1. The Image of Correct Panorama...................................................................................... 33
Vatech. Co., Ltd 5
Neo-TOP Ser i es User Manual
1
Chapter 1. Introduction
This chapter describes general features, structures of product and
precautions in detail
Vatech. Co., Ltd 6
Neo-TOP Ser i es User Manual
1. Features
● Less X-Ray dose for patient safety.
● Easy to use with Control Panel
● Embedded voice command device for a comprehensive direction to patient at any
stage.
●Reliable to solve the problem.
Vatech. Co., Ltd 7
Neo-TOP Ser i es User Manual
2. Packages
Hardware
● Neo-TOP-F Series (including cables)
● User Manual
● Accessories
The specification of hardware is subject to change for upgrading
equipment without notice.
Film Cassette (Option)
● Pano Cassette: 15x30 (cm)
● Ceph Cassette: 20.3x25.4 (cm)
Screen – Kodak Lanex Regular.
Film – Kodak T-MAT G Dental Film, 400-speed system.
Vatech. Co., Ltd 8
Neo-TOP Ser i es User Manual
3. Precautions
Follow instructions as below.
● For safety reason, operate product as this manual.
● Check the conditions of product (Power, Cables) before operating.
● Every operation of product should be done step by step after each
previous step is finished. otherwise, it can cause malfunction.
● According to the instruction of voice guidance, go to the next capture stage after
finishing cooling time to prevent the tube from being overheated.
● Keep away from water, moisture, corrosive material, and chemicals.
● If there is abnormal movement, turn off system and then, contact your agent.
Vatech. Co., Ltd 9
Neo-TOP Ser i es User Manual
Safe Regulation for Radiation Protection
As radiation safety and protection requirements vary from
country to country and state to state, it is responsibility of the
operator to ensure that all local and national radiation safety
and protection requirements are met.
●When the X-ray is exposed, operators should protect themselves from radiation
by using a lead apron or by standing behind a suitable radiation shield.
● When the X-ray is exposed, operators should provide patients with the precaution
to protect from radiation by using a lead apron.
● In case of children or pregnant woman, consult a doctor before X-ray exposure.
● When the X-ray is exposed, operators should stand at least two meters (6feet)
from the X-ray source.
●Operators must observe the patient during the exposure time in case of an
emergency situation.
● When the X-ray is exposed, operators should stop the system if an abnormal
movement occurs.
This product can be exploded under the circumstance of being
explosive material or liquid.
Vatech. Co., Ltd 10
Neo-TOP Ser i es User Manual
The responsibility of manufacturer
The manufacturer and/or agent have the responsibility for the conditions as
below.
● NEO-TOP-F series are installed by specialists who are qualified and trained
by agent.
● NEO-TOP-F series are installed as manual indicated.
● Use parts that are approved by Vatech.
● Maintain and repair service are made by specialists who are qualified
and trained by Vatech and/or its agent.
● NEO-TOP-F series are operated as manual indicated.
Vatech. Co., Ltd 11
Neo-TOP Ser i es User Manual
2
Chapter 2. Structure
This chapter describes structure, functions in detail so that end-user can
make full use of Neo-TOP-F series.
Vatech. Co., Ltd 12
Neo-TOP Ser i es User Manual
1. The Structure of hardware
Ceph Headrest
Touch Screen
Ceph Cassette holder
Pano Cassette holder
● Rotator: Circling during capturing image
● Hand Frame: Patient can grip for proper position
● Tube: Generate X-ray beam
● Pano Cassette holder: Hold Pano cassette
● Touch Screen: Control the system
● Headrest: Maintain patient posture
● Ceph Cassette holder: Hold Ceph cassette
Tube
Rotator
Headrest
Hand Frame
●Ceph headrest: Maintain patient position during image capture for better
image.
This structure can differ from each model
Vatech. Co., Ltd 13
Neo-TOP Ser i es User Manual
2. The Composition of Touch Screen
The followings are brief explanations about the structure of capturing program.
5
6
7
1
2
3
4
8
① Return
● Returning to initial position for capturing image.
② LAMP
● Projection of Vertical / Frankfurt / Canine beam.
③ Pano
● Convert to Panoramic mode.
④ Ceph
● Convert to Cephalometric mode.
9
10
11 12
⑤ Adult Man
● Select patient type for adult man, and set proper X-ray dose.
⑥ Adult Woman
● Select patient type for adult woman, and set proper X-ray dose.
Vatech. Co., Ltd 14