Vent-A-Hood JCH242A1OLAS Magic Lung Blower Manual

Owner and Maintenance Guide
for Models Equipped with
Magic Lung® Blower
Thank You For Choosing Vent-A-Hood
We know you will be pleased with your purchase decision. Since 1933, our company has earned an outstanding reputation because of our commitment to performance, quality, and reliability.
®
The Importance of Cooking Ventilation
The main purpose of cooking ventilation is to capture the by-products of cooking. These by-products are heat, steam, smoke, odor, hazardous gases, and grease. Without proper cooking ventilation, these by-products can cause a great deal of harm to the home. Vent-A-Hood® range hoods exhaust all cooking by-products to the outside with the exception of GREASE, which is collected by the patented Magic Lung® blower system.
The Magic Lung Blower® - How It Works
The Magic Lung® internal blower system was originally patented in 1937. The Magic Lung® pressurizes grease-laden air as it passes through the blower wheel and cools the grease from a vapor into a liquid. The centrifugal action of the Magic Lung® traps 99% of cooking grease without the use of messy and
ine󰀩cient wire mesh or ba󰀪e lters. The constant speed
centrifugal blower is also designed to create a pressure barrier,
lowering the risk of an attic or wall re.
L023 0320A
Safety
READ AND SAVE THESE INSTRUCTIONS
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING:
A. Use this unit only in the manner intended by the manufacturer.
If you have questions, call the manufacturer.
B. Before servicing or cleaning unit, switch power o󰀨 at service panel
and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
C. Installation work and electrical wiring must be done by qualied
person(s) in accordance with all applicable codes and standards,
including re-related construction.
D. Su󰀩cient air is needed for proper combustion and exhausting
of gases through the ue (chimney) of fuel burning equipment
to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration, and Air Conditioning Engineers (ASHRAE) and the local code authorities.
E. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
F. Ducted fans must always be vented to the outdoors. Do not vent
exhaust air into spaces within walls or ceilings, crawl spaces, attics, or garages.
WARNING - TO REDUCE THE RISK OF A RANGE
TOP GREASE FIRE:
A. Never leave surface units unattended at high settings. Boilovers
cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.
B. Always turn hood ON when cooking at high heat or when
ambeing food (i.e. Crepes Suzette, Cherries Jubilee, Peppercorn
Beef Flambe).
Page 2L023
Safety (Continued)
C. Clean ventilating fans frequently. Grease should not be allowed
to accumulate on fan or in blower housing.
D. Use proper pan size. Always use cookware appropriate for the
size of the surface heating element.
WARNING - TO REDUCE THE RISK OF INJURY TO PERSONS,
IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE
FOLLOWING:
A. SMOTHER FLAMES with a close-tting lid, cookie sheet, or
metal tray, then turn o󰀨 the burner. BE CAREFUL TO PREVENT BURNS. If the ames do not go out immediately, EVACUATE
AND CALL THE FIRE DEPARTMENT.
B. NEVER PICK UP A FLAMING PAN - You may be burned.
C. DO NOT USE WATER, including wet dish cloths or towels - a
violent steam explosion will result.
D. Use an extinguisher ONLY IF:
1) You know you have a Class ABC re extinguisher and you
already know how to operate it.
2) The re is small and contained in the area where it started.
3) The re department is being called.
4) You can ght the re with your back to an exit.
CAUTION
TO REDUCE THE RISK OF FIRE, AND TO PROPERLY EXHAUST
AIR, BE SURE TO DUCT EXHAUST AIR OUTSIDE. DO NOT VENT
EXHAUST AIR INTO SPACES WITHIN WALLS OR CEILINGS, OR
INTO ATTICS, CRAWL SPACES, OR GARAGES.
WARNING
TO REDUCE THE RISK OF FIRE OR ELECTRICAL SHOCK, DO
NOT USE THIS FAN WITH ANY SOLID-STATE SPEED CONTROL
DEVICE.
Page 3 L023
Safety (Continued)
CAUTION
FOR GENERAL VENTILATION USE ONLY. DO NOT USE TO
EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND
VAPORS.
WARNING
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.
THIS MANUAL SHOULD REMAIN WITH THE HOOD
FOR FUTURE REFERENCE
Page 4L023
Operating Instructions (Continued)
A. Models with Dial Controls
On hood models with dial controls, blower assemblies are switched independent from one-another. The user should generally start with the hood on the lowest setting, and then increase speed and/or turn on additional blowers as required.
Blower Control Dial - This switch operates a single or dual blower. To operate the blower(s), rotate the dial through the fan speed settings by turning it clockwise (facing the knob). Rotate the dial counter-
clockwise to turn the blower(s) o󰀨.
Light Control Dial - This switch operates the lights. To operate the lights, rotate the dial through the light intensity settings by turning it clockwise (facing the knob). Rotate the dial counter-clockwise to
turn the lights o󰀨.
Blower Control Dial
T400 Island Cluster Blower Conguration (Top View)
Blower 1 Blower 2
Blower 3 Blower 4
Front Side
Blower Control Dial Light Control Dial Blower Control Dial
Light Control Dial
Blower 1 & 2 Lighting Blower 3 & 4
Page 5 L023