Veimart VM-10 Instructions For Use Manual

THE INDICATOR LIGHTS UP: The
solenoid valve is closed and the plumbing leak test is carried out. The indicator does not light up if the solenoid valve is open.
MAXIMUM TIME = longest allowed time for continuous flow. Resets every time the
the toilet bowl leaks. The water ows only
for the time set with the maximum time setting.
RESET BUTTON’S functions:
1. Resetting the water guard.
2. Resetting an exceeded maximum time (the light blinks together with the maximum time light).
3. Resetting the alarm caused by the leakage sensor attached to the extension unit. (Slowly blinking light – – –).
4. Resetting the alarm caused by lost connection to the solenoid valve (fast blinking light ---).
TIME EXTENSION extends the maximum
time of continuous water ow. This
function is useful e.g. when watering
your lawn, lling the pool or washing
your car. The Veimart unit shuts off the water supply when the maximum time + extended time is over and the water is still running (requires a reset). The setting automatically resets.
IN AWAY MODE the flow of water has been completely stopped. The red indi-
cator is lit. Reset the Veimart unit back to basic (home) mode by pressing the Away button again. The indicator light goes off. The water guard is also on in the Away mode: If there is a leak in the plumbing (even though the water mains has been shut off) there will be no water before you press the reset button.
THE BLUE LIGHT is always on when
the ow sensor detects that water is owing in the piping. This means that the solenoid valve is open. If the ow
is very low, the blue indicator will not light up and the leakage sensor will cut off the water supply.
TIP!
The maximum time
also leads to more
economical water
consumption. Using
too much hot water in
particular can be
expensive.
NOTE!
See our FAQ on our
website to nd answers
to frequently asked
questions
www.veimart.fi/en/faq
WITH THE TEST BUTTON you
can override the 10 minute forced control delay and shut the solenoid valve for a dripping test:
1. Close all taps.
2. Press the test button. This causes the solenoid valve to close (an indicator illuminates above the test button).
3. Open the tap just a little and see whether the Veimart unit
stops the water owing after
a while.
4. Stop the test by pushing the reset button.
NOTE! The solenoid valve stays open for 10 more minutes after the Veimart unit no longer
detects water owing (when the
blue indicator light goes off). This means that the device does not require a reset if the tap is dripping for a few minutes by accident.
VEIMART INSTRUCTIONS FOR USE
THANK YOU FOR CHOOSING THE VEIMART WATER GUARD!
It is extremely easy to use the Veimart water guard. After the simple initial setup, the device is always on. If the tap water plumbing of your house works as it should (no leakage, normal pressure, over 3.5 bar), the Veimart system runs automatically so that you don’t have to pay any attention to it. The device monitors the condition of the plumbing and cuts off the water supply if it detects a leak or if the water is left running for too long.
WHAT TO DO IF THE WATER IS NOT FLOWING (the water guard has been triggered): Find out if a tap is dripping enough for
the Veimart unit to have interpreted it as a leak so that it has stopped the water. Press the reset button and water will ow
normally. If you can’t nd out why the water guard was triggered, see if it happens again after the alarm was resetted. Typically
leaks occur on seals, taps and toilet bowls. The Veimart unit also recognizes dripping leaks if the water is not used for a few hours. The smaller the leak, the longer it takes to detect it. For example one drop every minute is enough to trigger the water guard over-
night. If it is not possible to nd the leak with the naked eye, a professional may be able to nd the leak with pressure test equipment.
www.veimart.fi/en
Visuad032018
Veimart Oy | VAT number: 2712062-7 | Takatie 6 90440 KEMPELE | Customer service +358 44 244 0140 | asiakaspalvelu@veimart.
VEIMART INSTALLATION GUIDE
The insulation casing is opened and closed with metallic clips. The insulation casing prevents condensation caused by the cold water. If there is no room, the insulation casing can be left off.
Turn the bypass valve as shown in the picture so the water runs through the water guard. In case of an electrical failure it is possible to get water if the bypass valve is turned in the same direction as the water pipe. It might also be necessary to bypass the water guard if it requires constant resets and professional help is not available immediately.
WHAT TO DO IMMEDIATELY AFTER INSTALLATION: Since there might be air in the plumbing that can disturb the operation of
the water guard, make sure to run water from all taps long enough for all air to be expelled. Don’t forget any water taps you might have outside.
115
AWAYRESET
HOME
2 m
240
200
160
VMEX-10
VMSW-S
(surface installation)
VM-10 BASIC PACKAGE ACCESSORIES
Leakage sensors can be placed in critical positions, such as below washing machines and manifolds, to detect leaks (this way the system can also detect any leaks in sewer connections). Any alarm caused by the leakage sensor must be resetted before the Veimart unit reopens the valve.
VMSW-S is a surface installed, two-part switch that has one button for resetting alarms (spring return) and another one for the Away function. Can be installed e.g. close to a door in the hall.
WARRANTY: The warranty only covers
repairing the device or delivering a new device to replace a faulty one. The warranty does not cover any direct or indirect damage the device may cause to the customer or the user, nor is the supplier of the device responsible for such damage.
OR
REMOTE CONTROL OF AWAY MODE (e.g. through a home automation system)
ALARM INFORMATION
AWAY - STATUS INFORMATION
VMLS-10
(Cabling of eld devices:
e.g. KLM 4 x 0.8)
SPECIFICATIONS
WATER GUARD
Product code, VM-10
WATER GUARD BODY
Material Brass that can resist
dezincication CB772S
Space needed for installation 160 mm Input terminal 3/4” male thread with gasket Output terminal 22 mm compression coupling Weight 2.75 kg Dimensions 240 x 200 x 115 (with insulation protection), installation direction can be chosen freely
CONTROL UNIT Width x height x depth 130 x 90 x 38 Operating voltage 24 VDC Connecting cable 2 m, plug-in connection
ACCESSORIES Product code Extension cable for the control unit 5 m VMC-5 Extension cable for the control unit 10 m VMC-10 Extension cable for the control unit 20 m VMC-20 Extension unit VMEX-10 Leakage sensor VMLS-10 Switch (surface installation) VMSW-S Water meter connector (incl. one-way valve) VM-3/4UKx1SK
Country of manufacture Finland Warranty 2 years
APPROVALS
EN-55022, LVD
Attaching the control unit to a wall. The mounting screw holes are hid­den behind the covers. If necessary, the control unit can be moved fur­ther away from the water guard using an extension cable.
The Veimart system is installed immediately after the water meter and the check valve. A possible pressure relief valve is usually installed af­ter the Veimart device. If there is not a lot of space for installation, it is recommended to a use a water meter coupling with a one-way valve, VM-3/4UKx1SK (accessory).