Vcom IduBST1918 Installation And Operation Manual

INSTALLATION AND OPERATION GUIDE FOR SYSTEM OPERATORS
Proprietary to VCom Inc.
All rights reserved.
No part of this publication may by reproduced in any form or by any means or used to make any derivative work (such as translation,
transformation or adaptation) without written permission from VCom Inc.
VCom Inc. reserves the right to revise this publication and to make changes in content from time to time without obligation on the part of
VCom Inc. to provide notification of such revision or change.
VCom Inc. provides this guide without warranty of any kind, either implied or expressed, including, but not limited to, the implied
warranties of merchantability and fitness for a particular purpose. VCom Inc. may make improvements or changes in the product(s) described in this manual at any time.
BST1918 Manual; ml_bst1918 _02 Rev02 (Sept 05); Approved: C.H.
Specifications subject to change without notice — Printed in Canada
VCom Inc.
Approved: C.H.
ii
Thank-you for purchasing this product
and welcome to VCom!
You have chosen an innovative solution from a leading technology design center in the ongoing TV & data delivery revolution.
No doubt you’ve been thinking that the future of your television delivery system includes new technologies such as Digital TV, Internet Over Cable, Wireless Cable. By selecting VCom, you are benefiting from the same design powerhouse that since 1988 has created custom RF and digital products for technology leaders such as AT&T, Cisco Systems, Cogeco, Comcast, and Cox Communications.
VCom designs and manufactures:
 Agile CATV Modulators  256 QAM Upconverters  Digital Video Modulators  Frequency Translators  Spread Spectrum Devices  MMDS Transceivers  Off Air/CATV Demodulators  Wireless Cable MMDS  Wireless Cable LMDS  Video On Demand Products
and more! Designs to fill the market needs of the CATV industry – both foreign and domestic.
For additional product or corporate information, contact us:
On the web at: www.vcom.com By sending email to: sales@vcom.com By telephone: (306) 955-7075 By fax: (306) 955-9919 By snail mail: VCom Inc.
150 Cardinal Place Saskatoon, SK Canada S7L 6H7
VCom's Corporate Mandate
is to be a leading worldwide designer and manufacturer of
state-of-the-art communications equipment and components. Through
the remarkable success of our customers and business partners,
VCom innovations are achieving this goal.
VCom Inc.
Approved: C.H.
iii
SAFETY PRECAUTIONS
1. Before installing and operating this equipment, read all Safety, Installation and Operating sections. Retain this manual for future reference.
2. Follow all instructions — Failure to do so may result in damage to the unit or severe personal injury.
3. Servicing should not be attempted by the user. There are no user serviceable parts inside. Refer all servicing to factory-qualified personnel.
4. Shock Hazard — An electrical shock hazard exists when the chassis cover is removed as is required to set internal controls. Always disconnect power from the unit before removing the cover.
5. Cleaning — Do not use liquid or aerosol cleaners. Use a damp cloth for cleaning.
Warning Do not work on the system or connect or disconnect cables during periods of lightning activity.
PRÉCAUTIONS DE SÉCURITÉ
1. Avant d'installer ou d'opérer cet équipement, lisez, toutes les sections de sécurités, d'installations et d'opérations. Gardez ce manuel comme source de référence.
2. Suivez toutes instructions - si non, vous risquez d'endommager la machine ou de vous blesser sérieusement.
3. N'essayez, pas de réparer cet équipement vous même. Référez toutes revisions nécessaire au personnel qualifié de la manufacture.
4. Risque de choc - Il y a un risque de décharge électrique qui existe quand la couverture du châssis est enlevée, comme est nécessaire pour ajuster les contrôlcs internes. Il faut toujours couper l'électricité avant d'enlever le couvercle pour faire aucun ajustage.
5. Le nettoyage - n'utilisez pas de nettoyeurs aérosols ou liquides. Utilisez un tissu humide pour nettoyer.
Attention Ne pas travailler sur le système ni brancher ou débrancher les câbles pendant un orage du
foudre.
Important Installation Instructions
Caution: To comply with FCC RF exposure requirements in section 1.1307, any antenna which is connected to a BST1918 requires a minimum distance of 1.5 meters between it and all persons.
VCom Inc.
Approved: C.H.
iv
INDEX
1.0 GENERAL INFORMATION ...................................................................................................... 6
1.1 System Overview.................................................................................................................................... 6
1.2 BST1918 Features.................................................................................................................................. 6
1.3 Specifications..........................................................................................................................................7
2.0 INSTALLATION.......................................................................................................................... 8
2.1 Unpacking the Unit.................................................................................................................................. 8
2.2 Operating Environment............................................................................................................................ 8
2.3 Power Requirements ................................................................................................................................ 8
2.4 Rack Mounting ........................................................................................................................................8
2.5 Module Installation/Replacement ............................................................................................................ 8
3.0 OPERATION................................................................................................................................ 9
3.1 Front Panel Description ...........................................................................................................................9
3.2 Operating Modes.................................................................................................................................... 10
4.0 REAR PANEL CONNECTIONS .............................................................................................. 11
5.0 WARRANTY AND SERVICE POLICIES................................................................................ 12
5.1 Warranty Statement ...............................................................................................................................12
5.2 Service Policies: How to Return an Item for Service: ...........................................................................12
5.3 Repair Charges and Warranty Exemptions............................................................................................ 13
VCom Inc.
Approved: C.H.
v
1.0 GENERAL INFORMATION
1.1 System Overview
The BST1918 combines low noise high power transceiver(s) and sophisticated management capability to offer a radio solution for 1.9 GHz BWIN single cable connection with the VCom BST1918 allows for full SNMP management (via the WM4040) of the operational parameters. Built-in power detectors allow for easy input and output level configuration.
1.2 BST1918 Features
High output power: +31 dBm carrier level with 64QAM
Automatic transmit power control automatically corrects for cable loss and input level changes
RF output mutes when changing output configuration or in a switchover situation
Low noise: <4 dB including duplexer loss
Digital temperature compensation to guarantee specifications over full operating temperature range
All local oscillators are frequency synthesized and locked to a common high stability reference from the WM4040
FLASH memory for easy software updates
Externally connected antennas (60°, 90°, 120°, Omni)
High reliability, state-of-the-art design using microstrip, MMIC and surface mount technology
Conservative component derating and 100% burn in help ensure reliable operation
Full SNMP management when combined with the WM4040:
Monitors Controls Alarms
Transmit IF Level RF Output Power Setting Phase Lock Lost
Transmit RF Level RF Output Power Mode (closed-loop power control,
Receive IF Level RF Output Mute Loss of Transmit IF
Internal Temperature Receive Gain Transmit RF Level
Module Serial Numbers
Transmit Phase Lock
Receive Phase Lock
TM
BASED ON DOCSIS
open loop gain control)
TM
base stations. Out-of-band signaling over the
Overheating
VCom Inc.
Approved: C.H.
6
1.3 Specifications
BST1918 BASE STATION TRANSCEIVER SPECIFICATIONS
TRANSMIT
IF Input Frequency 555.0 -570.0MHz (2MHz channels)
555.2 - 569.8MHz (6MHz channels)
Bandwidth Channel size: typical 6MHz, adjustable through WM404x IF Input Level +10 dBm nominal (total power) IF Detector Accuracy ±1.0 dB typical RF Output Frequency Range Block B: 1950.0 – 1965.0MHz, (2MHz channels)
1950.2 – 1964.8MHz, (6MHz channels) Block C: 1975.0 – 1990.0MHz, (2MHz channels)
1975.2 – 1989.8MHz, (6MHz channels)
Frequency Response (any 6 MHz band) 1.0 dB peak-peak Rated Output Power at Antenna Port +31 dBm (QPSK, 16QAM, 64QAM) Output Power Stability ±1.0 dB over frequency and temperature Output Power Control Range 20.0 to 32.0 dBm Output Power Control Modes Closed-loop on specified output power or open-loop on specified gain (compensated for IDU cable loss and temperature variations) Spectral Mask Compliant with FCC CFR 47 Part 24 Phase Noise <-51 dBc double sideband integrated over 10 kHz to 2.5 MHz MER (equalized) 38 dB
IF Cable Compensation Range 15 dB
Spectral inversion No spectral inversion
RECEIVE
RF Input Frequency Range 1870-1885 MHz, Block B 1895-1910 MHz, Block C Frequency Response (any 3 MHz band) 0.6 dB peak-peak IF Output Frequency Range 27-42 MHz Noise Figure at Antenna Port <4 dB including duplexer loss at maximum gain Integrated Gain 55 dB nominal Gain Control Range ±10 dB Output Third Order Intercept Point: +20 dBm at maximum gain Phase Noise <-95 dBc/Hz @ 10 kHz <-51 dBc double sideband integrated over 10 kHz to 2.5 MHz IF Detector Accuracy ±1.0 dB typical Spectral inversion No spectral inversion
Image Rejection > 75 dB
GENERAL
Remote Control Interface Bi-directional signalling with WM4040 Connectors N female, 50 ohms Power Requirement -40.5 to –57VDC operational Power Consumption 60W maximum Operating Temperature Range 10°C to 40°C Mounting Standard 19” (48.3 cm), 2U (3.5”) rack space (3U in dual configuration) Dimensions 19” (w) x 14.9” (d) x 3.5” (h) (48.3 x 37.9 x 8.9 cm) Weight 30.8 lbs. (14kg)
Specifications subject to change without notice. The DOCSIS
TM
acronym belongs to CableLabs
®
VCom Inc.
Approved: C.H.
7
2.0 INSTALLATION
2.1 Unpacking the Unit
Carefully remove the equipment from its packing material and set it on a solid surface, such as a table or desk. If it appears damaged in any way, notify the carrier, and keep all packing materials for inspection by the carrier’s agent.
2.2 Operating Environment
- Front to back cooling; no clearance required above or below, but ample clearance at front and back.
- D to operate at temperatures ranging from 0 to 40 operation at excessive temperature accelerates the deterioration of components. For this reason, measures should be taken to prevent the build up of excessive heat in the rack.
2.3 Power Requirements
All power on the unit is supplied by the WM4040 via a –48VDC connection multiplexed over the IF cable. Only one BST1918 can be connected to a WM4040.
2.4 Rack Mounting
The chassis is designed for standard rack mounting in a 19” equipment rack. It requires 2U (3.50”) of vertical rack space. It should be installed in a rack allowing access to the back of the unit. The transceiver should be isolated from strong RF radiation emanating from local equipment in the rack.
o
C (50 to 104oF). As with all electrical equipment,
2.5 Module Installation/Replacement
1. Power off the desired BST1918 module by disabling the IDU in the corresponding WM4040 module. Ensure that the “DC Power” LED is off.
2. Wait 15 seconds to allow voltage to dissipate on the WM4040 connector, then disconnect the WM4040 and antenna cables from the rear of the corresponding module
3. Using a screwdriver, loosen the corresponding rear panel captive screws
4. Using a screwdriver, loosen the corresponding front panel captive screws until the module is free to pull forward.
5. Remove the module and set off to the side being sure to keep the unit sitting on the bottom guide rails
6. Insert the replacement module and retighten the front panel captive screws
5. Retighten the rear panel captive screws
6. Reconnect to the WM4040 using the included RG-58 cable. If this cable is not long enough to bridge the gap between units, ensure that 50 ohm RG-58 cable is used and the length does not exceed 10ft
7. Turn on the IDU and configure the IF/RF levels using the WM4040
8. Reconnect the rear panel antenna cable
9. Enable the IDU output
VCom Inc.
Approved: C.H.
8
3.0 OPERATION
3.1 Front Panel Description
DDDDIAGRAM
IAGRAM 3.1A: F
IAGRAM IAGRAM
As shown in Diagram 3.1A, the power/control module front panel has 3 indicator LEDs. The BST is entirely configured and queried through the front panel display of the corresponding WM4040 module.
3.1A: FRONT
3.1A: F3.1A: F
RONT P
RONT RONT
PANEL
ANEL
PP
ANEL ANEL
– BST1918
BST1918
––
BST1918 BST1918
DC POWER LED When the green DC POWER indicator is illuminated, the module has been correctly installed and enabled by
the WM4040.
OUTPUT ENABLED LED When the green OUTPUT ENABLED indicator is illuminated, the internal output circuitry is enabled to provide
an RF output. The OUTPUT ENABLED indicator does not necessarily indicate the presence of an output; it only reflects that the module is capable of an RF output if an IF input is applied and the levels configured.
ALARM LED The red ALARM indicator fills two functions – alarm indicator and firmware update indicator. A solid Alarm
LED indicates an alarm condition and detailed alarm information is available by viewing the LCD display of the WM4040 for status and error codes. A flashing Alarm LED indicates that the BST1918 firmware is being updated by the WM4040.
VCom Inc.
Approved: C.H.
9
3.2 Operating Modes
For detailed information on the operating modes and controls, please refer to the WM4040 manual. The BST1918 has the following capabilities:
BST1918 Capabilities: (refer to WM4040 manual for detailed description of modes) WM4040 Mode WM4040 Menu WM4040 Remote
Interface Command
Transmit Frequency Tx XXXXX.XXXXMHz ORF
Output RF ALC Enable/Disable Out RF ALC AE OR
Output RF Threshold Enable Out RF Thres En TE OR
Out RF Thres H S Output RF Threshold Set
Out RF Thres L S
Output RF Power Set Out RF Power Set PS OR
Output RF Attenuation Set Out RF Atten Set ORA
Output IF Attenuation Set Out IF Atten Set OIA
RF Output Enable/Disable Output OE
Automatic Cable Compensation Auto Cable Comp ACE
Downstream Cable Loss IDU-ODU Cble Lss DCL
IDU Temperature IDU Temperature RTM
TS OR
VCom Inc.
Approved: C.H.
10
4.0 REAR PANEL CONNECTIONS
DDDDIAGRAM
IAGRAM 4.0
IAGRAM IAGRAM
4.0A
4.04.0
A: R
: REAR
: R: R
AA
EAR P
EAR EAR
PANEL
ANEL
– BST1918 S
BST1918 SYSTEM
PP
––
BST1918 S BST1918 S
ANEL ANEL
YSTEM
YSTEMYSTEM
WM4040 The BST1918 is connected to the WM4040 by a single IF cable connection which carriers the following
signals:
-48VDC power
Low frequency signaling channel 18-42 MHz (or sub-band) for the upstream received signals 90 MHz high stability frequency reference Sub-band of 555-570 MHz for the downstream-transmitted signal
There is active DC voltage on this cable and caution should be used when connecting and disconnecting the unit. Be sure to have the IDU disabled in the corresponding WM4040 module when handling this cable. An over-current shutdown circuit is used to prevent damage to either the WM4040 or BST1918.
ANTENNA This connector should be tied to the feed cable for the antenna. Both transmit and receive signals are
present on this cable.
VCom Inc.
Approved: C.H.
11
5.0 WARRANTY AND SERVICE POLICIES
5.1 Warranty Statement
VCom warrants its products to be free from defects in workmanship or materials for a period of two years. The warranty begins on the date of the original shipment from VCom to its customer. No claim may be allowed for expenses incurred in installation or use. No other expressed or implied warranties shall apply to the goods sold. VCom is not responsible for delayed shipments, other loss beyond VCom’s control, or consequential damages of any kind arising in connection with the use of its products. This warranty is a return-to-factory warranty only. During the warranty period VCom will at its option, replace, repair or refund the price paid for any item which is returned for service. This warranty does not apply to units that have been physically or environmentally abused.
5.2 Service Policies: How to Return an Item for Service:
Before returning any item for service, an R.M.A. (Returned Material Authorization) number must be assigned by VCom. A unique R.M.A. number will be assigned for each item being returned. When requesting an R.M.A. number, please be prepared to provide the model, VCom serial number, original invoice number, your purchase order number and an adequate fault description. The serial number of a unit can be found on a barcode label similar to the one pictured below. R.M.A. service is available Monday to Friday from 8:30 a.m. to 4:30 p.m. CST (statutory holidays excepted).
To obtain an R.M.A. number you may:
Call: (306) 955-7075, press ‘0’ for Operator, or ‘3’ for Service Dept. Fax: (306) 384-0086 — Attention: R.M.A. Request Email: support@vcom.com
Once an R.M.A. number has been assigned, please refer to it in all correspondence and make certain that all applicable R.M.A. numbers are clearly marked on the outside of each package being returned. You must also ensure that each product is shipped to VCom in its original shipping container (or equivalent) via Prepaid carrier, with appropriate insurance and customs documentation (where required). VCom will not accept collect shipments, damaged shipments or shipments unaccompanied by an R.M.A. number.
For items still under Warranty – Items will be returned from VCom Inc. to its customer via prepaid ground carrier. The customer is responsible for any additional costs incurred, including custom clearance and duties. Any alternate means of shipment must be requested by the customer and will be subject to additional charges.
For items no longer under Warranty – Items will be returned from VCom Inc. to its customer via prepaid ground carrier at the customer’s expense. The customer is responsible for any additional costs incurred, including custom clearance and duties. Any alternate means of shipment must be requested by the customer and will be subject to additional charges.
Shipping Instructions will be provided by the repair center when the RMA number is sent to the customer.
VCom Inc.
Approved: C.H.
12
5.3 Repair Charges and Warranty Exemptions
Items returned beyond the warranty period or items that do not qualify for warranty service are subject to additional out-of-warranty repair charges. Descriptions of these charges and warranty exemptions are below:
1) Repair turnaround time is typically 5-14 business days after receipt of the item at VCom. A Flat Rate Repair Charge will apply to all out-of-warranty items. Flat Rate Repair Charges are subject to change without notice.
2) Any faults due to customer error (i.e. - incorrect set-up or configuration settings) are subject to the current Test Fee and will be exempt from warranty.
3) Items returned with inadequate fault descriptions are subject to the current Test Fee and are exempt from warranty.
4) In the event that no fault is found, the item is subject to the current Test Fee and will be exempt from warranty.
5) Any product exhibiting external damage (either from shipping, improper handling or use) will be subject to inspection. If said damages are determined to be the cause of failure, the item will be exempt from warranty. All repairs to correct the external damage are subject to Time & Materials Charges (parts and labor at current rates).
6) Items with damage caused by unauthorized repairs or by external devices are subject to current out-of­warranty Flat Rate Repair Charges and are exempt from warranty.
7) All products returned for Factory Optioning are subject to the applicable current Option Charge plus Test Fee. Factory-optioned products carry the balance of the original warranty or a 90 day warranty, whichever is greater.
All out-of-warranty repairs must be approved by the customer in writing. No repairs will be made until the
customer’s Purchase Order or Out-Of-Warranty Repair Authorization is received.
VCom Inc.
Approved: C.H.
13
150 Cardinal Place
Saskatoon, Saskatchewan
S7L 6H7
Canada
Tel: (306) 955-7075
Fax: (306) 955-9919
www.vcom.com