Thank you for purchasing this Velleman High-end valve control amplifier. Please read the instructions carefully so that you can use the unit correctly.
!
WARNING NOTICES
CHECK WHETHER THE MAINS VOLTAGE IS CORRECT FOR THE UNIT.
IN ORDER TO AVOID ELECTRIC SHOCKS,
THE POWER-CORD MUST BE REMOVED BEFORE OPENING THE UNIT .
THE MAINS SWITCH IS IN THE SECONDARY POWER SUPPLY CIRCUIT.
THIS MEANS THAT THE UNIT IS NOT COMPLETELY ISOLATED FROM
MAINS WHEN THE UNIT IS IN STANBY.
About the power cord:
It is possible that in certain countries or regions, the mains plug is different to the one supplied. In such a case a different plug can be fitted, but be careful to ensure that the blue wire is connected to neutral, the brown to live, and the yellow/green to earth. Or ask your dealer for a suitable power cord
Mains voltage: Please check the mains voltage indication at the back of the unit. For 100Vac to 120Vac, use the 115Vac setting For 220Vac to 240Vac, use the 230Vac setting
Guarantee
This product is guaranteed against defects in components and construction from the moment it is purchased and for a period of ONE YEAR starting from the date of sale. This guarantee is only valid if the unit is submitted together with the original purchase invoice. VELLEMAN Ltd limits its responsibility to the reparation of defects or, as VELLEMAN Ltd deems necessary, to the replacement or reparation of defective components. Costs and risks connected to the transport, removal or placement of the product, or any other costs directly or indirectly connected to the repair, will not be reimbursed by VELLEMAN Ltd. VELLEMAN Ltd will not be held responsible for any damages caused by the malfunctioning of a unit.
IMPORTANT: Do not throw away the original packaging. Warranty will be void if the unit is returned in another packaging than the original.
CONTENTS
FEATURES ............................................................................................................................ 4
SPECIFICATIONS ......................................................................................................5
CONNECTION ....................................................................................................................... 6
OPERATION ..............................................................................................................7
TROUBLESHOOTING ...............................................................................................8
3
Features
FEATURES
þ No compromise high-end design þ Four inputs þ Exclusive, high finish, solid aluminium enclosure þ High quality ALPS* volume potentiometer þ Full valve design þ Auto muting (warm up) at power on þ Highly reliable REED relay input selection þ Separate left and right input section þ Programmable level adjustment +6dB for each input þ Regulated DC filament supply þ Output mute function þ Switch-able monitor output (for tape, CDR, MD..) þ Automatic stand-by possibility after 24h
Dia-
Aux CD Tuner A/V
Input selector
V1
Volume
Monitor on/off
Mute
X2 / X4 Amp
© Velleman
Monitor
gram
Line
* ALPS is a trademark of the ALPS ELECTRIC CO. LTD.
4
Specifications
SPECIFICATIONS*
Inputs:
Input sensitivity at x4 gain, for 0dB (0.775Vrms) out (appr.):
AUX: ....................................................................200mV / 50KO
A/V : .....................................................................200mV / 50KO
TUNER: ...............................................................200mV / 50KO
CD: ....................................................................... 200mV / 50KO
Outputs:
Line maximum output level: .................................35Vpp
Line output load impedance: ................................min. 10KO
Monitor output impedance: ..................................> 1KO
Audio specs:
Signal to noise ratio (A-weighted ref. 0dB out):
LINE: .....................................................................100dB
Total harmonic distortion: .....................................<0.04% @1KHz / 47KO
Gain: ....................................................................x2 or x4 (+ 6dB on)
Frequency response @ x2 gain: ..........................7Hz to 150KHz (-3dB)
Frequency response @ x2 gain: .......................... 18Hz to 55KHz within 0.3dB
Channel separation: .............................................85dB @ 0dB in
Input cross talk: ....................................................< -100dB @ 0dB in
Power requirements (depends on version):
AC power: ............................................................115Vac (100V to 120V)
AC power: .............................................................230Vac (220V to 240V)
Consumption: .......................................................16W max.
Dimensions: ......................................................... 290x165x90mm (11.4”x6.5”x3.5”)
Weight (net): ........................................................2.7Kg (6Lbs)
*Modifications and typographical errors reserved
5
Connection
CONNECTION
Connect the amplifier inputs to the different sources. Use good quality audio leads. Respect the Left and Right channels. Connect the output to a suitable ste­reo power amplifier or two mono amplifiers (e.g. our 4020, 4040, or 2x 8010) . Connect the power-cord to the mains connector. Check for correct mains volt­age. Normally the standby/mute LED at the front will be lit (*1).
1.Auxiliary input. Connect any line level (*2) unit to this input.
2.CD input. Connect you CD player or other line level (*2) unit to this input.
3.Tuner input. Use this input to connect your tuner, or other normal line level (*2) unit.
4.Audio/Video audio input. Use this input to connect your audio signal coming from a VCR, DVD, MD, CDR player/recorder...
5.Monitor output, can be used to connect to the audio record input of your tape, VCR, MD, CDR… recorder.
6.Line output. Connect to your power amplifier.
7.Mains connector
8020
Aux
Valve Control Amplifier
Tuner
CD
L
IN
R
Risk of electric shock
Disconnect mains before opening
AV
CAUTION
Monitor
Line
L
OUT
R
!
AC POWER
MAX 16VA
115VAC 230VAC
FUSE 250mA Check voltage setting
(*1) At first time power up, or after a mains voltage failure, the +6dB LED will lit together with the standby/mute LED. (*2) Line level is a source with voltages between 150mV and 2V.
6
and fuse holder, replace only with indicated ratings!
8.Mains volt­age indica-
Operation
OPERATION
CAUTION: Before turning on the power amplifier(s) turn down the volume control.
1.Standby/mute button and indication. Press this button to turn on the unit or to mute the sound. Keep this button pressed to set the unit in standby. After power on, it will take about 30 seconds (warm up) before the muting will be off. The muting button is disabled during this time!
2.Monitor indication. See point 4 for use.
3.+6dB indication. See below for use.
4. Input selection buttons and indication. Press once to select the input. Press a second time to turn on the monitor output. Press and hold the input selection button a second time to turn on the +6dB function for this input. The +6dB will be memorized (*) each time the corresponding input is selected. Selecting an input will also turn on the unit. NOTE: During switchover between input, the sound will be muted for about 3 seconds.
5.Volume control.
8020 Valve Control Amplifier
+6dB Aux CD Tuner
Monitor
AV
FThe +6dB function can be used to adjust the level between the different
sources. That way, when switching over between sources the volume will approximately remain the same.
(*) When the power-cord is disconnected or after a power failure the memory will be erased. Turning on the unit with the input selection buttons will activate a 24h auto standby timer.
7
Troubleshooting
TROUBLESHOOTING Symptom
No sound coming from the speakers
+6dB memory is erased
Hum or noise is coming from the speakers
No button is reacting anymore and/ or no LED indication is functioning anymore
The tape recorder, MD, CDR… is not receiving a signal
Possible cause
Mute is on, press standby/mute but­ton. The power amplifier is turned off. Wrong source is selected
A power failure has occurred. The power-cord has been discon­nected.
To make sure the control amplifier is the source of hum, disconnect all input leads. Use good quality audio leads. Check the earth connection of the phono or mains. The control amplifier is too close to the power amplifier or too close to other magnetic field like a power adapter or other mains operated unit.
Static electricity or lightning can cause malfunction of the unit. Disconnect the power-cord for about 10 seconds, this will reset the inter­nal processor. Check the mains fuse, replace only with indicated rating. A spare fuse is located in the fuse holder.
The monitor function is not en­gaged, press the desired input once again to engage the monitor output.
8
Info en inhoud
Hartelijke dank voor de aanschaf van deze hoogwaardige voorversterker. Lees de gebruiksaanwijzing aandachtig, zodat u het apparaat op de juiste manier gebruikt.
!
CONTROLEER OF DE AANGESLOTEN NETSPANNING, OVEREENKOMT MET HET
ALVORENS HET TOESTEL TE OPENEN MOET MEN HET NETSNOER
VERWIJDEREN, OM ELEKTRISCHE SCHOKKEN TE VERMIJDEN.
DE “AAN/UIT SCHAKELAAR” IS IN HET SECUNDAIRE VOEDINGSCIRCUIT
OPGENOMEN. DIT BETEKENT DAT HET APPARAAT NIET VOLLEDIG VAN HET NET
IS LOSGEKOPPELD ALS HET TOESTEL OP ”STANDBY”’ STAAT.
WAARSCHUWINGEN
TOESTEL
Over het netsnoer:
Het is mogelijk dat in bepaalde landen of gebieden, de uitvoering van de netstekker anders is dan hetgeen bijgeleverd. In dat geval kan men een andere stekker monteren, men moet er echter op letten dat de blauwe geleider met de neutrale aansluiting verbonden wordt, de bruine geleider met de fase en de geel/groene draad met de aarding. Of vraag uw verdeler voor een gepast netsnoer.
Keuze van de netspanning: Zie achterkant van het toestel. Voor 100 tot 120Vac de 115Vac aanduiding Voor 220 tot 240Vac de 230Vac aanduiding
WAARBORG
Dit produkt is gewaarborgd wat betreft gebreken in materialen en vakmanschap op het ogenblik van de aankoop en dit gedurende een periode van EEN JAAR vanaf de aankoop. De waarborg geldt enkel indien het produkt voorgelegd wordt samen met het origineel aankoop bewijs. De verplichtingen van VELLEMAN N.V. beperken zich tot het herstellen van defecten of, naar vrije keuze van VELLEMAN N.V., tot het vervangen of herstellen van defecte onderdelen. Kosten en risico’s van transport; het wegnemen en terugplaatsen van het produkt, evenals om het even welke andere kosten die rechtstreeks of onrechtstreeks verband houden met de herstelling, worden niet door VELLEMAN N.V. vergoed. VELLEMAN N.V. is niet verantwoordelijk voor schade van gelijk welke aard, veroorzaakt door het falen van een product.
BELANGRIJK: Gooi de originele verpakking niet weg, deze kan nodig zijn om het toestel te verpakken bij terugzending. Bij gebruik van een niet originele verpakking, vervalt de waarborg!
INHOUD
KENMERKEN .......................................................................................................................10
SPECIFICATIES ........................................................................................................11
AANSLUITINGEN ................................................................................................................12
BEDIENING ............................................................................................................... 13
TIPS BIJ PROBLEMEN .............................................................................................14
9
Loading...
+ 19 hidden pages