“A” - AXIAL FANS
Installation Instructions
• for toilets, bathrooms, utility rooms and kitchens
• suitable for installation in - wall
- window
- ceiling
• different models - standard
- pull cord
- timer
- automatic shutter
- humidity control
- two speed
- PIR (Passive Infra Red) sensor
- Low Voltage (SELV) supply
“A” - AXIAL FANS
Installation Instructions
PLEASE READ THE FOLLOWING INSTRUCTIONS VERY CAREFULLY BEFORE INSTALLING THE PRODUCT.
THE RANGE
A10/4, A12/5, A10/4A, A12/5A, A15/6, A10/4LV, A10/4ALV - standard versions should be operated by a remote switch.
A10/4C, A12/5C, A15/6C, A10/4CA, A12/5CA, A15/6CA, A10/4CLV- pull cord operated
A10/4T, A12/5T, A10/4AT, A12/5AT, A15/6T, A10/4TLV, A10/4ATLV - with adjustable overrun timer – these fans should be operated
by a remote switch which can also be used to control the room light. After the light/fan is switched off the fan will continue to run for the
pre-set length of time .
A10/4HCT, A12/5HCT, A10/4HCTA, A12/5HCTA, A10/4HCTLV, A10/4HCTALV - with humidistat and timer - the adjustable, electronic
humidistat is pre-set so that the fan will operate automatically when the moisture content in the room reaches 70% R.H. The fan will
continue to operate until the Relative Humidity falls below the pre-set level and the timer has completed the over-run period. The fan can
be operated by the pull cord (or by a remote switch) independently of the humidistat (a neon light indicates that the fan is ope rat ing in this
mode). NOTE: the fan will continue to operate for a short period after the cord is pulled a second time, ie until the humidistat senses that
the relative humidity in the room has fallen beneath the pre-set level and the timer has completed its overrun period.
A15/6CA2, A15/62R, A15/6H2C - 2 speed models. A15/6CA2 – pulling the co rd once on this fan will make it operate at its ma ximum
speed; pulling the cord again will reduce the speed to its lower level; pulling the cord again will turn the fan off. A15/62R - this fa n is
designed for continuous running at its low speed; using the remote switch will boost the fan to its maximum speed (and back to its lower
speed). A15/6H2C comes on automatically at its lower speed when the moisture content in the room reaches its pre-set level. Pulling
the cord will boost the speed of the fan to its maximum level (a neon light indicates that the fan is operating in this mode). Pulling the
cord again will revert the fan to its lower speed and automatic operation by the humidistat and timer.
A10/4TPIR, A10/4HTPIR, A10/4PIRLV - with Passive Infra Red sensor. These fans operate automatically when a person is in the room
(at 8m and 60°). They will continue to operate for a pre-set length of time after the room has been vacated. The A10/4HTPIR wi ll also
operate automatically via the humidistat regardless of whether or not the room is occupied.
All versions with “A” have delay action, slow moving shutters.
All versions with “LV” are LOW VOLTAGE (SELV). They MUST be installed using the transformer provided.

All versions with Timer or Humidistat incorporate adjustable trimmers. The overrun period on timer can be adjusted upwards by turning
the RED trimmer on the PC Board in a clockwise direction (from a minimum of 3 min to a maximum of 15 min). The Humidistat can be
adjusted so that it starts to operate at a higher level or relative humidity by turning the BLUE trimmer in a clockwise direction (from a
minimu m of 40% to a max i mu m of 100%).
All versions with Humidistat incorporate a controlled temperature set-back allowing the humidistat to take into account variations in the
ambient temperature and to avoid the fan switching on unnecessarily. This reduces fan operation at night.
All the fans (w ith the exception of th e “LV ” mo dels) are splashproof to standard IPX4. The “LV” fans are rated IP57 enabling them to be
safely installed in areas where a splashproof fan does not provide sufficient protection against water ingress.
All fans are ex t re me ly quiet in oper ati on.
IMPORTANT - SITING INFORMATION
1. The fans are suitable for installation into:
a. WALLS - with screws or with Wall Venting Kit (optional)
b. CEILING - with screws or with Ceiling Ring (optional)
c. WINDOWS - with optional Window Kit for single glazed windows up to 20 mm thick
or with optional Double Glazing Kit
2. The fans are constructed to BS5490:1977 (IEC529:1976) - Ingress Protection Standard - Classification IPX4. This makes these fans
suitabl e for us e in b athrooms an d ar e as con taining sh ow ers .
3. The fan should be installed at a minimum height of 2.3 m.
4. The fan must not be exhausted into a duct which is already used for any other purpose.
5. The fan must not be used in an ambient temperature higher than 40° C.
6. If the fan is to be sited in a room containing a fuel burning appliance, the installer must ensure that air replacement is adequate both
for the fan and the fuel burning appliance.
7. Installation must be carried out by qualified personnel. Incorrect installation can cause damage to people, animals or property, for
which the ma nufact urer cannot be he ld liab le .
8. If you have any doubts concerning the use of this product, please contact your supplier.
IMPORTANT - ELECTRICAL INFORMATION
1 All electrical connections must comply with current BS7671 wiring regulations.
2 The fan is a fixed appliance, and the electrical supply must therefore be by a fixed wired and fused (3 amp) spur incorporating a double
pole switch with contact openings of at least 3 mm. Use twin conductor cable of at least 1 mm in sec ti on.
3 Your fan is double insulated and does not require earthing.
4 The fans comply with BSEN60335; with the Low Voltage Directive; with EC Directive EMC 89/336 for the Suppression of Radio
Interference.
5 It is recommended that the installation be carried out by a qualified electrician.
6 The printed circui t bo ard in these fa ns has bee n protect ed to m ak e it co mp atible wit h t he m aj orit y of fl uorescent fittings av a ila bl e on the
market today. However, it is impossible to be aware of all the new products introduced. We suggest therefore that you contact your
supplier to establish the compatibility of the fluorescent fitting you intend to use.
INSTALLATION INSTRUCTIONS
Preparation
1. Remove all packing material and check that the fan has not been damaged in transit.
2. Check that your electrical voltage and frequency correspond with those marked on the rating label.
3. Check the location of existing wiring for ease of connection.
4. Cut a 4"/10 cm, 5”/12cm, 6”/15mm hole (plus thickness of ducting to be used, when necessary) in the wall, ceiling or window.
5. Make the electrical connections as in the following instructions.
Fixing Instru ctio ns
1. Loosen the single screw located in the lower edge of the casing, and remove the front cover by pulling forward and upward.
2. How to install in a wall - using the body of the fan as a template, mark 4 holes in the wall, drill and fit wall plugs. Fix the main body of
the fan to the wall using 4 screws locating them through the holes at each corner. Ensure that the fixing surface is flat in order to
avoid distortion of the casing when the fixing screws are tightened. If using Wall Vent Kit, secure flexi-duct to spigot of fan an d spigot
of grille. Fix grille to outside wall through 4 holes located in corners.
3. How to install in a ceiling - if installing fan into plasterboard ceiling put spigot of fan through hole and secure using Ceiling Ring. If
the ceiling is of thicker construction follow wall installation instructions above.
4. How to install in a window - separate the locking ring by unclipping it from the grille section of the Window Kit. Put fan through hole
already cut in window and screw the locking ring on to fan spigot securing it firmly. Clip back on the central flange/outer grille to the locking
ring ensuring it lines up with the inside part of the fan. N.B.: By following the above instructions, the fan can be installed with the Double Glazing
Window Kit after the hole ha s been cu t and sealed b y the manuf acturer .
5. Connect the incoming wiring supply as indicated in "Wiring Instructions" below.
6. Replace the front cover by first locating the top edge of the cover over the top edge of the main body and then hinge the cover downwards.
7. Lock the cover in place by tightening the screw on the lower edge.
WIRING INSTRUCTIONS
1. Ensure that the mains electrical supply is switched off during the installation of the fixed wirin g sp u r.
2. Read carefully "Important-Electrical Information" above.
3. Connect as shown in the Wiring Diagrams below.
FIG 1: A 10/4, A 12/5, A 10/4 A, A 12/5 A, A 15/6