Vecima Networks EUM3006 User Manual

EUM3006 Integrated
Outdoor Modem
Installation Guide
APCD-LM048-1.1

Copyright

Release 1.1, Dec. 2004
The following are trademarks or registered trademarks of their respective companies or organi­zations:
Windows XP/Microsoft
Windows 2000/Microsoft
:
APCD-LM048-1.1 ii

Software License Agreement

This is a legal agreement between you (either an individual or an entity) and WaveRider Communica­tions Inc. for the use of WaveRider computer software, hereinafter the “LICENSED SOFTWARE”.
By using the LICENSED SOFTWARE installed in this product, you acknowledge that you have read this license agreement, understand it, and agree to be bound by its terms. You further agree that it is the full and complete agreement between you and WaveRider Communications Inc., superseding all prior written or verbal agreements of any kind related to the LICENSED SOFTWARE. If you do not understand or do not agree to the terms of this agreement, you will cease using the LICENSED SOFTWARE immediately.
1. GRANT OF LICENSE—This License Agreement permits you to use one copy of the LICENSED SOFTWARE.
2. COPYRIGHT—The LICENSED SOFTWARE is owned by WaveRider Communications Inc. and is protected by copyright laws and international treaty provisions; therefore, you must treat the LICENSED SOFTWARE like any other copyrighted material (e.g., a book or magazine).
3. LIMITS OF FEATURE AVAILABILITY—The LICENSED SOFTWARE is sold with limitations as
to certain feature availability and use. These limits are governed by the terms of the purchase agreement. Any actions resulting in the exceeding of these limits is not permitted, and can result in unpredictable performance.
4. OTHER RESTRICTIONS—You may not rent or lease the LICENSED SOFTWARE. You may not reverse engineer, decompile, or disassemble the LICENSED SOFTWARE.
5. LIMITED WARRANTY—The LICENSED SOFTWARE is provided “as is” without any warranty of any kind, either expressed or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. The entire risk as to the quality and performance of the LICENSED SOFTWARE is with you, the licensee. If the LICENSED SOFTWARE is defective, you assume the risk and liability for the entire cost of all necessary repair, service, or correction.
Some states/jurisdictions do not allow the exclusion of implied warranties, so the above exclusion may not apply to you. This warranty gives you specific legal rights, and you may have other rights, which vary from state/jurisdiction to state/ jurisdiction.
WaveRider Communications Inc. does not warrant that the functions contained in the LICENSED SOFTWARE will meet your requirements, or that the operation of the LICENSED SOFTWARE will be error-free or uninterrupted.
6. NO OTHER WARRANTIES—To the maximum extent permitted by applicable law, WaveRider Communications Inc. disclaims all other warranties, either express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose, with regard to the LICENSED SOFTWARE and the accompanying written materials.
7. NO LIABILITY FOR CONSEQUENTIAL DAMAGES—To the maximum extent permitted by applicable law, in no event shall WaveRider Communications Inc. or its suppliers be liable for any damages whatsoever (including, without limitation, damages for loss of business profits, business interruption, loss of business information, or any other pecuniary loss) arising from the use of or inability to use the LICENSED SOFTWARE, even if WaveRider Communications Inc. has been advised of the possibility of such damages, or for any claim by any other party.
Because some states/jurisdictions do not allow the exclusion or limitation of liability for consequential or incidental damages, the above limitation may not apply to you. In no event will WaveRider’s liability exceed the amount paid for the LICENSED SOFTWARE.
iii APCD-LM048-1.1

Warranty

In the following warranty text, “WaveRider®” shall mean WaveRider Communications Inc.
This WaveRider product is warranted against defects in material and workmanship for a period of one (1) year from the date of purchase. During this warranty period WaveRider will, at its option, either repair or replace products that prove to be defective.
For warranty service or repair, the product must be returned to a service facility designated by WaveRider. Authorization to return products must be obtained prior to shipment. The WaveR­ider RMA number must be on the shipping documentation so that the service facility will accept the product. The buyer shall pay all shipping charges to WaveRider and WaveRider shall pay shipping charges to return the product to the buyer within Canada or the USA. For all other countries, the buyer shall pay shipping charges as well as duties and taxes incurred in shipping products to or from WaveRider.
WaveRider warrants that the firmware designed by it for use with the unit will execute its pro­gramming instructions when properly installed on the unit. WaveRider does not warrant that the operation of the unit or firmware will be uninterrupted or error-free.
Limitation of Warranty
The foregoing warranty shall not apply to defects resulting from improper or inadequate mainte­nance by the buyer, buyer-supplied interfacing, unauthorized modification or misuse, operation outside the environmental specifications for the product, or improper site preparation or mainte­nance. No other warranty is expressed or implied. WaveRider specifically disclaims the implied warranties of merchantability and fitness for any particular purpose.
:
No Liability for Consequential Damages
To the maximum extent permitted by applicable law, in no event shall WaveRider or its suppliers be liable for any damages whatsoever (including, without limitation, damages for loss of busi­ness profits, business interruption, loss of business information, or any other pecuniary loss) arising from the use of or inability to use the product, even if WaveRider has been advised of the possibility of such damages, or for any claim by any other party.
Because some states/jurisdictions do not allow the exclusion or limitation of liability for conse­quential or incidental damages, the above limitation may not apply to you.
In no event will WaveRider’s liability exceed the amount paid for the product.
Regulatory Notices
This equipment has been tested and found to comply with the limits for a Class B Intentional Radiator, pursuant to Part 15 of the FCC Regulations. These limits are intended to provide pro­tection against harmful interference when the equipment is operated in a residential environ­ment.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.
Notice to User
Any changes or modifications to equipment that are not expressly approved by WaveRider may void the user’s authority to operate the equipment.
APCD-LM048-1.1 iv
v APCD-LM048-1.1

Contents

Figures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .viii
Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . x
Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xii
1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1.1 Document Scope . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1.2 EUM3006 Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
1.3 EUM3006 - End-user Modem or Customer Premises Equipment . . . . . . . . . . . . . . . . 5
1.3.1 Key Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.3.2 EUM3006 Integrated, High Gain, Active Diversity Antenna . . . . . . . . . . . . . . . 5
1.3.3 Ethernet Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1.3.4 Power over Ethernet (PoE) Injector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1.3.5 PoE Lightning Arrestor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
1.4 Installation Aids. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
:
2 MDB1000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2.1 Placing the MDB1000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2.2 Powering the MDB1000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2.3 Turning the MDB1000 On . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
2.4 Turning the MDB1000 Off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
2.5 Interpreting the LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
3 Setup Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
3.1 Accessing the Setup Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
3.2 Setup Menu. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
3.3 Radio Link Status Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
3.4 Troubleshooting Information Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
4 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
4.1 Installation Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
4.2 Pre-Installation Steps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
4.2.1 Network and EUM3006 Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
4.2.2 Installer’s Kit and Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
4.2.3 Verifying the EUM3006 Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
4.2.4 End-Users PC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
4.3 Installation Steps. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
4.3.1 Locating the EUM3006 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
4.3.2 Mounting the EUM3006 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
4.3.3 Running Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
4.3.4 Provide Power to the EUM3006 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
4.3.5 Connecting the End-User’s PC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
4.3.6 Testing the Data Link . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
4.4 Post-Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
APCD-LM048-1.1 vi
Appendix A Factory Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Appendix B Ethernet Cables and Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Appendix C Acronyms and Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
vii APCD-LM048-1.1

Figures

Figure 1 Grounding EUM3006 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .xvii
Figure 1 EUM3006 Integrated Outdoor Modem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Figure 2 EUM3006 Longitudinal and Transverse Axes . . . . . . . . . . . . . . . . . . . . . . . . 6
Figure 3 PoE Injector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Figure 4 MDB1000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Figure 5 EUM3006 Mounting - Vertical Orientation . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Figure 6 EUM3006 Mounting - Horizontal Orientation . . . . . . . . . . . . . . . . . . . . . . . 29
Figure 7 PoE Injector - Data & PWR and Data Ports . . . . . . . . . . . . . . . . . . . . . . . . 30
Figure 8 T568A Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Figure 9 T568B Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
:
APCD-LM048-1.1 viii
ix APCD-LM048-1.1

Tables

Table 1 MDB1000 Signal Strength FOMs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Table 2 MDB1000 Signal Quality LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Table 3 Pre-Installation Stage Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Table 4 Installation Stage Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Table 5 Ethernet Interface Card LED Status Displays . . . . . . . . . . . . . . . . . . . . . . . 31
Table 6 Ethernet Interface Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Table 7 Wiring T568A and T568B ends for Ethernet Cables . . . . . . . . . . . . . . . . . . 40
Table 8 Acronyms and Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
:
APCD-LM048-1.1 x
xi APCD-LM048-1.1

Preface

Conventions

The following conventions are used throughout this document:
:
WARNING!
Whenever you see this icon and heading, the associated text addresses or discusses a critical safety or regulatory issue.
CAUTION: Whenever you see this icon and heading, the
associated text discusses an issue, which, if not followed, could result in damage to, or improper use of, the equipment or software.
TIP: Whenever you see this icon and heading, the associated text provides a tip for facilitating the installation, testing, or operation of the equipment or software.

Regulatory Notices

This device has been designed to operate with only its integrated antenna. This device has been tested using unshielded Ethernet CAT-5E cable.

Federal Communications Commission

The EUM3006 has been designed and manufactured to comply with FCC Part 15.
Operators must be familiar with the requirements of the FCC Part 15 Regulations prior to operating any link using this equipment. For installations outside the United States, contact local authorities for applicable regulations.
The FCC ID for the EUM3006 equipment is OOX-EUM3006.
The transmitter of this device complies with Part 15.247 of the FCC Rules.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not
APCD-LM048-1.1 xii
installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
--Reorient or relocate the receiving antenna.
--Increase the separation between the equipment and receiver.
--Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
--Consult the dealer or an experienced radio/TV technician for help.
Interference Environment
Operation is subject to the following conditions:
This device may not cause harmful interference and,
This device must accept any interference received, including interference that might cause undesired operation.

Operational Requirements

In accordance with the FCC Part 15 regulations:
1. The maximum average power output of the intentional radiator shall not exceed one (1) watt (30 dBm) for all spread spectrum systems operating in the 902 to 928MHz band.
2. Stations operating in the 902 to 928MHz band may use transmitting antennas of directional gain greater than 6dBi, provided the average output power from the intentional radiator is reduced by the amount in dB that the directional gain of the antenna exceeds 6dBi.
3. The operator of a spread spectrum system and the user of the radio device are each responsible for ensuring that the system is operated in the manner outlined in Interference Environment on page xiii.
The EUM3006 with its integrated antenna complies with these requirements, since the maximum average transmitting power is 25.8 dBm measured at the internal antenna port which is not accessible to the user. This is 4.2 dB below the maximum allowed, so the integrated, high-gain, active diversity antenna is allowed to provide an additional 4.2 dB gain for a total of 10.2 dBi gain.

Warnings and Advisories

General Advisory
Installers, operators and maintenance personnel must be familiar with the related safety requirements before they attempt to install or operate the EUM3006.
xiii APCD-LM048-1.1
It is the responsibility of the operator to ensure that the public is not exposed to excessive Radio Frequency (RF) levels. The applicable regulations can be obtained from local authorities.
WARNING!
The EUM3006 Integrated Outdoor Modem must be properly grounded. WaveRider assumes no liability for failure to adhere to this recommendation or to recognized general safety precautions.
WARNING!
To comply with FCC RF exposure limits, the EUM3006 must be fix-mounted outdoors to provide a separation distance of 30cm (1 foot) or more from all persons to satisfy RF exposure requirements. The distance is measured from the nearest point of the modem to the human body. It is recommended that the modem be installed in a location with minimal
pathway disruption by nearby personnel.
:

Important Safeguards

CAUTION: To reduce risk of electrical shock, do not remove covers, since there are no user-serviceable parts inside. Refer servicing to qualified personnel.
1. Read all these instructions before installing and operating the EUM3006.
2. Retain these instructions for future reference.
3. Heed all warnings on the EUM3006 and in these instructions.
4. Follow all instructions.
5. Do not use EUM3006 and PoE Injector near water.
6. Unplug EUM3006 and PoE Injector from the wall outlet before cleaning. Clean only with a damp cloth.
7. Use only attachments recommended by WaveRider.
8. The fins and metal casing protect the EUM3006 from overheating to ensure reliable operations. Do not cover the EUM3006 and PoE Injector. Do not place the EUM3006 or PoE Injector near or over a radiator, stove, heat register or other source of heat. Do not place the EUM3006 and PoE Injector in a built-in installation such as a bookcase or rack unless proper ventilation is provided. The EUM3006 has an outdoor temperature rating, so it can handle a much larger range of temperatures than the
WARNING!
APCD-LM048-1.1 xiv
PoE injector. However, it is still possible to exceed the EUM3006 specifications by improper placement or ventilation.
9. Operate the EUM3006 only from a 48 VDC PoE Mode B power source.
10. Operate the PoE Injector only from a 100 - 250 VAC, single phase, 47-63 Hz AC power source. The PoE Injector is rated for indoor use only.
11. The PoE Injector is equipped with a 3-wire grounding-type plug, which will only fit into a grounding-type power outlet. This is a safety feature. If you are unable to insert the plug into the outlet, contact an electrician to replace your obsolete outlet. Do not defeat the purpose of the grounding-type plug.
12. Route the AC Power-supply cord and Ethernet cables so that they are not likely to be walked on or pinched by items placed upon or against them, paying particular attention to cord and cables at their plugs, convenience receptacles and the points where the cords exit the equipment.
13. Provide strain relief for cables near their connections. This is typically done by leaving a loop in the cable near the connection.
14. Ensure the system is properly grounded to provide some protection against voltage surges and built-up static charges.
15. Do not locate the EUM3006 in the vicinity of overhead power lines or other electric light or power circuits, or where it can fall onto such power lines or circuits. When installing outdoors, take extreme care to keep from touching such power lines or circuits, as contact with them might be fatal.
16. For added protection during a lightning storm, or when it is left unattended and unused for long periods of time, unplug the Ethernet cable from the PoE injector to the EUM3006 and unplug the PoE Injector from the wall outlet. If the Ethernet cable to the EUM3006 goes through a PoE Lightning Arrestor, then disconnect the inside Ethernet cable. This will power down the EUM3006.
17. Do not overload wall outlets and extension cords as this increases the risk of fire or electric shock.
18. Never push objects of any kind through openings in this wireless product as they may touch dangerous voltage points or short-out parts that could result in a fire or electric shock. Never spill liquid of any kind on the PoE Injector. The EUM3006 is an outdoor unit, but it is not submersible nor is it immune to all liquids.
19. Do not attempt to service this wireless product yourself, as opening or removing covers may expose you to dangerous voltage or other hazards. Refer all servicing to qualified service personnel.
20. Unplug PoE Injector from the wall outlet and refer servicing to qualified service personnel under the following conditions:
When the power supply cord or plug is damaged.
If liquid has been spilled or objects have fallen into these products.
If the PoE Injector has been exposed to rain or water.
If the EUM3006 does not operate normally for an extended period of time when
following the operating instructions. Note that it is possible that Internet traffic can
xv APCD-LM048-1.1
be slow even under normal operations due to network congestion and radio interference and fading and not as result of problems with the EUM3006.
When the EUM3006 or PoE Injector exhibit distinct changes in performance. This may indicate a need for service.
21. When replacement parts are required, be sure the service technician has used replacement parts specified by the WaveRider or with the same characteristics as the original part. Improper substitutions may result in fire, electric shock or other hazards.
22. Upon completion of any service or repairs to this wireless product, ask the service technician to perform safety checks to determine that the wireless product is in proper operating condition.
23. Follow WaveRider recommendations when mounting the EUM3006 on a wall, roof, or tower.
24. Install the EUM3006 in compliance with local and national electrical codes. The following are the national codes. The installer is responsible for knowing the appropriate local codes.
In the United States, use the National Electrical Code (NEC);
In Canada, use the Canadian Electrical Code, Part 1, CSA C22.1;
In other countries, use International Electrotechnical Commission (IEC) 364, part 1 through 7.
:
25. Ensure that the EUM3006 is properly grounded by attaching a grounding cable to the bolt marked “GND” on the back of the EUM3006. Art. 820-40 of the NEC (US) provides guidelines for proper grounding and, in particular, specifies that the grounding cable(s) shall be connected to the grounding system of the building, as close to the point of cable entry as possible.
APCD-LM048-1.1 xvi
Connect Ground Wire to GND Lug
Ethernet Cable
Grounding Conductor
(NEC Sec. 810-21)
Electrical Service Equipment
Ethernet Surge Protection

Customer Support

Telephone: +1 416–502–3161
Fax: +1 416–502–2968
Email: Customer Services Group:
techsupport@waverider.com
Customer Documentation Feedback and Comments:
customerdocs@waverider.com
URL: www.waverider.com
WaveRider offers a complete training program. Please contact your sales representative for training information.
Power Service Grounding Electrode System (NEC Art. 250, Part H)
Figure 1 Grounding EUM3006
xvii APCD-LM048-1.1

1 Introduction

The LMS4000 900 MHz Radio Network provides wireless high-speed Internet connectivity to business, SOHO (small office, home office) and residential customers. LMS4000 operates in a point-to-multipoint configuration, with one base station efficiently serving many subscriber stations. LMS4000 transmission is based on a high-performance MAC protocol, and industry standard IP routing and Ethernet switching technology. No radio license is required, since LMS4000 operates in the 900 MHz ISM band. LMS4000 can deliver Internet service over long ranges and often where the radio paths between the base station and subscribers are partially or even total obscured, that is, non-line-of-sight. Connection between the end-user’s computer and the subscriber station is through an Ethernet port.
The EUM3006 Integrated Outdoor Modem is the latest modem for the LMS4000 system and offers significant improvements: outdoor unit with extended temperature range; integrated, high-gain, active diversity antenna; 802.3af compatible, 48 VDC Power over Ethernet; higher output power; improved Rx Sensitivity; DHCP Client; Auto CCU Discovery, Automatic Remote Configuration; easy-to-use Setup menu and MDB1000 alignment tools; VoIP support.

1.1 Document Scope

This Installation Guide covers only the EUM3006 Integrated Outdoor Modem. It provides information on the installation of the EUM3006, its performance, and any required regulatory information, including approved installation notices.
Related information can be found in the suite of available LMS4000 manuals, which includes the following:
LMS4000 900 MHz Radio Networking Concepts (APCD-LM053)
LMS4000 Data Networking Concepts (APCD-LM050)
LMS4000 Managing the Network (APCD-LM052)
LMS4000 CLI Reference Manual (APCD-LM051)
LMS4000 SNMP Reference Manual (APCD-LM049)
APCD-LM048-1.1 1
1: Introduction
These manuals provide information not included in this Installation Guide, including information on:
These manuals, as well as manuals for hardware elements, including EUMs and CCUs, can be found on WaveRider’s Web site (http://www.waverider.com).
Other documents on the WaveRider web site are useful to assist in installing and operating the EUM3006. For example, you can find information on which roof and wall mounting brackets are recommended.
WaveRider recommends that you be familiar with the following sections before proceeding with the instructions in this guide:
Planning, installing and managing the network.
Diagnostic tools for the network and EUM.
Details on the Command Line Interface and methods of accessing the EUM.
Manual configuration of the EUM via the CLI.
Glossary of network terms.
Software License Agreement on page iii
Warranty on page iv
Conventions on page xii
Warnings and Advisories on page xiii
Important Safeguards on page xiv
NOTE: The information contained in this manual is subject to change
without notice. The reader should consult the WaveRider web site for updates.

1.2 EUM3006 Features

The EUM3006 is a major step in the evolution of the LMS4000 900MHz Wireless Internet Modems offered by WaveRider. It is a Power-over-Ethernet, outdoor unit with integrated, high­gain, active diversity antenna.
The EUM3006 complements the existing LMS4000 Products:
The CCU3000 and the NCL1900 are the current base station products;
The EUM3004 with its diversity antenna is the current indoor end-user modem, providing easy installation for areas with signal levels that allow for indoor installations;
The EUM3006 with its integrated antenna completes the product line, providing an outdoor unit for areas where the indoor unit is not usable, due to operational or RF link considerations.
2 APCD-LM048-1.1
1: Introduction
Figure 1 EUM3006 Integrated Outdoor Modem
The EUM3006 has new features that provide improved RF performance as well as ease of installation. The RF performance is enhanced due to the integrated, high-gain, active diversity antenna, improved transmit power, and improved receive sensitivity.
Hardware and software improvements make outdoor installation easier than ever, allowing rapid deployment, single person installation, and even end-user self-installation. These improvements include Power-over-Ethernet, mounting and alignment tools, and Automatic Remote Configuration of all parameters using DHCP and RADIUS. The Automatic Remote Configuration of parameters also allows the network operator to easily manage and reconfigure the EUM3006 after it is installed, including changing frequency, passwords, and SNMP parameters.
Key features of the EUM3006 include:
Easy Outdoor Installation - The EUM3006 is tested to meet ETSI 300-019
environmental standards for outdoor installations, with an extended temperature range of -40º C to 50º C plus solar loading. The EUM3006 can also work in uninhabited indoor locations, such as attics, if there is an adequate RF signal. The advantages of an integrated outdoor unit include:
More flexible installations.
Improved range since there are no RF losses from long cable runs.
Lower installation costs.
APCD-LM048-1.1 3