Vector MAXX SST VEC049GM, MAXX SST VEC050GM, MAXX SST VEC051GM User's Manual & Warranty Information

16
VEC049GM VEC050GM VEC051GM
USER’S MANUAL
& WARRANTY INFORMATION
IMPORTANT SAFETY INFORMATION, SAVE THESE INSTRUCTIONS
TO REDUCE THE RISK OF INJURY, USER MUST READ AND UNDERSTAND THIS INSTRUCTIONAL MANUAL. THIS MANUAL CONTAINS IMPORTANT INFORMATION REGARDING THE OPERATION AND WARRANTY OF THIS PRODUCT. PLEASE RETAIN FOR FUTURE REFERENCE.
www.vectormfg.com
4140 S.W. 30th Ave., Ft. Lauderdale, FL 33312
Toll Free: (866) 584-5504
MAXX SST
Portside Power Inverters
Converts 12 Volt DC to 110/120 Volt AC
Advanced MOSFET Technology
VEC050GM VEC051GM
VEC049GM
Power Inverter Model
*
.
Maximum Continuous Power 1000 watts 1500 watts 3000 watts
Surge Capacity (Peak Power) 2000 watts 3000 watts 6000 watts
No Load Current Draw (switch on) 1.7 amp 2.3 amp 2.8 amps
Maximum Efficiency (approx.) 90% 90% 90%
Input Voltage 10.5–15.5 VDC 10.5–15.5 VDC 10.5–15.5 VDC
Output Voltage 110/120 VAC 60 Hz 110/120 VAC 60 Hz 110/120 VAC 60 Hz
Low Voltage Alarm <10.6 VDC <10.6 VDC <10.6 VDC
Low Voltage Shutdown 10.0 VDC Auto Reset 10.0 VDC Auto Reset 10.0 VDC Auto Reset
Over Voltage Shutdown >15.5 VDC >15.5 VDC >15.5 VDC
Thermal Shutdown Auto Reset YES YES YES
Wave Form Modified Sine Wave (MSW) YES YES YES
Proper Cable Gauge (AWG) @ 6 FT. #3 #2 2/0
Proper Cable Gauge (AWG) @ 10 FT. #1 2/0 250 mcm
North American Standard Outlets 2 GFCI Protected Outlets 2 GFCI Protected Outlets 4 GFCI Protected Outlets
ANL Fuse Rating for Direct Hardwire 200 300 500
*For lengths greater than 10 FT., contact Vector's Technical Support, toll-free, at (866) 584-5504
1. These models feature multiple U ground 120 volt AC outlets
2. All of these inverters meet North American Standard Requirements.
3. All units feature Siemens Mosfet Power Transistors
SPECIFICA
TIONS
VEC049_50_51GM_Manual_041906 4/20/06 4:09 PM Page 16
Important Cable Information
Substantial power loss and reduced battery operating time results from inverters installed with cables that are not able to supply full power. Symptoms of low battery power can result from cables that are either excessively long or an insufficient gauge. Marine installations are also subjected to vibration and stresses that exceed those of other mobile installations. Therefore, the installer/operator should be especially aware of the requirements to maintain secure, tight, water-resistant electrical connections and to provide for strain relief for DC cables and appliance wiring. Cable insulation must be the appropriate type for the environment.
Read All Instructions Before Using This Power Inverter!
SAVE THESE INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS
WARNINGS TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, EXPLOSION OR INJURY:
• NEVER connect to AC distribution wiring.
• Remove appliance plug from outlet strip or turn off inverter before working on the appliance. Multiple outlet power strips with switches and circuit breakers only interrupt power to the "hot" receptacle terminals. The "neutral" terminals remain powered with respect to the "ground" terminals.
• NOT approved for ignition protected areas. Do not make any electrical connections or disconnections in areas designated as IGNITION PROTECTED.
• This equipment employs components that tend to produce arcs or sparks. DO NOT install in compartments containing batteries or flammable materials.
• Use this unit in properly ventilated areas ONLY.
• Do not open — there are no user-serviceable parts inside.
• Do not insert foreign objects into the outlets.
• Do not expose the unit to liquids, including water, rain or snow.
• This is not a toy — keep away from children.
CAUTIONS
• Always inspect battery supply connections and cables to ensure they are tight and that cable insulation is not damaged.
• Do not use with positive ground electrical systems*. Reverse polarity connection will result in a blown fuse and may cause permanent damage to the inverter and will void warranty.
*The majority of modern automobiles, RVs, trucks and boats are negative ground.
• Grounding the Neutral will cause the inverter to shut down. Do not operate this inverter if it is wet. Do not install in engine compartment — install in a well ventilated area.
• This inverter has not been not tested for use with medical devices.
• Do not attempt to install or operate this unit while operating a motor vehicle.
APPLIANCE CAUTIONS
NEVER plug small appliances directly into the inverter outlets to recharge nickel-cadmium batteries. Always use the charger provided with the appliance.
NEVER plug in battery chargers for cordless power tools if the charger carries a warning that dangerous voltages are present at the battery terminals.
Certain chargers for small nickel-cadmium batteries can be damaged if plugged into the inverters. DO NOT use inverters with the following two types of equipment.
1. Small, battery-operated appliances such as flashlights, cordless razors and toothbrushes that can be plugged directly into an AC receptacle to recharge.
2. Battery chargers that have a warning label stating that dangerous voltages are present at the battery terminals.
The majority of portable appliances do not have this problem. Most portable appliances use separate transformers or chargers that plug into AC receptacles to supply a low DC or AC voltage output to the appliance. If the appliance label states that the charger or adapter produces a low DC or AC voltage output (30 volts or less), there should be no problem powering that charger or adapter.
Some fluorescent lamps may not operate properly with this type of inverter. If the bulb appears to be too bright, or fails to light, do not use the lamp with this inverter.
Some fans with synchronous motors may slightly increase in speed (RPM) when powered by the inverter. This is not harmful to the fan or to the inverter.
VEC049_50_51GM_Manual_041906 4/20/06 4:09 PM Page ii
1
TABLE OF CONTENTS
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
VEC049GM Functions and Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
VEC050GM Functions and Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
VEC051GM Functions and Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
MAXX SST™Portside Power Inverter Safety Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Principle of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Appliance Power Consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Appliance Consumption in Amps and Watts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Operating Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Power Source Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Determining Battery Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Runtime . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Protective Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Operating Environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Marine Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Installation Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Connection To Load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Operating Tips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Notes on Using the Remote Control (sold separately) . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Care and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Fuse Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Preventive Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Common Audio/Visual Problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Resetting the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Fault Protection and Troubleshooting Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
INTRODUCTION
Thank you for purchasing a
Vector MAXX SST™Portside Power Inverter.
Please read this guide carefully before use to ensure optimum performance and to avoid damage to this product.
This Power Inverter is configured with the latest Soft Start Technology (SST) and supplies continuous power in the form of 120 volt AC outlets to run most household or electronic appliances. Before introduction of SST, high start-up currents from large inductive loads could shut down an inverter. SST improves inverter operation by:
• Gradual voltage ramp-up during inver ter start-up, eliminating failed cold starts under load.
• Output that momentarily dips in voltage and quickly recovers to allow large motorized loads to start, eliminating most shutdowns from momentary overloads.
• A new technology that cools the power transistors more efficiently, and, combined with Soft Start, dramatically increases reliability and life of the product.
Added safety features include automatic shutdown and a low battery alarm to prevent damage to your battery.
FEATURES
Portside Power Inverters are supplied with:
• Rubber grommets for vibration immunity and secure bulkhead mounting.
• Grounding terminals for electrical safety.
TWO YEAR LIMITED WARRANTY PROGRAM
This limited warranty program is the only one that applies to this product, and it sets forth all the responsibilities of Vector Products, Inc., regarding this product. There is no other warranty, other than those described herein. Any implied warranty of merchantability or fitness for a particular purpose on this product is limited in duration to the duration of this warranty.
This Vector Products, Inc. product is warranted, to the original purchaser only, to be free of defects in materials and workmanship for two years from the date of purchase without additional charge. The warranty does not extend to subsequent purchasers or users. Manufacturer will not be responsible for any amount of damage in excess of the retail purchase price of the product under any circumstances. Incidental and consequential damages are specifically excluded from coverage under this warranty.
This product is not intended for commercial use. This warranty does not apply to damage to units from misuse or incorrect installation/connection. Misuse includes wiring or connecting to improper polarity power sources.
RETURN/REPAIR POLICY: Defective products may be returned to manufacturer. Any defective product that is returned to manufacturer within 30 days of the date of purchase will be replaced free of charge. If such a product is returned more than 30 days but less than two years from the purchase date, manufacturer will repair the unit or, at its option, replace it, free of charge.
If the unit is repaired, new or reconditioned replacement parts may be used, at manufacturer’s option. A unit may be replaced with a new or reconditioned unit of the same or comparable design. The repaired or replaced unit will then be warranted under the terms of the remainder of the warranty period. The customer is responsible for the shipping charges on all returned items. During the warranty period, manufacturer will be responsible for the return shipping charges to the customer in the United States.
LIMITATIONS: This warranty does not cover accessories, such as charging adapters, bulbs, fuses and batteries, damage or defects resulting from normal wear and tear (including chips, scratches, abrasions, discoloration or fading due to usage or exposure to sunlight), accidents, damage during shipping to our service facility, alterations, unauthorized use or repair, neglect, misuse, abuse, failure to follow instructions for care and maintenance, fire, flood and Acts of God.
If your problem is not covered by this warranty, call our Technical Support Department at (954) 584­4446 or toll free at (866) 584-5504 for general repair information and charges if applicable. You may also contact us through our website at www.vectormfg.com.
STATE LAW RIGHTS: This warranty gives you specific legal rights. Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages, so the exclusions or limitations stated herein may not apply. This warranty gives the purchaser specific legal rights; other rights, which vary from state to state, may apply.
TO REQUEST WARRANTY SERVICE FOR THIS PRODUCT: Contact Technical Support by telephone, fax or mail (see below). We suggest that you keep the original packaging in case you need to ship the unit. When returning a product, include your name, address, phone number, dated sales receipt (or copy) and a description of the reason for return and product serial number. After repairing or replacing the unit, we will make every effort to return it to you within four weeks.
WARRANTY ACTIVATION: Please complete Warranty Activation Card and mail to Vector Products, Inc.. Enter the appropriate model number as Model and “MAXX SST
Portside Power Inverter” as Product Type. All Vector products must be registered within 30 days of purchase to activate this warranty. Mail the completed registration form, along with a copy of the original sales receipt, to:
ATTN.: CUSTOMER SERVICE
4140 SW 30th Ave., Ft. Lauderdale, FL 33312
• TOLL FREE: (866 ) 584-5504 • FAX: (954) 584-5556 •
WARRANTY IS NON-TRANSFERABLE.
BD041206
© 2006 VECTOR PRODUCTS, INC.
MADE IN CHINA
VEC049_50_51GM_Manual_041906 4/20/06 4:09 PM Page iv
Loading...