EN - Instruction on mounting and use
Refer to the images in the front pages referenced in the text
by alphabet letters.
Closely follow the instructions set out in this manual. All
responsibility, for any damages to property/personnel or
fires caused by not complying with the instructions in this
manual, is declined.
Note: the elements marked with the symbol “(*)” are optional
accessories supplied only with some models or elements to
purchase, not supplied.
Caution
WARNING! Do not connect the appliance to the mains until
the installation is fully complete.
Before any cleaning or maintenance operation, disconnect the
hood from the mains by removing the plug or disconnecting
the mains switch.
The appliance is not intended for use by children or persons
with impaired physical, sensorial or mental faculties, or if
lacking in experience or know-how, unless they are under
supervision or have been trained in the use of the appliance
by a person responsible for their safety.
Children should be monitored to ensure that they do not play
with the appliance.
Never use the hood without
The hood must NEVER be used as a support surface unless
specifically indicated.
The premises must be sufficiently ventilated, when the kitchen
hood is used together with other gas combustion devices or
other fuels.
The extracted air must not be connected into a conduit used
for the disposal of the fumes generated by appliances that
combust gases or other fuels.
The flaming of foods beneath the hood itself is severely
prohibited.
The use of exposed flames is detrimental to the filters and
may cause a fire risk, and must therefore be avoided in all
circumstances.
Any frying must be done with care in order to make sure that
the oil does not overheat and burst into flames.
As regards the technical and safety measures to be adopted
for fume discharging it is important to closely follow the
regulations provided by the authorities.
The hood must be regularly cleaned on both the inside and
outside (AT LEAST ONCE A MONTH, it is in any event
necessary to proceed in accordance with the maintenance
instructions provided in this manual)..
Failure to follow the instructions as concerns hood and filter
cleaning will lead to the risk of fires.
Do not use or leave the hood without the lamp correctly
mounted because of the possible risk of electric shocks.
We decline any responsibility for any problems, damage or
fires caused to the appliance as the result of the nonobservance of the instructions included in this manual.
This appliance is marked according to the European directive
2002/96/EC on Waste Electrical and Electronic Equipment
(WEEE). By ensuring this product is disposed of correctly, you
fitting the grease filters.
will help prevent potential negative consequences for the
environment and human health, which could otherwise be
caused by inappropriate waste handling of this product.
The symbol
on the product, or on the documents
accompanying the product, indicates that this appliance may
not be treated as household waste. Instead it shall be handed
over to the applicable collection point for the recycling of
electrical and electronic equipment. Disposal must be carried
out in accordance with local environmental regulations for
waste disposal.
For more detailed information about treatment, recovery and
recycling of this product, please contact your local city office,
your household waste disposal service or the shop where you
purchased the product.
Installation
The minimum distance between the supporting surface for the
cooking vessels on the hob and the lowest part of the range
hood must be not less than 60cm from electric cookers and
75cm from gas or mixed cookers.
If the instructions for installation for the gas hob specify a
greater distance, this must be adhered to.
Electrical connection
The mains power supply must correspond to the rating
indicated on the plate situated inside the hood. If provided with
a plug connect the hood to a socket in compliance with current
regulations and positioned in an accessible area. If it not fitted
with a plug (direct mains connection) or if the plug is not
located in an accessible area apply a bi-polar switch in
accordance with standards which assures the complete
disconnection of the mains under conditions relating to overcurrent category III, in accordance with installation
instructions.
Warning: Before re-connecting the hood circuit to the mains
supply and checking the efficient function, always check that
the mains cable is correctly assembled.
Mounting
The cooker hood may be installed on the wall or on the base of a
cabinet; if supplied, use the hole gauge H to drill the correct
distance, otherwise lean the cooker hood on the wall or on the
base of the cabinet and mark the holes with a pencil.
Wall mounting - Insert the wall screw anchors J in the drilled
holes and the two K screws in the upper drill holes, remove the
grill and hook the cooker hood to the 2 screws, finally from the
inside, insert the third screw L and lock them all in.
Cabinet fixing - Affix the cooker hood with the 4 M screws from
inside the cabinet.
10

Operation
The hood is fitted with a control panel with speed
selection control and a light switch to control cooking area
lights.
Use the high extract speed in cases of concentrated kitchen
vapours. It is recommended that the cooker hood extraction is
switched on for 5 minutes prior to cooking and to leave in
operation during cooking and for another 15 minutes
approximately after terminating cooking.
Always open the vapour catcher N*.
If your product is provided with an electrically or mechanically
activated valve, the keys and/or the buttons and/or the
handles available are for controlling the lights and for opening
and closing the valve.
Maintenance
ATTENTION! Before performing any maintenance operation,
isolate the hood from the electrical supply by switching off at
the connector and removing the connector fuse.
Or if the appliance has been connected through a plug and
socket, then the plug must be removed from the socket.
Cleaning
The cooker hood should be cleaned regularly (at least with the
same frequency with which you carry out maintenance of the
grease filters) internally and externally. Clean using a cloth
dampened with neutral liquid detergent. Do not use abrasive
products. DO NOT USE ALCOHOL!
Warning:
Failure to carry out the basic cleaning recommendations of the
cooker hood and replacement of the filters may cause fire
risks.
Therefore, we recommend observing these instructions.
The manufacturer declines all responsibility for any damage to
the motor or any fire damage linked to inappropriate
maintenance or failure to observe the above safety
recommendations.
Grease filter
Traps cooking grease particles.
If situated inside the support grill, it may be one of the
following types:
This mode is used if ducted extraction is not possible. The air
Paper filter must be replaced once a month or if colouring
appears on upper side, in such cases the colouring is evident
through the grill openings.
Sponge filter should be washed with hot soapy water once a
month and replaced every 5 to 6 washes.
Metallic filter must be cleaned once a month, with non
abrasive detergents, by hand or in dishwasher on low top grille of the extractor hood.
temperature and short cycle.
When washed in a dishwasher, the grease filter may discolour
slightly, but this does not affect its filtering capacity.
In order to remove the grease filter open the grill via the P hooks
and free the R1 or R2 stoppers.
The self-supporting metal filter does not include a support grill,
in order to remove the filter – pull the release springs P4
backwards and slide the filter downwards.
by the carbon filter before the air is recycled into the room.
When installing and using the hood in this mode ensure there is
Charcoal filter (used for recirculation mode only)
(See notes below for more details)
The saturation of the activated charcoal
occurs after more or less prolonged use,
depending on the type of cooking and the
regularity of cleaning of the grease filter.
In any case it is necessary to replace the cartridge at least
every four mounths.
The carbon filter may NOT be washed or
regenerated.
It may be one of the following types:
Rectangular S1 or S2 or S3:
Mounting (S1 or S2) : insert the rear side T and hook further to
the front (U).
Mounting (S3): Remove the cover W by rotating the O knobs to
90° , then close the cover. Proceed in the inverse for
dismounting.
Circular (V1-V2-V3-various models):
Bayonet mount position the filter in the middle of the motor
protection grill covering ensuring that the reference to X1 or X2 or
X3 on the carbon filter match the Y1 or Y2 references on the
conveyor, then turn clockwise; in case of dismounting turn
anticlockwise, if provided with a Z tape remember to gently lift first.
Replacing lamps
Disconnect the hood from the electricity.
Warning! Prior to touching the light bulbs ensure they are
cooled down.
Replacing lightbulbs 40W - Unscrew the damaged light bulb and
replace with an incandescent oval light bulb with a maximum of
40W E14. Remove the grill in order to reach the light bulb area.
Replacing the halogen bulbs - Access the light compartment –
extract the lamp cover by levering it off with a small screwdriver or
similar tool.
Replace the damaged light bulb. Only use halogen bulbs of 20W
max (G4), making sure you do not touch them with your hands.
Close the lamp cover (it will snap shut).
If the lights do not work, make sure that the lamps are fitted
properly into their housings before you call for technical
assistance.
Recirculation mode.
passes through the grease filter first. Then odours are reduced
Please ensure that the carbon odour filter is fitted in the hood.
always an unobstructed area at least 150mm above the
11

The abc Guarantee
Applicable only to products installed and used in the United Kingdom. For details of guarantee outside the United Kingdom contact your local
Vent-Axia guarantees its products for two years from date of purchase against faulty material or workmanship. In the event of any part being found
to be defective, the product will be repaired, or at the Company’s option replaced, without charge, provided that the product:-
• Has been installed and used in accordance with the instructions given with each unit.
• Has not been connected to an unsuitable electricity supply. (The correct electricity supply voltage is shown on the product rating label
attached to the unit).
• Has not been subjected to misuse, neglect or damage.
• Has not been modified or repaired by any person not authorised by the company.
IF CLAIMING UNDER TERMS OF GUARANTEE
Please return the complete product, carriage paid to your original supplier or nearest Vent-Axia Centre, by post or personal visit. Please ensure
that it is adequately packed and accompanied by a letter clearly marked “Guarantee Claim” stating the nature of the fault and providing evidence of
date and source of purchase.
The guarantee is offered to you as an extra benefit, and does not effect your legal rights
supplier.
220-240V~50Hz
abc
Head Office: Fleming Way, Crawley, West Sussex, RH10 9YX. Tel: 01293 526062 Fax: 01293 551188
UK NATIONAL CALL CENTRE, Newton Road, Crawley, West Sussex, RH10 9JA
SALES ENQUIRIES: Tel: 0844 8560590 Fax: 01293 565169
TECHNICAL SUPPORT: Tel: 0844 8560594 Fax: 01293 539209
Web:-www.vent-axia.com Email:- info@vent-axia.com
As part of the policy of continuous product improvement Vent-Axia reserves the right to alter specifications without notice. 0411
442501B
- 1 -