Introduction
Within the Danaher Controls A103 family you'll find a product to meet nearly every
requirement for panel mounted control and indication. Housed in a DIN standard 36mm x
72mm case, the A103-000 meets the requirements for basic count totalization applications.
No required programming leads to plug-and-play simiplicity and minimal installation time.
The 8 digit supertwist LCD display provides easy viewing at a glance. For conditions where
ambient light is poor, the display can be backlit by connecting an external DC (10-28 Volt)
power supply. A single unit can accept NPN & dry contact inputs for low speed (30Hz)
counting and PNP or square wave signals for high speed applications up to 10 kHz.
Powered by either one or two replaceable 3V Lithium batteries, this unique design allows for
a new battery to be installed before removing the old one, thereby retaining count total and
program data. A low battery indicator appears on the screen to provide a warning several
weeks before the end of battery life. If two batteries are used simultaneously, the individual
expected life doubles to 10 years.
A NEMA 4X rating and a high
level of noise immunity make this
unit sutiable for harsh
environments. Several option
modules are also available that
provide added functionality and
convenience.
Technical Manual
701954-0001
Features
•
Large, easy to read 8-digit supertwist LCD
with backlighting capability
•
3 Volt lithium battery provides long life
and eliminates the need for external power
•
Accepts low speed (30 Hz) NPN & dry
contact inputs, and high speed (10 kHz)
PNP signals or square wave signals
•
Total value resettable remotely or from the
front panel
•
Option Modules provide added
functionality and convenience
•
Plug-and-Play simplicity
•
NEMA 4X rated front panel for use in
washdown environments
Index
Overview
Setup
General
Operation page 2
Terminal Connections page 2
Installation page 3
Specifications page 3
Warranty page 4
Veeder-Root
brand
A103-000
Totalizer
1
OVERVIEW
OPERATION
VEEDER-ROOT
12345678
RST
1. Total Display
1. Total Display: Indicates the present count value, which is equal to
the number of pulses received since the last reset.
REAR TERMINAL CONNECTIONS
2. Reset Key
2. Reset Key: Resets the current count value when the Front Panel
Reset Enable Input (Terminal 5) is also active.
VEEDER-ROOT
4
3
+
-
2
1
1. Common
2. High Speed Input - PNP or squre
wave signals up to 10 kHz*
3. Low Speed Input - NPN or dry
contact inputs up to 30 Hz
4. Remote Reset - Resets count value
when switched to common
2
5
6
7
10 - 28 VDC
8
5. Front Panel Reset Enable - Enables the count
value to be reset through depressing the front
panel Reset key
6. Not Used
7. Not Used
8. DC Supply Input - For backlighting
* For high speed current sinking devices, provide a pull-up