"Elegance” - HIGH PERFORMANCE, LOW CARBON FANS
INSTALLATION and OPERATING INSTRUCTIONS
THIS LEAFLET MUST BE AVAILABLE TO THE USER
The product you have purchased is an extractor fan
for exhausting directly outside or through medium
lengths of ducting and is suitable for wall, ceiling or
window (with optional kit) installation. To ensure optimum operation and guarantee a long life, please read
this manual carefully. It explains how to install correctly, use and maintain the product properly. Following
these instructions will ensure the reliability of the product and extend its working life.
The manufacturer will not be held responsible and
will not accept any responsibility for damage caused
to persons or things due to improper use with reference to the precautions outlined in this leaflet.
The product, constructed using state of the art technology, complies with current standards regarding
electrical equipment. It conforms with the EMC
2014/30/UE European Directive regarding radio
interference suppression and electro-magnetic compatibility.
WARNING: Serious injury or death could result if these
instructions are not carefully followed
• Do not use this product for any purpose other
than that for which it was designed.
• Remove the product from its packaging and make
sure that it has not been damaged. If in doubt,
contact the supplier, authorised dealer, service
centre or manufacturer to check that the product
will still operate correctly. Do not attempt to use
or repair the product before doing this.
• Do not leave packing material within the reach of
children or unskilled people. To dispose of the pack
aging and the appliance at the end of its useful life
refer to the recycling rules in force.
• The use of any electrical product requires compli
ance with some basic rules which are listed below:
- do not touch it with wet or damp parts of the
body (e.g hands, feet).
- this appliance can be used by children aged
8 years and over, and people with reduced
physical, sensory or mental capabilities or lack
of experience and knowledge if they have been
given supervision or instruction concerning use
of the appliance in a safe way and understand
the hazards involved. Children shall not play with
the appliance. Cleaning and user maintenance
should not be carried out by children without
supervision.
• The product should be connected to the mains
electricity supply or electrical outlet only if:
- the electrical voltage and frequency correspond
to those shown on the rating label.
- the capacity of the electricity supply is sufficient
to operate the product at its maximum power.
- suitable electrical protection is provided for the
product to be installed.
• The electrical supply to which the fan is connected
must comply with all existing regulations. All instal lations must comply with current IEE wiring regula
tions.
• Before maintenance or cleaning is carried out, the
product must be switched off and disconnected
from the mains electricity supply.
• If a fault, malfunction or anomaly of any type occurs,
the fan should be isolated (switching it off and dis connecting it from the mains electricity supply) and
advice sought from qualified personnel.
• Always request original spare parts for repairs
• If the product needs to be removed, turn off the
mains supply circuit-breaker and then disconnect
the fan.
• The fan MUST BE installed as detailed in
this leaflet
2
WARNING: Damage could be caused to the product
if the installation instructions are not followed
• The product should not be used in an ambient
temperature higher than 40°C (104°F).
• The product should not be exposed to atmos pheric agents (rain, sun, snow, etc.).
• The product or its parts should not be placed in
water or other liquids.
• Routine maintenance as described below should
be carried out to check the condition of the fan.
• The air or fumes being extracted must be clean
and free from greasy particles, soot, chemical and
corrosive agents, flammable or explosive mixtures.
• The product must be installed by professionally
qualified personnel. Incorrect installation can
cause damage to people, animals or property,
for which the manufacturer cannot be held
liable.
• The product must be connected to the electricity
supply via a double pole switch of a suitable size,
with contact openings of at least 3 mm.
• If the electrical supply board (or switching device)
is located some distance from the fan a means of
local isolation must be provided.
• To ensure optimum operation, do not block the
air intake and exit vents.
• Any ducting used must be free of blockages, and
should be insulated if in an unheated area.
• The room where the product is operating must
have adequate air replacement to ensure max
mum effectiveness.
• If the product is sited in a room containing a
fuel burning appliance which is not of the bal anced flue type, the installer must ensure that
air replacement is adequate both for the fan
and the fuel burning appliance
• The product must not be used as an activator
for water heaters, stoves, etc.
• The product must not exhaust into ducts
designed to evacuate fumes from combustion
in stoves or other combustion-powered devices.
with energy saving and efficiency. It is a quiet running,
3 speed fan. It is designed to run continuously at a
pre-selectable choice of 2 trickle speeds (fixed at
installation). The user can boost the fan speed to its
maximum performance when required by means of
the cord or remove the cord and use a remote
switch, light switch, PIR sensor or humidistat. The
EL1003 is SAP PCDB Eligible.
EL1003DT - 3 speed, continuous running fan with
delay-on timer and pull cord. The delay-on timer version will run at low speed until the boost speed is
activated by means of the cord or, if the cord is
removed, by means of a remote switch, light switch,
PIR sensor or humidistat. There is a 2 minute delay
before the fan starts to run at its high speed - if the
boost speed is deactivated before that time lapse,
the fan will continue to run at low speed. If the boost
speed is activated, the fan will operate at high speed
until the boost switch is turned off. After this, the fan
will continue at high speed for the length of time set
on the timer overrun adjustment, between 0 and 30
mins. (See page 8). After the overrun time has
elapsed, the fan will return to the slower speed.
EL1003HDT - 3 speed, continuous running fan. The
fan runs continuously at the pre-selected lower
speed, and the boost (speed 2) will start to operate
automatically when the relative humidity (adjustable
between 40% and 90% +/-5% tolerance) reaches
the pre-set level and will continue to operate at this
speed until the humidity has been dispersed and the
adjustable over-run timer (adjustable from 0 to 30
minutes) has completed its cycle. The boost speed
can also be activated by as described for model
EL1003DT
3
INSTALLATION
1
23
4
4
5
6
7
8
9
5
10
INSTALLATION
1. check there is nothing missing in box
2.remove front cover
3.drill hole in wall - allow extra width if using
ducting - it is the installer's responsibility to
use the appropriate core cutter to obtain
the correct hole diameter.
4.use fan assembly as template to mark
drill holes
5.drill 4 x 6mm dia holes
6.fit wall plugs
7/8 decide whether to have cable access
from rear (recessed) or top (surface) of fan if from top ensure that included grommet is
properly fixed. (See dia 8). If cable is to come
through rear of fan, fit rubber ring (included)
9. screw fan to wall
10. connect cable using cable clamp - see dia 10.
NB this fan is double insulated and does not
need to be earthed
11. replace front cover
N.B This fan is NOT suitable for use with a
Gravity Grille. It should be installed using either
a Cowl or Fixed Grille.
11
IMPORTANT
If the fan is installed in a ceiling with a vertical duct
passing through an unheated space, a condensation trap MUST be fitted. Any ducting in an
unheated space should also be insulated according
to the latest Building Regulations recommendations in the Domestic Ventilation Compliance
Guide.
Failure to do this could result in condensation
affecting the operation of the fan and cause damage to the ceiling.
Additionally for ceiling installation the pull-cord
switch should be put in the "off" position and the
cord removed. A remote switch will be necessary
for changing the fan speed - see wiring diagrams
on following page.
6
12
13
JUMPER SWITCH
These fans are designed to run continuously at
one of 2 lower speeds fixed at installation
using the jumper switch.
To activate delay-on timer in EL1003DT and
EL1003HDT plug Jumper on position 3 (fig 13)
(N.B Jumpers 1 and 3 will be pre-set at the
factory, depending on the fan model you have)
The user can boost the fan speed to its maximum performance by using cord or remote
switch .
N.B When installing fans via a remote switch,
pullcord switch must be left in "off" position
and the cord removed.
WIRING DIAGRAMS
ELs - 3 Speed with Cord
ELs - 3 Speed via remote switch
7
TRIMMER ADJUSTMENT
To adjust the humidistat and timer trimmers,
remove the front cover of the fan (Fig 2) to
access the trimmers.
The humidistat (HY) can be adjusted
between 40% and 90% relative humidity.
Turn clockwise to decrease sensitivity and
set at a higher level of relative humidity.
The timer (TM) is adjustable between 0 and
30 minutes. Turn the trimmer clockwise to
increase the overrun time, or anti-clockwise
to decrease it.
MAINTENANCE
Before any maintenance or
cleaning operation, switch off
the fan and disconnect it from
the main power supply. The
front cover can be cleaned
with a dry cloth or soft brush
The fan must not come into
contact with any kind of liquid
or solvent. If this should occur,
contact a qualified technician
before reassembling the fan.
NOTE: The motor does not
require lubrication as it is
maintenance free "sealed for
life" type.
DISMANTLING & RECYCLING