Veichi SI30 series, SI30-D3 series, SI30-D5 series, SI30-D1 series User Manual

SI30 Solar Pump Inverter Manual
1
Chapter 1: Safety Requirement and Cautions
To ensure safety of your health, equipment and property, please read this chapter carefully before using
and overhauling the inverter.
1.1 Safety Definition
Danger: it will cause danger of serious injuries and even death while operating against the rules.
Caution: it will cause danger of light injuries or equipment destruction while operating against the
rules.
Note: some information is useful while operating and using solar pump inverter.
1.2 Safety Requirements and Cautions
●Before Installation
Danger
1. Only qualified personnel can operate the equipment. Before operating, be sure to carefully
read the manual. The safe operation depends on the proper processes of choosing models, carrying, installation, operation and maintenance.
2. Don’t use the damaged or incomplete solar pump inverters; Otherwise, there is risk of injury.
●Installation
Danger
1. Please install the solar pump inverter on metal or other nonflammable material, and keep it
away from the combustible material. Otherwise there is danger of fire.
2. No unauthorized modification to the solar pump inverter; Otherwise there is danger of damage.
3. Normal solar pump inverter without explosion-proof cannot be installed where with explosive gas or dust; Otherwise there is danger of explosion.
●Wiring
Danger
1. Wire is connected only when the main circuit is cut off, otherwise there is a danger of shock.
2. Wire is connected by professional person only. Otherwise there is a danger of shock.
3. Earth must be reliable. Otherwise there is a danger of shock.
4. DC power supply should not be connected to output terminals U, V, W, otherwise there is a
danger of damage to solar pump inverter.
5. No drop of bolt, spacer, metal stick, conducting wire or other things into the inner of solar
pump inverter; Otherwise there is a danger of fire or damage to solar pump inverter.
Attention
1. If the damage to solar pump inverter or other equipment is caused by improper wiring and
utilization or unauthorized alteration, the user should shoulder all responsibilities.
SI30 Solar Pump Inverter Manual
2
2. Please make sure all wirings meet EMC requirements and satisfy safety standards in the
local area; Please refer to recommendations in this manual or national standards of wire diameter to avoid accidents.
3. Static electricity on human body would seriously damage internal MOS transistor, etc. Don’t
touch the printed circuit boards, IGBT or other internal devices without anti-static measurements; otherwise it will cause the malfunction to solar pump inverter.
4. Please don't connect phase shift capacitance or LC/RC noise filter to the output circuit of
solar pump inverter; Otherwise it will damage the inverter.
5. Please don't connect the magnetic switch or magnetic contactor to the output circuit of solar
pump inverter; When solar pump inverter is in the operation with load, magnetic switch or magnetic contactor can make inverter over-current protection act. It will damage solar pump inverter seriously.
6. Please don't dismantle the panel cover, and it only needs to dismantle the terminal cover
when wiring.
7. It is forbidden to do any pressure test on solar pump inverter, otherwise it will damage the
solar pump inverter.
●Before Electrification
Danger
1. Please make sure that voltage grade of power supply is consistent with solar pump inverter's
rated voltage and then check whether the wiring is correct, and whether there is short circuit in peripheral equipment's circuit. Otherwise it will damage solar pump inverter and other equipment.
2. Before the solar pump inverter is connected to the input power supply, make sure that the
cover has been well fixed. Otherwise it will cause electric shock.
3. For the solar pump inverters whose storage time is over 1 year, when electrification, the
voltage should be raised by booster from low to high. Otherwise it will damage the solar pump inverter.
Attention
1. Check if all periphery fittings are wired properly according to the handbook; Otherwise it will
cause accidents.
●After Electrification
Danger
1. After electrified, it is forbidden to open the cover, make wiring, and check up; Otherwise, it will
cause the danger of electric shock.
2. After electrified, it is forbidden to contact internal wiring board and its parts. Otherwise it will
cause the danger of electric shock.
3. Do not operate or touch solar pump inverter with wet hand. Otherwise there is danger of
damage to solar pump inverter and electric shock.
SI30 Solar Pump Inverter Manual
3
Attention
1. Please set the parameter of solar pump inverter cautiously; Otherwise it will damage
equipment.
●Operation
Danger
1. Before running, please check and confirm the application range of the machine and
equipment once more; Otherwise it will cause accidents.
2. Please don't touch the cooling fan and braking resistance to check the temperature;
Otherwise there is a danger of getting burn.
3. Unprofessional workers are banned to check the signals in the running stage; Otherwise it
will cause injuries and damage the equipment.
Attention
1. Please don't turn off the equipment by switching off power; Please cut off the power supply
after the electric machine stops running; Otherwise it will damage the solar pump inverter.
2. Please avoid anything dropping into the equipment when the solar pump inverter is running;
Otherwise it will cause electric shock.
●Maintenance
Danger
1. Please don't maintain and repair the equipment with electric; Otherwise it will cause electric
shock.
2. Before maintaining and repairing the solar pump inverter, please make sure the indicator
lights of power supply have completely turned off; Otherwise it may cause electric shock and damage the solar pump inverter.
3. Persons who have not passed specialized train are not allowed to conduct the solar pump
inverter maintenance; Otherwise it may cause electric shock and damage the solar pump inverter.
1.3 Cautions in Using
1. In application of this series solar pump inverter, you have to confirm all machine insulation to prevent damage to the equipment. Moreover, when the motor working in tough environment, please periodic inspect the electrical insulation to ensure the safety of the system work.
2. If the motor adapter is not consistent with solar pump inverter's rating current (The rating current of the motor is far smaller than that of solar pump inverter), please adjust the protective value to ensure safe running.
3. In occasions such as load raises, usually there is negative torque and solar pump inverter breaks off for over-current or over-voltage. In this case, you should consider choosing the matching brake unit.
SI30 Solar Pump Inverter Manual
4
4. Solar pump inverter, in a certain output frequency range, can meet the mechanical resonance of the load equipment. To avoid it, you can set up jumping frequency.
5. As output voltage of the inverter is pulse-wave type, if there is capacity which can improve power factor or pressure-sensitive resistance which used for thunder-proof in the voltage output side, the solar pump inverter will break off or its parts will be damaged, so it is necessary to dismantle them. Moreover, it is proposed not install switch parts like air switch and contactor (if it is necessary to install switch on output side, please make sure the output electricity of solar pump inverter is zero when the switch is working)
6. At over 1,000 meters altitude, the inverter’s heat dissipation function worsened due to the thin air, it is necessary to use less.
7. The inverter output voltage is pulse wave type. If using digital multi-meter measurement, deviation of the reading will be great. And the deviation is different by using different type of digital multi-meter. Under normal circumstances, while RMS 380V, digital multi-meter reading is around 450V.
8. Solar panel can be connected in series or parallel. For rated voltage 380V controller, we suggest solar panel open circuit voltage should be between 620~ 750V.
1.4 Technical Specification
Solar pump
inverter
power(KW)
Pump
Max solar
power input
(KW)
Max DC
input
voltage
(V)
Recommend
Voc voltage
(V)
Rated output
current
(A)
Output
frequenc
y(Hz)
Rated power
(KW)
Rated
voltage
(V)
SI30-D1 series, DC90-400VDC input, 3 phase 110-230VAc output, suit for AC110 pump
0.75
0.75
110
1.0
400
175~380
7A
0-320
1.5
1.5
110
1.95
400
175~380
10A
0-320
SI30-D3 series,DC150V-450V input, 3 phase 220-240VAc output, suit for AC220 pump
0.75
0.75
220
1.0
450
360~430
4A
0-320
1.5
1.5
220
1.95
450
360~430
7A
0-320
2.2
2.2
220
2.86
450
360~430
10A
0-320
SI30-D5 series,DC300V to 800VDC input, 3 phase 230-460VAC output, suit for AC380V pump
0.75
0.75
380
1.0
800
620~750
2.5
0-320
1.5
1.5
380
2.2
800
620~750
3.7
0-320
2.2
2.2
380
3.3
800
620~750
5.0
0-320
4
3.7
380 5 800
620~750
10
0-320
5.5
5.5
380 8 800
620~750
13
0-320
1.5 Cautions in Disposal
When you dispose solar pump inverter, please pay attention to:
1. Electrolytic capacitor: the electrolytic capacitor of main circuit or the printing plate may explode when they are burned.
2. Plastic: plastic incineration may generate toxic gases.
3. Dispose method: please dispose as industrial waste.
SI30 Solar Pump Inverter Manual
5
Chapter 2: Installation and Wiring
2.1 Products Appearance
2.2 Open Cover
Remove 4 fixed screws in the cover and turn from right to left to open the top cover, as shown below:
Remove 4 fixed screws
Turn from right to left to open the top cover
SI30 Solar Pump Inverter Manual
6
2.3 Inverter Dimension
Dimensions for 4 kW and below are shown as follow:
364
446.5
350
285
308
221
270
M6(installation hole)
151.37
SI30 Solar Pump Inverter Manual
7
5.5kW dimension as follow:
285
308
350
364
446.5
195.87
268
250
7.5(installation hole)
299
151.37
195.87
SI30 Solar Pump Inverter Manual
8
2.4
Solar Controller Wiring
Standard Wiring
Note:the function described in brackets is the factory default setting
V
W
U
M
~
Shielded cable or amoured cable (grounding nearby inverter)
E
(Earthing resistance is less than 10Ω)
W
V
U
Output Filter
+10V
Frequency control input
R/L
T/N
S
AC Power Input
AI1
AI2
Twisted-pair shielding cable (grounding nearby by inverter)
Multi-function input terminals
(water fulfilled detection re set)
(water fulfilled detection al arm)
(reversal running)
(forward running)
COM
X3
X4
X1
X2
Solar Pump Inverter
2.AI1/AI2 internal resist ance:75KΩ
1.+10V maximum output:50mA
Note
2.
stands for control circuit terminals.
stands fo main ciruit terminalsr
.
Note
1.
Contactor
Breaker
(
0~10V)/(4~20mA)
+24V
A+
B-
RS485 differential communication
120Ω
Voltage/current analog input
(
0~10V)/(4~20mA)
Voltage/current analog input
GND
P
N
DC Power Input
( )
+
(-)
AC/DC Module
P1
N1
COM
+24V
Maximum output of 24V auxiliary power is 100mA
Control loop terminal instructions
Terminal
Function definition Description
+10V 10V auxiliary power supply output, constitutes loop with GND. MAX output 50mA
+24V 24V auxiliary power supply output, constitutes loop with COM. MAX output 100mA
COM 24V power reference ground MAX output 24VDC/100mA
A+ RS485 communications
+
B- RS485 communications -
AI1 analog input 1 Voltage, current type optional
AI2
analog input 2
Voltage, current type optional
GND
analog signal
ground
X1 Forward running input, and constitutes loop with COM
X2 Reverse running input, and constitutes loop with COM
X3 Full water detection alarm, and constitutes loop with COM
X4 Full water detection reset, and constitutes loop with COM
RJ45 External keyboard connection terminal
SI30 Solar Pump Inverter Manual
9
2.5 Terminal diagram
D3 model with output filter D5 model with output filter
+
_
L N
U V W
U1
V1
W1
U1V1W1
+
_
S
T
U V W
U1
V1
W1
U1V1W1
R
SI30 Solar Pump Inverter Manual
10
Inverter board terminal diagram Terminal diagram of control panel
U1
V1
W1
+
_
Loading...
+ 22 hidden pages