Elix 1003” - CENTRIFUGAL FANS WITH EC MOTOR
"
INSTALLATION and OPERATING INSTRUCTIONS
THIS LEAFLET MUST BE AVAILABLE TO THE USER
The product you have purchased is an extractor fan for exhausting
directly outside or through longer lengths of ducting (up to 15m) and
is suitable for wall or ceiling installation. To ensure optimum operation and guarantee a long life, please read this manual carefully. It
explains how to install correctly, use and maintain the product properly. Following these instructions will ensure the reliability of the prod-
ct and extend its working life.
u
The manufacturer will not accept any responsibility for damage
caused to persons or things due to improper use with reference
to the precautions outlined in this leaflet.
The product, constructed using state of the art technology, complies
with current standards regarding electrical equipment. It conforms
with the EMC 2004/108/EC European Directive regarding radio
interference suppression and electro-magnetic compatibility.
WARNING: Serious injury or death could result if these instructions are
not carefully followed
• Do not use this product for any purpose other than that for which
it was designed.
• Remove the product from its packaging and make sure that it
has not been damaged. If in doubt, contact the supplier, autho rised dealer, service centre or manufacturer to check that the
product will still operate correctly. Do not attempt to use or re pair the product before doing this.
• Do not leave packing material within the reach of children or un-
skilled people. To dispose of the packaging and the appliance at
the end of its useful life refer to the recycling rules in force.
• The use of any electrical product requires compliance with some
basic rules which are listed below:
- do not touch it with wet or damp parts of the body (e.g hands,
feet).
- this product is not intended for use by persons (including chil-
dren) with reduced physical, sensory or mental capabilities or
lack of experience and knowledge, unless they have been given
supervision or instruction concerning the use of the product
by a person responsible for their safety. The fan should be
sited where it is inaccessible to such people.
- children should be supervised to ensure they do not play with
the product.
• The product should be connected to the mains electricity supply
or electrical outlet only if:
- the electrical voltage and frequency correspond to those
shown on the rating label.
- the capacity of the electricity supply is sufficient to operate the
product at its maximum power.
- suitable electrical protection is provided for the product to be
installed.
• The electrical supply to which the fan is connected must comply
with all existing regulations. All installations must comply with
current IEE wiring regulations.
• Before maintenance or cleaning is carried out, the product must
be switched off and disconnected from the mains electricity sup ply.
• If a fault, malfunction or anomaly of any type occurs, the fan should
be isolated (switching it off and disconnecting it from the mains
electricity supply) and advice sought from qualified personnel.
• Always request original spare parts for repairs
• If the product needs to be removed, turn off the mains supply
and then disconnect the fan.
• The fan MUST BE installed as detailed in this leaflet
WARNING: Damage could be caused to the product if the installation instructions are not followed
• The product should not be used in an ambient temperature
higher than 40°C (104°F).
• The product should not be exposed to atmospheric agents (rain,
sun, snow, etc.).
• The product or its parts should not be placed in water or other
liquids.
• Routine maintenance as described should be carried out to
2
check the condition of the fan.
• The air or fumes being extracted must be clean and free from
greasy particles, soot, chemical and corrosive agents, flamma ble or explosive mixtures.
• The product must be installed by professionally qualified per-
sonnel. Incorrect installation can cause damage to people,
animals or property, for which the manufacturer cannot be
held liable.
The product must be connected to the electricity supply via a
•
double pole switch of a suitable size, with contact openings of at
least 3 mm.
• If the electrical supply board (or switching device) is located
some distance from the fan a means of local isolation must be
provided.
To ensure optimum operation, do not block the air intake and
•
exit vents.
• Any ducting used must be free of blockages, and should be insu lated if in an unheated area.
• The room where the product is operating must have adequate
air replacement to ensure maximum effectiveness.
• If the product is sited in a room containing a fuel burning appli ance which is not of the balanced flue type, the installer must en sure that air replacement is adequate both for the fan and the
fuel burning appliance (UNI CIG 7129).
• The product must not be used as an activator for water
heaters, stoves, etc.
• The product must not exhaust into ducts designed to evacuate
fumes from combustion in stoves or other combustion-powered
devices.
RANGE
Trickle Speed 1- 8 lt/sec - 28.8 m³/h
Trickle Speed 2 - 14 lt/sec - 50.4 m³/h
ELX1003 - this fan combines the latest technology with energy
saving and efficiency. It is a quiet running, 3 speed fan. It is designed to run continuously at a pre-selectable choice of 2 trickle
speeds (fixed at installation). The user can boost the fan speed to
its maximum performance when required by means of the cord or
remove the cord and use a remote switch, light switch, PIR sensor
or humidistat. If the fan is to be ceiling mounted, the pull-cord
switch should be put in the “off” position and the cord removed.
A remote switch will be necessary for changing the fan speed.
See wiring diagrams, page 4.
Carol Auster.
The ELX1003 is SAP Appendix Q Listed
ELX1003LV - SELV, 12v version ELX1003.
ELX1003DT - 3 speed, continuous running fan with delay-on timer
and pull cord. The delay-on timer version will run at low speed until
the boost speed is activated by means of the cord or, if the cord is
removed, by means of a remote switch, light switch, PIR sensor or
humidistat. There is a 2 minute delay before the fan starts to run
at its high speed - if the boost speed is deactivated before that
time lapse, the fan will continue to run at low speed. If the boost
speed is activated, the fan will operate at high speed until the
boost switch is turned off. After this, the fan will continue at high
speed for the length of time set on the timer overrun adjustment,
between 0 and 30 mins. (See page 5). After the overrun time has
elapsed, the fan will return to the slower speed.
ELX1003DTLV - SELV, 12v version of ELX1003DT
ELX1003HDT - 3 speed, continuous running fan. The fan runs
continuously at the pre-selected lower speed, and the boost (speed
2) will start to operate automatically when the relative humidity
(adjustable between 40% and 90% +/-5% tolerance) reaches the
pre-set level and will continue to operate at this speed until the humidity has been dispersed and the adjustable over-run timer (adjustable from 0 to 30 minutes) has completed its cycle. The boost
speed can also be activated by as described for model EL1003DT
ELX1003HDTLV - SELV, 12v version of ELX1003HDT

INSTALLATION
1
4
2
5
7
3
6
8
9
1. Check there is nothing missing in box and re-
move front cover.
2. Drill hole in wall - allow extra width if using
ducting - it is the installer's responsibility
to use the appropriate core cutter to obtain the correct hole diameter.
3. Remove circuit board cover.
4. Use fan assembly as template to mark drill
holes.
5. Drill 4 x 6mm dia holes.
6. Fit wall plugs.
12
7/8 Decide whether to have cable access from
rear (recessed) or top (surface) of fan - if
IMPORTANT
If the fan is installed in a ceiling with a vertical duct passing
through an unheated space, a condensation trap MUST be fitted.
Any ducting in an unheated space should also be insulated according to the latest Building Regulations recommendations in the
Domestic Ventilation Compliance Guide.
Failure to do this could result in condensation affecting the operaItion of the fan and cause damage to the ceiling.
10
from top ensure that included grommet is
properly fixed. (See dia 8). If cable is to
come through rear of fan, fit rubber ring (in
cluded) .
9. Screw fan to wall
10. Connect cable using cable clamp - SEE
WIRING DIAs FOR SPECIFIC MODELS
NB this fan is double insulated and does not
need to be earthed
11. Before replacing circuit board cover
choose speed of fan and set delay-on
timer (if applicable)
SEE JUMPER SWITCH SETTINGS BELOW
12. Replace front cover.
If the fan is to be ceiling mounted, the pull-cord switch should be
put in the “off” position and the cord removed. A remote switch
will be necessary for changing the fan speed. See wiring diagrams, page 4.
3
11

JUMPER SWITCH
These fans are designed to run continuously at one of two trickle speeds fixed at installation using the jumper switch. The configurations for the
various models are:
ELX1003
ELX1003HDT N.B to activate delay-on timer remove Jumper 3 ELX1003LV
ELX1003DT N.B to activate delay-on timer remove Jumper 3
ELX1003DTLV N.B to activate delay-on timer remove Jumper 3
WIRING DIAGRAMS
ELXs - 3 Speed with Cord
SELV with Pull Cord Switch
ELX1003LV - 3 Speed with Cord
ELX1003DTLV - 3 Speed with Timer and Cord
ELX1003HDTLV - 3 Speed with Humidistat, Timer and Cord
ELX1003HDTLV N.B to activate delay-on timer remove Jumper 3
ELXs - 3 Speed via remote switch
SELV with External Switch
ELX1003LV - 3 Speed
ELX1003DTLV - 3 Speed with Timer
ELX1003HDTLV - 3 Speed with Humidistat and Timer
SELV Products
All SELV (safety extra low voltage) products must be installed to
conform to IEC 60364.
• Connection between the fan and the mains supply must be by
means of a safety isolating transformer of the appropriate
power rating
• The transformer should be connected to the mains supply via a
double pole safety switch with a contact opening of at least
3mm
• The transformer will operate only one fan
• The transformer must not be installed in Zones 1 or 2, but
should be installed as close as possible to the fan within Zone 3
• The cable used to connect the transformer to the fan must
have a section area of at least 1.5mm
2
and a maximum length
of 10m
• If the fan is a humidity control model, it must be installed using
the transformer supplied for that product.
4

TRIMMER ADJUSTMENT
To adjust the humidistat and timer trimmers, remove the front cover and circuit board cover of
the fan to access the trimmers.
The humidistat (HY) can be adjusted between 40% and 90% relative humidity. Turn clockwise
to decrease sensitivity and set at a higher level of relative humidity.
The timer (T) is adjustable between 0 and 30 minutes. Turn the trimmer clockwise to increase
the overrun time, or anti-clockwise to decrease it.
MAINTENANCE
efore any maintenance
B
or cleaning operation,
switch off the fan and disconnect it from the main
ower supply. The filter
p
can be easily removed and
carefully washed. The
front cover can be cleaned
with a dry cloth or soft
brush. The fan must not
come into contact with
any kind of liquid or solvent.
If this should occur, contact a qualified technician
before reassembling the
fan.
NOTE: The motor does
not require lubrication as
it is maintenance free
"sealed for life" type
DISMANTLING & RECYCLING -
.
and components that can be recy
This product has been designed and constructed using high-quality materials
cled or re-used.