INSTALLATION AND OWNER GUIDE FOR 40355, 40455 AND VT9W WALL CONTROLS
WARNING
IT IS RECOMMENDED TO WEAR SAFETY GLASSES AND GLOVES WHILE PERFORMING
THESE
INSTRUCTIONS. ALWAYS DISCONNECT THE UNIT BEFORE MAKING ANY
CONNECTIONS. FAILURE TO DISCONNECT POWER COULD RESULT IN ELECTRIC SHOCK OR DAMAGE TO THE WALL CONTROL OR ELECTRONIC MODULE INSIDE THE UNIT.
CAUTION
FAILURE TO COMPLY WITH THE FOLLOWING CAN CAUSE ERRATIC OPERATION OF
THE UNIT AND/OR THE WALL CONTROL:
N
EVER INSTALL MORE THAN ONE X-TOUCH MAIN WALL CONTROL PER UNIT.
MAKE SURE THAT THE WIRES DO NOT SHORT-CIRCUIT BETWEEN THEMSELVES
OR BY TOUCHING ANY OTHER COMPONENTS ON THE WALL CONTROL. AVOID POOR WIRING CONNECTIONS. TO REDUCE ELECTRICAL INTERFERENCE (NOISE) POTENTIAL, DO NOT RUN WALL CONTROL WIRING NEXT TO CONTROL CONTACTORS OR NEAR LIGHT DIMMING CIRCUITS, ELECTRICAL MOTORS, DWELLING/BUILDING POWER OR LIGHTING WIRING, OR POWER DISTRIBUTION PANEL.
WALL CONTROL INSTALLATION
WALL CONTROL COMPATIBILITY
REFER TO THE WALL CONTROL COMPATIBILITY CHART INCLUDED WITH THIS WALL CONTROL.
UNPLUG THE VENTILATION UNIT FROM POWER SOURCE.
CUT A 2 7/8” X 1 3/8” HOLE IN A WALL, AT A CONVENIENT
LOCATION FOR THE WALL CONTROL. ROUTE THE CABLE FROM THE UNIT TO THIS HOLE.
NOTE: DIMENSIONS SHOWN ARE FOR AN INSTALLATION WITHOUT WALL BOX.
TEMPORARILY PLACE THE SWITCH OVER THE HOLE AND MARK
BOTH MOUNTING SCREW HOLE POSITIONS.
REMOVE THE SWITCH, DRILL BOTH SCREW HOLES (3/16” Ø)
IN WALL AND INSERT WALL ANCHORS (INCLUDED).
STRIP THE END OF THE CABLE TO ACCESS THE 4 WIRES.
STRIP THE END OF EACH WIRE. USING A SMALL BLADE SCREWDRIVER, CONNECT EACH WIRE TO ITS CORRESPONDING TERMINAL, ON THE BACK OF THE WALL CONTROL: YELLOW
WIRE TO “Y”, BLACK WIRE TO “B”, RED WIRE TO “R”, AND GREEN WIRE TO “G”.
MOUNT THE WALL CONTROL TO THE WALL.
P
LUG THE VENTILATION UNIT AND TEST THE WALL CONTROL
OPERATION.
VC0167A
Ø 3/16”, t yp.
Y
B
G
R
VE0347
VC0168
WALL CONTROL USE
IF THE BACKLIGHT IS NOT ILLUMINATED, PRESSING ON MODE, % HUM
OR TURBO KEY WILL ACTIVATE IT. T HE BACKLIGHT REMAINS ILLUMINATED FOR 10 SECONDS AFTER THE LAST KEY IS PRESSED (NO MATTER THE KEY).
BACKLIGHT
OR
% HUM
MODE
TURBO
 
OR
WALL CONTROL USE (CONTD)
MODE
PRESS THE MODE KEY TO CHOOSE THE OPERATION MODE OF THE
VENTILATION UNIT (EXCEPT TURBO MODE).
OPERATING MODE WILL THEN APPEAR ON LCD SCREEN (STANDBY, RECIRC, 20 min/h, CONT, SMART).
OPERATING MODES
STANDBY
PUT THE UNIT ON STAND-BY MODE, SO IT WILL ONLY RESPOND TO
OVERRIDE WALL CONTROLS (IF PRESENT). ON LCD SCREEN, ONLY THE HOUSE IS VISIBLE SHOWING THE CONTROL IS POWERED ON.
THIS IS THE FACTORY SET DEFAULT MODE.
RECIRC
AIR IS RECIRCULATED INSIDE THE HOUSE ON HIGH SPEED.
20 MIN/H
THE VENTILATION UNIT EXCHANGES AIR INTERMITTENTLY ON A ONE
HOUR CYCLE AS FOLLOWS: OFF FOR 40 MIN. (OR RECIRCULATION FOR 40 MIN. ON LOW OR HIGH SPEED, SEE BACK PAG E) AND THEN EXCHANGE AIR DURING 20 MIN. ON LOW SPEED. R EPEAT CYCLE AFTER THE 20 MIN. OF AIR EXCHANGE.
CONT
AIR IS EXCHANGED WITH THE OUTDOORS AT THE MINIMUM BLOWER
SPEED.
CONT
SMART
AIR EXCHANGE IS MANAGED ACCORDING TO INDOOR HUMIDITY MEASURED BY THE WALL
CONTROL AND OUTDOOR TEMPERATURE. IN SMART MODE, THE SMART ICON APPEARS AS WELL AS THE CURRENT OPERATING MODE CALLED BY SMART (SEE BELOW).
CONT
TURBO
TURBO MODE
CALLED BY
SMART MODE
CONT MODE
CALLED BY
SMART MODE
20 MIN/H MODE
CALLED BY
SMART MODE
ECO MODE
CALLED BY
SMART MODE
(SEE NOTE)
STANDBY
MODE
CALLED BY
SMART MODE
NOTE: THE ECO MODE SET THE UNIT OPERATION TO STANDBY FOR 50 MINUTES (OR IN RECIRC MODE FOR 50 MINUTES; SEE SETTINGS SECTION) AND THEN EXCHANGE AIR DURING 10 MINUTES ON LOW SPEED. THIS MODE IS EXCLUSIVELY ACTIVATED BY SMART MODE.
T
HE CHART BELOW SHOWS THE OPERATING MODES CALLED BY SMART MODE, ACCORDING
TO
THE INDOOR HUMIDITY PERCENTAGE AND THE OUTDOOR TEMPERATURE.
From -35°C
to -25°C
From -25°C
to -15°C
From -15°C
to -5°C
From -5°C
to 5°C
From 5°C
to 15°C
From 15°C
to 25°C
From 25°C
to 35°C
80%
70%
60%
50%
30%
20%
40%
CONT
TURBO
VG0100A
*
OUTDOOR TEMPERATURE
INDOOR HUMIDITY LEVEL
* THIS AREA REPRESENTS STANBY MODE.
ERROR CODES
ERROR CODES SOLUTION
A 2-DIGIT ERROR
CODE (E1, E2, ETC.) IS DISPLAYED ON WALL CONTROL
SCREEN.
• ENSURE THAT THE COLOR CODED WIRES HAVE BEEN
CONNECTED TO THEIR APPROPRIATE PLACE.
• ENSURE THAT THE WIRES ARE CORRECTLY CONNECTED.
• PRESS AND HOLD SIMULTANEOUSLY FOR 8 SECONDS ON % HUM, MODE AND TURBO KEYS TO RESET THE WALL
CONTROL. THE USER PREFERENCES WILL HAVE TO BE RESET.
A 3-DIGIT ERROR
CODE (E21, E22, ETC.) IS DISPLAYED ON WALL CONTROL
SCREEN.
• PROBLEM WITH THE VENTILATION UNIT. CONTACT YOUR INSTALLATOR.
A 10-
SECOND
COUNTDOWN IS
DISPLAYED ON WALL
CONTROL SCREEN.
• WAIT UNTIL THE END OF THE COUNTDOWN, WITHOUT
PRESSING ANY KEY.
21760 REV. 02
NOTE: I
F THE BACKLIGHT IS NOT ILLUMINATED, PRESS ON ANY KEY TO ACTIVATE THE
WALL CONTROL.
INSTALLATION AND OWNER GUIDE FOR 40355, 40455 AND VT9W WALL CONTROLS
FUNCTIONS
THE TURBO ICON IS FLASHING DURING THE 4-HOUR CYCLE. TO
EXIT THIS FUNCTION BEFORE THE END OF ITS 4-HOUR CYCLE, PRESS ON TURBO OR MODE KEY; THE UNIT WILL GET BACK TO ITS PREVIOUS OPERATION MODE.
TURBO
TURBO FUNCTION
TURBO
PRESS THE TURBO FUNCTION KEY TO TURN THE UNIT ON AIR
EXCHANGE IN HIGH SPEED DURING 4 HOURS, THEN, THE UNIT WILL GET BACK TO ITS PREVIOUS OPERATION MODE.
3 sec.
THE TURBO ICON APPEARS AND STAY CONTINUOUSLY. TO EXIT
THIS TURBO MODE, PRESS ON TURBO OR MODE KEY; THE UNIT WILL GET BACK TO ITS PREVIOUS OPERATION MODE.
P
RESS AND HOLD THE TURBO FUNCTION KEY DURING 3 SECONDS
TO TURN THE UNIT ON AIR EXCHANGE IN HIGH SPEED CONTINUOUSLY.
DEHUMIDISTAT FUNCTION
CONT
THE DEHUMIDISTAT FUNCTION HAS BEEN CREATED TO MANAGE THE
INDOOR RELATIVE HUMIDITY EXCESS. WHEN THE ACTUAL HOME
RELATIVE HUMIDITY PERCENTAGE (RH %) DETECTED IS OVER
THE SET VALUE, DROPS APPEARS ON SCREEN AND THE CONTROL OVERRIDES THE CURRENT MODE, TURNING ON THE UNIT ON HIGH SPEED EXHANGE UNTIL THE INDOOR RELATIVE HUMDITY % SET IS REACHED. THE UNIT THEN RETURNS TO ITS PREVIOUS OPERATION SETTING. REFER BELOW TO FIND OUT HOW TO SET THE INDOOR RELATIVE HUMIDITY %.
TURBO
TURBO
IN ALL MODES EXCEPT
STANDBY AND SMART,
PRESS THE % HUM KEY TO
ENABLE THE DEHUMIDISTAT
FUNCTION.
% HUM
CONT
THE ACTUAL
HOME RH %
LEVEL APPEARS
ON SCREEN
(ENABLED).
HOW TO ENABLE AND DISABLE THE DEHUMIDISTAT FUNCTION:
CONT
PRESS ONCE MORE
ON THE % HUM KEY
TO DISABLE THE
DEHUMIDISTAT
FUNCTION.
T
HE ACTUAL
HOME RH% LEVEL
DISAPPEARS FROM
SCREEN (DISABLED).
% HUM
PRESS AND HOLD
THE % HUM KEY
FOR 3 SECONDS.
3 sec.
THE ACTUAL
RH% LEVEL
APPEARS ON
SCREEN. DEFAULT
VALUE: 44%
PRESS THE % HUM KEY
TO CHANGE THE VALUE.
L
OWER VALUE: 30%.
H
IGHER VALUE: 56%.
THE VALUE CHANGES
BY 2% INCREMENTS.
TO EXIT THIS SETING
MENU, PRESS AND HOLD
THE % HUM KEY FOR
3 SECONDS OR
WAIT 10 SECONDS.
HOW TO SET THE INDOOR RELATIVE HUMIDITY (RH %) LEVEL
% HUM
% HUM
3 sec.
% HUM
SETTINGS
SETTINGS (CONTD)
H
OW TO SET THE UNIT OPERATION IN THE REMAINING 40 MINUTES ON
20 MIN/H MODE AND HOW TO SET THE UNIT DEFROST CYCLE TYPE
PRESS AND HOLD THE MODE KEY
FOR 3 SECONDS.
MODE
3 sec.
THE SMALL TRIANGLE
AND TWO LINES FLASH TO SHOW STANDBY (DEFAULT
CONFIGURATION SETTING).
T
HE LCD SCREEN WILL SHOW ONE OF THESE CONFIGURATIONS:
OR
CONT
RECIRCULATION ARROWS
TURN WHILE THE SMALL
TRIANGLE, rE AND CONT
LABEL FLASH TO SHOW
RECIRCULATION
ON
LOW SPEED.
OR
TURBO
RECIRCULATION ARROWS
TURN WHILE THE SMALL
TRIANGLE, rE AND
TURBO LABEL FLASH TO
SHOW RECIRCULATION
ON HIGH SPEED.
MODE
TURBO
OR
USE MODE OR TURBO KEY TO
SEE ALL 3 CONFIGURATIONS.
% HUM
PRESS % HUM KEY FO ACCEPT
CHOSEN CONFIGURATION AND GO TO SETTING DEFROST CYCLE TYPE.
THE LCD SCREEN WILL SHOW ONE OF THESE DEFROST CYCLE TYPES:
Sd (STANDARD)
APPEARS OVER SNOWFLAKE
ICON (DEFAULT CYCLE
SETTING). WHEN NEEDED,
THE UNIT WILL PERFORM DEFROST CYCLE ON HIGH
SPEED.
NOTE: THIS IS THE DEFROST
TYPE
USED FOR THE DATA
PUBLISHED BY HVI AND
ENERGY STAR®.
OR
PL (PLUS) APPEARS OVER
SNOWFLAKE ICON. USE
THIS CYCLE IN COLD REGION
(OUTDOOR TEMPERATURE
-27°C [-17°F] AND
LOWER). WHEN NEEDED,
THE UNIT WILL PERFORM
DEFROST CYCLE ON HIGH
SPEED ON A LONGER
PERIOD OF TIME.
OR
dI (DISCRETION) APPEARS
OVER SNOWFLAKE ICON.
WHEN NEEDED, THE
DEFROST CYCLE WILL BE PERFORMED ON THE SAME SPEED THAN THE UNIT VENTILATION SPEED. (E.G.: IF THE UNIT IS SET ON
TURBO, THE DEFROST
CYCLE WILL BE DONE ON HIGH SPEED, AND IF THE UNIT IS SET ON CONT, THE DEFROST CYCLE WILL BE DONE ON LOW SPEED.
LCD SCREEN ALTERNATES BETWEEN THE
HOUSE WITH CIRCLED ARROWS AND THE HOUSE WITHOUT ARROW. THE NUMBERS UNDER THE HOUSE ARE THE SOFTWARE VERSION NUMBER.
PRESS % HUM KEY OR
WAIT 10 SECONDS TO EXIT USER SETTING MENU.
MODE
TURBO
OR
USE MODE OR TURBO KEY TO
SEE ALL 3 DEFROST CYCLE TYPES.
% HUM
PRESS % HUM KEY TO ACCEPT
CHOSEN DEFROST CYCLE TYPE AND GO TO SOFTWARE VERSION DISPLAY.
% HUM
PROTECTION MODE
THIS ICON APPEARS TO SHOW WHEN THE VENTILATION
UNIT IS IN PROTECTION MODE. THIS SPECIAL MODE HAS BEEN CREATED TO PROTECT THE VENTILATION UNIT FROM SPECIFIC CONDITIONS (E.G.: OUTDOOR TEMPERATURE
COLDER
THAN -25°C). THERE IS NO ACTION TO BE TAKEN
WHEN THIS ICON APPEARS, IT WILL DISAPPEAR BY ITSELF.
MAINTENANCE INDICATOR
CONT
THIS ICON FLASHES WHEN IT IS TIME TO PEFORM THE
MAINTENANCE. REFER TO THE VENTILATION UNIT USER GUIDE.
O
NCE THE UNIT MAINTENANCE IS DONE, PRESS SIMULTANEOUSLY
ON
BOTH MODE AND TURBO KEYS TO RESET THE
MAINTENANCE INDICATOR. THIS WILL ERASE THE ICON FROM THE SCREEN.
MODE
TURBO
AND