electrical cover by
releasing the 3 screws, pulling the panel
forwards and disconnecting the earth lead to the
panel. Make a note of the voltage setting for the
fans and of the wiring arrangement for the
controller.
4. Release all the wires connected to the
controller.
5. Remove R.H. fan cover panel and remove the
R.H. fan (see Section 10.3). Unscrew the two
screws securing the controller mounting bracket
to the bulkhead and remove the bracket and
controller unit. Separate the bracket from
controller by removing the four screws.
6. Re-assemble with the new controller in
reverse order. Check the electrical installation
for; Earth continuity, short circuits,
resistance to earth and correct polarity.
Overheat
Thermostat
Head
Overheat
Thermostat
Fig. 25
26
Sleeve
HR205
Cable
Overheat
Thermostat
Clip
Remove RH fan cover
panel & bottom cover panel.
Tie
Bulkhead
Grommet
WHC0018A
10.2 Overheat thermostat - HR205 Only
1. Lift off the front door panel by releasing the
two hand screws and lifting upwards.
2. Remove the bottom electrical cover by
releasing the 3 screws, pulling the panel
forwards and disconnecting the earth lead to the
panel. Identify the connections for the overheat
thermostat. Make a note of the routing for the
overheat thermostat cable.
3. Release the overheat thermostat connections.
4. Release the sensor head by springing open
the clip and pulling out the sensor head.
5. Remove the overheat thermostat taking care
not to dislodge the bulkhead grommet.
6. Carefully locate the new sensor and position
the lead as shown in Fig. 26. Re-assemble with
the new overheat thermostat in reverse order.
Check the electrical installation for; Earth
continuity, short circuits, resistance to earth
and correct polarity.
Page 27
10.0 Changing Components
10.3 Extract fan and Inlet fan
Removal
of the
Lefthand
Fan
(righthand
fan similiar)
HR205
Slacken
the 2 rear
securing
screws
Fan
capacitor
Cable ties
UP
FRONT
Warning
Remove
LH cover
to access
the LH
Fan
WiringService
Push Fan
Assenbly
to the left
and pull
away from
unit
Fan support
bracket
1. Lift off the front door panel by releasing the
two hand screws and lifting up wards.
2. Loosen the two screws on the side plate and
lift to remove.
3. Release the clip on the plastic plug and
disconnect the plug.
4. Slacken the two rear fan bracket screws.
5. Remove the two front fan bracket screws and
remove the fan assembly.
Note the position of the fan bracket relative to
the fan.
6. Remove the bracket and re-fit to the new fan.
7. Re-assemble with the new fan in reverse
order ensuring the cable does not foul the fan
motor. Check the electrical installation for;
Earth continuity, short circuits, resistance to
earth and correct polarity.
10.4 Fan capacitor
1. Lift off the front door panel by releasing the
two hand screws and lifting up wards.
2. Loosen the two screws on the side plate and
lift to remove.
Spade
terminals
Release
the
electrical plug
Fan securing
screws 4 off
Fan support
bracket
Fan
capacitor
Cable ties
Remove
the 2 front
securing
screws
Fan
3. Release the clip on the plastic plug and
disconnect the plug.
4. Slacken the two rear fan bracket screws.
5. Remove the two front fan bracket screws and
remove the fan assembly.
6. Disconnect the two 2.5 mm spade terminals
from the capacitor.
7. Cut the two cable ties and remove the
capacitor.
8. Re-assemble in reverse order with the new
capacitor and use the new cable ties provided.
Ensure the cable does not foul the fan motor.
Check the electrical installation for; Earth
continuity, short circuits, resistance to earth
and correct polarity.
WHC0020A
Fig. 26
27
Page 28
10.0 Changing Components
10.5 Fire damper - HR205 Only
HR205
Fit 4 new
self-adhesive
sealing strips
(see positions
1 to 4 below)
Fire Damper
U
P
FR
O
N
T
4 Fixing
Screws
Re-fit new
heat
exchanger
1. Fully extend the telescopic cooker hood.
2. Remove the two metal filters.
3. Remove the outer door by releasing the two
screws and lifting the door up and forwards.
4. Remove the bottom electrical cover by
releasing the 3 screws, pulling the panel
forwards and disconnecting the earth lead to the
panel.
5. Remove the four screws that secure the fire
damper and lift it away from the unit.
10.6 Heat exchanger
1. Lift off the front door panel by releasing the
two hand screws and lifting up wards.
2. Gently ease the heat exchanger forwards and
remove.
3. Re-assemble in reverse order taking care not
to damage the heat exchanger seals.
Warning
With the
Cooker Hood
filters removed,
pull off the
old seal and
clean the glue
away.
HR205
2
13
4
10.7 Heat exchanger seals
1. Lift off the front door panel by releasing the
two hand screws and lifting up wards.
2. Gently ease the heat exchanger forwards and
remove.
3. Remove the four heat exchanger seals taking
care to remove all the old adhesive backing.
WiringService
WHC0019A
4. Fit the new seals ensuring they make good
contact with the location channel.
5. Re-assemble in reverse order taking care not
to damage the heat exchanger seals.
10.8 Cooker hood seals
1. Fully extend the cooker hood.
2. Remove the metal filters.
3. Pull away the old cooker hood seal and
remove any remaining glue. Use a small amount
of solvent if necessary.
Adhesive Strip
Peel back adhesive strip &
fit new Cooker Hood Seal
Fig. 27
28
4. Peel back the adhesive strip and carefully fit
the new seal as shown in Fig. 28.
5. Re-assemble in reverse order.
View from below the unit
Page 29
This page is intentionally blank
29
Page 30
11.0 Fault Finding
HR205 - Main Unit Fault Finding Chart
Before starting FAULT FINDING
carry out preliminary electrical systems checks
i.e. Earth Continuity, Polarity, Short Circuit
and Resistance to Earth.
START
Ensure the Cooker
Hood is closed.
Is there
mains voltage
across terminals
A1/A2?
NO
Ensure continuity
between terminals
D5 & A1
and between
D6 & A2.
Check mains
supply.
YES
Is the
fuse on the
controller
O.K.
NO
Investigate cause
and
rectify fault
Replace fuse
3.15AT
WARNING
If the Overheat sensor or Fan
thermal trip has operated,
check the entire system and
unit for correct installation.
Check all ducting outside &
terminals for blockages.
IMPORTANT
When investigating
overheating allow the unit to
run long enough for any fault
to become apparent.
Ensure all external controls are operating
and are set to normal running. Ensure that
a mains electrical supply is available to the
unit.
YES
Is the
voltage across
terminals B1 &
B2 between 80v
& 160v?
NO
Disconnect wires
from terminals
F1, F2 & F3.
Ensure voltage
selector wire is
correctly engaged.
Check external
Is the voltage
across F1 & B2
between 80v
& 160v?
YES
control wiring.
Refer to 205 wiring
diagram (section 7)
Reconnect wires
NO
Replace controller
Replace
cooker hood
YES
Disconnect 4 pin
cooker hood plug.
voltage across
the blue & white
wires on the cooker hood
plug between
NO
Rectify fault on
plug and lead.
YES
to terminals
F1, F2 & F3.
Is the
80v and
160v.
cooker hood
Refer to diagrams below to
identify terminals on components
(e.g. A1, D3 etc).
Are both fans
operating?
YES
NO
See Fan Fault
Finding Chart
Note 1
Electricity supply must be
isolated and Fan Motor
temperature must be less than
100˚ to allow thermal trip to
reset.
Note 2
Electricity supply must be
isolated and Overheat
temperature must be less
than 80˚ to allow Overheat
Thermostat to reset.
30
G
Fan
Plug
C.Hood
Plug
3
2
1
Connector
Block
1
2
3
DE
4
5
6
F
B
Controller
1
O
2
B
C
3
1
L
N
2
Voltage Selector Wire
Fuse
(3.15AT)
1
2
160
140
120
100
C
80
L
A
N
WHC0035A
Page 31
YES
Is there
adequate airflow
at the appliance
inlets and
outlets
NO
Clean filter &
heat exchanger
(section 9). Check
duct system and
terminals for
blockages or
damage. Ensure
terminals are
adjusted correctly.
YES
Does the
appliance switch
to boost when the cooker
hood is opened? (Mains
voltage is present
across terminals
B1 & B2
NO
Disconnect 4 pin
cooker hood plug.
Is the
mains voltage
across the blue &
brown wires on the
cooker hood
plug.
YES
YES
Replace cooker
hood
11.0 Fault Finding
HR205 - Main Unit Fault Finding Chart
Do cooker hood
lights operate?
NO
Are the light
bulbs faulty?
NO
YES
YES
Unit operating
Replace bulbs
satisfactorily
(Max. 40 watts)
Replace bulbs
(Max. 40 watts)
NO
Ensure continuity
across cooker hood
plug and lead.
WHC0036A
31
Page 32
11.0 Fault Finding
HR204 - Main Unit Fault Finding Chart
Before starting FAULT FINDING
carry out preliminary electrical systems checks
i.e. Earth Continuity, Polarity, Short Circuit
and Resistance to Earth.
START
Is there
mains voltage
across terminals
A1/A2?
NO
Ensure continuity
between terminals
D5 & A1
and between
D6 & A2
Check mains
supply.
YES
Is the
fuse on the
controller
O.K.
NO
Investigate cause
and
rectify fault
Replace fuse
3.15AT
WARNING
If the Fan thermal trip
has operated, check the
entire system and unit
for correct installation.
Check all ducting outside &
terminals for blockages.
Ensure all external controls are operating
and are set to normal running. Ensure that
a mains electrical supply is available to the
unit.
YES
Is the
voltage across
terminals B1 &
B2 between 80v
& 160v?
NO
Disconnect wires
from terminals
F1, F2 & F3.
Ensure voltage
selector wire is
correctly engaged.
Check external
Is the voltage
across F1 & B2
between 80v
& 160v?
YES
control wiring.
Refer to 204 wiring
diagram (section 7)
Reconnect wires
to terminals
F1, F2 & F3.
NO
Replace controller
Is there mains
voltage between
F2 and B2
NO
Replace controller
Refer to diagrams below to
identify terminals on components
(e.g. A1, D3 etc).
YES
Are both fans
operating?
NO
See Fan Fault
Finding Chart
YESYES
external controls
have a mains supply
from F2 & reduced
voltage supply
NO
Rectify fault
on wiring to
external control
Do the
from F1
YES
Check
external
control,
rectify or
replace
as
necessary.
IMPORTANT
When investigating
overheating allow the unit to
run long enough for any fault
to become apparent.
Note 1
Electricity supply must be
isolated and Fan Motor
temperature must be less than
100˚ to allow thermal trip to
reset.