Vax Zero Advance VZ-302 Instruction Manual

Vaxcare:
AUST: 1300 36 4040
NZ: 0800 800 900
Vaxcare:
AUST: 1300 36 4040
NZ: 0800 800 900
www.vax.com.au
Instruction Manual
• NSW/ACT
Unit 2, 30 Heathcote Road, Moorebank, NSW 2170 Telephone: (02) 9602 6800 Facsimile: (02) 9602 6900
• VICTORIA/TASMANIA
Unit 3, 46 Burgess Road, Bayswater North, VIC 3153 Telephone: (03) 9761 7160 Facsimile: (03) 9761 7175
• SOUTH AUSTRALIA/ NORTHERN TERRITORY
Unit 3, 75-77 Grange Road, Welland, SA 5007 Telephone: (08) 8340 2222 Facsimile: (08) 8346 7933
• QUEENSLAND
186 Kerry Road, Archerfield, QLD 4108 Telephone: (07) 3216 7350 Facsimile: (07) 3216 7375
• WESTERN AUSTRALIA
296 Victoria Road, Malaga, WA 6090 Telephone: (08) 9247 8100 Facsimile: (08) 9247 8192
• VAX APPLIANCES NEW ZEALAND
27 Clemow Drive Mt Wellington, Auckland Telephone: (09) 5736220 Facsimile: (09) 5736224 Email: vaxnz@vax.co.nz
AUST. & NZ BRANCHES
Please register your warranty. Send in your completed Warranty Card.
If you require any further assistance or advice about any
VAX please call VAXCARE on
1300 36 4040 (Australia - cost of a local call)
and 0800 800 900 (NZ)
VAX Appliances (Australia) Pty Ltd
A.C.N. 009099736
296 Victoria Road Malaga Western Australia 6090.
EMAIL: vaxcare@vax.com.au
WEBSITE: www.vax.com.au
VAXCARE
MODIFIED MAY 2008 P/N Z-8 000
Please read carefully before using this cleaner.
Always fully extend the mains cable before use.
Retain for future reference.
VZ-302
Part N umber: Z -8000
Bagless Cylinder
2
1. Safety Information
FOR HOUSEHOLD USE ONLY
When using the vacuum cleaner, basic safety precautions should always be observed, including the following:
1. Only use the vacuum cleaner indoors on dry surfaces.
2. Turn off the vacuum cleaner controls before connecting or disconnecting from the mains supply.
3. Always unplug the vacuum cleaner before connecting or disconnecting the vacuum hose and accessories.
4. This appliance is not intended for use by young or infirm persons unless they have been adequately supervised by a responsible person to ensure that they can use the appliance safely.
Young children should be supervised
to ensure that they do not play with the appliance.
5. Use only as described in this manual.
Use only the manufacturer’s recommended
attachments.
6. Do not use the vacuum cleaner if it has been dropped, damaged, left outdoors or dropped into water. Do not use the vacuum cleaner with a damaged cord or plug. If the supply cord or plug is damaged, return the vacuum cleaner to a Vax Authorised Service Agent for examination, repair or adjustment.
7. Do not pull or carry by the cord. Do not use the cord as a handle, close a door on the cord or pull the cord around sharp edges or corners. Do not run the vacuum cleaner over the cord. Keep the cord away from heated surfaces.
8. Do not handle the plug or vacuum cleaner with wet hands. Do not use outdoors or on wet surfaces.
9. Do not put any objects into openings. Do not use with any openings blocked and do not restrict air flow. Keep all openings free of dust, lint, hair or anything that may reduce airflow.
10. Keep hair, loose clothing, fingers and all parts of the body away from openings and moving parts.
11. Do not pick up hot coals, cigarette butts, matches or any hot, smoking or burning objects.
12. Do not pick up flammable or combustible materials (lighter fluid, petrol, kerosene, etc) or use in the presence of explosive liquids or vapours.
13. Do not vacuum up harmful or toxic material (chlorine bleach, ammonia, drain cleaner, etc).
14. Do not vacuum up hard or sharp objects such as glass, nails, screws, coins, etc.
15. Do not use without the filters in place.
16. Take extra care when vacuuming on stairs.
17. Keep vacuuming area well lit.
18. Store the vacuum cleaner indoors in a cool, dry area.
19. Turn off the on/off switch before unplugging the vacuum cleaner.
WARNING: Always switch off and unplug the vacuum cleaner from the electrical outlet before assembling, opening or emptying the dirt container, or before connecting/disconnecting the attachments.
CAUTION: The vacuum cleaner is a very powerful unit. Before plugging the cord into the electrical outlet, make sure the switch is in the ‘off’ position.
IMPORTANT: If the inlet, hose or telescopic tube is blocked, switch off the vacuum cleaner and remove the blockage(s) before re-starting.
IMPORTANT: Washing filters improves vacuum performance. Make sure all the filters are completely dry before inserting back into the vacuum cleaner.
This vacuum cleaner is intended for household use only and not for commercial or industrial use.
Motor Thermostat
IMPORTANT: The motor is equipped with a
thermal cut-out. If for any reason, the vacuum cleaner should over-heat, the thermostat will automatically turn the unit off. Should this occur, unplug the vacuum cleaner from the electrical outlet and turn off the switch. Remove the dirt container and empty. Clean or replace the filters. Allow the cleaner to cool for approximately one (1) hour before restarting.
7
7. Cleaning Blockages
WARNING: To reduce the risk of injury, the
power cord must be disconnected before performing maintenance / troubleshooting checks.
1. Turn the vacuum cleaner off and unplug from the electrical outlet.
2. The flexible hose can be disconnected from the vacuum cleaner by pressing hose release button and pulling hose away from the machine. Remove any blockages found then reconnect the hose securely.
8. Storage
IMPORTANT: Always unplug the vacuum
cleaner from the electrical outlet and rewind the power cord as directed before storing.
NOTE: Always store the vacuum cleaner base down.
Troubleshooting
WARNING: To reduce the risk of injury,
unplug vacuum cleaner before servicing.
PROBLEM: Vacuum cleaner won’t run
Cause: Not properly plugged into electrical outlet.
Solution: Plug in firmly.
Cause: No electricity in the electrical outlet. Solution: Check fuse or breaker.
Cause: On/off switch not turned on. Solution: Push on/off switch to on.
Cause: Motor thermostat tripped. Solution: Switch off and unplug the vacuum
cleaner. Leave for one (1) hour before switching the vacuum cleaner back on.
Cause: Blown fuse/tripped breaker. Solution: Reset house circuit breaker or
replace fuse.
PROBLEM: Cleaner won’t pick up/loss of suction
Cause: Dirt container not installed properly. Solution:
Review dirt container replacement.
Cause: Dirt container full or blocked. Solution: Empty dirt container.
Cause: Clogged filters. Solution: Remove, clean and replace filters.
PROBLEM: Accessories won’t pick up
Cause: Accessories not attached correctly. Solution: Refer to section 5.
PROBLEM: Dust escaping from the vacuum cleaner
Cause: Dirt container full. Solution: Empty dirt container.
Cause: Dirt container not installed correctly. Solution: Review dirt container
replacement.
Cause: Filter not installed completely. Solution: Remove, clean and replace filters.
VAXCARE Service & Help: AUSTRALIA 1300 36 4040 NEW ZEALAND 0800 800 900
Any queries or concerns about using the Vax, call VAXCARE. Please make a note of the model number of the appliance before calling. (Aust only: Mon-Fri. 10.00am to 6.00pm. EST) Calls are charged at the local rate. An answerphone is available out of these hours.
There are over 300 approved Vax Service Agents in Australia and New Zealand. For the nearest Service Agent, please refer to your Vax warranty or call VAXCARE or visit www.vax.com.au
Technical Specification
Name: Zero Advance Part No: Z8000 Model: VZ-302 Voltage: 220-240V~50Hz Wattage: 1600W Capacity: 2.5 litres approx Filters: Cyclone separator - wipe clean Pre-motor filter - washable Post-motor filter - washable Cord length: 6m (approx) Weight: 8.55kg (approx)
Subject to technical change without notice.
3
2. Parts Overview
1 Hose inlet 2 Dirt container 3 Dirt container handle 4 Dirt container release button 5 Carry handle 6 Auto cord rewind button 7 On/off button 8 Pre-motor filter cover 9 Combination floor head park clip
10 Rubber moulded wheel
Accessories:
11 Telescopic tube 12 Combination floor head 13 Dusting tool 14 Crevice tool 15 Upholstery tool 16 Hose
6
Remove foam filter
Open the pre motor filter cover at the rear of the machine and remove the foam filter with the plastic housing (Fig.7/1).
Fig.7/1
Foam filter
Clean foam filter
Separate the filters by removing the foam filter from its plastic housing. Tap the plastic filter housing on the inside of a rubbish bin to remove excess dust and dirt (Fig.7/2).
Fig.7/2
Filter housing
Wash foam filter
Hold foam filter under running water to wash (Fig.7/3). Squeeze excess water out of filter. Allow filter to thoroughly air dry before replacing.
Replace foam filter
Return foam filter with plastic housing to cleaner and replace pre-motor filter cover into place to secure.
Fig.7/3
Remove HEPA filter
The HEPA filter is located under the dust bin. Remove the dust bin. Press tab on side of filter cover and remove the cover to expose HEPA filter. Lift out HEPA filter (Fig.7/4).
Fig.7/4
Exhaust HEPA filter
Filter cover
Wash HEPA filter
The post-motor filter can be rinsed in warm water (max 40°C). Allow to thoroughly air
dry before replacing.
NOTE: Do not use any detergents or boiling water to wash the filters. Vax recommends washing the filter every 9-12 months.
Replace the filter, filter cover and dust bin before restarting the vacuum cleaner.
Clean HEPA filter
Tap the HEPA filter on the inside of a rubbish bin to remove excess dust and dirt from filter (Fig.7/5).
Fig.7/5
3. How to Assemble
IMPORTANT: Always unplug the vacuum
cleaner from the electrical outlet before assembling or removing the accessories.
1. Insert the flexible hose (Fig.3/1) into the inlet on the main body of the vacuum cleaner until it clicks into lock position.
2. Push the telescopic extension tube on to the end of the handle (Fig.3/2).
3. The telescopic tube can be lengthened or shortened by pushing the button in and sliding the tube apart or together as required (Fig.3/3).
4. Fit the combination floor head by pushing onto the extension tube (Fig.3/4).
4. How to Operate
Cord Release
Fully unwind the power cord. A yellow mark on the power cord indicates the recommended cord length. Do not exceed the cord length beyond this mark.
On/off Button
1. Insert the plug into the electrical outlet.
2. Press the on/off switch located on the top of the vacuum cleaner, to switch on the vacuum cleaner and press the button again to turn the vacuum cleaner off.
Carpet Cleaning
For carpet and rug cleaning, press the rocker switch on the combination floor head to raise the brushes.
Hard Floor Cleaning
For hard floor cleaning, press the rocker switch on the combination floor head to lower the brushes.
Cord Rewind
To rewind the power cord, press the cord rewind button located on the top of the vacuum cleaner, and guide the power cord with one hand. Rewind 1-11/2 metres of cord at a time. This will prevent the cord from whipping which could cause damage or injury.
Carry Handle
Use the carry handle located at the rear end of the vacuum cleaner to move from room to room.
Hose Storage
For convenience there is a parking slot located at the rear of the vacuum cleaner where the floor tool and hose can be parked for carrying and storage.
4 5
5. Accessories
1. The accessories can be attached directly to the handle by removing the telescopic tube and pushing in the desired accessory.
2. The accessories can also be attached to the telescopic extension tube for extra reach. Remove the combination floor head and push on the desired accessory.
Dusting brush:
for delicate surfaces
Upholstery tool:
for carpet, upholstery and
stairs etc.
Crevice tool:
for crevices, corners and
cracks, etc.
6. Dirt Container & Filters:
Removal & Replacement
IMPORTANT: Always unplug the vacuum
cleaner from the electrical outlet before removing the dirt container.
IMPORTANT: Do NOT use the vacuum cleaner without ALL of the filters in place.
Emptying the dirt container
1. Press down the dirt container release button located on the top of the vacuum and lift the dust container to remove.
2. Hold the dirt container over a bin and press the quick release buttons to empty the container (Fig.6/2). The top button empties finer dust & the bottom button empties larger dirt.
3. Tap and shake the bin to remove all the dust and dirt from this container.
4. Once all the dust is removed, carefully close the dirt container flap. A click will be heard when closed. Replace the dirt container.
Cleaning the cyclone separator
1. Twist and pull the dirt container bin off the cyclonic separator. The dirt container bin may be wiped clean.
2. The separator should be cleaned with a soft brush and wiped with a damp cloth.
3. Leave the separator to dry completely before replacing.