Installation and Wiring Instructions for the Silent Range Extractor Fans.
Page 2
IMPORTANT: READ THESE INSTRUCTIONS BEFORE COMMENCING
THE INSTALLATION
DO NOT install this product in areas where the following may be present or occur:
• Excessive oil or a grease laden atmosphere.
• Corrosive or flammable gases, liquids or vapours.
• Ambient temperatures higher than 40°C or less than –5°C.
• Possible obstructions which would hinder the access or removal of the Fan.
SAFETY AND GUIDANCE NOTES
A.
All wiring to be in accordance with the current I.E.E. Regulations,
or the appropriate standards of your country and
MUST
be
installed by a suitably qualified person.
B.
The Fan should be provided with a local isolator switch capable of
disconnecting all poles, having a contact separation of at least
3mm.
C.
Ensure that the mains supply (Voltage, Frequency, and Phase)
complies with the rating label.
D.
The Fan should only be used in conjunction with the appropriate
Vent-Axia products.
E.
The Fan should only be used in conjunction with fixed wiring.
F.
When the Fan is used to remove air from a room containing a fuelburning appliance, ensure that the air replacement is adequate for
both the fan and the fuel-burning appliance.
G.
The Fan should not be used where it is liable to be subject to
direct water spray for prolonged periods of time.
H.
Where ducted Fans are used to handle moisture-laden air, a
condensation trap should be fitted. Horizontal ducts should be
arranged to slope slightly downwards away from the Fan.
I.
This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental capabilities, or
lack of experience and knowledge, unless they have been given
supervision or instruction concerning use of the appliance by a
person responsible for their safety.
J.
Children should be supervised to ensure that they do not play with
the appliance.
K.
Stationary appliances not fitted with means for disconnection from
the supply mains having a contact separation in all poles that
Page 3
provide full disconnection under over voltage category III, the
Stock Reference
White
Brown
Wall Fitting Kit
100mm
254102
254100
Window Fitting Kit
100mm
442947
-
Open up the internal cover to access
the spirit level bubble
Spirit level used
only for cosmetic
help. Not
essential for the
normal working of
the fan.
instructions state that means for disconnection must be
incorporated in the fixed wiring in accordance with the wiring rules.
L.
Ensure the grille is fully engaged onto the fan chassis using all
clips.
ACCESSORIES (not supplied)
WALL FITTING KIT
A range of 100mm wall kits are available for installing into most walls using telescopic liners
supplied.
WINDOW FITTING KIT
For use in single or sealed
double glazing and most
materials up to 40mm thick.
INSTALLATION
IMPORTANT: The fan should only be used in conjunction with fixed wiring.
PANEL/CEILING MOUNTING
1. For panel/ceiling mounting the fan should be
installed into a closed duct protected by an
exterior air grille that must comply with the
standard requirements of your country to
prevent access to the fans impeller.
2. Cut a 105mm diameter hole for 100mm fans.
3. Push the two clips on the bottom of the fan
and pull the grille away from the chassis.
4. Using the built in spirit level bubble as an
aid. Mark the screw centres through the
holes in the fan back plate. Drill, plug and
screw into position.
5. After installation, ensure impeller rotates
freely and the shutters can open.
6. Replace the grille and ensure the clips
reactivate.
WALL MOUNTING
1. For wall mounting either cut a 115mm diameter hole for 100mm fans, through the wall and insert the
wall sleeve. Slope the sleeve slightly downwards away from the fan. Cut to length and cement both
ends into position flush with the wall faces.
2. Push the two clips on the bottom of the fan and pull the grille away from the chassis.
3. Using the built in spirit level bubble as an aid. Mark the screw centres through the holes in the fan
back plate. Drill, plug and screw into position. Fix exterior grille into position with the louvres
positioned downwards. (Note:- The grille must comply with the standard requirements of your
country to prevent access to the fans impeller. The wall kit used in this installation should provide a
minimum ducting length of 100mm from the fans back plate to the inside of the external grille).
Page 4
4. After installation, ensure impeller rotates freely and the shutters can open.
5. Replace the grille and ensure the clips reactivate.
WIRING
WARNING: THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED
FROM THE POWER SUPPLY DURING THE INSTALLATION / OR MAINTENANCE.
IMPORTANT
The fan should only be used in conjunction with fixed wiring.
The cross - sectional area of supply cord used should be ranged from 0.75-1.5mm2.
Cable entry can only be made from the rear of the fan.
The extraction fan is suitable for connection to 220-240V 50Hz supply.
The fan is a class ll double insulated product and MUST NOT be earthed.
1. Select and follow the appropriate wiring diagram. (Fig. 1 or 2)
2. Check all connections have been made correctly and ensure all terminal connections are securely
fastened.
3. Ensure the impeller rotates and is free from obstructions.
SETUP
WARNING: THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED
FROM THE POWER SUPPLY DURING THE INSTALLATION / OR MAINTENANCE.
Fig.3: – Grille removal for cable entry and control PCB access.
To remove the inner cover & outer cover, push both
Timer
Adjustment
JP5
Timer Adjustment:
To REDUCE the operating time, use a small screwdriver to
turn the adjuster ANTI-CLOCKWISE.
To INCREASE the operating time, use a small screwdriver to
turn the adjuster CLOCKWISE.
Speed Selection (JP5):
Change the jumper connector to the position shown for the
desired speed
High
Speed
Low
Speed
2
3
1
1
clips (1) to release.
To remove the outer cover, slide the cover to the right
to release the 4 clips (2), then out towards you (3). To
refit the cover, line up the 4 clips on the rear of the
cover and slide to the left until you hear a “click”.
Fig.4: VASF100B , VASF100T
Page 7
Timer Function (JP1)
To activate the timer function remove jumper
JP1.Once removed the fan will run on for a fixed time period
of approx. 15 mins.
Humidity Adjustment
To LOWER the set-point use a small screwdriver to turn the
adjuster ANTI-CLOCKWISE. This makes the controller
MORE sensitive.
To RAISE the set-point use a small screwdriver to turn the
adjuster CLOCKWISE. This makes the controller LESS
sensitive.
Speed selection (JP2).
The fan is factory set to low speed with jumper JP2 fitted.
To activate the high speed setting remove jumper JP2.
Humidity
Adjustment
JP1
JP2
Speed
Adjustment
JP1
JP2
Ambient Response Humidity Function – HTV & HTC only
The inbuilt humidity sensor automatically adjusts dependant on
ambient conditions and does not need adjusting.
Speed Selection
Adjust the fan speed by turning the pot clockwise to increase,
and anti-clockwise to decrease. For continuous running
models, the trickle speed is approximately 50% of the chosen
high speed.
Comfort mode (JP2) – TV, HTV, TC & HTC only
JP2 should be connected to enable comfort mode. (default off).
This feature delays the LS input boost operation for a
maximum of 20 minutes to reduce noise and cold drafts while
bathing. After the LS is disconnected, the fan will switch on for
the same period the LS had been active (up to 20 minutes),
plus the overrun time period if selected (0 or 15 minutes).
Timer Function (JP1) – TV, HTV, TC & HTC only
To activate the timer function remove jumper
JP1.Once removed the fan will run on for a fixed time period of
approx. 15 mins.
Head Office: Fleming Way, Crawley, West Sussex, RH10 9YX. Tel: 01293 526062 Fax: 01293 551188
UK NATIONAL CALL CENTRE, Newton Road, Crawley, West Sussex, RH10 9JA
As part of the policy of continuous product improvement Vent-Axia reserves the right to alter specifications without notice.
494229 B 0819
TheGuarantee
Applicable only to products installed and used in the United Kingdom. For details of guarantee outside the United Kingdom contact your local
supplier.
Vent-Axia guarantees its products for two years from date of purchase against faulty material or workmanship. In the event of any part being found
to be defective, the product will be repaired, or at the Company’s option replaced, without charge, provided that the product:-
Has been installed and used in accordance with the instructions given with each unit.
Has not been connected to an unsuitable electricity supply. (The correct electricity supply voltage is shown on the product rating label
attached to the unit).
Has not been subjected to misuse, neglect or damage.
Has not been modified or repaired by any person not authorised by the company.
IF CLAIMING UNDER TERMS OF GUARANTEE
Please return the complete product, carriage paid to your original supplier or nearest Vent-Axia Centre, by post or personal visit. Please ensure
that it is adequately packed and accompanied by a letter clearly marked “Guarantee Claim” stating the nature of the fault and providing evidence of
date and source of purchase.
The guarantee is offered to you as an extra benefit, and does not effect your legal rights
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.