Welcome, 
Thank you for purchasing the Venom Dual 3 Cell AC/DC LiPo Balance 
Charger. Please make sure you read and fully understand the entire 
manual before beginning the charging process. If you read the manual 
and still are unsure how to use this product, please contact our  
Customer Service Department for assistance.
Thank You.
 
 

CONTENTS
FEATURES ......................................................................................
CHARGER OVERVIEW....................................................................
SPECIFICATIONS ...........................................................................
EXTERIOR DESCRIPTION ..............................................................
HOW TO USE YOUR NEW CHARGER ..........................................
WARNINGS & ERROR MESSAGES ...............................................
LiPo BATTERY SAFETY GUIDELINES ..........................................
LiPo BATTERY SAFETY GUIDELINES (CONT.)..............................
WARRANTY & SERVICE INFORMATION .......................................
2
2
3
3
4
5
6
7
8
 
 

FEATURES
CHARGER OVERVIEW
1. Can charge a single 3S battery at 6A or two 3S batteries at 3A each.
2. Begins charging pack upon connection and will stop charging when proper voltage is achieved.
3. User can easily adjust charging amperage based upon pack requirements.
4. Charger can be used as a voltage checker by manually setting the charge current to “0”.
The Venom Dual 3 Cell AC/DC LiPo Balance Charger is an easy to use charger designed to charge one 
or two* 3 cell LiPo and LiFe batteries using an AC or DC input.
*When charging two 3S packs at the same time, the max charge rate will be 3.0A per battery.
PAGE 2
0689
 
 

SPECIFICATIONS
1. Charger Power: 50W
2. Supports 3-cell JST-XH2.5 battery connector (standard balance plug)
3. Current rate range: 0-6.0A
4. Supports simultaneous charging of two 3S packs.
5. Supports AC or DC power: AC 100-240V, DC 10-18V
DC INPUT
BUTTON 1
BATTERY SWITCH
BUTTON 2
CURRENT RATE SET UP
BUTTON 3
MENU SWITCH
BALANCE WIRE CONNECTORS
AC INPUT
LCD SCREEN
PAGE 3
EXTERIOR DESCRIPTION
0689
 
 

How To Use Your Charger
LiPo
NONE
0.0V0.0A
00:00:00
1
3
0.00V
0.00V
0.00V
0.00V
0mAh 
0mAh
0mAh 
0mAh
1
3
---A
---A
---A
---A
2. Choose the correct battery type (LiPo / LiFe) by pressing 
  Button 1. Please refer to your battery charging guidelines.
3. Choose a current rate for your battery using Button 2. 
  Please see top of page 7 for battery charging guidelines.
4. Connect battery, the charger will identify the cell count and 
  begin charging automatically.
Button 1: Switches battery type from LiPo to LiFe
Button 2: Changes the charge rate, 0 Amp - 6 Amp.
        (Set the charge rate within 60 seconds of 
        plugging the battery in).
Button 3: Menu display switches between 4 
   different interfaces:
Interface 1: Total Voltage, current rate/time/charging status.
Interface 1
Interface 2
Interface 3
Interface 4
Interface 2: Individual cell voltages.
Interface 3: Individual cell mAh input.
Interface 4: Individual cell current rate.
1. Use the DC input or AC input to power up the charger.
PAGE 4
0689
 
 

LiPo
PW Err
0.0V0.0A
00:00:00
Charger Warning & Error Messages
LiPo3S
CHGING
12.6V0.3A 
00:01:46
LiPo3S
FULL
12.6V0.3A 
00:16:35
Input Voltage Error:
The charger input voltage must be between 10 and 18 
volts to operate properly. If input voltage is lower or 
higher then you will get a “PW Err” power error.
Charging Status Indication:
“CHGING” will be shown on the left side of Interface 1.
Full Charge Indication:
“FULL” will be shown on the left side of Interface 1 and 
current rate will “0”.
WARNINGS
Please read this manual carefully before use.
Please keep this product away from water, corrosive gasses, dust and wet environments.
PAGE 5
0689
Each battery must be the same chemistry when charging two batteries at the same time!
Incorrect connections may damage the battery, or destroy the charger and void all warranties.
This charger will automatically begin charging within a few moments of the balance 
plug(s) being connected. You MUST set your AMP rate to match the capacity of the 
battery(ies) being charged.
 
 

LiPo Battery Safety Guidelines
PAGE 6
1. Always charge batteries in a fire proof container, in the open and away from flammable materials. Do not charge 
batteries on or near wood, cloth, carpet, in your model, or on or near any other flammable material. Keep a chemical 
fire extinguisher nearby in case of fire.
2. Never leave batteries unattended while charging. Always observe batteries when charging so that you may react 
quickly to any problems that may occur.
3. LiPo cells feature a separate balancing plug that isolates each cell in a pack and charges it independently. This 
ensures that all cells peak equally and discharge at the same rate during use, preventing one or more cells from 
discharging past their safe low voltage cut off rating. The balancing plug can be identified by the multi wire JST XH 
plug.
4. Charge each battery pack individually. Never charge battery packs in series. Charging packs in series may result in 
improper charger cell recognition and an improper charging rate that may lead to overcharging, cell damage and fire.
5. Always check to make sure that your charger settings match those listed on the battery pack label. Refer to the 
battery label for the proper cell count and charging amperage setting. Selecting a cell count or amperage charge rate 
other than the one listed on the battery pack will damage the battery and may cause a fire.
6. Always check battery pack voltage before charging. Do not discharge LiPo batteries below 3.0 Volts per cell. The 
voltage of a typical LiPo cell at rest is 3.7 Volts. If the battery pack appears swollen or damaged, DO NOT CHARGE, 
DISCHARGE, OR USE IN ANY WAY. Please contact the battery manufacturer for further instructions.
0689
 
 

LiPo Battery Safety Guidelines Cont.
PAGE 7
9. For best results do not charge at over 1C current. C= battery pack mAh capacity ÷ 1000. Divide the battery mAh 
capacity by 1000 to determine the proper charge rate. Example: 1200mAh ÷ 1000 = 1.20 Amps Charge Rate for LiPo 
Battery Packs, 
 example: 
  a. 800mAh Capacity = 0.80 Amps 
  b. 1200mAh Capacity = 1.20 Amps 
  c. 2000mAh Capacity = 2.00 Amps
11. If the battery swells or “balloons” or if the battery exceeds temperature guidelines, follow these safety steps: 
  a. Immediately remove the battery pack from your model or charger. 
  b. Place the battery in a non-flammable, well ventilated area. 
  c. Observe the battery for 30 minutes from a safe distance. 
  d. After 30 minutes, if the pack appears stable, is not swollen and does not show any signs of damage,  
    return the battery pack to normal use with caution.
12. If a battery is deformed, swollen or appears damaged, DO NOT CHARGE, DISCHARGE or USE IN ANY WAY. 
Please contact the battery manufacturer for further instructions.
WARNING: CHARGING OR DISCHARGING A DEFORMED, SWOLLEN OR 
DAMAGED BATTERY WILL INCREASE THE RISK OF FIRE AND/OR 
PERSONAL INJURY. 
10. Battery Temperature is critical. For optimum performance in cold climates, warm the pack to 100Fº/ 37Cº before 
use. Please use the following guidelines: 
  a. Charge Temp Range: 32 - 110Fº / 0-43Cº 
  b. Discharge Temp Range: 32 - 140Fº / 0-60Cº 
  c. Storage Temp Ra40 - 80Fº / 4-26Cº
0689
 
 

Warranty & Services
We are so certain of the quality of our chargers that we offer a Venom® Limited Lifetime 
Charger Replacement Plan. Venom
®
 will, at its discretion, repair or replace a defective 
charger free of charge within a period of 1 year from the original date of purchase. Year 
2 onward, any Venom
®
 charger can be exchanged for a brand new charger of the same
model for 30% off original retail pricing.
PAGE 8
0689
 
 

Venom
14028 N. Ohio Street 
Rathdrum, Idaho 83858 USA
Customer Service
For Customer and Warranty Services 
please visit: www.venompower.com 
and click the support tab.