Page 2
---
Machine Overview
4
3
1
Unit
2
8 Telescopic tube 9 Combination floor head
10 2-in-1 tool:
Dusting brush and crevice tool
11 Flexible hose and handle
12 Fibre pre-motor filter 13 HEPA post motor filter 14 Disposable dust bag (1 fitted, 2 spare)
1 On/off button 2 Auto cord rewind 3 Floor tool parking (not seen) 4 Carry handle 5 Hose inlet
6 Variable power switch 7 Lid release button
Accessories
Filters
9
(
not seen)
2
5
7
6
11
10
8
12 13
14
Dust bag
Vax Careline: (UK) 0844 412 8455
(ROI) 1-800 928 308
C90-EB-B-C User Guide v2 (Q7).qxd:User guide 9/4/10 14:48 Page 2
Page 3
FOR HOUSEHOLD USE ONLY.
Whenusingthe vacuum cleaner,basic safety precautions
should always be observed, including the following:
1. Only use the vacuum cleaner indoors on dry surfaces.
Do not handle the plug or vacuum cleaner with wet
h
ands. Do not use outdoors or on wet surfaces.
2
. Turn off the vacuum cleaner controls before
d
isconnecting or connecting from the mains supply.
3. Always unplug the vacuum cleaner before
connecting or disconnecting the vacuum hose and
a
ccessories.
4. Children should be supervisedto ensurethatthey
do not play with the appliance.
5. This appliance is not intended for use by persons
(including children) with reduced physical, sensory
or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a
person responsible for their safety.
6. Use only as described in this manual. Use only Vax
recommended attachments.
7. Do not use the vacuum cleaner if it has been
dropped, damaged, left outdoors or dropped into
water. Do not use the vacuum cleaner with a
damaged cord or plug. If the supply cord is
damaged, it must be replaced by the manufacturer or
a recommended Service Agent to avoid hazard
and invalidating the guarantee.
8. Do not pull or carry by cord. Do not use the cord
as a handle, close a door on the cord or pull cord
around sharp edges or corners. Do not run the
vacuum cleaner over the cord. Keep the cord away
from heated surfaces.
9. Do not put any objects into openings. Do not use
with any openings blocked and do not restrict air-
flow. Keep all openings free of dust, lint, hair or
anything that might reduce airflow.
10. Keep hair, loose clothing, fingers and all parts of
the body away from openings and moving parts.
11. Do not pick up hot coals, cigarette butts, matches
or any hot, smoking or burning objects.
12. Do not pick up flammable or combustible
materials (lighter fluid, petrol, kerosene etc.) or use
in the presence of explosive liquids or vapours.
13. Do not vacuum up harmful or toxic material
(
chlorine, bleach, ammonia, drain cleaner etc.).
14. Do not vacuum up hard or sharp objects such as
g
lass, nails, screws, coins, etc.
1
5. Do not use without ALL of the filters in place.
16. Take extra care when vacuuming on stairs.
1
7. Keep vacuuming area well lit.
18. Store the vacuum cleaner in a cool, dry area.
19. Turn off the on/off switch before unplugging the
vacuum cleaner
20. Use only CE-approved 13 amp extension cords.
Non-approved cords may overheat. Care should
be taken to arrange the cord so that the cord
cannot be tripped over.
WARNING: Always switch off and unplug the
vacuum cleaner from the electrical outlet before
assembling, opening or emptying the dirt container, or before
connecting/disconnecting the attachments.
CAUTION: The vacuum cleaner is a very powerful
unit. Before plugging the cord into the electrical
outlet, make sure the switch is in the ‘off’ position.
IMPORTANT: If the inlet, hose or telescopic tube
is blocked, switch off the vacuum cleaner and
remove the blockage(s) before re-starting the vacuum
cleaner. See Maintenance: Clearing blockages.
IMPORTANT: Washing filters improves vacuum
performance. Vax recommends that they should
be checked and cleaned periodically (depending on the level
of use). Make sure all filters are completely dry before
inserting back into the vacuum cleaner.
IMPORTANT: The motor is equipped with a thermal
cut-out. If for any reason the unit should overheat, the
thermostat will automatically turn the unit off. Should this
occur, unplug the vacuum cleaner from the electrical outlet
and turn off the switch. Remove dirt container and empty.
Clean filters. Allow the unit to cool for approximately one (1)
hour. To re-start, plug into an electrical outlet and switch back
on.
This vacuum cleaner is intended for household use only and NOT for commercial or industrial use.
PLEASE KEEP INSTRUCTIONS FOR FURTHER USE.
!!!!!
General Safety Information
vax.co.uk
3
C90-EB-B-C User Guide v2 (Q7).qxd:User guide 9/4/10 14:48 Page 3
Page 4
---
Operation
Assembling your vacuum cleaner
Choose the attachments for the job
4
Keep your Vax like new
IMPORTANT: The condition of the filters affects the
performance of your machine. Please check and wash filters periodically (depending on the level of use). For full cleaning instructions, see page 6.
!
IMPORTANT: Do not use the vacuum cleaner without all of the filters in place.
!
NOTE: All accesories can be attached to the telescopic tube or hose handle.
Hard floors
Carpets
Operating the appliance
NOTE: Fully extend
the power cord before each use. A yellow mark on the cord indicates the recommended cord length. Do not exceed the cord length beyond the yellow mark.
Vax Careline: (UK) 0844 412 8455
(ROI) 1-800 928 308
C90-EB-B-C User Guide v2 (Q7).qxd:User guide 9/4/10 14:48 Page 4
Page 5
Operation
Packing away and storage
vax.co.uk
5
NOTE: For
convenience there is a parking slot located at the back of the vacuum cleaner where the floor tool can be attached for storage.
WARNING: Do not pick up unit using front carry handle when floor tool is in rear parking slot.
!
C90-EB-B-C User Guide v2 (Q7).qxd:User guide 9/4/10 14:48 Page 5
Page 6
---
6
Vax Careline: (UK) 0844 412 8455
(ROI) 1-800 928 308
Maintenance (Keep your Vax as good as new)
Cleaning the HEPA post motor filter
24hr
!
IMPORTANT: Water temperature should be at a maximum of 40° C when washing filters
t
a
p
Cleaning the fibre pre-motor filter
24hr
t
a
p
!
IMPORTANT: Water temperature should be at a maximum of 40° C when washing filters.
Removing the dust bag
NOTE: When the
dust bag is full, dispose of it and insert a new bag. Click the bag into place then close the lid.
!
IMPORTANT: A
lways switch off and unplug the vacuum cleaner fromtheelectricaloutlet before removing the dustbag.
C90-EB-B-C User Guide v2 (Q7).qxd:User guide 9/4/10 14:48 Page 6
Page 7
vax.co.uk
7
Clearing blockages
Warning: To reduce the risk of electric shock, the power cord must be disconnected from
the mains supply before performing maintenance/troubleshooting checks. Turn the vacuum cleaner off and unplug from the electrical socket
!
Hose blockages
The flexible hose should be disconnected from the vacuum cleaner. Carefully remove any blockages found and reconnect the hose securely.
Accessory blockages
Remove accessory from the hose/handle tube. Carefully remove the blockage and return to the cleaner.
Maintenance (Keep your Vax as good as new)
C90-EB-B-C User Guide v2 (Q7).qxd:User guide 9/4/10 14:48 Page 7
Page 8
---
FAQs
!
WARNING: to reduce the risk of personal injury, unplug the vacuum cleaner before performing maintenance/troubleshooting checks.
Is there an accessory missing?
Check the ‘Parts Overview’ page in this
guide to make sure the part is definitely included in your unit.
If it is missing, we’re here to help. Simply call us on 0844 412 8455
Why won’t the vacuum cleaner pick up?
The filter may be clogged; refer to
‘Maintenance: Cleaning the filters’ on page 6.
The dust bag may be full or blocked; refer to ‘Maintenance: Removing the dust bag’ on page 6.
Why is dust escaping from the vacuum?
The filter may be clogged; refer to
‘Maintenance: Cleaning the filters’ on page 6.
The filter may not be installed correctly; refer to ‘Maintenance: Cleaning the filters’ on page
6.
The dust bag may be incorectly installed; refer to ‘Maintenance: Removing the dust bag’ on page 6.
What do I do if the unit/an accessory becomes damaged or broken?
We’re here to help. Simply call 0844 412 8455 or visit vax.co.uk
Why won’t the accessories pick up properly?
Hose blockages: remove the flexible hose
from the unit. Carefully remove any blockages found and reconnect hose securely.
Accessory blockages: remove accessory from handle/tube. Carefully remove blockage and re-attach to the vacuum cleaner.
The accessory may be faulty. Simply call us on 0844 412 8455 for assistance.
Why will the vacuum cleaner not run?
It may not be plugged into the electrical
outlet correctly; ensure that the plug is pushed in securely.
The electrical outlet may not be working properly; check the fuse or breaker, or consult an electrician.
The motor thermostat may have tripped; switch off and unplug the vacuum cleaner, and leave for one hour before switching the cleaner back on.
8
Vax Careline: (UK) 0844 412 8455
(ROI) 1-800 928 308
C90-EB-B-C User Guide v2 (Q7).qxd:User guide 9/4/10 14:48 Page 8
Page 9
Other Information
UK Service & Help
Vax Careline:
(UK) 0844 412 8455
(ROI) 1-800 928 308
Monday-Friday 8.30am to 6.30pm
Saturday-Sunday 9.00am to 5.00pm
Any queries or concerns about using your Vax, call the Vax Careline. Please make a note of the serial number and model number of the carpet cleaner before calling.
Consumables
To purchase spares and accessories, please visit vax.co.uk
Bag kit: 1-9-130098-00 Filter kit: 1-9-130099-00
Technical Specification
Voltage: 220-240V ~50Hz Wattage: 1800 W Bag capacity: 2.8L approx Filters: Fibre pre-motor filter (washable)
HEPA post motor filter (washable) Bag: Disposable Cord length: 6 m (approx) Weight: 4.9kg (approx)
Subject to technical change without notice.
EEC Statement of Compliance
Manufacturer/EEC importer: Vax Limited, hereby on our own responsibility, declare that the C90-EB-B-C is manufactured in compliance with the following Directives:
Safety: 2006/95/EC Low Voltage Directive EMC: 2004/108/EC Electromagnetic Compatibility Directive
Waste electricalproducts should not be disposed of withhousehold waste. Please recycle where facilities exist.Check with your Local Authority or retailer for recycling advice.
vax.co.uk
9
C90-EB-B-C User Guide v2 (Q7).qxd:User guide 9/4/10 14:48 Page 9
Page 10
---
Notes
10
Vax Careline: (UK) 0844 412 8455
(ROI) 1-800 928 308
C90-EB-B-C User Guide v2 (Q7).qxd:User guide 9/4/10 14:48 Page 10
Page 11
Notes
vax.co.uk
11
C90-EB-B-C User Guide v2 (Q7).qxd:User guide 9/4/10 14:48 Page 11
Page 12
Vax Ltd., Kingswood Road, Hampton Lovett, Droitwich, Worcestershire, WR9 OQH, UK
email: info@vax.co.uk - website: vax.co.uk
C90-EB-B-C User Guide v2 (Q7).qxd:User guide 9/4/10 14:48 Page 12
Loading...