Vectaire ELIX 1003, ELX1003LV, ELX1003DTLV, ELX1003DT, ELX1003HDT Installation And Operating Instructions Manual

...
ELIX 1003
Energy Efficient Centrifugal Fan with EC Motor
Installation and Operating Instructions
• 6 models:
- SAP Appendix Q Eligible 3 speed continuous running
- timer
- humidity control
- SELV - low voltage
• for all domestic wet rooms
• for walls or ceilings
Elix 1003” - CENTRIFUGAL FANS WITH EC MOTOR
" INSTALLATION and OPERATING INSTRUCTIONS
THIS LEAFLET MUST BE AVAILABLE TO THE USER
The product you have purchased is an extractor fan for exhausting directly outside or through longer lengths of ducting (up to 15m) and is suitable for wall or ceiling installation. To ensure optimum opera­tion and guarantee a long life, please read this manual carefully. It explains how to install correctly, use and maintain the product prop­erly. Following these instructions will ensure the reliability of the prod-
ct and extend its working life.
u
The manufacturer will not accept any responsibility for damage caused to persons or things due to improper use with reference to the precautions outlined in this leaflet.
The product, constructed using state of the art technology, complies with current standards regarding electrical equipment. It conforms with the EMC 2004/108/EC European Directive regarding radio interference suppression and electro-magnetic compatibility.
WARNING: Serious injury or death could result if these instructions are not carefully followed
Do not use this product for any purpose other than that for which
it was designed.
Remove the product from its packaging and make sure that it
has not been damaged. If in doubt, contact the supplier, autho­ rised dealer, service centre or manufacturer to check that the product will still operate correctly. Do not attempt to use or re­ pair the product before doing this.
Do not leave packing material within the reach of children or un-
skilled people. To dispose of the packaging and the appliance at the end of its useful life refer to the recycling rules in force.
The use of any electrical product requires compliance with some
basic rules which are listed below:
- do not touch it with wet or damp parts of the body (e.g hands,
feet).
- this product is not intended for use by persons (including chil-
dren) with reduced physical, sensory or mental capabilities or lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the product by a person responsible for their safety. The fan should be sited where it is inaccessible to such people.
- children should be supervised to ensure they do not play with
the product.
• The product should be connected to the mains electricity supply or electrical outlet only if:
- the electrical voltage and frequency correspond to those
shown on the rating label.
- the capacity of the electricity supply is sufficient to operate the
product at its maximum power.
- suitable electrical protection is provided for the product to be
installed.
• The electrical supply to which the fan is connected must comply with all existing regulations. All installations must comply with current IEE wiring regulations.
• Before maintenance or cleaning is carried out, the product must be switched off and disconnected from the mains electricity sup­ ply.
• If a fault, malfunction or anomaly of any type occurs, the fan should be isolated (switching it off and disconnecting it from the mains electricity supply) and advice sought from qualified personnel.
• Always request original spare parts for repairs
• If the product needs to be removed, turn off the mains supply and then disconnect the fan.
• The fan MUST BE installed as detailed in this leaflet
WARNING: Damage could be caused to the product if the instal­lation instructions are not followed
• The product should not be used in an ambient temperature higher than 40°C (104°F).
• The product should not be exposed to atmospheric agents (rain, sun, snow, etc.).
• The product or its parts should not be placed in water or other liquids.
• Routine maintenance as described should be carried out to
2
check the condition of the fan.
• The air or fumes being extracted must be clean and free from greasy particles, soot, chemical and corrosive agents, flamma­ ble or explosive mixtures.
The product must be installed by professionally qualified per-
sonnel. Incorrect installation can cause damage to people,
animals or property, for which the manufacturer cannot be
held liable.
The product must be connected to the electricity supply via a
• double pole switch of a suitable size, with contact openings of at least 3 mm.
• If the electrical supply board (or switching device) is located some distance from the fan a means of local isolation must be provided.
To ensure optimum operation, do not block the air intake and
• exit vents.
• Any ducting used must be free of blockages, and should be insu­ lated if in an unheated area.
• The room where the product is operating must have adequate air replacement to ensure maximum effectiveness.
• If the product is sited in a room containing a fuel burning appli­ ance which is not of the balanced flue type, the installer must en­ sure that air replacement is adequate both for the fan and the fuel burning appliance (UNI CIG 7129).
• The product must not be used as an activator for water heaters, stoves, etc.
• The product must not exhaust into ducts designed to evacuate fumes from combustion in stoves or other combustion-powered devices.
RANGE
Trickle Speed 1- 8 lt/sec - 28.8 m³/h Trickle Speed 2 - 14 lt/sec - 50.4 m³/h
ELX1003 - this fan combines the latest technology with energy
saving and efficiency. It is a quiet running, 3 speed fan. It is de­signed to run continuously at a pre-selectable choice of 2 trickle speeds (fixed at installation). The user can boost the fan speed to its maximum performance when required by means of the cord or remove the cord and use a remote switch, light switch, PIR sensor or humidistat. If the fan is to be ceiling mounted, the pull-cord
switch should be put in the “off” position and the cord removed. A remote switch will be necessary for changing the fan speed. See wiring diagrams, page 4.
Carol Auster.
The ELX1003 is SAP Appendix Q Listed
ELX1003LV - SELV, 12v version ELX1003.
ELX1003DT - 3 speed, continuous running fan with delay-on timer
and pull cord. The delay-on timer version will run at low speed until the boost speed is activated by means of the cord or, if the cord is removed, by means of a remote switch, light switch, PIR sensor or humidistat. There is a 2 minute delay before the fan starts to run at its high speed - if the boost speed is deactivated before that time lapse, the fan will continue to run at low speed. If the boost speed is activated, the fan will operate at high speed until the boost switch is turned off. After this, the fan will continue at high speed for the length of time set on the timer overrun adjustment, between 0 and 30 mins. (See page 5). After the overrun time has elapsed, the fan will return to the slower speed.
ELX1003DTLV - SELV, 12v version of ELX1003DT
ELX1003HDT - 3 speed, continuous running fan. The fan runs
continuously at the pre-selected lower speed, and the boost (speed
2) will start to operate automatically when the relative humidity
(adjustable between 40% and 90% +/-5% tolerance) reaches the pre-set level and will continue to operate at this speed until the hu­midity has been dispersed and the adjustable over-run timer (ad­justable from 0 to 30 minutes) has completed its cycle. The boost speed can also be activated by as described for model EL1003DT
ELX1003HDTLV - SELV, 12v version of ELX1003HDT
INSTALLATION
1
4
2
5
7
3
6
8
9
1. Check there is nothing missing in box and re-
move front cover.
2. Drill hole in wall - allow extra width if using
ducting - it is the installer's responsibility to use the appropriate core cutter to ob­tain the correct hole diameter.
3. Remove circuit board cover.
4. Use fan assembly as template to mark drill
holes.
5. Drill 4 x 6mm dia holes.
6. Fit wall plugs.
12
7/8 Decide whether to have cable access from
rear (recessed) or top (surface) of fan - if
IMPORTANT
If the fan is installed in a ceiling with a vertical duct passing through an unheated space, a condensation trap MUST be fitted. Any ducting in an unheated space should also be insulated accord­ing to the latest Building Regulations recommendations in the Domestic Ventilation Compliance Guide. Failure to do this could result in condensation affecting the op­eraItion of the fan and cause damage to the ceiling.
10
from top ensure that included grommet is properly fixed. (See dia 8). If cable is to come through rear of fan, fit rubber ring (in cluded) .
9. Screw fan to wall
10. Connect cable using cable clamp - SEE
WIRING DIAs FOR SPECIFIC MODELS NB this fan is double insulated and does not need to be earthed
11. Before replacing circuit board cover
choose speed of fan and set delay-on
timer (if applicable)
SEE JUMPER SWITCH SETTINGS BELOW
12. Replace front cover.
If the fan is to be ceiling mounted, the pull-cord switch should be put in the “off” position and the cord removed. A remote switch will be necessary for changing the fan speed. See wiring dia­grams, page 4.
3
11
JUMPER SWITCH
These fans are designed to run continuously at one of two trickle speeds fixed at installation using the jumper switch. The configurations for the various models are:
ELX1003
ELX1003HDT N.B to activate delay-on timer remove Jumper 3 ELX1003LV
ELX1003DT N.B to activate delay-on timer remove Jumper 3
ELX1003DTLV N.B to activate delay-on timer remove Jumper 3
WIRING DIAGRAMS
ELXs - 3 Speed with Cord
SELV with Pull Cord Switch ELX1003LV - 3 Speed with Cord ELX1003DTLV - 3 Speed with Timer and Cord ELX1003HDTLV - 3 Speed with Humidistat, Timer and Cord
ELX1003HDTLV N.B to activate delay-on timer remove Jumper 3
ELXs - 3 Speed via remote switch
SELV with External Switch ELX1003LV - 3 Speed ELX1003DTLV - 3 Speed with Timer ELX1003HDTLV - 3 Speed with Humidistat and Timer
SELV Products
All SELV (safety extra low voltage) products must be installed to conform to IEC 60364.
• Connection between the fan and the mains supply must be by means of a safety isolating transformer of the appropriate power rating
• The transformer should be connected to the mains supply via a double pole safety switch with a contact opening of at least 3mm
• The transformer will operate only one fan
• The transformer must not be installed in Zones 1 or 2, but should be installed as close as possible to the fan within Zone 3
• The cable used to connect the transformer to the fan must have a section area of at least 1.5mm
2
and a maximum length
of 10m
• If the fan is a humidity control model, it must be installed using the transformer supplied for that product.
4
TRIMMER ADJUSTMENT
To adjust the humidistat and timer trimmers, remove the front cover and circuit board cover of the fan to access the trimmers.
The humidistat (HY) can be adjusted between 40% and 90% relative humidity. Turn clockwise to decrease sensitivity and set at a higher level of relative humidity.
The timer (T) is adjustable between 0 and 30 minutes. Turn the trimmer clockwise to increase the overrun time, or anti-clockwise to decrease it.
MAINTENANCE
efore any maintenance
B or cleaning operation, switch off the fan and dis­connect it from the main
ower supply. The filter
p can be easily removed and carefully washed. The front cover can be cleaned with a dry cloth or soft brush. The fan must not come into contact with any kind of liquid or solvent. If this should occur, con­tact a qualified technician before reassembling the fan.
NOTE: The motor does not require lubrication as it is maintenance free "sealed for life" type
DISMANTLING & RECYCLING -
.
and components that can be recy
This product has been designed and constructed using high-quality materials
cled or re-used.
Vectaire Ltd, Lincoln Road, Cressex Business Park, High Wycombe, Buckinghamshire, HP12 3RH
Tel: +44 (0)1494 522333. Fax: +44 (0)1494 522337.
Email: sales@vectaire.co.uk Web: www.vectaire.co.uk
E & O.EElix 1115 5FI2214