Vax Classic V-024U Instruction Manual

www.vax.co.uk
Please read carefully before using this cleaner.
Always fully extend the mains cable before use.
Retain for future reference.
Vax careline
0870 6061248
instruction manual
Vax model number:
V-024U
UL T
RA
SOLUTION
V-024U User Guide v2.qxd:V-024U User Guide 12/3/08 08:47 Page 1
2
parts overview
Fig.1/1
www.vax.co.uk
1. Diagram
V-024U
1 Handle 2 Clean solution reservoir latch 3 Clean solution reservoir 4 Dirty water tank latch 5 Dirty water tank handle 6 Floating brushbar 7 Dirty water tank 8 Dirty water tank lid 9 Power switch
10 Handle screw 11 Power cord 12 Carrying handle 13 Quick cord release 14 Handle release pedal 15 Cord hook 16 Cord clip 17 Solution release trigger 18 Vax Ultra Solution
1
17
9
10
3
13
15
14
5
7
2
1
6
11
12
18
4
8
6
UL T
RA
SOLUTION
V-024U User Guide v2.qxd:V-024U User Guide 12/3/08 08:47 Page 2
3
V
ax Careline 0870 606 1248
safety information
2. Safety Information
FOR HOUSEHOLD USE ONLY.
When using the vacuum cleaner, basic safety precautions should always be observed, including the following:
1. Do not leave the carpet washer unattended when plugged in. Unplug it from socket when not in use.
2. To prevent electric shock do not use outdoors.
3. Nottobe used as a toy. Children should besupervisedto ensure that they do not play with the appliance.
4. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack ofexperience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.
5. Use only as described in this manual.
6. Do not use with a damaged cord or plug. If the supply cord and/or plug is damaged, they must be replaced by the manufacturer, a Vax Service Agent or similarly qualified persons in order to avoid hazard.
7. Do not pull or carry by the cord, use the cord as a handle, allow the cord to come into contact with hot or sharp surfaces or close a door on the cord.
8. Do not unplug by pulling on the cord.
9. Do not handle the plug or carpet washer with wet hands.
10. Do not put any objects into openings or operate with openings blocked, keep them free of anything that may reduce airflow.
11. Keep hair, loose clothing, fingers and all parts of the body away from openings and moving parts.
12. Do not use the carpet washer on any glowing, burning or smoking particles.
13. Do not use without the solution tank and dirty water tank in place.
14. Do not use the vacuum without the dust bag in place.
15. Turn off all controls before unplugging.
16. Do not use to pick up flammable or combustible liquids such as petrol, or use in areas where they may be present.
17. Keep the unit on the floor.
18. Do not use an extension cord.
19. Do not attempt to remove blockages with sharp objects as they may cause damage.
20. Store indoors put away after use to prevent tripping accidents.
21. Using improper voltage may result in damage to the motor and possible injury to the user. The correct voltage is listed on the rating label.
22. A hazard may occur if the carpet washer runs over the power supply cord.
23. To prevent dirty water from running into motor, do not hold the appliance upside-down or lay on its side. Use appliance in normal vacuuming position.
24. Use extra care when cleaning on stairs.
25. Do not carry appliance while motor is running.
NOTE: Carpets should be dry vacuumed thoroughly before washing.
NOTE: The unit must be unplugged from the mains socket outlet after use, and before cleaning or maintaining the unit.
IMPORTANT: This unit is not intended for commercial use.
PLEASE KEEP THESE INSTRUCTIONS FOR FURTHER USE.
!
V-024U User Guide v2.qxd:V-024U User Guide 12/3/08 08:47 Page 3
www.vax.co.uk
4
assembly/ operation
3. Assembly
Putting your cleaner together
Stand the base in the upright position. Assemble the mid section onto the base, taking care not to trap internal mains wire (Fig 3/1).
Insert the three nuts into the recesses located on the left and right sides of the base and into the recess located in the middle of the back of the base.
While holding the nuts in place insert screws through the front of the mid section and tighten (Fig 3/2).
NOTE: Phillips screwdriver required
Slide the upper handle down onto the unit. Insert nut into the recess in the back of the upper handle. While holding the nut in place insert the screw through the front of the upper handle and tighten.
Run the mains wire above the upper cord hook and secure with the cord clip (Fig 3/3).
4. Operation
IMPORTANT: Turn off when emptying and filling the reservoir.
Grasp the solution reservoir under the handle and press the handle release lever upward (Fig 4/1).
Tilt the solution reservoir away from the cleaner and remove (Fig 4/2).
Unscrew the filler/ measure cap from the rear of the solution reservoir (Fig 4/3).
Fill the bottle cap or measure cap 4 times with Vax Ultra Solution and pour into the reservoir (Fig 4/4).
Fig.3/1
Fig.4/1
Fig.4/2
Fig.3/2
Fig.4/3
Fig.4/5
Fig.4/6
Fig.3/3
!
V-024U User Guide v2.qxd:V-024U User Guide 12/3/08 08:47 Page 4
Loading...
+ 8 hidden pages