Vector GL2000, GL2010, GL2000 Series, GL2400 User Manual

User Manual GL2000/GL2010
Version English
– Data Logger
2.4
Imprint
Vector Informatik GmbH Ingersheimer Straße 24
D
Vector reserves the right to modify any information and/or data in this user documentation without notice. This documentation nor any of its parts may be reproduced in any form or by any means without the prior written consent of Vector. To the under law, all technical data, texts, graphics, images and their design are protected by copyright law, various international other applicable law. Any unauthorized use may violate copyright and other applicable laws o © Copyright 201 All rights reserved.
-70499 Stuttgart
maximum extent permitted
7, Vector Informatik GmbH. Printed in Germany.
r regulations.
treaties and
User Manual GL2000/GL2010 – Data Logger Table of Contents
Table of Contents
1 Introduction 3
1.1 About this User Manual 4
1.1.1 Certification 5
1.1.2 Warranty 5
1.1.3 Support 5
1.1.4 Trademarks 5
2 GL2000 – Data Logger 7
2.1 General Information 8
2.2 Features 9
2.2.1 Connectors 9
2.2.2 SD/SDHC Memory Card 12
2.2.3 Serial Number 14
2.2.4 LED Display 15
2.2.5 Digital Input/Output 16
2.2.6 Analog Inputs 17
2.2.7 Serial Interface 17
2.2.8 Real Time Clock with Battery 17
2.2.9 Beep 19
2.2.10 Wake-up / Sleep 19
2.2.11 CCP/XCP 20
2.2.12 Diagnostics 21
2.3 Operating Modes 21
2.4 CAN and LIN 22
2.4.1 CAN 22
2.4.2 CAN Piggybacks 22
2.4.3 LIN 24
2.5 GPS Mouse 25
2.6 Ethernet 25
2.7 3G (UMTS) 26
2.8 Technical Data 27
2.9 Included with Delivery 28
2.10 Accessories 28
3 Installation Configuration Programs 29
3.1 Overview 30
3.2 Installation Vector Logger Configurator 30
3.2.1 Requirements 30
3.2.2 Setup 31
3.2.3 Overview 31
3.2.4 Quick Start 32
3.3 Installation G.i.N. Configuration Program 33
3.3.1 Requirements 33
3.3.2 Setup 33
3.3.3 Overview 33
3.3.4 Quick Start 34
4 Index 37
© Vector Informatik GmbH Version 2.4 - I -
User Manual GL2000/GL2010 – Data Logger Table of Contents
© Vector Informatik GmbH Version 2.4 - II -
User Manual GL2000/GL2010 – Data Logger Introduction

1 Introduction

In this chapter you find the following information:
1.1 About this User Manual page 4 Certification Warranty Support Trademarks
© Vector Informatik GmbH Version 2.4 - 3 -
User Manual GL2000/GL2010 – Data Logger Introduction
The user manual provides you the following access helps:
> At the end of the user manual you will find an index.
regarding utilized spellings and symbols.
Source code
Here you can find additional information.
Step-by-step instructions provide assistance at these points.
Instructions on editing files are found at these points.

1.1 About this User Manual

To find information quickly
> At the beginning of each chapter you will find a summary of the contents,
> In the header you can see the current chapter and section,
> In the footer you can see to which version the user manual replies,
Conventions
In the two following charts you will find the conventions used in the user manual
Style Utilization
bold
Windows Legally protected proper names and side notes.
Hyperlink Hyperlinks and references.
<STRG>+<S> Notation for shortcuts.
Symbol Utilization
Blocks, surface elements, window- and dialog names of the software. Accentuation of warnings and advices.
[OK] Push buttons in brackets File | Save Notation for menus and menu entries
File name and source code.
Here you can find additional information and hints that eases the work with the loggers.
This symbol calls your attention to warnings.
Here is an example that has been prepared for you.
This symbol warns you not to edit the specified file.
© Vector Informatik GmbH Version 2.4 - 4 -
User Manual GL2000/GL2010 – Data Logger Introduction
Management System
The ISO standard is a globally recognized standard.
the contents and for damages which may result from the use of this documentation.
or you write an email to support@vector.com.
trademarks
trademarks of their respective owners.

1.1.1 Certification

Certified Quality
Vector Informatik GmbH has ISO 9001:2008 certification.

1.1.2 Warranty

Restriction of warranty
We reserve the right to modify the contents of the documentation or the software without notice. Vector disclaims all liabilities for the completeness or correctness of

1.1.3 Support

You need support? You can get through to our hotline at the phone number
+49 711 80670-200

1.1.4 Trademarks

Protected
All brand names in this documentation are either registered or non registered
© Vector Informatik GmbH Version 2.4 - 5 -
User Manual GL2000/GL2010 – Data Logger GL2000 – Data Logger

2 GL2000 – Data Logger

In this chapter you find the following information:
2.1 General Information page 8
2.2 Features page 9 Connectors SD/SDHC Memory Card Serial Number LED Display Digital Input/Output Analog Inputs Serial Interface Real Time Clock with Battery Beep Wake-up / Sleep CCP/XCP Diagnostics
2.3 Operating Modes page 21
2.4 CAN and LIN page 22 CAN CAN Piggybacks LIN
2.5 GPS Mouse page 25
2.6 Ethernet page 25
2.7 3G (UMTS) page 26
2.8 Technical Data page 27
2.9 Included with Delivery page 28
2.10 Accessories page 28
© Vector Informatik GmbH Version 2.4 - 7 -
User Manual GL2000/GL2010 – Data Logger GL2000 – Data Logger
configuration program. The installation is described in chapter 3.
eliminated.
Support.

2.1 General Information

GL2000 The GL2000 is a data logger with USB interface which processes CAN messages
with either 11-bit or 29-bit identifiers and LIN messages. Furthermore, received messages and analog values can be logged on an inserted SD/SDHC card. The configuration of the logger is done with the Vector Logger Configurator or the G.i.N.
GL2010
The GL2010 is equivalent to the GL2000 and differs only in the design of the housing and the connections (watertight according to IP65). The SD card is located in the housing and is no longer accessible from the outside. The opening for the speaker is
Note: Please note that the housing of the GL2010 must not be opened under any
circumstances, since otherwise the IP65 protection class of the data logger is no longer guaranteed. The SD/SDHC card, the piggybacks, and the battery may only be replaced by Vector Informatik GmbH. For more information, please contact the Vector
Figure 1 – GL2000 (left), GL2010 (right)
Info: Due to the openings in the housing for the LED, leak tightness may not be
guaranteed if the label is damaged.
© Vector Informatik GmbH Version 2.4 - 8 -
User Manual GL2000/GL2010 – Data Logger GL2000 – Data Logger
> Event connector for switch box E2T2L (GL2000 V2.0 only)
pin assignment
included connection cable Vehicle.
the power supply ground.

2.2 Features

2.2.1 Connectors

General information The loggers have the following connectors:
> USB connector: data transfer between PC and logger
> DSUB25 connector Vehicle containing:
4 CAN channels 2 LIN channels 2 digital inputs/outputs 4 analog inputs Battery and ground Ignition
> DSUB15 connector Extension containing:
2 digital inputs/outputs GPS module Switch box External supply for galvanically isolated piggybacks
> SD/SDHC card slot (externally accessible)
> AUX connection for logger accessories
DSUB25
The pins of the Vehicle connector have the following meaning. The colors refer to the
Pin Assignment Color Pin Assignment Color
1 Battery (VCC) white 14 CAN3 Low white/blue
2 RS232 Rx white/green 15 CAN1 High yellow
3 RS232 Tx brown/pink 16 CAN1 Low green
4 GND brown 17 CAN4 High white/gray
5 Battery (VCC) white/black 18 CAN4 Low white/pink
6 I/O 1 white/yellow 19 CAN2 High grey
7 GND brown/red 20 Wake/KL15 black
8 I/O 2 brown/yellow 21 CAN2 Low pink
9 Analog In 1 grey/pink 22 GND brown/blue
10 Analog In 2 red/blue 23 LIN 1 lilac
11 Analog In 3 blue 24 LIN 2 red
12 Analog In 4 brown/green 25 K-Line brown /gray
13 CAN3 High white/red
© Vector Informatik GmbH Version 2.4 - 9 -
The three GND pins are connected together internally and have the same potential as
User Manual GL2000/GL2010 – Data Logger GL2000 – Data Logger
ground (GND) pins of the two voltage supplies must be connected.
Vehicle
following connections.
time the EMC properties are improved.
pin assignment
internally and have the same potential as the power supply ground.
You can find further information about the GPS mouse in chapter 2.5.
Caution: It is recommended to connect the logger to the same voltage supply (e.g.
battery of the vehicle) as the vehicle or test equipment, respectively.
If two different voltage supplies are used for the logger and the test equipment, the
Connection cable
DSUB15
In the delivery a connection cable for the Vehicle connector is included with the
CAN1
CAN2
LIN1
V
/KL30
batt
GND
Wake/KL15
DSUB9 with black cap
DSUB9 with red cap
DSUB9 with yellow cap
red pin plug
black pin plug
red pin plug
All other wires have open wire ends. If these wires are not used, it is recommended to terminate them. This prevents short circuits between the open wires. At the same
Note: The connecting cable does not conform to IP65.
The pins of the Extension connector have the following meaning.
Pin Assignment Pin Assignment
Connection cable Extension (not for GL2000 V2.0)
1 CAN3_Vbatt 9 CAN3_GND
2 CAN4_Vbatt 10 CAN4_GND
3 LIN1_Vbatt (24V) 11 I/O 4
4 LIN2_Vbatt (24V) 12 V+ (switch box)
5 I/O 3 13 T1 (switch box)
6 V+ (GPS) 14 T2 (switch box)
7 Rx (GPS) 15 GND
8 Tx (GPS)
The four GND pins on the connectors Vehicle and Extension are connected together
In the delivery a connection cable for the Extension connector is included.
The delivered switch box E2T2L is connected to the 5-pin Binder connector. The PS2 connector is provided for an optional serial GPS mouse. The contacts for further pins are loosely added.
© Vector Informatik GmbH Version 2.4 - 10 -
User Manual GL2000/GL2010 – Data Logger GL2000 – Data Logger
programmable.
The plug pin assignment is as follows (view of the contacts of the logger plug):
2
3.3 V
5
T
connection of the following logger accessories:
not supported)
Note: The connecting cable does not conform to IP65.
Event connection (GL2000 V2.0 only)
Switch Box wiring
This plug is used for the connection of the switch box E2T2L with two buttons and two LEDs, which is included in the scope of delivery. The buttons and the LEDs are freely
Pin Assignment
1 NC
3 A
4 B
AUX connection
© Vector Informatik GmbH Version 2.4 - 11 -
The additional 5-pin plug connection (connector series 711) AUX is intended for the
> LOGview (external display)
> Switch Box CAS1T3L (with one button, three LEDs and one sound)
> Switch Box CASM2T3L (with two buttons, three LEDs, one sound, and
microphone for voice recording)
> VoCAN (with one button, four LEDs. microphone for voice recording, voice output
Loading...