Vax Oasis Complete V-133 Instruction Manual

www.vax.co.uk
Please read carefully before using this cleaner.
Always fully extend the mains cable before use.
Retain for future reference.
Vax careline
0870 6061248
instruction manual
Vax model number:
V-133
V-133 OasisComp User Guide v5.qxd:V-133 Oasis User Guide 8/9/08 14:44 Page 1
Oasis
1. Diagram
www.vax.co.uk
2
parts overview
22
1
3
23
25
12
13
10
11
9
14
15
16
2
4
8
20
3
2
6
7
21
1
2
Fig.1/1
4
19
19
18
2
3
1 Hand grip
2 Solution trigger 3 Hose 4 Clean solution tank cap / measuring cup 5 Dirty water tank “front panel” 6 Handle release pedal 7 Solution tube connection 8 Nozzle 9 Brush indicator
10 Brush speed selector
11 Hood 12 Dirty water tank 13 Dirty water tank lid
14 Clean solution tank 15 Clean solution tank handle 16 Carrying handle 17 Stair/upholstery nozzle 18 Cord hooks 19 Hose holder 20 Cord clip 21 Hose hook 22 Dirty water tank latches 23 Spinscrub hand tool 24 Hose hook 25 Clean surge button 26 Bare floor adaptor
5
26
V-133 OasisComp User Guide v5.qxd:V-133 Oasis User Guide 8/9/08 14:44 Page 2
3
V
ax Careline 0870 606 1248
safety information
2. Safety Information
FOR HOUSEHOLD USE ONLY.
When using the vacuum cleaner, basic safety precautions should always be observed, including the following:
1. Do not leave the carpet washer unattended when
plugged in. Unplug it from socket when not in use.
2. To prevent electric shock do not use outdoors.
3. Nottobe used as a toy. Children should be supervisedto
ensure that they do not play with the appliance.
4. Use only as described in this manual.
5. Do not use with a damaged cord or plug. If the supply
cord and/or plug is damaged, they must be replaced by the manufacturer, a Vax Service Agent or similarly qualified persons in order to avoid hazard.
6. Do not pull or carry by the cord, use the cord as a
handle, allow the cord to come into contact with hot or sharp surfaces or close a door on the cord.
7. Do not unplug by pulling on the cord.
8. Do not handle the plug or carpet washer with wet
hands.
9. Do not put any objects into openings or operate with
openings blocked, keep them free of anything that may reduce airflow.
10. Keep hair, loose clothing, fingers and all parts of the
body away from openings and moving parts.
11. Do not use the carpet washer on any glowing,
burning or smoking particles.
12. Do not use without the solution tank and dirty water
tank in place.
13. Turn off all controls before unplugging.
14. Do not use to pick up flammable or combustible
liquids such as petrol, or use in areas where they may be present.
15. Keep the carpet washer on the floor.
16. Do not use an extension cord.
17. Do not attempt to remove blockages with sharp
objects as they may cause damage.
18. Store indoors put away after use to prevent tripping
accidents.
19. Using improper voltage may result in damage to the
motor and possible injury to the user. The correct voltage is listed on the rating label.
20. A hazard may occur if the carpet washer runs over
the power supply cord.
NOTE: Carpets should be dry vacuumed thoroughly before washing.
NOTE: The unit must be unplugged from the mains socket outlet after use, and before cleaning or maintaining the unit.
IMPORTANT: This unit is not intended for commercial use.
PLEASE KEEP THESE INSTRUCTIONS FOR FURTHER USE.
Hard Floor Cleaning
NOTE: Only use on sealed hard floor surfaces.
Brushes
NOTE: Brushes continue to rotate even in upright position. Please ensure brush selector is set to the off position when cleaning upholstery.
!
V-133 OasisComp User Guide v5.qxd:V-133 Oasis User Guide 8/9/08 14:44 Page 3
www.vax.co.uk
4
assembly
3. Assembly
Attach upper handle
Remove clean solution tank (upper tank) (Fig.3/1).
With cord hook to back of carpet cleaning machine, push upper handle down onto lower handle (Fig.3/2).
Attach hose holder
Position hose holder onto handle by matching tabs on rack with openings on back of handle.
Make sure bolts are through holes (Fig.3/3).
Place nuts in recessed areas on back of hose holder. Hold each nut in place while tightening each bolt securely (from the front of the handle) with a Phillips screwdriver. Only two nuts are needed on this model. The extra nut is not required but has been provided for your convenience (Fig3/4).
When handle sections are completely together, squeeze trigger and depress Clean Surge button on upper handle.You will hear a “snap” when the trigger rod is in place (Fig.3/5).
Attach tool holder
Remove tool and taped screw from holder. Insert projections on holder into slots on back of cleaner. (Fig.3/6).
Slide holder down into place. Insert screw at (A) and tighten with a Phillips screwdriver (Fig.3/7).
Fig.3/1
Fig.3/4
Fig.3/5
Fig.3/2
Cord hook
Fig.3/6
Fig.3/7
Fig.3/8
Fig.3/3
Squeeze trigger
Clean Surge button
V-133 OasisComp User Guide v5.qxd:V-133 Oasis User Guide 8/9/08 14:44 Page 4
5
V
ax Careline 0870 606 1248
assembly
Replace clean solution tank (upper tank) by positioning bottom first.
Press on tank handle to snap top of tank into place (Fig 3/8).
Storing hose
Stretch hose out and identify ends.(Fig.3/9).
Start with converter end of hose. Fit converter over tab near tool holder.
Press converter firmly to snap in place. Press solution tube into clip next to converter as shown (Fig3/10).
Wrap hose around hook on upper handle .
Press hose into clips on upper hose holder (fig3/11).
Wrap hose around lower tool holder and continue until nozzle connector is near upper hose holder.
Clip hose in place (Fig 3/12).
Press cord into cord clip on back of hose holder.
Pull cord tight (Fig 3/13).
Fig.3/7
Fig.3/8
Fig.3/12
Fig.3/13
Fig.3/10
Fig.3/9
Fig.3/11
Nozzle connector
Upper handle
Upper hose holder
Upper hose holder
Convertor end of hose
Trigger
Solution tube
A
Converter
Tool holder
Solution tube
V-133 OasisComp User Guide v5.qxd:V-133 Oasis User Guide 8/9/08 14:44 Page 5
www.vax.co.uk
6
assembly/ operation
Spinscrub hand tool
To store Spinscrub hand tool, open tool door, place nozzle in bracket and fit it securely into position. To remove, reverse this procedure (Fig3/14).
How to reattach tool cover
The tool cover is designed with a break-away feature which allows it to snap free if it is pushed open too far.
To reattach, align hinges of cover with slots on sides of tool storage area. Push cover down to secure in place (Fig3/15).
4. Operation
IMPORTANT: Operate carpet cleaning machine only at voltage specified on data plate on back of cleaner.
On/Off Pedal
Step on pedal A to turn carpet cleaner on. Step on pedal again to turn carpet cleaner off.
Step on pedal B to lower handle to operating position. Handle does not lock into a single position but “floats” to allow convenient operation (Fig.4/1).
To transport
To move your carpet cleaner from room to room put handle in upright and locked position tilt carpetcleaner back on wheels and push forward. (Fig.4/2).
The carpet cleaning machine may also be lifted by placing a hand under the upper clean solution tank handle (Fig.4/3).
Fig.4/1
Fig.4/2
Fig.4/3
Fig.3/14
Fig.3/15
!
A
B
Spinscrub hand tool
Fig.4/5
V-133 OasisComp User Guide v5.qxd:V-133 Oasis User Guide 8/9/08 14:44 Page 6
Loading...
+ 14 hidden pages