Veilux VP-58CND12X Instruction Manual

Page 1
MINI SPEED DOME CAMERA
Veilux Model # VP-58CND12X User Manual
12X Mini Speed Dome Camera
Instruction Manual
Website: www.Veilux.net Phone # 1-800-510-6528
Page 2
Veilux Model # VP-58CND12X User Manual
Warnings & Caution ---------------------------------------------------------------------------------------- 3
What’s in the Box? ----------------------------------------------------------------------------------------- 3
General Features --------------------------------------------------------------------------------------------- 4
Names of Each Part ---------------------------------------------------------------------------------------- 5
Installation ---------------------------------------------------------------------------------------------------- 6
A. Connections ---------------------------------------------------------------------------------- 6
B. Ceiling Mount Type ------------------------------------------------------------------------ 7
C. Embedded Mount Type ---------------------------------------------------------------------- 8
D. Pipe Mount Type ------------------------------------------------------------------------------ 10
E. Gooseneck Mount Type --------------------------------------------------------------------- 12
F. Wall Mount Type ------------------------------------------------------------------------------ 13
G. Corner Mount Type --------------------------------------------------------------------------- 15
H. Pole Mount Type ------------------------------------------------------------------------------ 17
Quick Operating Keys ------------------------------------------------------------------------------------- 18
Diagnostic ------------------------------------------------------------------------------------------------------ 20
OSD Menu Setting-------------------------------------------------------------------------------------------- 21
A. OSD Menu Table ------------------------------------------------------------------------------ 21
B. DOME SET ------------------------------------------------------------------------------------- 22
C. CAMERA SET --------------------------------------------------------------------------------- 27
D. PRESET ---------------------------------------------------------------------------------------- 29
E. AUTO SCAN SET----------------------------------------------------------------------------- 30
F. TOUR SET ------------------------------------------------------------------------------------- 31
G. PRIVACY SET --------------------------------------------------------------------------------- 32
H. PATTERN SET -------------------------------------------------------------------------------- 33
I. ALARM SET------------------------------------------------------------------------------------
34
J. SECTOR SET --------------------------------------------------------------------------------- 35
DIP Switch Setting ------------------------------------------------------------------------------------------ 36
A. Factory Default setting --------------------------------------------------------------------- 36
B. ID Setting (1-ON, 0-OFF)(1->10)---------------------------------------------------------- 36
C. Protocol Setting ------------------------------------------------------------------------------- 37
D. Baud Rate Setting ---------------------------------------------------------------------------- 37
E. 485 Terminations ------------------------------------------------------------------------------ 37
Trouble Shooting --------------------------------------------------------------------------------------------- 38
Specication -------------------------------------------------------------------------------------------------- 39
Dimension -------------------------------------------------------------------------------------------------- 40
Website: www.Veilux.net Phone # 1-800-510-6528
2
Page 3
The unit should be installed by the trained
personnel
Switch off immediately if the product emits
smoke or abnormal heat.
Never install the product in area exposed to
water, oil or gas.
Never install the product on a ceiling that
cannot hold its weight.
Never touch the power cord with wet hands.
Clean only with dry cloth.
Never install the product in extreme high or low
temperature.
Ensure that the product is not subjected to
strong impacts and vibration
Never expose the camera to direct sunlight
Never touch the front glass of the product.
Warning
Never manually move the pan/tilt as-
sembly. Serious and permanent dam-
age will occur
Veilux Model # VP-58CND12X User Manual
WARNINGS & CAUTION
If you fail to read this information and
handle the product incorrectly, death or
serious injury may occur.
This symbol is intended to alert the user to the presence of un-insulated “dangerous voltage” within the prod­uct’s enclosure that may be of suf-
cient magnitude to constitute a risk of
electric shock to persons.
This symbol is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
Website: www.Veilux.net Phone # 1-800-510-6528
3
What’s in the Box ?
1. Camera
2. Screws ( Ø4x16 screw 5EA )
3. Terminal block 5pin 2EA (DC Type)
4. Terminal block 5pin 1EA , 6pin 1EA
(AC 24V Type)
5. Manual
6. Screw Cap (1 EA)
Page 4
Veilux Model # VP-58CND12X User Manual
GENERAL FEATURES
12X Zoom Mini Speed Dome
12X Optical Zoom with 16X digital zoom
±0.05° dome system accuracy with full
micro step
With 0.05° positional accuracy, the camera provides excellent sensitive and delicate control. This is achieved by full micro step motors and twin gear system
360û Endless Rotation
12X mini speed dome is capable of endless rotation of 360 degrees
Compensation function: preset position
The function provides absolute preset position even in
difcult applications where vibration and strong winds may
otherwise affect dome performance.
Over 200°/Sec Preset Speed
The 360° full pan function moves through a maximum of 200°/sec., enabling you to quickly pinpoint the spot you want to watch. Tilt speed is also driven at 200°/sec on preset seek.
Polarity Protection of Power (DC12V)
This protection function prevents damage to the domes power board if the dc supply is connected with incorrect polarity.
Filter changeable True Day/Night
Top quality images are assured under day and night conditions due to the true day / night camera with IR cut
lter. Low light sensitivity is further increased by the
cameras digital slow shutter.
Indoor / Outdoor applications
The domes small size and construction to IP 66 ingress protection rating make it ideal for internal or external applications.
Quick Operation Keys
This camera provides quick function keys to allow control by most keyboards and DVRs that have Pelco protocol support.
Various Surveillance Functions
Auto Scan repeats pan and tilt between two preset
positions with different speed and dwell time.
8 Group Tour up to 8 Programmable Group tours are
available with each group is consisting of up to 60 preset steps with different speed and dwell times along with 16 character titling.
165 Preset positions up to 165 programmable
preset positions are available with 16 character title.
8 Patterns up to 8 programmable user-dened patters
are available with 16 character title. Each can be up to 50 seconds long, giving a total of 400 seconds.
8 Sectors up to 8 programmable user-dened sectors
are available with 16 character titling.
4 Privacy Masking Zones up to 4 programmable
user-dened privacy masking zones are available.
4 Alarm input up to 4 alarms can be wired to the dome
head and can activate presets, tours, or patterns.
150°/S – Manual speed
The dome provides up to 150°/sec of manual speed and is also adjustable from 100°/sec to 150°/sec in 10°/sec increments.
1/4” Sony Super HAD CCD
Equipped with Sony Super HAD CCD technology, the camera provides excellent sensitivity and low smear levels.
Intelligent Pan/Tilt Controlling Intelligent
Pan/Tilt function is continually increases or decreases
pan and tilt speeds in proportion to zoom.
Dome Housing
The elegantly designed aluminum body and Poly Carbonate dome cover provide a very solid product for a wide range of applications.
Password Protection
It is possible to password protect all dome settings to prevent unauthorized changes.
Website: www.Veilux.net Phone # 1-800-510-6528
4
Page 5
Veilux Model # VP-58CND12X User Manual
NAMES OF EACH PART
FIG. 1
1. Surface Mount Adaptor
2. Cap Screw (PT3/4, 1EA)
3. Dip Switch
4. Terminal Block
5. Main body
Website: www.Veilux.net Phone # 1-800-510-6528
5
Page 6
● Do not over tighten screws. This can cause damage.
Veilux Model # VP-58CND12X User Manual
INSTALLATION
A. CONNECTIONS
A-1
1. Loose the screws on the domes cover and remove it from the base. (Screws won’t be removed)
2. Loosen the screws which connect mount cover and Main base and separate dome cover from the main base. (These are captive screws that do not remove)
3. Connect power to Power and GND.
4. Connect video to video and GND.
5. Connect communication cable to RS-485 connectors.
6. Connect alarm common cables to GND. Connect the alarm input cables to their relevant terminal (1-4) Alarm polarity can be programmed as N/O or N/C
■ 12VDC type
24VAC
type
Website: www.Veilux.net Phone # 1-800-510-6528
6
FIG. 2
Page 7
Veilux Model # VP-58CND12X User Manual
INSTALLATION
B. CEILING MOUNT TYPE
1. Fix the surface mount adaptor with 4pcs of screws on the place where you want to install. (FIG. 3)
Caution ) Be sure to use seal tape for 3/4” cap screw to prevent a water leakage.
2. When you use pipe, please note the standard size of pipe. (FIG.4) Caution ) Be sure to use seal
tape for pipe screw to prevent a water leakage.
3. Re-assemble the dome.
FIG. 5
Website: www.Veilux.net Phone # 1-800-510-6528
7
FIG. 3
FIG. 4
Page 8
Contents
Embedded mount bracket 1ea Holder 3ea
Decoration cover 1ea ■ Safety wire 2ea
Screw – M3.0 x 6 5ea Screw - Ø4.0 x 16 1ea
Veilux Model # VP-58CND12X User Manual
INSTALLATION
C. EMBEDDED MOUNT TYPE
Website: www.Veilux.net Phone # 1-800-510-6528
8
SAFETY WIRE HOLE
LOCK LEVER
LOCK LEVER
SUSPENSION
SAFETY WIRE (150cm)
LOCK LEVER
LOCK LEVER
FIG. 6
FIG. 7
SAFETY WIRE (25cm)
M3 SCREW
M3.0 SCREW
CAMERA
HOLDER
DECORATION COVER
FIG. 8
Page 9
Veilux Model # VP-58CND12X User Manual
INSTALLATION
1. Make a hole, 190mm, on the ceiling. (FIG. 6)
2. Hook the safety wire over suspension and safety wire hold of embedded mount bracket.
Fold the lock levers and insert the bracket into the hole.
You can x the lock lever by driving screws. (FIG. 7)
3. Fix the decoration cover on the rear of camera by holder screws (M3.0) (FIG. 8)
4. Drive the screw (M4.0) to x safety wire of camera and hook the safety wire over safety
wire hold of embedded mount bracket. (FIG. 9)
5. Install the camera by inserting cover lock and twisting it clockwise. (FIG. 10)
6. Fix the decoration cover by screw (Ø4.0x16) (FIG. 10)
Website: www.Veilux.net Phone # 1-800-510-6528
9
FIG. 9
FIG. 10
Page 10
10
Contents
Pipe mount bracket 1ea Rubber 1ea
Screw – M4.0 x 8 4ea Set anchor bolt (W5/16) 4ea
Veilux Model # VP-58CND12X User Manual
INSTALLATION
D. PIPE MOUNT TYPE
Website: www.Veilux.net Phone # 1-800-510-6528
SCREW M4x8 (4ea)
BRACKET
(RUBBER BOTTOM VIEW)
RUBBER
BOTTOM COVER
FIG. 11
1. A s above FIG.11 , assemble rubber and bracket on the bottom of camera.
2. A fter finishing assembly, it will be shown as below. (FIG.12)
FIG. 12
Page 11
11
Veilux Model # VP-58CND12X User Manual
INSTALLATION
3. If you want to install the speed dome on the concrete wall, you need to make 12.5mm diameter
4 holes by drill like FIG. 13 (Depth 37mm)
4. Install SET ANCHOR BOLT on the holes.
5. As shown on FIG.15, after assembling mini PTZ and bottom cover assembly, drive the pipe mount
bracket and x. (FIG.15) Caution ) Be sure to use seal tape for pipe screw to prevent a water
leakage.
Website: www.Veilux.net Phone # 1-800-510-6528
<the cable
int
o the ceiling>
FIG. 13
<the cable out of the ceiling>
FIG. 14
PIPE MOUNT BRACKET
THREAD SEAL TAPE
BOTTOM COVER ASSEMBLY
MINI SPEED DOME CAMERA
FIG. 15
Page 12
12
Rub b er 1 e a
S cr ew M 4 x 8 4 e a
Veilux Model # VP-58CND12X User Manual
INSTALLATION
E. GOOSENECK MOUNT TYPE
Contents
■ Gooseneck mount bracket 1ea
■ Set anchor bolt (W5/16) 4ea
1. If you want to install the speed dome on the concrete wall, you need to make 12.5mm diameter
4 holes by drill like FIG.16 (Depth 37mm)
2. Install SET ANCHOR BOLT on the holes.
3. As shown on FIG.17, after assembling mini PTZ and bottom cover assembly, drive the gooseneck
mount bracket and x. (FIG.17) Caution ) Be sure to use seal tape for pipe screw to prevent a
water leakage.
Website: www.Veilux.net Phone # 1-800-510-6528
FIG. 16
<the cable into the ceiling> < the cable out of the ceiling>
GOOSENECK MOUNT BRACKET
THREAD SEAL TAPE.
BOTTOM COVER ASSEMBLY
MINI SPEED DOME CAMERA
FIG. 17
Page 13
13
Contents
Wall mount bracket 1ea ■ Set Anchor Bolt (W5/16) 4ea
Hexagon Socket head cap screw M4.0 x16 4ea
Hexagon wrench 3mm L Type 1ea
<the cable out of the ceiling>
Veilux Model # VP-58CND12X User Manual
INSTALLATION
F. WALL MOUNT TYPE
1. If you want to install the speed dome on the concrete wall, you need to make 12.5mm diameter
4 holes by drill like FIG. 1 (Depth 37mm) (FIG.18)
2. Install SET ANCHOR BOLT on the holes.
3. To install Wall Mount Bracket
Tip> Select a ceiling board strong enough to hold 4 times the total weight of the camera
(Weight combined camera: approx.5kg)
FIG. 18
FIG. 19
<the cable into the ceiling>
Website: www.Veilux.net Phone # 1-800-510-6528
Page 14
14
Veilux Model # VP-58CND12X User Manual
INSTALLATION
4. Assemble a wall mount bracket and camera by Hexagon socket head cap screws
(M4.0X16) (FIG. 20)
FIG. 20
Website: www.Veilux.net Phone # 1-800-510-6528
HEXAGON SOCKET HEAD CAP SCREW M4.0x16 4EA
Page 15
15
Contents
■ Corner mount adaptor 1ea ■ Set Anchor Bolt (W5/16) 4ea ■ M10 Bolt & Nut 4ea
Veilux Model # VP-58CND12X User Manual
INSTALLATION
G. CORNER MOUNT TYPE
1. First mark the positions of holes placing the corner mount bracket. (FIG. 21)
2. Make 12.5mm diameter 4 holes by drill. (Depth 37mm)
3. Install SET ANCHOR BOLT on the holes.
4. Fix the wanted bracket on the corner mount bracket with 4 ea of M10 BOLT before you install
the corner mount bracket. (FIG. 22)
5. Screw the set anchor bolt of the bracket by nut on the wall. (FIG. 23)
Website: www.Veilux.net Phone # 1-800-510-6528
FIG. 21
mark the positions of holes
M10.0 BOLT
GOOSENECK MOUNT BRACKET
GOOSENECK MOUNT BRACKET
CORNER MOUNT BRACKET
CORNER MOUNT BRACKET
FIG. 22
FIG. 23
Page 16
16
Veilux Model # VP-58CND12X User Manual
INSTALLATION
6. After driving a bottom cover assembly to gooseneck mount bracket, as shown on FIG 23,
assemble mini PTZ with bottom cover assembly. (FIG. 24) Caution ) Be sure to use seal
tape for pipe screw to prevent a water leakage.
Website: www.Veilux.net Phone # 1-800-510-6528
GOOSENECK MOUNT BRACKET
CORNER BRACKET
THREAD SEAL TAPE
BOTTOM COVER ASSEMBLY
MINI SPEED DOME CAMERA
FIG. 24
Page 17
17
Contents
■ Pole mount adaptor 1ea ■ Band Clamp 2ea ■ M10 Bolt & Nut 4ea
Veilux Model # VP-58CND12X User Manual
INSTALLATION
H. POLE MOUNT TYPE
1. Fix the wanted bracket on the pole mount bracket with 4 ea of M10 BOLT before you install the pole mount bracket. (FIG. 25)
2. Tie the bracket with SUS BAND tightly. (FIG. 26)
3. As shown FIG. 26 after installing a wall mount bracket, x a camera on the wall mount bracket.
(FIG. 27)
Website: www.Veilux.net Phone # 1-800-510-6528
FIG. 25
M10
BOLT
WALL MOUNT BRACKET
POLE MOUNT BRACKET
SUS
BAND
FIG. 26
HEXAGON SOCKET HEAD CAP SCREW M4.0x16 4ea
FIG. 27
Page 18
18
65 + preset
This feature is operated by preset number but not included in OSD main menu.
Veilux Model # VP-58CND12X User Manual
QUICK OPERATING KEYS
The dome supports Pelco-D/P, SAMSUNG and VICON protocols.
The dome may be used with any controller or DVR etc that supports the Pelco D and Pelco
P protocols.
The default setting of the dome is Pelco D / P with 2400 bps (baud rate).
[PELCO D/P, SAMSUNG PROTOCOLS]
The comprehensive feature set of the dome is available from Pelco compatible controllers via quick
operation keys as dened below.
1-64 + preset and 100~200 + preset are used for normal user presets.
Presets 65-99 + are reserved for special functions.
For example, to enter OSD MENU, press the button 95 +PRESET
<Quick Operation Key Table 1, Pelco D/P, SAMSUNG>
<Quick Operation Keys Table 2> Use these function keys if controller has these keys>
: “Preset Status” is displayed, to remove this screen, press Focus Near button.
92 + preset : This feature freezes the current live image during tour, auto scan or pattern opera-
tion. When you press 92 + preset button, the image freezes but the camera is still working as
per operation such as tour, pattern or auto scan. To return to normal images, press 92 + preset
button again.
If a controller asks for an unsupported feature “Not available” is displayed on the monitor.
Website: www.Veilux.net Phone # 1-800-510-6528
Number Note Function
1 ~ 64, 100~200 +Preset PRESET Execute Preset 1 ~ 64
65 + Preset PRESET STATUS Display Preset Status
66 +Preset AUTO SCAN Execute Auto Scan
67 +Preset AUTO FLIP Selectable On/Off/Auto in Auto Flip function
71~78 +Preset GROUP TOUR Execute Group Tour #1 ~ #8
81~88 +Preset PATTERN Execute Pattern #1 ~ #8
91 + Preset ZERO POSITION Search For Pan / Tilt Zero Position
92 + Preset FREEZE Select Freezing of current image
93 + Preset BLC MODE Selectable On/Off in BLC function
94 + Preset D/N MODE Selectable Day/Night Mode (Auto/Day/Night Mode)
95 + Preset OSD MAIN MENU To enter OSD Main Menu
96 + Preset FOCUS ADJUST Focus adjustment
97 +Preset ALARM Selectable Enable/Disable all Alarms
Menu Function
Tilt Up / Down Sub menu cursor moves up / down
Pan Left / Right Enter to the sub menu or status change or decrement
Focus Near Using for Enter key when user select YES or NO
Focus Far Using for function changing keys when set coordinate
Zoom Tele Status cursor to the right
Zoom Wide Status cursor to the left
Page 19
19
Veilux Model # VP-58CND12X User Manual
QUICK OPERATING KEYS
[VICON PROTOCOL]
If user wants to choose Vicon Protocol, the user may change the dip switch rst.
(Refer to Page #36 DIP SWITCH SETTING - PROTOCOL) Baud Rate: 4800 (Vicon
default)
The operation system is almost same as Pelco D/P protocols but some special features are
different way as noted below’
<Quick Operation Key Table 2: VICON>
<Quick Operation Keys Table 2> Use these function keys if controller has these keys>
Website: www.Veilux.net Phone # 1-800-510-6528
Number Note Function
1 ~ 79 +Preset PRESET Execute Preset 1 ~ 79
80~87 +Preset GROUP TOUR Execute Group Tour #1 ~ #8
88~89 +Preset PATTERN Execute Pattern #1 ~ #2
90 + Preset Focus Mode Set Focus Mode Toggle to Auto or Manual
90 + Preset Save Pan/Tilt Lockout PAN/TILT Lock or Unlock setting
91 + Preset Save ZERO POSITION Search For Pan / Tilt Zero Position
92 + Preset Save ALARM Selectable Enable/Disable all Alarms
93 + Preset Save BLC MODE Selectable On/Off in BLC function
94 + Preset Save OSD MAIN MENU To enter OSD Main Menu
95 + Preset Save D/N MODE Selectable Day/Night Mode (Auto/Day/Night Mode)
96 + Preset Save SECTOR SECTOR setting menu entrance
97 + Preset Save DOME Reset Initial DOME Reset - Rebooting
98 + Preset Save AUTO PAN AUTO PAN setting menu entrance
99 + Preset Save Pan/Tilt Speed Manual Pan/Tilt Max Speed setting
Menu Function
Tilt Up / Down Sub menu cursor moves up / down
Pan Left / Right Enter to the sub menu or status change or decrement
A/P Using for Enter key when user select YES or NO
A/I Using for function changing keys when set coordinate
Zoom Tele Status cursor to the right
Zoom Wide Status cursor to the left
Page 20
20
CAMERA ID : 001
BAUD RATE : 2400 BPS
WAITING………
PAN ORIGIN TEST OK
TILT ORIGIN TEST OK
TX CONNECTION TEST OK
CAMERA COMM TEST OK
Veilux Model # VP-58CND12X User Manual
DIAGNOSTIC
Whenever the dome is powered on, a standard diagnostic is operated.
The following messages are displayed on the monitor.
A. Pan Origin Test
Zero point of Pan is located during the Panning test.
B. Tilt Origin Test
Zero point of Tilt is located during the Tilt test.
C. TX connection Test
The TX connection test looks for commands from a controller to the dome. If no commands are
detected the test will exit after 60 seconds.
During the 60 seconds, the camera must receive a signal from the controller or DVR, so please
operate the controller during this phase. As soon as the dome detects a command “OK” will be
displayed and the test will move on to the next step.
If the Tx connection test fails check the RS 485 wiring.
D. Camera Comm. Test
Camera communication is also checked.
OK should be displayed in these four tests before installation.
If all the above Tests are OK, “NOW EEPROM CHECKING” and “ALL DATA INITIALIZING” is dis-
played and the camera is ready to operate.
Website: www.Veilux.net Phone # 1-800-510-6528
Page 21
Veilux Model # VP-58CND12X User Manual
OSD ME NU S ETTING
A. OSD MENU TABLE
Website: www.Veilux.net Phone # 1-800-510-6528
21
MAIN MENU DOME SETUP
CAMERA SET
AUTO SCAN
TOUR
PRAVACY
PATTERN
ALARM
SECTOR
EXIT
DOME SET
CAMERA ID : CAM1
RECOVER : OFF
MANUAL SPEED : 100 °/S
AUTO FLIP
: OFF
ZOOM SPEED : FAST
ALARM : DISABLE
LANGUAGE : ENGLISH
[NEXT PAGE]
SAVE AND EXIT
CAMERA SET
FLICKER : OFF/ON
MIRROR : OFF /ON
D ZOOM : OFF/ON
WB MODE
: AWB MODE
PIC FLIP : OFF/ON
BLC : OFF/ ON
D/N MODE : AUTO
DSS MODE : OFF/ON
EXIT
PRESET SET
PRESET NO: 001
PRESET ID: PRESET01
PAN:XXX.X.XX.X TILT:XXX.X.XX.X
SAVE
EXIT
AUTO SCAN SET
START ANGLE : XXX.X.XX.X
END ANGLE : XXX.X.XX.X
DIRECTION
: CW
ENDLESS : OFF/ON
SPEED : QUICK
DWELL TIME : 03
SAVE AND EXIT
EXIT
TOUR SET
TOUR NO. : 01
TOUR TITLE : TOUR01
TOUR STEP : 01
PRESET NO : 01
DWELL TIME : 3
SPEED : 20 0°/S
SAVE AND EXIT
EXIT
PRIVACY SET
PRIVACY NO. : 01
DISPLAY : ON/OFF
ACTION : MOVE/ADJUST
SAVE
EXIT
PATTERN SET
PATT NO. : 01
PATT TITLE PATTERN01
DATA FILL : 100 %
SAVE
EXIT
ALARM SET
ALARM NO. : 01
ALARM INPUT
: OFF
ALARM ACT : 01
SAVE
EXIT
SECTOR SET
SECTOR NO : 01
SECTOR ID : SECTOR01
SECTOR START: XXX.X.XX.X
SECTOR END : XXX.X.XX.X
SAVE
EXIT
DOME
SET
SYSTEM LOCK : OFF
[PASS WORD]
[OSD DISPLAY] [SYSTEM STATUS]
[INITIALIZATION]
[PREVIOUS PAGE]
OSD DISPLAY
CAMERA ID : OFF/ON
PRESET ID: OFF/ON
SECTOR ID: OFF ON
COORDINATE:ON/OFF
[PREVIOUS PAGE]
[SYSTEM STATUS]
PROTOCOL : PELCO D,P
BAUD RATE: 2400BPS
FIRMWARE VER.:2.00
UPGRADED DATE: 06.28,06 CAMERA MODULE: SDM100
[PREVIOUS PAGE]
[INITIALIZATION]
[TOUR CLEAR]
[PRESET CLEAR]
[SECTOR CLEAR]
[PRIVACY CLEAR]
[PATTERN CLEAR]
[LOAD OPTIMIZED DEFAULT
[REVIOUS PAGE]
Page 22
22
ZOOM
DOME SET
CAMERA ID : CAM1 RE­COVER : OFF
MANUAL SPEED : 100°/S AUTO FLIP : OFF
ZOOM SPEED : FAST
ALARM : DISABLE
LANGUAGE : ENGLISH
[NEXT PAGE]
SAVE AND EXIT
EXIT
MAIN MENU
DOME SETUP CAMERA SET
PRESET
AUTO SCAN
TOUR
PRIVICY
PATTERN
ALARM
SECTOR
EXIT
* Use “ up down” to move the position and “ left right” to make selection
Veilux Model # VP-58CND12X User Manual
OSD MENU SETTING
To enter OSD Menu, press the button 95 + PRESET.
B. Dome Setup
In order to enter Dome setup, select right direction when the cursor is on dome setup.
DEFAULT SETTING
B-1. DOME SET - CAMERA ID
To set camera name, and select a title of up to 16 characters using left or right direction keys or
joystick.
Press TELE button to move to the next character from left to right direction and
ZOOM WIDE button to move to the next character from right to left direction (Space
displays when appears)
Website: www.Veilux.net Phone # 1-800-510-6528
Page 23
23
default setting is DISABLED.
This function can be recalled by pushing 97 + preset button.
DOME SET
SYSTEM LOCK: : OFF [PASS WORD] [OSD DISPLAY] [SYSTEM STATUS] [INITIAL­IZATION] [PREVIOUS PAGE]
The default setting is 100û/sec
The
default setting is FAST.
The default setting is ENGLISH.
The default setting is OFF.
Veilux Model # VP-58CND12X User Manual
OSD MENU SETTING
B-2. DOME SET - RECOVER
This feature allows the dome to revert to a specic programmed action when the dome has not
received a command for the recovery timer period.
Actions can be Auto scan, group tour and pattern. The recovery time can be programmed from
15 second to 90 seconds. The default setting is OFF.
B-3. DOME SET - MANUAL SPEED
The manual speed of Pan/Tilt is selectable from 100û/sec up to 150û/sec.
B-4. DOME SET - AUTO FLIP
Auto Flip enables the dome to automatically do a 180û turn when the tilt bottom point is reached.
default setting is OFF. This function can be recalled by pushing 67+ preset button.
B-5. DOME SET - ZOOM SPEED
Zoom speeds are selectable as FAST or SLOW mode. The
B-6. DOME SET - ALARM
You must enable the alarms for them to operate. The
B-7. DOME SET - LANGUAGE
Multiple languages are selectable (English, German, Dutch, Danish, French)
B-8. DOME SET - [NEXT PAGE]
DEFAULT SETTING
B-8-1. DOME SET - [NEXT PAGE] - SYSTEM LOCK
All stored dome settings can be password protected to prevent unauthorized changes.
In order to enter [PASS WORD] page, the system lock status must rstly be set as ON.
Website: www.Veilux.net Phone # 1-800-510-6528
Page 24
24
ENTER PASSWORD
BY ENTERING PRESET CODE
PASSWORD ***
CONFIRM ***
ENTER PASSWORD
BY ENTERING PRESET CODE
PASSWORD ***
CONFIRM ***NOT CORRECT
ENTER PASSWORD
BY ENTERING PRESET CODE
PASSWORD ***
CONFIRM ***CONFIRMED
OSD DISPLAY
CAMERA ID : OFF
PRESET ID : OFF
SECTOR ID : OFF
COORDINATE : ON [PRE­VIOUS PAGE]
Veilux Model # VP-58CND12X User Manual
OSD MENU SETTING
B-8-2. DOME SET - [NEXT PAGE] - [PASSWORD]
To enter this page to set a password, move joystick or pan key in the right direction.
The password must be set by preset number from 001 to 255 (Default 99)
Enter any number from 001~255 on the password blank area and again for conrmation on
blank area. Then “CONFIRMED” is displayed on the monitor and the menu will go back to the previous page automatically.
<CONFIRMED> <CANCELLED>
If you press an incorrect number between PASSWORD and CONFIRM, “NOT CORRECT” is displayed on the monitor.
B-8-3. DOME SET - [NEXT PAGE] - [OSD DISPLAY]
The camera ID setting denes whether the camera OSD display is displayed or switched off.
DEFAULT SETTING
Website: www.Veilux.net Phone # 1-800-510-6528
* When a password has been set, the operator must enter the correct password in order to
enter OSD MAIN MENU, or to change any of the domes conguration
data
* If you set a password you must ensure that it does not get lost. If this happens the dome
must be returned for workshop repair
Page 25
25
SYSTEM STATUS
PROTOCOL : PELCO D, P
BAUD RATE : 2400 BPS
FIRMWARE VER. : X.XX
UPGRADED DATE : YY.MM.DD
CAMERA MODULE : XXXXXXXX [PREVIOUS PAGE]
INITIALIZATION
[TOUR CLEAR] [PRESET CLEAR] [SECTOR CLEAR] [PRIVACY CLEAR] [PATTERN CLEAR] [LOAD OPTIMIZED DE­FAULT] [PREVIOUS PAGE]
TOUR CLEAR
ARE YOU SURE? YES NO
TOUR CLEAR
Veilux Model # VP-58CND12X User Manual
OSD MENU SETTING
B-8-4. DOME SET - [NEXT PAGE] - [SYSTEM STATUS]
This page shows the information of this camera.
DEFAULT SETTING
- Protocol and baud rate are shown according to the dip switch setting (Refer to page 36,
37)
- Firmware version and upgraded date will be changed if the dome has been upgraded.
- The camera module type is stated as follows.
● SDM100 : SAMSUNG 10X ZOOM CAMERA MODULE.
B-8-5. DOME SET - [NEXT PAGE] - [INITIALIZATION]
To clear the current settings select the item that you wish to reset back to factory defaults.
- To clear the memorized data, move the joystick or pan right key until the cursor is on the required item.
Website: www.Veilux.net Phone # 1-800-510-6528
Page 26
26
LOAD OPTIMIZED DEFAULT
ARE YOU SURE? YES NO
ALL DATA INITIALIZING
Veilux Model # VP-58CND12X User Manual
OSD MENU SETTING
Press FOCUS NEAR button when the cursor is at YES in order to clear memorized data.
Then each item such as tour, preset, and sector will icker for about 2~3 seconds. After this
process, the menu is returned to the previous page.
- To clear all data and return to factory defaults, move the joystick right or press the pan
right key to when the cursor is at [LOAD OPTIMIZED DEFAULT] to enter the next page.
- Move joystick or the pan right keys so that the cursor is over YES, then press the FOCUS NEAR button.
“ALL DATA INITIALIZING” is then displayed for about 5~7 seconds and then the menu is re­turned to the previous page automatically.
B-9. DOME SET - [NEXT PAGE] - SAVE AND EXIT
To save the memorized data and escape this page, move the joystick right or press the pan right key when cursor is at SAVE AND EXIT.
B-10. DOME SET - [NEXT PAGE] - EXIT
In order to escape this page, move the joystick right or press the pan right key when the cursor is at EXIT
Website: www.Veilux.net Phone # 1-800-510-6528
* Use the above method for [PRESET CLEAR], [SECTOR CLEAR], [PRIVACY CLEAR],
[PATTERN CLEAR], [TOUR CLEAR].
Page 27
27
CAMERA SET
FLICKER : OFF
MIRROR : OFF
APERTURE : 10
D ZOOM : OFF
WB MODE : AWB MODE
PIC FLIP : OFF
BLC : OFF
D/N MODE : AUTO
DSS MODE : OFF
EXIT
The default setting is OFF.
The default setting is OFF.
default seeting is 10.
Veilux Model # VP-58CND12X User Manual
OSD MENU SETTING
C. CAMERA SET
DEFAULT SETTING
C-1. CAMERA SET - FLICKERLESS
The icker less feature has options of 50Hz and 60Hz.
The default setting is OFF (NTSC: 60Hz / PAL: 50Hz). The icker less mode only needs to be
set when there is a mismatch between the power frequency and camera sync rate.
C-2. CAMERA SET - MIRROR
This feature literally swaps the image left and right as if looking into a mirror.
C-3. CAMERA SET - APERTURE
Aperture correction enhances the picture details and sharpness by increasing the gain of the caemra. Increade the value to sharpen the image, decrease to soften it The (the aperture level is from 01 ~ 15)
C-4. CAMERA SET - D ZOOM
If neabled digital zoom is applied when the zoom lens has reached its maximum optical zoom in capability The default setting is OFF.
C-5. CAMERA SET - WB MODE
White balance functions has 4 modes and may need to be changed depending on the situation.
AWB Mode – 3,200ûK to 6, 000ûK (Default)
Indoor – up to 3,200ûK
Outdoor – up to 5,800ûK
ATW Mode - 2,000ûK to 10, 000ûK
Website: www.Veilux.net Phone # 1-800-510-6528
Page 28
28
The default setting is OFF.
The default setting is AUTO MODE.
The default setting is OFF.
Veilux Model # VP-58CND12X User Manual
OSD MENU SETTING
C-6. CAMERA SET - PIC FLIP
The picture ip feature swps the top and bottom of the image, literally inverting it.
C-7. CAMERA SET - BLC (Back Light Compensation)
The default setting is OFF and BLC modes can be OFF/ON.
● OFF – Backlight compensation is not activated.
● ON – Back light compensation is activated.
This function can be recalled by pushing 93 + preset button.
C-8. CAMERA SET - D/N MODE
The dome camera can operate in day /night mode and will switch depending on lighting
conditions. Alternatively it can be forced into color only mode.
This function can be recalled by pushing 94 + preset button.
C-9. CAMERA SET - DSS MODE (DIGITAL SLOW SHUTTER)
If digital slow shutter is enabled the exposure time of the camera is increased, this allowing more light to be collected and improving low light response. This setting should not be enabled
if the dome is touring at night or fast moving objects are likely to be in the scene as smearing is
also increased.
C-10. CAMERA SET - EXIT
To escape this page, move the joystick right or press the pan right key.
Website: www.Veilux.net Phone # 1-800-510-6528
Page 29
29
The
PRESET SET
PRESET NO :001
PRESET ID :PRESET001-------
PAN :XXX.XX TILT : XXX.XX
SAVE
EXIT
Veilux Model # VP-58CND12X User Manual
OSD MENU SETTING
D. PRESET SET
To enter PRESET SET, move joystick to the right direction.
DEFAULT SETTING
D-1. PRESET - PRESET NO.
Up to 165 preset positions are available. Use the joystick or pan left/right keys to select the number.
D-2. PRESET - PRESET ID
To create preset titles use the joystick or pan left/right keys to navigate the menu.
ZOOM TELE button moves to the next character from left to right and ZOOM WIDE
button moves to the next character from right to left (Space displays when £ appears)
D-3. PRESET - PAN: XXX.X TILT: XX.X
Press FOCUS FAR button in order to set preset position then, use the joystick or pan left/right keys to the position where memorized preset number .is needed. Then press FOCUS FAR but­ton again after setting a preset location.
D-4. PRESET - SAVE
Move the joystick right or press the pan right key when the cursor is at SAVE and then the cursor will be located on Preset ID for the continuous preset No. setting.
D-5. PRESET - EXIT
To escape this page, move the joystick right or press the pan right button.
Website: www.Veilux.net Phone # 1-800-510-6528
Page 30
30
FOCUS FAR button again is to escape.
FOCUS FAR button again is to escape.
AUTO SCAN SET
START ANGLE : XXX.X.XX.X END ANGLE : XXX.X.XX.X
DIRECTION : CW
ENDLESS : OFF SPEED : 10°/S
DWELL TIME : 03
SAVE AND EXIT
EXIT
The default setting is OFF.
default setting is 10û/S.
The default setting is 03 seconds.
Veilux Model # VP-58CND12X User Manual
OSD MENU SETTING
E. AUTO SCAN SET
DEFAULT SETTING
E-1. AUTO SCAN - START ANGLE
To set the start position, press FOCUS FAR button then move the dome to the required start position. Press
E-2. AUTO SCAN - END ANGLE
To set the end position, press FOCUS FAR button then move the dome to the required end position. Press
E-3. AUTO SCAN - DIRECTION
Auto Scan directions are available as CW or CCW.
● CW: Clock wise direction (Default)
● CCW: Count Clock Wise Direction.
E-4. AUTO SCAN - ENDLESS
Auto Scan can be set to endless rotation by enabling the endless option.
E-5. AUTO SCAN - SPEED
Auto scan speed can be programmed from 05û/S up to 35û/S.
The
E-6. AUTO SCAN - DWELL TIME
The dwell time at the start and end points can be programmed from 1 second to 30 seconds.
E-7. AUTO SCAN - SAVE AND EXIT
To save the memorized data and escape this page, move the joystick right or press the pan right key when the cursor is at SAVE AND EXIT.
E-8. AUTO SCAN - EXIT
To escape this page, move the joystick right or press the pan right key.
Website: www.Veilux.net Phone # 1-800-510-6528
*
66 + pre­set
button is working as AUTO SCAN after set­ting.
Page 31
31
The default setting is 200û/S.
TOUR SET
TOUR NO : 01 TOUR TITLE : TOUR01
TOUR STEP : 01
PRESET NO. : 01
DWELL TIME : 03
SPEED : 200 /S
SAVE
EXIT
The default setting is BLK
setting is 03 seconds.
Veilux Model # VP-58CND12X User Manual
OSD MENU SETTING
F. TOUR SET
8 Programmable tours can be set and each tour can have up to 64 preset steps. After setting up the tours the 71~78 + preset buttons launch group tours # 1~8
DEFAULT SETTING
F-1. TOUR SET - TOUR NO.
Up to 8 group tours can be programmed.
F-2. TOUR SET - TOUR TITLE
To set a tour title, use the joystick left/right or pan left/right keys.
Each title can have up to 16 characters.
Press
ZOOM TELE button to move the next character from left to the right and ZOOM WIDE
button to move the next character from right to left (Space displays when appears) The tour title is not displayed on the monitor and is only for the reference of user.
F-3. TOUR SET - TOUR STEP
Each tour group consists of up to 60 preset steps with different dwell time and speed.
It is possible to match any preset # for any tour step.
F-4. TOUR SET - PRESET NO.
For each tour step it is possible to select any preset number up to 64.
F-5. TOUR SET - DWELL TIME
Dwell time can be programmed from 1-99 seconds. The default
F-6. TOUR SET - SPEED
Each tour step can be set with a different speed up to 200û/S and it is selectable from 10û/S.
F-7. TOUR SET - SAVE
To save the memorized data and escape this page, move the joystick right or press the pan right key when cursor is at SAVE
F-8. TOUR SET - EXIT
To escape this page, move the joystick right or press the pan right key.
Website: www.Veilux.net Phone # 1-800-510-6528
Page 32
32
FOCUS FAR button to escape the ADJUST mode.
PRIVACY SET
PRIVACY NO : 01 DISPLAY : OFF
ACTION : MOVE
SAVE
EXIT
default setting is OFF.
Veilux Model # VP-58CND12X User Manual
OSD MENU SETTING
G. PRIVACY SET
4 Privacy masking zones can be set.
DEFAULT SETTING
G-1. PRIVACY SET - PRIVACY NO.
Up to 4 privacy masking zones can be set.
G-2. PRIVACY SET - DISPLAY.
Move the joystick right or left or press pan right/left to set ON in order to show the selectable block in the center of the monitor. This block appears as a translucent square with blue color when set ON. The
G-3. PRIVACY SET - ACTION (MOVE / ADJUST)
To set the blocking area, press FOCUS FAR button when MOVE MODE is displayed.
Then use the joystick or pan keys to the user dened area in order to set the blocking area.
Then press FOCUS FAR button again to escape from MOVE MODE. To adjust the size of the blocking area, move the joystick or use the pan keys when the cursor is on ACTION. After it has changed to ADJUST MODE, press FOCUS FAR button in order to adjust the size of the blocking area. The size of the blocking area can be adjusted by using joystick up/down or left right – or the pan and tilt keys. After adjusting the size of the blocking area, press
● ADJUST : You can change the masking size by using the joystick or pan keys
● MOVE : You can move the masking area by using the joystick or pan keys (Default)
G-4. PRIVACY SET - SAVE
After setting the privacy masking zone, to save the data, move the joystick right or pan right key when the cursor is on SAVE. After saving the data, the cursor moves to PRIVACY NO.2 auto­matically to prepare for the next privacy masking zone.
G-5. PRIVACY SET - EXIT
To escape this page, move the joystick right.
Website: www.Veilux.net Phone # 1-800-510-6528
Page 33
33
PATTERN SET
PATT NO : 01
PATT TITLE: PATTERN01□□□□□□□
DATA FILL : 0%
SAVE
EXIT
Veilux Model # VP-58CND12X User Manual
OSD MENU SETTING
H. PATTERN SET
8 programmable patterns are available, each with a programmable title.
After setting up each pattern # 1~8, 81~88+ preset buttons will recall Patterns # 1~8.
DEFAULT SETTING
H-1. PATTERN SET - PATT NO.
Up to 8 programmable user-dened patterns are available.
H-2. PATTERN SET - PATT TITLE
To set PATTERN TITLE move Joystick left/right or use the pan keys.
Press
ZOOM TELE button moves to the next character from the left / right and ZOOM WIDE button moves to the next character from the right / left (Space displays when appears) The pattern title is not displayed on the monitor, but only for the reference of the user.
H-3. PATTERN SET - DATA FILL
To memorize a pattern, press FOCUS FAR button in order to start the process.
The progress is shown as % lled. Press FOCUS FAR button again in order to escape.
H-4. PATTERN SET - SAVE
To save the memorized pattern data, move the joystick right or press the pan right key when the cursor is on SAVE. Then the cursor moves to the PATT NO.02 in order to prepare for the next pattern.
H-5. PATTERN SET - EXIT
To escape this page, move the joystick right or press the pan right key.
Website: www.Veilux.net Phone # 1-800-510-6528
Page 34
34
ALARM SET
ALARM NO : 01 ALARM INPUT : OFF ALARM ACT : 001
SAVE
EXIT
The default setting is OFF.
Veilux Model # VP-58CND12X User Manual
OSD MENU SETTING
I. ALARM SET
4 Alarm inputs are available and each input can activate presets, group tours or patterns.
DEFAULT SETTING
I-1. ALARM SET - ALARM NO.
Up to 4 alarms are selectable by using joystick right or pressing the pan right key when the cursor is on ALARM NO.
I-2. ALARM SET - ALARM INPUT
Alarm inputs can be programmed as NC (Normally Close) or NO (Normally Open)
I-3. ALARM SET - ALARM ACT
Active alarms can trigger modes such as presets, Group tours 1-8, and Patterns 1-8.
Use the joystick or pan keys to select any preset number, group tour no. or pattern no.
I-4. ALARM SET - SAVE
After setting up the alarm features, to save the data move the joystick right or press the pan right key when the cursor is on SAVE. After saving the data, the cursor moves to Alarm NO.2 automatically to prepare for the next alarm.
I-5. ALARM SET - EXIT
To escape this page, move the joystick right or press the pan right key.
Website: www.Veilux.net Phone # 1-800-510-6528
* Before activating Alarms, you must set ALARM ENABLE at DOME SET – ALARM – EN­ABLE
(Refer to page
23)
Page 35
35
FOCUS FAR button again to escape.
SECTOR SET
SECTOR NO : 01
SECTOR ID: SECTOR01□□□□□□□□
SECTOR START: XXX.X.XX.X
SECTOR END : XXX.X.XX.X
SAVE
EXIT
Start Position
End Position
Veilux Model # VP-58CND12X User Manual
OSD MENU SETTING
J. SECTOR SET
Up to 8 programmable sectors are available, each with a 16 character title.
This feature allows the various areas of the domes 360û rotation to be given logical titles.
When the dome is moved the relevant title for each area is displayed as the dome passes through the area.
DEFAULT SETTING
J-1. SECTOR SET - SECTOR NO.
Up to 8 programmable sectors are available.
J-2. SECTOR SET - SECTOR ID
To set a SECTOR ID, use the joystick or pan left/right keys.
Press ZOOM TELE button to move to the next character from left to right and ZOOM WIDE
button to move to the next character from right to left (Space displays when appears)
J-3. SECTOR SET - SECTOR START
To set a SECTOR START position, press FOCUS FAR button then move the joystick or pan keys to set the position. Press
J-4. SECTOR SET - SECTOR END
To set a SECTOR END position, press FOCUS FAR button then move the joystick or pan keys to set the position. To press FOCUS FAR button again to escape.
J-5. SECTOR SET - SAVE
After setting the SECTOR positions, to save the data move the joystick right or press the pan right key when the cursor is on SAVE. After saving the data, the cursor moves to SECTOR NO.2 automatically to prepare for the next SECTOR.
J-6. SECTOR SET - EXIT
To escape this page, move the joystick right or press the pan right key.
K. EXIT
To escape OSD Main Menu, move joystick to the right or left direction then this camera is
Ready to operate.
Website: www.Veilux.net Phone # 1-800-510-6528
Page 36
36
* Factory default: Camera ID = 1, PELCO-D Baud Rate: 2400bps
Protocol
ID Set
Veilux Model # VP-58CND12X User Manual
DIP SWITCH SETTING
A. FACTORY DEFAULT SETTING
The dome cameras RS 485 address is set using switches 1-6 of DIP SW1, refer to the table below...
Open the camera case to set ID using DIP SW1.
Termination
Baud rate
B. ID SETTING (1-ON, 0-OFF) (1è10)
Website: www.Veilux.net Phone # 1-800-510-6528
DIP SW ID VALUE DIP SW ID VALUE DIP SW ID VALUE
100000XXXX 1 111010XXXX 23 101101XXXX 45
010000XXXX 2 000110XXXX 24 011101XXXX 46
110000XXXX 3 100110XXXX 25 111101XXXX 47
001000XXXX 4 010110XXXX 26 100011XXXX 48
101000XXXX 5 110110XXXX 27 100011XXXX 49
011000XXXX 6 001110XXXX 28 010011XXXX 50
111000XXXX 7 101110XXXX 29 110011XXXX 51
000100XXXX 8 011110XXXX 30 001011XXXX 52
100100XXXX 9 111110XXXX 31 101011XXXX 53
010100XXXX 10 000001XXXX 32 011011XXXX 54
110100XXXX 11 100001XXXX 33 111011XXXX 55
001100XXXX 12 010001XXXX 34 000111XXXX 56
101100XXXX 13 110001XXXX 35 100111XXXX 57
011100XXXX 14 001001XXXX 36 010111XXXX 58
111100XXXX 15 101001XXXX 37 110111XXXX 59
000010XXXX 16 011001XXXX 38 001111XXXX 60
100010XXXX 17 111001XXXX 39 101111XXXX 61
010010XXXX 18 000101XXXX 40 011111XXXX 62
110010XXXX 19 100101XXXX 41 111111X XXX 63
001010XXXX 20 010101XXXX 42
101010XXXX 21 110101XXXX 43
011010XXXX 22 001101XXXX 44
Page 37
37
Factory Default: Pelco-D or Pelco-P (Auto detection)
Veilux Model # VP-58CND12X User Manual
DIP SWITCH SETTING
C. PROTOCOL SETTING
7th~8
th
dip switches are used for Protocol Setting.
D. BAUD RATE SETTING
The 9
th
Dip Switch is used for BAUD RATE setting.
DIP SW can be changeable to 2400bps, 9600bps.
Factory Default: 2400bps. (If user selects Vicon protocol, then Baud rate is automatically set
as 4800bps.
E. 485 TERMINATIONS
10
th
Dip Switch is used for 100Ω termination.
Set on 10
th
Dip Switch only for the last looped camera from the controller.
Even in case of only one camera, set on 10
th
Dip Switch of the camera.
Website: www.Veilux.net Phone # 1-800-510-6528
DIP SW1- 7 DIP SW1- 8
OFF OFF Pelco-D or Pelco-P
ON OFF VICON
OFF ON SAMSUNG
ON ON
DIP SW1 9
th
BAUD RATE
OFF
2400bps(Default) 4800bps(VICON)
ON 9600bps
TERMINATION SW-ON
CAM 1 CAM 2 CAM n-1 CAM n
Page 38
38
Veilux Model # VP-58CND12X User Manual
TROUBLE SHOTING
If you have trouble setting up or operating the camera, refer to the following.
Website: www.Veilux.net Phone # 1-800-510-6528
PROBLEM SOLUTION
No operation
Check if the power supply is DC12V.
Check if RS-485 communication cable is connected correctly.
Check camera ID setting.
Check the RS 485 termination.
No picture
Check if all the cables are connected correctly.
Check if the monitor is adjusted correctly.
Check for video locally at the dome.
Dark screen Check video termination and monitor settings
Abnormal camera
operation
Check if PSU voltage level at the dome
Check the RS 485 termination.
Page 39
39
Veilux Model # VP-58CND12X User Manual
SPECIFICATIONS
DIMENSIONS
Website: www.Veilux.net Phone # 1-800-510-6528
MODEL 12X Mini Speed Dome Camera
PAN /TILT
Pan Rotation Angle 360 Endless
Pan Speed
Manual Preset Max 150 /sec Max 200 /sec
Tilt Rotation Angle 0 ~ 90
Tilt Speed
Manual Preset Max 150 /sec Max 150 /sec
FUNCTIONS
Presets
165 positions with a 16-character label available for each
Privacy Masking Zones 4 Programmable privacy masking zones
Pattern 8 Programmable pattern tour
Sector 8 Programmable sectors
Group Scanning
Max.8 Programmable group tours (each one consisting of up to 60 preset steps with different steps)
Auto scan Programmable Auto scan
Password Protection Yes
Alarm Input 4 alarms OFF/NC/NO (with various programmable states)
Alarm Actions Activate preset, tour and patterns
Auto Flip ON / OFF
OSD Menu Multiple Languages on screen
Communication RS-485
Protocol Pelco D/P, VICON, SAMSUNG
POWER Power Consumption
12V DC 750mA, 10W MAX (1.3A, 16W MAX with Heater)
Power Supply 12V DC 750mA (1.3A with Heater)
OTHERS
Construction Anti-vandal bubble (Poly carbonate), Body (Aluminum)
Motor Type Stepper Motor
Operating Temperature -10 C ~ 50 C (-40 C ~60 C with heater)
Certications IP66,CE,FCC
Image Sensor 1/4” Sony Super HAD CCD
CAMERA MODULE
Total Image Pixels
NTSC
PAL
811(H) * 508(V) 410K 795(H) * 596(V) 470K
Number Of Effective Pixels
NTSC PAL
768(H) * 494(V) 380K 752(H) * 582(V) 440K
Horizontal resolution 560 TV Lines/ B/W 660 TV Lines
Lens
Optical 12x Optical Zoom f=3.94 ~ 46.05mm (F1.67~1.88)
Digital 12x (192x with optical)
Day & Night (ICR) Auto/ Day/ Night
Digital Slow Shutter ON / OFF
Min. illumination
Normal mode Night mode
0.2Lux / F1.6 (Color: 50IRE) 0.04Lux / F1.6 (B/W : IRC ON)
Luminance S/N Ratio More than 502B
Video Output Composite video output 75Ω Terminated
BLC ON / OFF
Flicker less
NTSC PAL ON / OFF (1/100) ON / OFF (1/120)
WHITE BALANCE ATW/AWC/INDOOR/OUTDOOR
Page 40
Website: www.Veilux.net Phone # 1-800-510-6528
40
Veilux Model # VP-58CND12X User Manual
UNITS : mm
Loading...