Vax Upright Steam Cleaner V-083, Upright Steam Cleaner V-083Q Instruction Manual

Page 1
www.vax.co.uk
Please read carefully before using this cleaner.
Always fully extend the mains cable before use.
R
e
tain f
or future reference.
0870 6061248
instruction manual
Steam cleaner
Vax model number:
V-083 V-083Q
Vax V-083(Q) User Guide.qxd 25/1/07 11:11 Page 1
Page 2
V-083(Q)
1. Diagram
www.vax.co.uk
2
parts overview
1 Hanging hook 2 Steam regulator 3 Control switches 4
Water tank cap 5 Water tank 6 Lock button 7 Floor head 8 Towel grips
9 Brush slides 10 Cord holder 11 Lower handle 12
Power cord
13
C
or
d holder 14 Squeegee tool 15
Utility t
ool
16 Deflector nozzle
17 Floor cloth 18 Utility cloth 19 Spot brush 20
Nozzle brush
21
No
zzle pin 22 Funnel 23
Carpe
t glide base
(V-083Q only)
24 Steam comb (V-083Q only)
A B
C D
A On/off switch B Steam switch C Power ON light (red) D Steam ready light (green)
1
2
3
4
5
6
7
8
9
10
11
12
1
3
Fig.1/1
17
14
15
16
19
22
20
21
18
Accessories
24
corner gliders
23
Vax V-083(Q) User Guide.qxd 25/1/07 11:11 Page 2
Page 3
3
Vax Careline 0870 606 1248
safety information
2. Safety Information
For Household Use Only
When using the steam cleaner, basic safety precautions should always be observed, including the following:
1. Do not leave the steam cleaner unattended when plugged in. Unplug it from the socket when not in use.
2. To prevent electric shock do not use outdoors.
3. Not to be used as a toy. Close supervision is necessary when used near children or the infirm.
4. Use only as described in this manual.
5. Do not use with a damaged cord or plug. If the supply cord and/or plug is damaged, they must be replaced by the manufacturer, a Vax Service Agent or similarly qualified persons in order to avoid hazard.
6. Do not pull or carry by the cord, use the cord as a handle, allow the cord to come into contact with hot or sharp surfaces or close a door on the cord.
7. Do not unplug by pulling on the cord.
8. Do not handle the plug or cleaner with wet hands.
9. Do not put any objects into openings or operate with openings blocked.
10. Do not use without the tank cap in place.
11. Turn off all controls before unplugging.
12. Do not use an extension cord.
13. Store indoors, put away after use to prevent tripping accidents.
14. Using improper voltage may result in damage to the steam cleaner and possible injury to the user. The correct voltage is listed on the rating label.
15. This steam cleaner is intended for household use only.
16. A hazard may occur if the steam cleaner runs over the power cord.
17. Never immerse the steam cleaner in water or other liquids.
18. K
eep the s
team cleaner away from the rain and moisture. The steam cleaner is not suitable for outdoor use.
19.
Only use the s
team cleaner in containers/pools that
are not filled with water or other liquids.
20.
Do no
t operate the steam cleaner without water in
the tank. Always top up with water in good time.
21. Empty the water tank when the steam cleaner is not in use.
22. Never fill the tank with anything other than water. Never put additives (such as perfume, stain remover or products containing alcohol) in the water as they
may damage the steam cleaner or make it dangerous to use.
23. Always remove the mains plug and handle the steam cleaner with care when topping up with water.
24. Do not overfill the tank. Do not exceed the maximum prescribed filling level. Please use the funnel included.
25. Ensure that the water tank’s closure cap has been screwed down fully before use.
26. Do not touch any hot areas on the steam cleaner. It is
normal for the steam cleaner to heat up during operation.
27. Do not use the steam cleaner to treat any items of clothing that are still being worn on the body.
28. The force and heat of the steam may have an adverse effect on some materials. Always check whether a surface is suitable for treatment with the steam cleaner by carrying out a test beforehand on a concealed area.
29. Always include these operating instructions if passing the steam cleaner onto a third party.
30. Never aim the steam cleaner at people, animals or plants (risk of scalding!) Do not aim the steam cleaner at electrical systems or wires.
31. Please always switch the appliance off and remove the mains plug from the socket if leaving the work area.
32. Accessories become hot during use- allow them to cool down before handling.
33. Maintain and clean the steam cleaner only when the unit is cold.
Steam Release Safety Feature
IMPORTANT: This steam cleaner is equipped
with a steam release valve mechanism, located at the rear of the steam generator. In event of a steam flow blockage, the safety valve is designed to release the steam. Regular cleaning of the steam chamber and nozzle is therefore recommended to avoid such an occurr
ence. If the steam is released from the safety valve, stop cleaning and unplug the steam cleaner from the electrical outlet. Allow the steam cleaner to cool down thoroughly for at least one hour. After this time, clean the steam chamber and nozzle following the instructions in section 6.
If steam is still being released from the safety valve after cleaning, contact a Vax Service Agent.
!
Vax V-083(Q) User Guide.qxd 25/1/07 11:11 Page 3
Page 4
www.vax.co.uk
4
assembly / operation
3. How to Assemble
IMPORTANT: Never unscrew the tank cap during use.
IMPORTANT: Never fill the tank directly from a tap. Use a jug and the funnel provided.
IMPORTANT: Do not operate a damaged appliance or damaged accessories.
IMPORTANT: This steam cleaner is not intended for commercial use.
NOTE: Carpets should be dry vacuumed thoroughly before using the steam cleaner.
NOTE: If the supply cord is damaged, it must be replaced by the manufacturer, a Vax Service Agent or similarly qualified persons to avoid hazard.
Place the steam cleaner in a horizontal position and remove the water tank cap. Use the funnel provided to slowly fill the water tank with clean water. Replace the cap securely (Fig3/1).
Insert the power plug into an electrical outlet. Make sure the steam cleaner is switched off.
Press the on/off switch located on the handle to switch the steam cleaner on.
The red heater “ON” light should now be illuminated.
Press the steam switch to the “ON” position.
After approximately 30 seconds the green “Steam Ready” light should come on.
Turn the Steam regulator control to maximum and point the steam nozzle towards a cloth or sink for approximately 10-15 seconds, to stabilise the flow and produce a continuous steam.
Ensure the steam switch is turned off before connecting the floor head or an
y of the other cleaning accessories.
4. How to Operate
Align the hole in the side of the floor head with the lock button on the main body of the steam cleaner. Ensure that the lock button clicks firmly into place (Fig4/1).
Connect the floor cloth to the floor head by using the towel grips (Fig4/2).
Turn the steam switch on.
Carpet Cleaning
When cleaning carpets and rugs, leave the steam regulator control set to “maximum”. Use slow backward strokes and lift the floor head slightly during forward strokes to reduce friction between the cloth and the carpet.
N.B Do not press the appliance hard against the carpet.
For large carpeted areas
(Model: V-083Q only)
For freer movement of the steamer over larger carpeted areas the carpet glide attachment can be used.
De
tach and r
emo
v
e the s
team comb section from the
carpet glide attachment.
Fold the cloth and place inside the carpet glide base.
!!!
!
Fig.3/1
Fig.4/1
Fig.4/2
Vax V-083(Q) User Guide.qxd 25/1/07 11:11 Page 4
Page 5
5
Vax Careline 0870 606 1248
operation
Secure the floor head inside the carpet glide base and connect the cloth to the attachment by using the towel grips (Fig.4/3).
Use slow forward and backward cleaning strokes over the desired area.
For carpets and rugs – leave the steam regulator control set to “maximum”
For flat pile – Unscrew and remove the corner gliders
Hard Floor Cleaning
Reduce the steam flow to a lower setting by turning the steam control regulator. Use both forward and backward strokes across the floor area.
N.B When the cloth becomes very wet, rinse out the moisture, use the reverse side or replace with a clean, dry cloth. If the towel becomes too dirty, rinse out the dirt, use the reverse side or replace with a clean, dry cloth.
Stubborn Stains
For removing stubborn stains or embedded grime on hard surfaces, fold and attach the cloth leaving the brushes underneath the floor head visible. (Fig4/4).
Move the brush sliders so that the brushes appear underneath the floor head. Move the brushes backwards and forwards over the selected area.
N.B Do not use the brushes for routine carpet and hard floor cleaning as unnecessary scrubbing may cause damage. The brushes should only be used for removing stubborn stains and grime.
Carpet Pile Rejuvenation
(
Model: V-083Q only)
To rejuvenate flattened carpet piles, remove the cloth and connect the carpet glide base to the floor head with the steam comb section in place.
IMPORTANT: The housing and accessories
become hot during operation. Allow the steam cleaner to cool down before changing the accessories. Never open the water tank cap whilst the steam switch is on.
Fig.4/4
Cloth
Fig.4/3
!
Fig.4/5
Vax V-083(Q) User Guide.qxd 25/1/07 11:11 Page 5
Page 6
www.vax.co.uk
6
accessories / maintenance
5. Accessories
The accessories can be attached to the main body of the steam cleaner by removing the floor head. Press the lock button in to remove the floor head.
Fit the required accessory by aligning the hole in the side of the accessory with the lock button on the main body of the steam cleaner. Ensure that the lock button clicks firmly into place.
Squeegee: For cleaning glass and mirror panels. Use the squeegee at a very low steam flow. Achieve this by adjusting the steam regulator. A cloth can be used to wipe the blade and remove excess water during usage. For small window panels, remove the squeegee tool and spray the steam directly onto the surface. Use the squeegee separately to wipe away the moisture.
Spot Brush: For cleaning the grout between tiles or stubborn marks and stains on hard surfaces. Use at medium or high steam flow.
Utility Tool: For cleaning tiled surfaces, cabinets and worktops in kitchens and bathrooms. Use on a low to medium steam flow. Cover the utility tool with the elasticised cloth (Fig5/1).
Deflector Nozzle: For cleaning sanitary ware such as toilet bowls, taps or drain covers. Use this nozzle at maximum steam flow. Point it directly at non-permanent stains on carpets or upholstery whilst holding a clean cloth near the stained area to capture any loosened dirt.
NOTE: When the steam cleaner is used for cleaning in the o
v
erhead position, increase the steam flow to maximum and allow approximately 30 seconds for the steam to be generated in full. Now the flow can be reduced to the level required for the particular accessory being used. Shak
e the s
team cleaner gen
tly to ensure that the weighted tubing inside the tank is in the correct (immersed) position.
6. Maintenance
After Each Use
NOTE: When you have finished steam cleaning, ensure that both the power switch and steam switch are turned off and that the plug is removed from the electrical outlet.
Empty any remaining water from the tank by unscrewing the water tank cap and turning the steam cleaner upside down. This should be done over a sink or outdoors.
Store the steam cleaner by using the hanging strap at the top of the handle if needed.
Cleaning the Steam Generator
IMPORTANT: Only follow these instructions
when the steam cleaner is completely cooled down. Also ensure that the plug is removed from the electrical outlet.
Twist the steam nozzle, releasing it from its locked position. Pull upwards; this will remove it completely from the steam chamber (Fig6/1).
Insert the nozzle brush into the chamber (Fig6/2).
!
Fig.6/1
Fig.6/2
Fig.5/1
Vax V-083(Q) User Guide.qxd 25/1/07 11:11 Page 6
Page 7
7
Vax Careline 0870 606 1248
maintenance / troubleshooting
Rotate the brush while pulling it in and out of the chamber.
Insert the steam nozzle back into the chamber and turn it clockwise to lock back into position.
N.B Vax recommends cleaning the chamber after every 12-15 uses to ensure optimum performance.
Unblocking the Steam Outlet
If steam flow appears reduced, the steam nozzle may be blocked.
Insert the nozzle pin into the centre of the steam nozzle. This will clear any blockage that may have formed.
Cleaning the Cloths
Both the floor and utility tool cloths can be machine washed (60ºC max). For heavy soiling, soak the cloths in warm water and detergent or a mild stain remover. Allow to dry completely before storing.
7. Troubleshooting
WARNING: To reduce the risk of personal injury,
unplug the steam cleaner before servicing.
PROBLEM: Steam cleaner has no power
Cause:
Steam cleaner is not properly plugged into an electrical outlet or is not switched on.
Solution: Insert the plug into an electrical outlet and
switch the steam cleaner on.
Cause: The socket is faulty.
Solution: Check the socket by unplugging the steam
cleaner and plugging in a different appliance.
Cause: The power cable is damaged.
Solution:
Have the cable replaced by a Vax Service Agent.
PROBLEM: No steam is emitted when the steam
cleaner is on.
Cause:
The water tank is empty.
Solution: Top up with water.
Cause: The steam nozzle is blocked.
Solution: Refer to section 6.
Cause: Despite the green light, the steam switch is
not activated properly.
Solution: Press down the steam switch fully.
Cause: The weighted tubing inside the tank is not in
the correct (immersed) position.
Solution: Shake the steam cleaner gently.
PROBLEM: Only a very small amount of steam flows
out of the steam cleaner.
Cause:
The steam regulator is set to minimum.
Solution: Turn the steam controller until sufficient
steam is emitted.
!
Vax V-083(Q) User Guide.qxd 25/1/07 11:11 Page 7
Page 8
www.vax.co.uk
8
uk service / technical specification
10. UK Service & Help
Vax Care 0870 6061248
Monday-Friday 9.00am to 5.00pm.
An answerphone is available outside of these hours. Any queries or concerns about using the Vax, call the Vax Careline. Calls are charged at the UK national rate.
Please make a note of the serial number and model number of the carpet cleaner before calling. There are over 400 approved Vax Service Agents in the UK. For the nearest Service Agent, please call the Vax Careline.
www.vax.co.uk
11. Technical Specification
Voltage: 220-240V ~50Hz Wattage: 1400W Capacity: 1.2 litres approx Cord length: 4.6m approx Weight: 3kg
Subject to technical change without notice.
Vax V-083(Q) User Guide.qxd 25/1/07 11:11 Page 8
Page 9
9
Vax Careline 0870 606 1248
This page has been left intentionally blank.
Vax V-083(Q) User Guide.qxd 25/1/07 11:11 Page 9
Page 10
www.vax.co.uk
10
This page has been left intentionally blank.
Vax V-083(Q) User Guide.qxd 25/1/07 11:11 Page 10
Page 11
11
Vax Careline 0870 606 1248
This page has been left intentionally blank.
Vax V-083(Q) User Guide.qxd 25/1/07 11:11 Page 11
Page 12
---
EEC STATEMENT OF COMPLIANCE
Manufacturer/EEC importer: Vax Limited, hereby on our own responsibility, declare that the products
V-083/V-083Q Upright Steam Cleaner are manufactured in compliance with the following Directives:
Safety: 2006/95/EC Low Voltage Directive
EMC: 89/336/EEC Electromagnetic Compatibility Directive
W
as
t
e electrical pr
oducts should no
t be disposed of with household waste. Please recycle where
facilities exist. Check with your Local Authority or retailer for recycling advice.
Vax Ltd., Kingswood Road, Hampton Lovett, Droitwich, Worcestershire, WR9 OQH, UK
email: info@vax.co.uk - website: www.vax.co.uk
Vax V-083(Q) User Guide.qxd 25/1/07 11:11 Page 12