10. Troubleshooting
WARNING: To reduce the risk of injury,
unplug the vacuum cleaner before servicing.
PROBLEM: Vacuum cleaner won’t run
Cause:
Not properly plugged into electrical outlet.
Solution: Plug unit in firmly.
Cause: Vacuum cleaner not turned on. Solution: Press on/off button.
Cause: No electricity in the electrical outlet. Solution: Check fuse or breaker.
Cause: Blown fuse/tripped breaker. Solution: Reset circuit breaker or replace fuse.
Cause: Motor thermostat has tripped. Solution: Switch off and unplug the vacuum
cleaner. Leave for one (1) hour. See page 2.
PROBLEM: Cleaner won’t pick up/ loss of suction
Cause: Dust bag not installed correctly. Solution: Review dust bag removal and
replacement.
Cause: Dust bag full or blocked. Solution: Replace dust bag. Empty/clean/
replace cloth bag
Cause: Clogged filter. Solution:
Remove/replace with new filter VCC-05.
Remove wash/replace HEPA filter VCC-07.
Cause: Blockage in hose. Solution: Disconnect hose, remove the
obstruction then re-fit.
PROBLEM: Accessories won’t pick up
Cause: Accessories are not attached correctly. Solution:
Refer to page 5 for fitting information.
PROBLEM: Dust escaping from the vacuum cleaner
Cause: Dust bag full. Solution:
Dispose of paper dust bag, replace
with a new one or empty/clean/replace cloth bag.
Cause: Dust bag not installed correctly. Solution: Review dust bag removal and
replacement.
Cause: Hose is not installed correctly. Solution: Review hose installation.
Cause: Filter not installed completely. Solution: Review filter removal and
replacement.
8. VAXCARE Service & Help: AUSTRALIA 1300 361 505 NEW ZEALAND 0800 800 900
If you have any queries or concerns about using your Vax, call VAXCARE. Please make a note of the part number or model number of the appliance before calling. (Aust only: Mon-Fri. 8:30am - 5:30pm. EST) Calls are charged at the local rate. An answerphone is available outside of these hours. We will return your call the next working day. There are over 300 approved Vax Service Agents in Australia and New Zealand. For the nearest Service Agent, please refer to your Vax warranty or call VAXCARE or visit www.vax.com.au
9. Technical Specification
Voltage 220-240V~50Hz Wattage: 1400W Model VCC-05 1500W Model VCC-07 Capacity: 6 litres max Model VCC-05 8 litres max Model VCC-07 Filters: Pre-motor filter VCC-05 only HEPA Model VCC-07 only Cord length: 12 metres Weight: 7.2kg Model VCC-05
8.5kg Model VCC-07
Subject to technical change without notice.
12 Month VAXCARE Commercial Warranty
Commercial User Guide.indd 1 5/10/07 11:12:18 AM
2 7
1. Safety Instructions
For Commercial Use Only
When using the vacuum cleaner, basic safety precautions should always be observed, including the following:
1. This appliance is for dry use only and is not to be used or stored outdoors or in wet conditions.
2. Turn off the vacuum cleaner controls before connecting to or disconnecting from the mains supply.
3. Always unplug the vacuum cleaner before connecting or disconnecting the vacuum hose.
4. This appliance is not intended for use by young or infirm persons unless they have been adequately supervised by a responsible person to ensure that they can use the appliance safely.
Young children should be supervised
to ensure that they do not play with the appliance.
5. Use only as described in this manual. Use only the manufacturer’s recommended attachments. This appliance is suitable for commercial use, for example in hotels, schools, hospitals, factories, shops, offices and rental businesses.
6. Do not use the vacuum cleaner with a damaged cord or plug. Do not use the vacuum cleaner if it has been dropped, damaged, left outdoors or dropped into water. Return the vacuum cleaner to a Vax Authorised Service Agent for examination, repair or adjustment.
Regularly examine the power cord for
damage, such as cracking or ageing. If damage is found replace the cord before further use.
7. Do not pull or carry by the cord. Do not use the cord as a handle, close a door on the cord or pull the cord around sharp edges or corners. Do not run the vacuum cleaner over the cord. Keep the cord away from heated surfaces.
8. Do not handle the plug or vacuum cleaner with wet hands. Do not use outdoors or on wet surfaces.
9. Do not put any objects into openings. Do not use with any openings blocked and do not restrict air flow. Keep all openings free of dust, lint, hair or anything that may reduce airflow.
10. Keep hair, loose clothing, fingers and all parts of the body away from openings and moving parts.
11. Do not pick up hot coals, cigarette butts, matches or any hot, smoking or burning objects.
12. Do not pick up flammable, hazardous dust or combustible materials (lighter fluid, petrol, kerosene, etc) or use in the presence of explosive liquids or vapours.
13. Do not vacuum up harmful or toxic material (chlorine bleach, ammonia, drain cleaner, etc).
14. Do not vacuum up hard or sharp objects such as glass, nails, screws, coins, etc.
15. Do not use without the filters in place.
16. Use extra care when vacuuming on stairs.
17. Keep vacuuming area well lit.
18. Store the vacuum cleaner indoors in a cool, dry area.
19. Turn off the switch before unplugging.
WARNING: Always switch off and unplug the vacuum cleaner from the electrical outlet before assembling, opening or emptying the dirt container, or before connecting/disconnecting the attachments.
CAUTION: The vacuum cleaner is a very powerful unit. Before plugging the cord into the outlet make sure the switch is in the ‘off’ position. Hold the vacuum cleaner firmly when starting.
IMPORTANT: If the inlet or hose is blocked, switch off the vacuum cleaner and remove the blockage(s) before re-starting.
IMPORTANT: Cleaning filters improves vacuum performance. Make sure all filters are replaced back into the vacuum cleaner before using.
This appliance is suitable for commercial use. PLEASE KEEP THESE INSTRUCTIONS FOR FURTHER USE.
Motor Thermostat IMPORTANT: The motor is equipped with a
thermal cut-out. If for any reason, the vacuum cleaner should over-heat, the thermostat will automatically turn the unit off. Should this occur, unplug the vacuum cleaner from the electrical outlet and turn off the switch. Remove the dirt container and empty. Clean the filters. Allow the cleaner to cool for approximately one (1) hour before re-starting.
7. Clearing Blockages
WARNING: To reduce the risk of injury,
the power cord must be disconnected before performing maintenance or troubleshooting checks.
Turn vacuum cleaner off and disconnect the power plug from the electrical outlet. The flexible hose can be disconnected from the vacuum cleaner by rotating anti-clockwise and pulling away from the machine. Remove any blockages found then reconnect the hose (Fig.7/1).
HEPA Pre-motor Filter (Model VCC-07 only)
1. Turn off the vacuum cleaner and unplug it from the electrical outlet.
2. Unclip the retainer clip on the top of the vacuum cleaner and lift up to gain access to the dirt container department (Fig.6/8).
3. The HEPA pre-motor filter is found in the centre of the dirt container. Rotate the filter clockwise to remove (Fig.6/9).
Fig.6/9
NOTE: Do NOT use any detergents or boiling water to wash the filter.
5. Replace the HEPA filter back in the machine before use.
4. Gently tap the filter against the side of the rubbish bin to remove excess dirt. The filter may then be rinsed in cool water. Allow to thoroughly air dry before replacing.
Replace the filter every 3-6 months
depending on useage or when the filter becomes discoloured (Fig.6/7).
Commercial User Guide.indd 2 5/10/07 11:12:19 AM