INSTALLATION INSTRUCTIONS
HB0124
VJ71130SS CHIMNEY RANGE HOOD
! !
INTENDED FOR DOMESTIC COOKING ONLY
READ AND SAVE THESE INSTRUCTIONS
INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER.
HOMEOWNER: USE AND CARE INFORMATION ON PAGES 10 AND 11.
Venmar Ventilation Inc., 550 Lemire Blvd., Drummondville QC J2C 7W9 1-800-567-3855
REGISTER YOUR PRODUCT ONLINE AT: www.bnv.ca
For additional information - visit www.venmar.ca
20083 rev. 03
!
WARNING
!
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by
qualified personnel in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment
manufacturer’s guidelines and safety standards such as
those published by the National Fire Protection Association
(NFPA) and the American Society for Heating, Refrigeration
and Air Conditioning Engineers (ASHRAE) and the local code
authorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Do not use this unit with any solid-state speed control device.
8. To reduce the risk of fire, use only metal ductwork.
9. This unit must be grounded.
10. To provide protection against electric shock, connect to
properly grounded outlets only.
11. Never use the glass parts to lift or move the hood. Even after a
low intensity impact, tempered glass can be weakened without
breaking but can experience spontaneous breakage. In the
event of an impact, inspect glass thoroughly; do not handle if
there is any sign of defect. If broken, tempered glass falls out in
interlocking clumps. It can also, on occasion, break into large
shards rather than the classic tiny piece pattern. Tempered
glass surface may be hot.
12. When applicable local regulations comprise more
restrictive installation and/or certification requirements,
the aforementioned requirements prevail on those of this
document and the installer agrees to conform to these at his
own expenses.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings. Boilovers
cause smoking and greasy spillovers that may ignite. Heat oils
slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when
flambeing food (i.e.: Crêpes Suzette, Cherries Jubilee,
Peppercorn Beef Flambé).
c) Clean ventilating fans frequently. Grease should not be allowed
to accumulate on fan, filters or in exhaust ducts.
d) Use proper pan size. Always use cookware appropriate for the
size of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE
EVENT OF A RANGE TOP GREASE FIRE, OBSERVE
THE FOLLOWING*:
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet or
metal tray, then turn off the burner. BE CAREFUL TO PREVENT
BURNS. IF THE FLAMES DO NOT GO OUT IMMEDIATELY,
EVACUATE AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN — You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels —
This could cause a violent steam explosion.
4. Use an extinguisher ONLY if:
A. You own a Class ABC extinguisher and you know how to
operate it.
B. The fire is small and contained in the area where it started.
C. The fire department has been called.
D. You can fight the fire with your back to an exit.
* Based on “Kitchen Fire Safety Tips” published by NFPA.
CAUTION
1. For indoor use only.
2. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
3. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
4. Your hood motor has a thermal overload which will
automatically shut off the motor if it becomes overheated. The
motor will restart when it cools down. If the motor continues to
shut off and restart, have the hood serviced.
5. The minimum hood distance above cooktop must not be less
than 26". For best capture of cooking impurities, the bottom
of the hood should be at a maximum of 30" above cooking
surface. For a gas range, the bottom of the hood MUST NOT
BE LESS than 30" above cooktop.
6. Two installers are recommended because of the large size and
weight of this unit.
7. To reduce the risk of fire and to properly exhaust air, be sure to
duct air outside — Do not exhaust air into spaces within walls
or ceiling or into attics, crawl space or garage.
8. Because of the high exhausting capacity of this unit, you
should make sure enough air is entering the house to replace
exhausted air by opening a window close to or in the kitchen.
9. Please read specification label on product for further
information and requirements.
2
TABLE OF CONTENTS
1. I NSTALL DUCTWORK ..............................................................................................................................................................4
2 MEASURE INSTALLATION ........................................................................................................................................................4
3 PREPARE INSTALLATION .........................................................................................................................................................5
4. W
IRING INSTALLATION ...........................................................................................................................................................5
5. PREPARE HOOD LOCATION .....................................................................................................................................................6
6. INSTALL UPPER FLUE MOUNTING BRACKET .................................................................................................................................6
7. I NSTALL ADAPTER/DAMPER .....................................................................................................................................................6
8 INSTALL HOOD ..................................................................................................................................................................... 7
9. GREASE FILTER ...................................................................................................................................................................8
10. LIGHT BULBS ...................................................................................................................................................................8-9
11. OPERATION ......................................................................................................................................................................10
12. CARE ........................................................................................................................................................................... 11
13. REPLACEMENT PA R TS ......................................................................................................................................................... 12
WARRANTY
VENMAR JAZZ RANGE HOOD
1-YEAR LIMITED WARRANTY
Venmar Ventilation Inc. warrants to the original consumer purchaser of its products, that such products will be free from defects
in materials or workmanship for a period of one (1) year from date of original purchase. This warranty includes in-home service.
THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES
OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. VENMAR VENTILATION INC. WILL NOT BE HELD
RESPONSIBLE FOR ANY CLAIMS OVER THE ORIGINAL PURCHASE PRICE OF A VENMAR JAZZ RANGE HOOD, NOR HELD
RESPONSIBLE FOR SUBSEQUENT DAMAGE OR INCIDENT.
During this one-year period, Venmar Ventilation Inc. will, at its option, repair or replace, without charge, any product or part which is found
to be defective under normal use and service. THIS WARRANTY DOES NOT EXTEND TO BULBS, FUSE, FILTERS, DUCTS, ROOF
CAPS, WALL CAPS AND OTHER ACCESSORIES FOR DUCTING. This warranty does not cover a) normal maintenance and service
b) any products or parts which have been subject to misuse, negligence, accident, improper maintenance or repairs made by other than
Venmar Ventilation Inc., or c) a faulty installation or installation contrary to recommended installation instructions.
Warranty service is to be completed by an authorized Service Center designated by Venmar Ventilation Inc. Where applicable, in-home
service will be made available only in areas where a contracted service provider offers service. If in-home service is not available, the
product will be repaired or replaced, at Venmar Ventilation Inc.’s discretion, by the nearest authorized service provider. The unit removal
and reinstallation works are under the customer responsibility, and Venmar Ventilation Inc. cannot be charged for them.
The duration of any implied warranty is limited to the 1-year period as specified for the express warranty. Some provinces do not allow
limitation on how long an implied warranty lasts, so the above limitation may not apply to you. VENMAR VENTILATION INC. OBLIGATION
TO REPAIR OR REPLACE AT VENMAR VENTILATION INC. OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE
REMEDY UNDER THIS WARRANTY. VENMAR VENTILATION INC. SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL
OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. SOME PROVINCES
DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION
OR EXCLUSION MAY NOT APPLY TO YOU.
This warranty gives you specific legal rights and you may also have other rights, which vary from one province to another. This warranty
supersedes all prior warranties. To contact Venmar Ventilation Inc. Warranty Service call 1-800-567-3855 (in Canada). In order to qualify
for a warranty claim, the owner of a Venmar Jazz range hood must have the model and serial number along with a proof of the original
purchase date. At the time of requesting service, describe the nature of any defect in the product or part.
Venmar Ventilation Inc., 550 Lemire Blvd., Drummondville, Quebec CANADA J2C 7W9
Tel.: 1-800-567-3855 Fax: 819-475-2660
www.venmar.ca
3
1. INSTALL DUCTWORK
WARNING
When performing installation, servicing or cleaning the unit, it is recommended to wear safety glasses and gloves.
ROOF CAP
6" ROUND DUCT
Plan where and how the ductwork will be installed.
A straight, short duct run will allow the hood to perform most efficiently. Long duct
runs, elbows and transitions will reduce the performance of the hood. Use as few
of them as possible. Larger ducting may be required for longer duct runs.
Install wall or roof cap. Connect round metal ductwork to cap and work back
towards the hood location. Use 2" metal foil duct tape to seal the joints.
2. MEASURE INSTALLATION
DECORATIVE FLUE
6" ROUND ELBOW
HOOD
26" MINIMUM ABOVE
COOKING
(30" FOR GAS RANGE)
HH0193A
SURFACE
HOOD
ALL CAP
W
The minimum hood distance above cooktop MUST NOT BE less than 26".
A maximum of 30" above cooktop is highly recommended for best capture
of cooking impurities.
14½" TO
CENTER OF
MOUNTING
HOLES
For a gas range, the bottom of the hood MUST NOT BE LESS than 30"
above cooking surface.
CEILING HEIGHT MIN. HOOD DISTANCE ABOVE COOKTOP MAX. HOOD DISTANCE ABOVE COOKTOP
8 feet 26" 30"
9 feet 30"
10 feet 30"
26" MINIMUM ABOVE
COOKING
SURFACE
(30" FOR GAS RANGE)
Distances over 30" are at the installer and users discretion; providing that ceiling
height permit.
S
TANDARD 36" H.
COOKTOP
HH0194A
4