Vax ACTION 602 U86-AN-BE, ACTION 602 U86-AN-PE, ACTION 602 U86-IN2-PE Get Started

vax.co.uk
U86-AN-Be/U86-AN-Pe/U86-IN2-Pe
Action 602
Let’s get started
Basic safety precautions
Don’ts
it has been dropped, damaged or left outdoors.
8 Don’t run over the power cord or use
vacuum cleaner if the power cord or plug is damaged. Please contact our Customer Care Line on: 0330 026 8455 (Mon-Fri 8.30am to 6.30pm, Sat 9.00am to 5.00pm).
8 Don’t handle the plug or use the
vacuum cleaner with wet hands.
8 Don’t pull or carry this vacuum
cleaner by the power cord. Don’t use the power cord as a handle, pull the power cord around corners, sharp
edges or close a door over the power cord. Don’t unplug vacuum cleaner by pulling on the power cord.
8 Don’t vacuum up any ammable
or combustible materials (lighter uid, petrol, kerosene etc.) or use the vacuum cleaner in an area with explosive vapours or liquid.
8 Don’t vacuum up hot coals, cigarette
butts, matches or smoking hot burning items or use in an area where there may be harmful uids (chlorine, bleach, and ammonia drain cleaner).
Let’s talk safety
This vacuum cleaner is intended for household use only and NOT for commercial or industrial use.
• Only use the vacuum cleaner indoors on dry surfaces and keep the area your cleaning well lit.
• Keep ngers, hair and loose clothing from moving parts and openings whilst using the vacuum cleaner.
• This vacuum cleaner can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental
capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the vacuum cleaner in a safe way and understand the hazards involved. Children shall not play with the vacuum cleaner. Cleaning and user maintenance shall not be made by children without supervision.
• Only Vax recommended tools should be used with this vacuum cleaner.
Please keep instructions for further use.
Do’s
3 Turn o all controls on the vacuum
cleaner before disconnecting or connecting the power cord.
3 Always make sure lters are in place
before use.
3 Always switch o the
vacuum cleaner before disconnecting or connecting the hose and accessories.
3 Keep all openings clear and free
from debris as this may aect the airow/suction.
3 Always replace the fuse in the plug
with a British 13amp fuse. Always protect the power cable from heated surfaces and open ames.
3 Take extra care when positioning
and using the vacuum cleaner on the stairs.
3 Use only CE approved 13amp
extension cords, non-approved extension cords may overheat. Care should be taken to arrange the extension cord as it can be a trip hazard.
3 Store your vacuum cleaner in a cool,
dry area. If lters have been cleaned as per user guide instructions ensure they are thoroughly dry before storing away.
Don’ts
8 Don’t attempt to remove blockages
with sharp objects as this may cause damage to your vacuum cleaner.
8 Don’t vacuum up hard or sharp
objects such as glass, nails, screws or coins etc.
8 Don’t use the vacuum cleaner with
incorrect voltage as this may result in damage or injury to the user. The correct voltage is listed on the ratings label.
Let’s talk safety
Taking care of you
We’re here if you need us. Instead of taking me back to the shop, simply visit:
vax.co.uk/support or call:
(UK) 0330 026 8455 (ROI) 1-800 928 308
Monday-Friday 8.30am to 6.30pm, Saturday 9.00am to 5.00pm
Calls are charged at the UK local rate. Please make a note of the serial number and model number of the product before calling.
Alternatively, you can write to us at:
Vax Ltd., Plot 302, Stonebridge Cross Business Park, Hampton Lovett, Droitwich, Worcestershire, WR9 0LW, UK
This user guide can also be found online at: vax.co.uk/support
Let us know what you think @VaxUK
Thank you for buying this Action 602.
Taking care of your carpets
The Action 602 is designed to make washing carpets regularly, as eective and ecient as possible and this user guide will help you get the most out of your machine.
Maintaining your carpets will ensure they keep their appearance for longer and smell fresh and clean. You’ve chosen the carpets for your home for a reason and Vax will help you take good care of them.
Taking care of your Action 602
Also inside this guide are instructions on maintaining your new machine, so that it’s always ready when you are to tackle your carpets.
Contents
Let’s talk safety
Getting to know your machine
Getting started
Using your machine
Taking care of your machine
Let’s talk technical
What to do if it goes wrong
Getting in touch
Accessories
Notes
Action 602
Included with your machine
Action 602 Pet
+
TurboTool
Reach extension hose 2.2m
Reach extension hose 1.5m
2 in 1 dusting/upholstery & crevice tool
Extension tube
Hard oor tool
Action 602 Reach
+
Initial Setup for normal operation
1. Use the base accessories. a. Shortest hose. b. Extension tube set to shortest practicable length.
2. Clean lters installed.
3. Dust receptacle empty.
4. All Bleeds must be closed.
5. Variable Power set to Maximum.
6. Floor heads/tools set to Carpet Mode for carpet cleaning.
7. Mechanical Agitation turned ON for carpet cleaning.
8. Floor heads/tools set to Hard Floor Mode for hard oor cleaning.
9. Mechanical Agitation turned OFF for hard oor cleaning.
Extension tube and crevice
Handle release button
Dust brush holder (some models only)
Handle
Turbo tool holder (some models only)
Carry handle
Dirt container release button
Separator
Dirt container lid
Dirt container
HEPA pre-motor lter (hidden)
Dirt release clip
Upper release cord hook
Hose to machine connector
Height adjuster dial
Name Action 602 Voltage 220-240V-50Hz Wattage 900 Air Watts Cord length 7m Weight 7.5kg
Technical Specication
Subject to technical change without notice.
Filter Kit (Type 110)
1-1-134394
Belt Kit Type 25
1-1-134411
Turbo Tool Type 6*
1-1-134419
Crevice Tool (Type 16)
1-1-134427
Dusting Brush (Type 10)
1-1-134426
Pro Cleaning kit
(1-1-133326)
Accessories & Consumables
* Selected models only.
To purchase consumables and accessories, please visit vax.co.uk
Hose connector
Hose inlet
On/o button
Getting to know your machine
Assembling your vacuum cleaner
Lift handle up and click into place.
Slide 2 in 1 Dusting Brush onto dust brush holder with brushes facing outwards.
Line up latch on accessory hose, push until clicks into place.
Line up turbo tool brushes into turbo tool holder, push into place until it clicks (some models only).
Push accessory hose into hose to machine connector.
Push extension tube and crevice onto holder.
Before you begin cleaning
IMPORTANT: Always switch o the vacuum cleaner before connecting or disconnecting the hose/attachments or removing and emptying the dirt container.
IMPORTANT: The vacuum cleaner is equipped with a thermal cut-out. If for any reason the vacuum cleaner does
overheat the thermostat will automatically turn the vacuum cleaner o. If this happens switch the vacuum cleaner o and unplug from electrical socket. Remove and empty the dirt container also check the vacuum cleaner for blockages. Allow the vacuum cleaner to cool for approximately 1 hour (if you have cleaned the lters please wait 24 hours for the lters to fully dry before putting back into the machine).
Filters require cleaning at least every 3-6 months. If the vacuum cleaner is blocked, switch o and unplug before removing the blockage.
When the vacuum cleaner is stood in the upright position, or when using the hose and tools the brush bar height adjuster must be set to the highest setting.
PLEASE READ ‘LET’S TALK SAFETY’ AT THE BEGINNING BEFORE USE
Getting started
Plug vacuum cleaner into the mains, switch on. Turn brush bar height adjuster dial to desired setting.
Press On/O button to switch on.
Place foot on oor head and pull handle to recline.
The accessories can be attached to the extension tube or directly to the hose.
When using accessories on the hose/extension tube raise the height adjuster to the highest setting.
Pull hose out of hose to machine connector.
Attach accessory to tube/hose.
Attach accessory hose to extension hose.
If required attach extension hose to extension tube.
Using accessories
Choose an accessory.
Using your machine
IMPORTANT: Always switch o and unplug the vacuum cleaner before connecting or disconnecting the hose/
attachments, or removing and emptying the dirt container.
TIP
For best performance use your vacuum cleaner with only the accessory hose attached.
Hard oor cleaning
Hard oor cleaning tool.
Line up oor tool with base of vacuum cleaner, push it until it clicks into place.
Lie vacuum cleaner on its back exposing brushbar.
Hold vacuum cleaner with brush bar over tread of stairs.
Using on the stairs
Always raise the height of the brush bar to hard oor setting when using the vacuum cleaner on lino and hard oor.
Using your machine
TIP
Filters require cleaning at least every three months.
This vacuum cleaner has a constantly rotating brushbar. When cleaning on stairs raise the height adjuster dial to the highest setting. The brushbar must overhang the stair tread. Always take care when cleaning stairs.
WARNING
Press the dirt container release button, pull to remove.
Emptying the dirt container
Cleaning the HEPA pre-motor lter
Hold dirt container over a bin.
Press the dirt release clip, allowing dirt/debris to fall out.
Turn the dirt container release button, pull to remove.
24hr
Leave to dry for 24 hours or until fully dry before placing back in the vacuum cleaner.
Turn the HEPA pre-motor lter anti-clockwise, pull to remove.
Tap HEPA pre-motor lter over a bin to remove any dirt/debris.
Rinse under water (max 40°C).
Line up HEPA pre-motor lter tabs in dirt container lid, turn clockwise until it clicks into place.
Taking care of your machine
Filters require cleaning at least every 3-6 months (depending on the level of use).
Don’t use your vacuum cleaner without all the lters in place.
IMPORTANT: The motor is equipped with a thermal cut-out. If for any reason the machine should overheat, the thermostat will automatically turn the machine o. Switch o and unplug the vacuum cleaner. Check the machine for blockages and clean the lters. Wash the lters with warm water (40°C max) and leave for 24 hours or until fully dry before replacing into the machine.
TIP
Don’t over ll the dirt container to avoid blocking the air ow through the vacuum cleaner and replace lters every 6-9 months.
Cleaning the post motor lter
Cleaning the separator
Press post motor lter cover clip, pull to remove.
Turn separator anti-clockwise to ‘unlock’, pull to remove.
Remove any dirt/ debris. Rinse under water (max 40°C).
Using a soft brush clean any dirt/debris out of the separator.
Remove post motor lter.
Tap separator over a bin to remove any dirt/debris.
Leave to dry for 24 hours or until fully dry before placing back in the vacuum cleaner.
24hr
Line up tabs on separator with dirt container, turn separator clockwise to ‘lock’ and click into place.
The separator should sit on seal in bottom of dirt container when correctly tted.
Taking care of your machine
Taking care of your machine
Pull hose out of hose to machine connector.
Wrap hose around hose guide. Over and behind carry handle. Into hose to machine connector.
Attach accessory hose to extension hose.
Storing extension hose on vacuum cleaner (optional)
Storing your vacuum cleaner
Wrap the power around the quick cord release hooks.
Press handle release button.
Lower handle downwards.
Always use the carry handle to lift and carry the machine.
Removing dirt/debris from TurboTool (some models only)
Removing debris from the brushbar
Using a pair of scissors cut any hair or debris free from around the brushes.
Line up the tabs on front of the housing and re-t. Slide locking ring into groove to secure.
Slide the locking ring to remove.
Using a pair of scissors remove any threads or hair caught around the brush bar.
Tabs
Lift and separate the housing.
IMPORTANT: Unplug and switch o vacuum cleaner before performing maintenance or troubleshooting checks.
Let’s talk technical
TIP
To test for a blockage in the hose, drop a small ball of paper through the hose. The paper will drop through if the hose is clear.
Replacing the belt
Place belt on rounded area of brush bar without bristles.
Line up right side of brush bar with base, push into place. Lift and push left side of brush bar until clicks into place.
Lie vacuum cleaner on its back exposing brush bars. Use a cross head screwdriver. Undo 5 screws.
Line up brush bar cover, push until it clicks into place. Replace 5 screws and tighten.
Lift to remove brushbar cover.
Lift to remove brush bar. Remove and dispose of old belt.
Clean any debris from spindle. Place new belt on spindle.
Pull hose out of hose to machine connector.
Lift clip under the hose inlet.
Pull latch out and remove hose.
Remove any blockage by inserting wire coat hanger into hose.
Line up latch, push until it clicks into place.
Removing a blockage from the hose
Let’s talk technical
If the brushbar does not rotate easily then the belt may not have been tted correctly. Make sure the belt is not twisted.
WARNING
• Check the ‘This pack contains’ panel on the box to make sure the part is included with your vacuum cleaner.
• The plug may not be fully pushed into the electrical socket.
• Check the fuse in the plug if this needs replacing, always replace with a 13amp fuse.
• The motor thermostat may have tripped. If this has happened, unplug the vacuum cleaner. Remove and empty the dirt container and check the hose for blockages. Clean the lters and allow the vacuum cleaner to cool for approximately 1 hour (if you have washed the lters you will need to wait 24 hours for the lters to fully dry before putting them back into the vacuum cleaner).
• The brushbar may be clogged, check the brush bar and clear any hair or debris. Go to ‘Let’s talk technical’.
• The belt might be broken, go to ‘Let’s talk technical’.
• There may be a blockage in the hose. Please remove the hose from the vacuum cleaner, check and clear any blockages. Go to ‘Let’s talk technical’,
• Empty the dirt container and clean lters. Go to ‘Taking care of your machine’.
• The brushbar may not be turning. Go to ‘My brushbar isn’t turning’ below.
• The brush bar height adjuster dial may not be set to the correct setting. Go to ‘Using your machine’.
• If the accessory/tool will not pick up, check and clear any blockages. Go to ‘Let’s talk technical’.
SolutionProblem
Is there an accessory missing?
Why does my vacuum cleaner have no power?
Why won’t the vacuum cleaner pick up?
My brushbar isn’t turning.
What to do if it goes wrong
Registration required. Terms and conditions apply, see vax.co.uk for details.
* Calls are charged at the UK local rate. Please make a note of the serial number and model number of the product before calling.
Getting in touch
Don’t forget your accessories!
Order at: www.vax.co.uk/spares-and-solutions
TurboTool (Type 6) 1-1-134419
Use the TurboTool for vacuuming your stairs, upholstery and car interiors. It’s great for picking up stubborn pet hair.
Pro cleaning kit (Type 2) 1-1-133326
All our best tools all in one kit that makes cleaning your home quicker, easier and with even better results. We’ve taken care of cleaning all of the hard to reach areas such as on top of cupboards and in between blinds to the dust that collates behind and within the radiator.
Accessories
Notes
Notes
@VaxUK
Vax Ltd., Plot 302, Stonebridge Cross Business Park, Hampton Lovett, Droitwich, Worcestershire, WR9 0LW, UK
EEC Statement of Compliance: Manufacturer/EEC importer: Vax Limited, hereby on our own responsibility, declare that the U86-AN-Be/U86-AN-Pe/U86-IN2-Pe is manufactured in compliance with the following Directives: Safety: 2006/95/EC Low Voltage Directive. EMC: 2004/108/EC Electromagnetic Compatibility Directive.
Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your Local Authority or retailer for recycling advice.
© 2016 Vax Limited. All rights reserved. The VAX trade mark and Vax lozenge is the property of Techtronic Floor Care Technology Ltd and is registered in the EU and may be pending or registered in other countries.
Loading...