Varytec LED Easy Move Micro Beam User Manual

Manual
LED Easy Move Micro
Beam RGBW
Table of contents
1. Safety instructions ............................................................................................................................ 3
1.1. FOR SAFE AND EFFICIENT OPERATION ............................................................................ 3
2. Designated use ................................................................................................................................ 4
2.1. Overhead installation ............................................................................................................... 5
3. Introduction ....................................................................................................................................... 7
3.1. Product overview ..................................................................................................................... 7
4. Connections ..................................................................................................................................... 8
4.1. Electrical connections .............................................................................................................. 8
4.2. DMX connections .................................................................................................................... 8
4.3. DMX connection with terminator.............................................................................................. 8
5. Control .............................................................................................................................................. 9
5.1. Structure of the menu .............................................................................................................. 9
6. DMX chart ...................................................................................................................................... 11
6.1. DMX mode Standard (13 channels) ...................................................................................... 11
6.2. DMX mode Basic (11 channels) ............................................................................................ 12
7. Technical data ................................................................................................................................ 13
1. Safety instructions
This
device is suitable for indoor use (not outdoors) only.
All modifications to the device will void the warranty.
Repairs are to carry out by skilled personnel
Use only fuses of the same type and original parts as spare parts.
Protect the unit from rain and humidity to avoid fire and electric shocks.
Make sure to unplug the power supply before opening the housing.
1.1.
FOR SAFE AND EFFICIENT OPERATION
Be
careful with heat and extreme temperature
Avoid exposing it to direct rays of the sun or near a heating appliance.
Not put it in a temperature bellow 32
Keep away from humidity, water and dust
Do not place the set in a lo
cation with high humidity or lots of dust.
Containers with water should not be placed on the set.
Keep away from sources of hum and noise
Such as transformer motor, tuner, TV set and amplifier.
To avoid placing on un-
stable location
Select a level and s
table location to avoid vibration.
Do not use chemicals or volatile liquids for cleaning
Use a clean dry cloth to wipe off the dust, or a wet soft cloth for stubborn dirt.
If out of work, contact sales agency immediately
Any troubles arose, remove the
power plug soon, and contact with an engineer for repairing, do not
open the cabinet by yourself, it might result a danger of electric shock.
Take care with the power cable
Never pull the power cable to remove the plug from the receptacle, be sure to hold
using the device for an extended period of time, be sure to disconnect the plug from the receptacle.
Important:
Damages caused by the disregard of this user manual are not subject to warranty. The dealer
will not accept liability fo
r any resulting defects or problems. Make sure the electrical
connection is carried out by qualified personnel. All electrical and mechanical connections
have to be carried out according to the European safety standards.
only.
°F /0°C, or exceeding 104°F /40°C.
the plug. When not
2. Designated use
This device was developed for professional use on stages, in discos, theatres etc. The device is only approved for a connection up to 230V 50/60 Hz AC voltage and only for indoor use. Regular breaks during operation increase the lifetime of your device.
Avoid convulsions or any form of forceful impact during the installation or the start-up of the device.
Make sure that the device is not exposed excessive heat, humidity or dust at the place of installation. Take care that no cables are lying around. You would endanger your own safety and also the safety of a third party.
It is not allowed to operate or store the device in an environment in which spray water, rain, humidity or fog is expected. Humidity or very high atmospheric humidity could reduce the isolation of the device and could cause deathly electric shocks. If you use fog devices the device has not be exposed to a direct smoke jet. There has to be a safety distance of at least 0,5m between this device and the fog machine. Make sure that the saturation of the fog has to enable a visibility of at least 10m.
The ambient temperature has to be between 0°C and +40°C. Avoid direct sunlight and close proximity to heaters. You have also to attend it during the transport in closed motor vehicles.
Operate the device not during thunderstorms. Surge voltages could destroy the device. Unplug the power supply during thunderstorms.
During the installation the use of the mounting bracket is obligatory.
Surrounding objects or surfaces should not be in contact with the device.
Make sure that during the installation and removal of the device the area below the place of installation is basically cordoned off. This also applies to implementation of service.
The device has basically been protected by a suitable safety.
Make familiar yourself with the functions of the device before start-up. People without the experience should not handle with the device. The most cause of functional disorder is inappropriate handling.
Do not use chemicals or volatile liquids for cleaning. Use a clean dry cloth to wipe off the dust, or a wet soft cloth for stubborn dirt.
For transport use the original packing or designated accessory to avoid damages during the transport.
For reasons of safety unauthorized changes are forbidden.
A usage of the device which differs from usages which are described in this manual can cause damages of the device. In that case the warranty expires. Additional you should notice that every differed usage is related with dangers and can cause e.g. an electrical short, fire, electric shock or crash.
2.1.
Overhead installation
Danger of life!
You have to observe the regulations of BGV C1 (formerly VBG 70) and
EN60598-2-
17
The suspension devices have to be build and measured so they can withstand for an hour the tenfold
of the payload without suffering a permanent detrimental deformation.
Basically installation has to be made by using a second separate suspension. This can
suitable net. The second suspension must be designed and attached so no part of the installation can
fall down in case of failure.
During construction, reconstruction and deconstruction unnecessary stay in the range of moving
areas, on lightning
bridges, under elevated work stations or any other danger zones is forbidden.
The operator is obliged to following safety
- Before the first start-
up or after critical changes before restarting it has to be checked by
expert.
-
Review in the frame of the inspection test at least all four years by an expert. .
-
Review by a qualified person at least once a year.
How to carry out the overhead installation:
In tidal fall you should install the device out of the lounge
IMPORTANT!
Overhead installation requires a high level of experience. This includes knowledge of
calculating the payload, used installation material and safety inspections of the used material and the
projector whereas the required experien
yourself under any circumstances if you are not qualified. Contact a professional installer. An
inappropriate installation can lead to injuries and/or damaged properties.
It is not allowed t
o install the device in the grip area of people.
If the device may hang from the ceiling or from high beams, the use of truss systems is mandatory.
The device may not be installed so it can swing freely in the room.
Please note: Crashing down items can
the safety of a possible installation form!
Before installation make sure that the mounting surface has the ability to carry the tenfold point load of
the own weight of the device.
Mount
the device with the mounting
During overhead installation the device must be always secured by a safety rope which is designed to
hold the twelvefold weight of device. Only safety ropes with qui
may be used. Hang up the safety rope in the hole of the mounting bracket. Direct the rope over the
truss or an appropriate fastening point. Hang up the end in the fastening element and tie up the
locking nut. A safety ro
pe once exposed to failing load or damaged may not be used furthermore.
Installations are to carry out by skilled personnel only.
-related and mechanical facilities:
area of people
ce is not limited to this. Do not try to carry out installation
cause serious injuries! Do not install the projector, if you doubt
-
bracket to your trussing system using an appropriate clamp.
ck-
release safety fastener elements
be e.g. a
an
The maximum drop exceed must not exceed 20cm.
A safety rope once exposed to failing load or damaged may not be used furthermore. Adjust the desired inclination angle via the mounting bracket and tighten the screw.
3. Introduction
Thank you for buying the LED Easy Move Micro Beam. . It is a powerful device.
For a successful installation and operation, please read this manual carefully.
3.1. Product overview
1. Display 6. Power in P-Con
2. Menu 7. Power out P-Con
3. Up 8. DMX out XLR 3pol
4. Down 9. DMX in XLR 3 pol
5. Enter 10. Fuse
4. Connections
4.1. Electrical connections
If you wish to change the power supply settings, see the chapter Appendix. Connect the fixture to the mains with the enclosed power cable and plug. The earth has to be connected.
Cable (EU)
Cable (US)
Pin International
Brown Black Live L Light blue White Neutral N Yellow/Green Green Earth
4.2. DMX connections
To make a DMX512 connection go ahead like it is described in the picture. Make sure that you use shielded cable. 3pole or 5pole XLR cables are suitable. Important! After the last device the line has to be terminated. In order to do this you have to solder a 120 resistor between the pins Data + and Data -. You can solder this end resistor on a 3pin or 5pin XLR: Plug this adapter into the DMX output of the device.
4.3. DMX connection with terminator
Where the DMX cable has to run a long distance or the equipment is operated in an electrically noisy environment like a disco for installations, we recommend using a DMX terminator. This prevents corruption of the digital control signal by electrical noise. The DMX terminator is simply an XLR connector with a 120 resistor between pins 2 and 3, which is then plugged into the XLR output socket of the last device in the series. Please look to the bottom drawings.
5. Control
Press MENU to reach the first menu and use UP/DOWN to get to submenu. To open submenu you have to press ENTER, here you can also reach other menu items with UP/DOWN buttons, confirm with ENTER. Press MENU to store your settings.
5.1. Structure of the menu
Menu
Submenu 1
Submenu 2
Function
AddreSet
ADD:000­512
Setting the DMX address.
MotorSet
TiltRev Yes/No Activate or deactivate the Tilt reverse. PanAdj 000-255 Fine adjusting of Pan. TiltAdj 000-255 Fine adjusting of Tilt. Encoder Yes/No Activate or deactivate the feedback. PanMode 540/630 Choose the required Pan mode.
PanRev Yes/No Activate or deactivate the Pan reverse. AutoProg Alone/Master Chossing an automatic mode. Mic Cont Alone/Master Choosing a sound-to-light mode. MICSensy 000-100% Setting the microphone sensitivity.
ChanTest
Pan 000-255 Manual setting of pan.
Pan1 000-255 Manual setting of Pan fine.
Tilt 000-255 Manual setting of Tilt.
Tilt1 000-255 Manual setting of Tilt fine.
Speed 000-255 Manual setting of the speed.
R 000-255 Manual setting of dimmer red.
G 000-255 Manual setting of dimmer green.
B 000-255 Manual setting of dimmer blue.
W 000-255 Manual setting of dimmer white.
Stro 000-255 Manual setting of the strobe.
Lumi 000-255 Manual setting of the Dimmer
Colo 000-255 9 different color macros.
SavScene Store the setting as scene.
NoSigSet
Auto Choosing the automatic mode.
Music Choosing the sound-to-light mode.
Close No mode is chosen.
Scene Choosing the stored scene.
Mode Set
Basic
Choosing the required DMX mode. User
Standard
UserMode
Pan 00-08 Manual assignment of the DMX channel for Pan.
Pan1 00-08
Manual assignment of the DMX channel for Pan
fine. Tilt 00-08 Manual assignment of the DMX channel for Tilt. Tilt1 00-08 Manual assignment of the DMX channel for Tilt fine. Spee 00-08 Manual assignment of the DMX channel for speed.
R 01-13
Manual assignment of the DMX channel for dimmer
red. G 01-13
Manual assignment of the DMX channel for dimmer
green. B 01-13
Manual assignment of the DMX channel for dimmer
blue. W 00-08
Manual assignment of the DMX channel for dimmer
white.
10 / 16
Stro 00-08
Manual assignment of the DMX channel for the
strobe. Lumi 01-13
Manual assignment of the DMX channel for the
dimmer. Colo 01-13
Manual assignment of the DMX channel for color
macros. Autu 00-08
Manual assignment of the DMX channel for
automatic mode. Save Set Store the manual assignments.
ResetDef Reset. Versions Shows the current software version.
11 / 16
6. DMX chart
6.1. DMX mode Standard (13 channels)
Channel
Value from
Value to
Function
1 0 255 Pan 2 0 255 Pan fine 3 0 255 Tilt 4 0 255 Tilt fine
5
0 225 Speed Pan/Tilt fast-slow 226 235 No function 236 255 Highest speed
6 0 255 Dimmer red 7 0 255 Dimmer green 8 0 255 Dimmer blue 9 0 255 Dimmer white
10
Strobe 0 16 No function 17 255 Strobe
11 0 255 Dimmer
12
Color macros 0 75 No function 76 95 Red 96 115 Green 116 135 Blue 136 155 White 156 175 Red / blue 176 195 Red /Green 196 215 Red / blue 216 235 Blue / green 235 255 Red / green
13
0 75 No function 76 255 Automatic programs
12 / 16
6.2. DMX mode Basic (11 channels)
Channel
Value from
Value to
Function
1 0 255 Pan 2 0 255 Tilt
3
0 225 Speed Pan / Tilt fast-slow 226 235 No function 236 255 Highest speed
4 0 255 Dimmer red 5 0 255 Dimmer green 6 0 255 Dimmer blue 7 0 255 Dimmer white
8
Strobe 0 16 No function 17 255 Strobe
9 0 255 Dimmer
10
Color macros 0 75 No function 76 95 Red 96 115 Green 116 135 Blue 136 155 White 156 175 Red / blue 176 195 Red / green 196 215 Red / blue 216 235 Blue / green 235 255 Red / Green
11
0 75 No function 76 255 Automatic programs
13 / 16
7. Technical data
Power supply
Voltage AC 100-240 V; 50/60 Hz Power consumption max. 35 W
Light source
LM type 4in1 Osram LED Color spectrum RGBW Power 15 W Number / Power 1 x 15 W
Connections
Strom in P-Con Strom out P-Con XLR in/out 3pol Pan 540 / 630 Tilt 180
Controlling
Sound-to-light Yes Automatic Yes Master-Slave Yes DMX512 Yes Number of canals 11 / 13 channels
Hardware
Protection class IP20 Suitability Indoor Dimensions (L/B/H) 164 x 124 x 288 mm Weight 2,64 kg
14 / 16
15 / 16
16 / 16
Importer:
B & K Braun GmbH
Industriestraße 2
D-76307 Karlsbad
www.bkbraun.com
info@bkbraun.com
Loading...