Vaxcel T0213, T0214 User Manual

ASSEMBLY AND INSTALLATION INSTRUCTIONS
T0213 / T0214
TO AVOID RISK OF ELECTRICAL SHOCK, BE SURE TO SHUT OFF
WARNING:
NOTES: 1. Before installing, consult local electrical codes for wiring and grounding requirements.
2. Read and save these instructions.
POWER BEFORE INSTALLING OR SERVICING THIS FIXTURE.
Important to Know
1. Read all instructions carefully before installation and operation.
2. If you are not familiar with state and local electrical codes, it is recommended that you consult with a qualified electrician.
3. Before installation, shut off power at the main fuse or circuit breaker box. Be aware that simply turning off the wall switch is not sufficient to prevent an electrical shock.
4. This fixture requires a 120V AC, 60 Hz power source.
5. Do not attempt to take the lantern apart; there are no serviceable parts inside.
6. To avoid sensor damage by lightning or electrical surge, make sure the grounding wire is securely connected.
7. For general safety and to avoid any possible damage to the sensor, be sure the power is switched "off" before replacing the bulb.
Maximum Wattage: 60W Work Temperature: -4ºF ~ 104ºF
Mounting Plate (A)
House Grounding Wire
Wire Nut (E)
Back plate
Features
1. Energy saving fixture.
2. Use the dim-to-bright illumination option where you want some minimum illumination through out the night, such as at your front entrance or garage door. Use the dark-to-bright illumination option where you do not need minimum brightness, such as the backyard or back porch.
3. When in manual override mode, use wall switch to keep the light ON till dawn.
Hardware Package (included)
Mounting Plate (A)
Wire Nut (E)
Mounting Screw (B)
Lock Nut (F)
Green Grounding Screw (C)
Rubber Pad (G)
Fixture
Ball Nut (H)
Outlet Box
Green Grounding Screw (C)
Fixture Grounding Wire
Mounting Screw (B)
Headless Screw (D)
Lock Nut (F)
Fixture Wire
Page 1 / 4
Ball Nut (H)
Rubber Pad (G)
Max Watt: 60W (M) - Type A Incandescent, Halogen or Dimmable LED (not include)
151022
Installation Steps
Turn off the power at fuse or circuit box.
1. Thread two headless screws through the mounting plate, and then secure them with four lock nuts (two on each side of the mounting plate). Adjust the length of the headless screws if necessary. Note: Make sure that the headless screws are lined up horizontally to make the fixture level.
2. Attach mounting plate to the outlet box using two mounting screws.
3. Pull out the wires and grounding wire from the outlet box. Make wire connections using the wire nuts as follows:
---Connect the hot wire (usually black insulation) from the fixture to the black wire from the power source.
---Connect the neutral wire (usually white insulation) from the fixture to the white wire from the power source.
---Attach the fixture grounding wire (usually green insulation or bare wire) to the mounting plate with the green grounding screw, and then connect it to the house grounding wire with the wire nut. Carefully put the wires back into the outlet box.
4. Attach the back plate to the mounting plate by inserting the headless screws, and then secure it with two rubber pads and two ball nuts. NOTE: With silicone caulking compound, caulk completely around where the back plate meets with the
wall surface to prevent water from seeping into the outlet box.
5. Install a bulb (not included). Check relamping label at socket area or packaging for maximum allowed wattage.
Turn on the power at fuse or circuit box.
Function and Operation
MODES OF OPERATION
Choose a mode by sliding the switch on the bottom of the back plate of the fixture. (See Fig.2 ). When power is first applied, the light will turn to high level brightness, wait for 15 seconds to allow the sensor to warm up.
1. TEST MODE (daytime and nighttime operation)
The light will turn to low-level brightness (0%~50% brightness). The light will turn to high-level brightness (100% brightness) when motion is detected, and stay on as long as the motion is continuing. The light will revert to low-level brightness about 5 seconds after motion is no longer detected.
2. 3H MODE (nighttime operation only)
At dusk, the light will turn to high-level brightness (100% brightness). The light will turn to low-level brightness (0% ~50% brightness) automatically after 3 hours. The light will turn to high-level brightness (100% brightness) when motion is detected, and stay on as long as the motion is continuing. When motion is no longer detected, the light will remain on for the predetermined time you set (5~180 seconds), and then revert to low-level brightness you set.
● Light will turn off automatically at dawn, and return to 3 H mode at dusk.
3. 6H MODE (nighttime operation only)
At dusk, the light will turn to high-level brightness (100% brightness). The light will turn to low-level brightness (0% ~50% brightness) automatically after 6 hours. The light will turn to high-level brightness (100% brightness) when motion is detected, and stay on as long as the motion is continuing. When motion is no longer detected, the light will remain on for the predetermined time you set (5~180 seconds), and then revert to low-level brightness you set
● Light will turn off automatically at dawn, and return to 6 H mode at dusk.
4. 0 MODE (nighttime operation only)
● The light will turn to low level brightness (0%~50% brightness) at dusk. The light will turn to high-level brightness (100% brightness) when motion is detected, and stay on as long as the motion is continuing. When motion is no longer detected, the light will remain on for the predetermined time you set (5~180 seconds), and then revert to low level brightness you set.
● Light will turn off automatically at dawn, and return to 0 H mode at dusk.
Page 2 / 4
151022
Loading...
+ 2 hidden pages