Varytec BAT.PAR 6 RGBWA, BAT.PAR 6 RGBUV User Manual

Page 1
BAT.PAR 6 RGBWA
BAT.PAR 6 RGBUV
LED spotlight
User manual
Page 2
Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de
29.12.2017, ID: 385435, 385475
Page 3
Table of contents
1 General information................................................................................................................................. 6
1.1 Further information........................................................................................................................... 7
1.2 Notational conventions.................................................................................................................... 8
1.3 Symbols and signal words............................................................................................................... 8
2 Safety instructions.................................................................................................................................. 11
3 Features....................................................................................................................................................... 18
4 Installation.................................................................................................................................................. 19
5 Starting up.................................................................................................................................................. 23
6 Connections and operating elements........................................................................................... 25
7 Operating.................................................................................................................................................... 31
7.1 Starting the device........................................................................................................................... 31
7.2 Operating controls on the unit................................................................................................... 31
7.3 Operating via IR remote control................................................................................................. 35
7.4 Menu overview................................................................................................................................. 36
7.5 Functions in 1-channel DMX mode........................................................................................... 38
Table of contents
BAT.PAR 6 RGBWA BAT.PAR 6 RGBUV
3
LED spotlight
Page 4
7.6 Functions in 4-channel DMX mode........................................................................................... 38
7.7 Functions in 5-channel DMX mode........................................................................................... 39
7.8 Functions in 6-channel DMX mode........................................................................................... 40
7.9 Functions in 7-channel DMX mode........................................................................................... 41
7.10 Functions in 8-channel DMX mode........................................................................................ 44
8 Technical specifications....................................................................................................................... 47
9 Plug and connection assignments.................................................................................................. 50
10 Troubleshooting...................................................................................................................................... 51
11 Cleaning....................................................................................................................................................... 53
12 Protecting the environment.............................................................................................................. 54
Table of contents
4
BAT.PAR 6 RGBWA BAT.PAR 6 RGBUV LED spotlight
Page 5
BAT.PAR 6 RGBWA BAT.PAR 6 RGBUV
5
LED spotlight
Page 6
1 General information
This manual contains important instructions for the safe operation of the unit. Read and follow the safety instructions and all other instructions. Keep the manual for future reference. Make sure that it is available to all those using the device. If you sell the unit please make sure that the buyer also receives this manual.
Our products are subject to a process of continuous development. Thus, they are subject to change.
General information
6
BAT.PAR 6 RGBWA BAT.PAR 6 RGBUV LED spotlight
Page 7
1.1 Further information
On our website (www.thomann.de) you will find lots of further information and details on the following points:
Download This manual is also available as PDF file for you to download.
Keyword search
Use the search function in the electronic version to find the topics of interest for you quickly.
Online guides
Our online guides provide detailed information on technical basics and terms.
Personal consultation For personal consultation please contact our technical hotline.
Service
If you have any problems with the device the customer service will gladly assist you.
General information
BAT.PAR 6 RGBWA BAT.PAR 6 RGBUV
7
LED spotlight
Page 8
1.2 Notational conventions
This manual uses the following notational conventions:
The letterings for connectors and controls are marked by square brackets and italics.
Examples: [VOLUME] control, [Mono] button.
1.3 Symbols and signal words
In this section you will find an overview of the meaning of symbols and signal words that are used in this manual.
Letterings
General information
8
BAT.PAR 6 RGBWA BAT.PAR 6 RGBUV LED spotlight
Page 9
Signal word Meaning DANGER! This combination of symbol and signal word indicates an
immediate dangerous situation that will result in death or serious injury if it is not avoided.
WARNING! This combination of symbol and signal word indicates a pos-
sible dangerous situation that can result in death or serious injury if it is not avoided.
NOTICE! This combination of symbol and signal word indicates a pos-
sible dangerous situation that can result in material and environmental damage if it is not avoided.
Warning signs Type of danger
Warning – high-voltage.
Warning – suspended load.
General information
BAT.PAR 6 RGBWA BAT.PAR 6 RGBUV
9
LED spotlight
Page 10
Warning signs Type of danger
Warning – danger zone.
General information
10
BAT.PAR 6 RGBWA BAT.PAR 6 RGBUV LED spotlight
Page 11
2 Safety instructions
This device is intended to be used as an electronic illumination effect using LED technics. The device is designed for professional use and is not suitable for use in households. Use the device only as described in this user manual. Any other use or use under other operating con­ditions is considered to be improper and may result in personal injury or property damage. No liability will be assumed for damages resulting from improper use.
This device may be used only by persons with sufficient physical, sensorial, and intellectual abilities and having corresponding knowledge and experience. Other persons may use this device only if they are supervised or instructed by a person who is responsible for their safety.
Intended use
Safety instructions
BAT.PAR 6 RGBWA BAT.PAR 6 RGBUV
11
LED spotlight
Page 12
DANGER! Danger for children
Ensure that plastic bags, packaging, etc. are disposed of properly and are not within reach of babies and young children. Choking hazard!
Ensure that children do not detach any small parts (e.g. knobs or the like) from the unit. They could swallow the pieces and choke!
Never let children unattended use electrical devices.
DANGER! Electric shock caused by high voltages inside
Within the device there are areas where high voltages may be present. Never remove any covers.
There are no user-serviceable parts inside. Do not use the device if covers, protectors or optical components are missing or
damaged.
Safety
Safety instructions
12
BAT.PAR 6 RGBWA BAT.PAR 6 RGBUV LED spotlight
Page 13
DANGER! Electric shock caused by short-circuit
Always use proper ready-made insulated mains cabling (power cord) with a pro­tective contact plug. Do not modify the mains cable or the plug. Failure to do so could result in electric shock/death or fire. If in doubt, seek advice from a regis­tered electrician.
WARNING! Eye damage caused by high light intensity
Never look directly into the light source.
WARNING! Risk of epileptic shock
Strobe lighting can trigger seizures in photosensitive epilepsy. Sensitive persons should avoid looking at strobe lights.
Safety instructions
BAT.PAR 6 RGBWA BAT.PAR 6 RGBUV
13
LED spotlight
Page 14
WARNING! Incorrect handling of lithium batteries can result in injury
In the event of a short circuit, overheating or mechanical damage, lithium bat­teries can cause severe injuries.
Follow the advice on the correct handling of lithium batteries in the present sec­tion.
NOTICE! Risk of fire
Do not block areas of ventilation. Do not install the device near any direct heat source. Keep the device away from naked flames.
Safety instructions
14
BAT.PAR 6 RGBWA BAT.PAR 6 RGBUV LED spotlight
Page 15
NOTICE! Operating conditions
This device has been designed for indoor use only. To prevent damage, never expose the device to any liquid or moisture. Avoid direct sunlight, heavy dirt, and strong vibrations.
NOTICE! Power supply
Before connecting the device, ensure that the input voltage (AC outlet) matches the voltage rating of the device and that the AC outlet is protected by a residual current circuit breaker. Failure to do so could result in damage to the device and possibly injure the user.
Unplug the device before electrical storms occur and when it is unused for long periods of time to reduce the risk of electric shock or fire.
Safety instructions
BAT.PAR 6 RGBWA BAT.PAR 6 RGBUV
15
LED spotlight
Page 16
NOTICE! Risk of fire due to incorrect polarity
Incorrectly inserted batteries may destroy the device or the batteries. Ensure that proper polarity is observed when inserting batteries.
NOTICE! Possible damage by leaking batteries
Leaking batteries can cause permanent damage to the device. Take batteries out of the device if it is not going to be used for a longer period.
Safety instructions
16
BAT.PAR 6 RGBWA BAT.PAR 6 RGBUV LED spotlight
Page 17
NOTICE! Possible staining
The plasticiser contained in the rubber feet of this product may possibly react with the coating of your parquet, linoleum, laminate or PVC floor and after some time cause permanent dark stains.
In case of doubt, do not put the rubber feet directly on the floor, but use felt-pad floor protectors or a carpet.
NOTICE! Possible damage due to incorrect storage
Deep discharge can cause batteries to become permanently damaged or lose some of their capacity.
Before prolonged rest periods, charge the batteries to around 50 % of their capacity and then switch the equipment off. Store the equipment at a tempera­ture between 10 °C and 32 °C in as dry an environment as possible. During extended storage periods, charge the batteries to 50 % approximately every three months.
Safety instructions
BAT.PAR 6 RGBWA BAT.PAR 6 RGBUV
17
LED spotlight
Page 18
3 Features
Special features of the device:
n
Model BAT.PAR 6 RGBWA: six RGBWA LEDs (red, green, blue, white, amber, 8 W each)
n
Model BAT.PAR 6 RGBUV: six RGBUV LEDs (red, green, blue, UV, 8 W each)
n
Stand-alone, master-slave or DMX mode operation
n
Control via DMX, four different modes, with the supplied infrared remote control or the buttons and display on the unit
n
Stand-alone operation with static colours
n
Sound control
n
Battery or mains powered
n
Power supply and infrared remote control included
n
Suitable for use in clubs, bars, theatres, exhibitions, etc. or for mobile use
Features
18
BAT.PAR 6 RGBWA BAT.PAR 6 RGBUV LED spotlight
Page 19
4 Installation
Unpack and carefully check that there is no transportation damage before using the unit. Keep the equipment packaging. To fully protect the device against vibration, dust and moisture during transportation or storage use the original packaging or your own packaging material suitable for transport or storage, respectively.
WARNING! Risk of injury caused by falling objects
Make sure that the installation complies with the standards and rules that apply in your country. Always secure the device with a secondary safety attachment, such as a safety cable or a safety chain.
Installation
BAT.PAR 6 RGBWA BAT.PAR 6 RGBUV
19
LED spotlight
Page 20
NOTICE! Risk of overheating
Always ensure sufficient ventilation. The ambient temperature must always be below 40 °C (104 °F).
NOTICE! Use of stands
When mounting the device onto a stand, ensure that the stand is in a safe and stable position and that the weight of the device does not exceed the maximum permissible load capacity of the stand.
Installation
20
BAT.PAR 6 RGBWA BAT.PAR 6 RGBUV LED spotlight
Page 21
NOTICE! Possible data transmission errors
For error-free operation make use of dedicated DMX cables and do not use ordi­nary microphone cables.
Never connect the DMX input or output to audio devices such as mixers or ampli­fiers.
You can install the unit in hanging or standing position. When in use, the device must always be attached to a solid surface or an approved truss. Use the openings provided on the two­piece bracket for attaching.
Always work from a stable platform whenever installing, moving or servicing the unit. In doing so, the area underneath the unit must be cordoned off.
The safety-rope must be attached to the bracket.
Mounting options
Installation
BAT.PAR 6 RGBWA BAT.PAR 6 RGBUV
21
LED spotlight
Page 22
Please note that this device must not be connected to a dimmer.
Installation
22
BAT.PAR 6 RGBWA BAT.PAR 6 RGBUV LED spotlight
Page 23
5 Starting up
Create all connections while the device is off. Use the shortest possible high-quality cables for all connections. Take care when running the cables to prevent tripping hazards.
Starting up
BAT.PAR 6 RGBWA BAT.PAR 6 RGBUV
23
LED spotlight
Page 24
Connect the DMX input of the device to the DMX output of a DMX controller or another DMX device. Connect the output of the first DMX device to the input of the second one, and so on to form a daisy chain. Always ensure that the output of the last DMX device in the daisy chain is terminated with a resistor (110 Ω, ¼ W).
Connections in DMX mode
Starting up
24
BAT.PAR 6 RGBWA BAT.PAR 6 RGBUV LED spotlight
Page 25
6 Connections and operating elements
Connections and operating elements
BAT.PAR 6 RGBWA BAT.PAR 6 RGBUV
25
LED spotlight
Page 26
1 Display and function buttons:
[MENU]
Activates the main menu and toggles between menu items. Closes an opened submenu. [UP], [DOWN]
Toggles between the menu items of a menu level, increases or decreases the displayed value by one.
[ENTER]
Selects an option of the respective operating mode, confirms the set value. 2 Locking screws for the mounting bracket. 3 Bracket for floor placement or hanging. 4 [POWER]
Connection socket for the 15 V power supply unit. 5 Battery compartment
Connections and operating elements
26
BAT.PAR 6 RGBWA BAT.PAR 6 RGBUV LED spotlight
Page 27
6 [SWITCH]
Main switch. Turns the device on and off. 7 [BATTERY INDICATOR]
Remaining battery capacity display. When all the LEDs are on, the battery is fully charged. If only the red LED is on,
the unit must be connected to the mains again to charge as soon as possible. 8 [DMX IN]
DMX input. 9 [DMX OUT]
DMX output.
Connections and operating elements
BAT.PAR 6 RGBWA BAT.PAR 6 RGBUV
27
LED spotlight
Page 28
Remote control
Connections and operating elements
28
BAT.PAR 6 RGBWA BAT.PAR 6 RGBUV LED spotlight
Page 29
10 Button to turn the device on and off. 11 [DMX]
Button to switch between DMX and stand-alone mode.
12 [SLAVE]
Button to switch between Master and Slave mode.
13 [AUTO 1], [AUTO 2], [SPEED]
Buttons to activate automatic mode 1 or 2 and to adjust the program's speed.
14 [UP], [DOWN]
Buttons to switch between individual programs and to increase/decrease numeric values.
15 Buttons for colour selection.
Use
n
[W] for white light.
n
[R], [G], or [B] for primary colours red, green and blue.
Connections and operating elements
BAT.PAR 6 RGBWA BAT.PAR 6 RGBUV
29
LED spotlight
Page 30
16 [STROBE]
Button to turn the strobe effect on/off.
17 Numerical buttons 0 … 9 for direct number entry. 18 [SOUND 1], [SOUND 2]
Buttons to activate automatic mode 1 or 2 of the sound control.
Connections and operating elements
30
BAT.PAR 6 RGBWA BAT.PAR 6 RGBUV LED spotlight
Page 31
7 Operating
7.1 Starting the device
Using the main switch, turn the device on. After a few seconds, the fan starts. The display shows the current operation mode.
7.2 Operating controls on the unit
Press [MENU], [UP] or [DOWN] repeatedly until the display shows ‘Addr’ . Confirm with [ENTER]. Now you can set the number of the first DMX channel to be used by the device (DMX address).
Use [UP] and [DOWN] to select a value between 1 and 512 (display shows ‘A001’ ‘A512’). Confirm with [ENTER].
Make sure that this number matches the configuration of your DMX controller.
Press [MENU], [UP] or [DOWN] repeatedly until the display shows ‘Soun’ . Confirm with [ENTER].
DMX address
Sound control
Operating
BAT.PAR 6 RGBWA BAT.PAR 6 RGBUV
31
LED spotlight
Page 32
Use [UP] and [DOWN] to select the desired mode ‘Sou1’ or ‘Sou2’. Confirm with [ENTER]. Now you can adjust the sensitivity of the built-in microphone for sound control. Use [Up] and
[Down] to select a value between 0 (low sensitivity) and 9 (high sensitivity), display shows
‘Se0’ ‘Se9’.
Press [MENU], [UP] or [DOWN] repeatedly until the display shows ‘Stat’ . Confirm with [ENTER]. Use [UP] and [DOWN] to select the fixed colour for which the dimmer setting should be
adjusted:
n BAT.PAR 6 RGBWA (item no. 385435): Red, green, blue, white, amber n
BAT.PAR 6 RGBUV (item no. 385457): Red, green, blue, UV, speed strobe effect
Adjust the setting as desired in a range from 0 … 255 (0 % to 100 %) and confirm with [ENTER] to switch to the next colour in the menu.
Press [MENU], [UP] or [DOWN] repeatedly until the display shows ‘Colo’ . Confirm with [ENTER]. Use [UP] and [DOWN] to select a constant colour in a range from ‘Col1’ ‘Col51’. Confirm
with [ENTER]
Dimmer settings
Constant colour
Operating
32
BAT.PAR 6 RGBWA BAT.PAR 6 RGBUV LED spotlight
Page 33
Press [MENU], [UP] or [DOWN] repeatedly until the display shows ‘Auto’ . Confirm with [ENTER]. Use [UP] and [DOWN] to select the desired mode ‘Aut1’ , ‘Aut2’ or ‘Aut3’. Confirm with [ENTER].
You can now set the program's speed between ‘SP 1’ and ‘SP 9’.
Press [MENU], [UP] or [DOWN] repeatedly until the display shows ‘Info’ . Confirm with [ENTER]. The display shows the current software version.
Use [UP] and [DOWN] to select the option ‘tenP’ . Confirm with [ENTER]. The display shows the current temperature of the device.
or Use [UP] and [DOWN] to select the option ‘uer’ . Confirm with [ENTER]. The display shows the
current software version.
Press [MENU], [UP] or [DOWN] repeatedly until the display shows ‘SLav’ . Confirm with [ENTER]. The display shows ‘Sla’ , the unit is now in Slave mode.
Press [MENU], [UP] or [DOWN] repeatedly until the display shows ‘Chnd’ . Confirm with [ENTER]. Now use [UP] or [DOWN] to select one of the following DMX operating modes:
Operating mode Auto
Device info
Operating mode Slave
DMX mode, BAT.PAR 6 RGBWA (item no. 385435)
Operating
BAT.PAR 6 RGBWA BAT.PAR 6 RGBUV
33
LED spotlight
Page 34
n ‘1Ch’ (one channel) n
‘5Ch’ (five channels)
n
‘7Ch’ (seven channels)
n
‘8Ch’ (eight channels)
Confirm by pressing [ENTER].
Press [MENU], [UP] or [DOWN] repeatedly until the display shows ‘Chnd’ . Confirm with [ENTER]. Now use [UP] or [DOWN] to select one of the following DMX operating modes:
n ‘1Ch’ (one channel) n
‘4Ch’ (four channels)
n
‘6Ch’ (six channels)
n
‘7Ch’ (seven channels)
Confirm by pressing [ENTER].
DMX mode, BAT.PAR 6 RGBUV (item no. 385457)
Operating
34
BAT.PAR 6 RGBWA BAT.PAR 6 RGBUV LED spotlight
Page 35
7.3 Operating via IR remote control
Press [MENU], [UP] or [DOWN] repeatedly until the display shows ‘reno’ . Confirm with [ENTER]. Use [UP] and [DOWN] to select the option ‘on’ to operate the unit via the IR remote control.
Confirm with [ENTER].
Operating
BAT.PAR 6 RGBWA BAT.PAR 6 RGBUV
35
LED spotlight
Page 36
7.4 Menu overview
BAT.PAR 6 RGBWA (item no.
385435)
Operating
36
BAT.PAR 6 RGBWA BAT.PAR 6 RGBUV LED spotlight
Page 37
BAT.PAR 6 RGBUV (item no.
385457)
Operating
BAT.PAR 6 RGBWA BAT.PAR 6 RGBUV
37
LED spotlight
Page 38
7.5 Functions in 1-channel DMX mode
Channel Value Function
1 0…255 Select colour macros 1 … 51
7.6 Functions in 4-channel DMX mode
Channel Value Function
1 0…255 Intensity red (0 % to 100 %) 2 0…255 Intensity green (0 % to 100 %) 3 0…255 Intensity blue (0 % to 100 %) 4 0…255 Intensity UV light (0 % to 100 %)
BAT.PAR 6 RGBUV (item no.
385457)
Operating
38
BAT.PAR 6 RGBWA BAT.PAR 6 RGBUV LED spotlight
Page 39
7.7 Functions in 5-channel DMX mode
Channel Value Function
1 0…255 Intensity red (0 % to 100 %) 2 0…255 Intensity green (0 % to 100 %) 3 0…255 Intensity blue (0 % to 100 %) 4 0…255 Intensity white (0 % to 100 %) 5 0…255 Intensity amber (0 % to 100 %)
BAT.PAR 6 RGBWA (item no.
385435)
Operating
BAT.PAR 6 RGBWA BAT.PAR 6 RGBUV
39
LED spotlight
Page 40
7.8 Functions in 6-channel DMX mode
Channel Value Function
1 0…255 Master Dimmer (0 % to 100 %) 2 0…255 Intensity red (0 % to 100 %) 3 0…255 Intensity green (0 % to 100 %) 4 0…255 Intensity blue (0 % to 100 %) 5 0…255 Intensity UV light (0 % to 100 %) 6 0…255 Stroboscope effect (0 % to 100 %)
BAT.PAR 6 RGBUV (item no.
385457)
Operating
40
BAT.PAR 6 RGBWA BAT.PAR 6 RGBUV LED spotlight
Page 41
7.9 Functions in 7-channel DMX mode
Channel Value Function
1 0…255 Master Dimmer (0 % to 100 %) 2 0…255 Intensity red (0 % to 100 %) 3 0…255 Intensity green (0 % to 100 %) 4 0…255 Intensity blue (0 % to 100 %) 5 0…255 Intensity white (0 % to 100 %) 6 0…255 Intensity amber (0 % to 100 %) 7 0…255 Stroboscope effect (0 % to 100 %)
BAT.PAR 6 RGBWA (item no.
385435)
Operating
BAT.PAR 6 RGBWA BAT.PAR 6 RGBUV
41
LED spotlight
Page 42
Channel Value Function
1 0…255 Master Dimmer (0 % to 100 %) 2 0…255 Intensity red (0 % to 100 %) 3 0…255 Intensity green (0 % to 100 %) 4 0…255 Intensity blue (0 % to 100 %) 5 0…255 Intensity UV light (0 % to 100 %) 6 0…15 No function
16…31 Programme 1 32…47 Programme 2 48…63 Programme 3 64…79 Programme 4 80…95 Programme 5
BAT.PAR 6 RGBUV (item no.
385457)
Operating
42
BAT.PAR 6 RGBWA BAT.PAR 6 RGBUV LED spotlight
Page 43
Channel Value Function
96…111 Programme 6 112…127 Programme 7 128…143 Programme 8 144…159 Programme 9 160…175 Programme 10 176…191 Programme 11 192…207 Programme 12 208…223 Programme 13 224…239 Sound mode 1 240…255 Sound mode 2
7 0…255 Stroboscope effect (0 % to 100 %), if channel 6 = 0…15
Program speed, if channel 6 = 16…223 Microphone sensitivity, if channel 6 = 224…255
Operating
BAT.PAR 6 RGBWA BAT.PAR 6 RGBUV
43
LED spotlight
Page 44
7.10 Functions in 8-channel DMX mode
Channel Value Function
1 0…255 Master Dimmer (0 % to 100 %) 2 0…255 Intensity red (0 % to 100 %) 3 0…255 Intensity green (0 % to 100 %) 4 0…255 Intensity blue (0 % to 100 %) 5 0…255 Intensity white (0 % to 100 %) 6 0…255 Intensity amber (0 % to 100 %) 7 0…15 No function
16…31 Programme 1 32…47 Programme 2 48…63 Programme 3
BAT.PAR 6 RGBWA (item no.
385435)
Operating
44
BAT.PAR 6 RGBWA BAT.PAR 6 RGBUV LED spotlight
Page 45
Channel Value Function
64…79 Programme 4 80…95 Programme 5 96…111 Programme 6 112…127 Programme 7 128…143 Programme 8 144…159 Programme 9 160…175 Programme 10 176…191 Programme 11 192…207 Programme 12 208…223 Programme 13 224…239 Sound mode 1 240…255 Sound mode 2
8 0…255 Stroboscope effect (0 % to 100 %), if channel 6 = 0…15
Operating
BAT.PAR 6 RGBWA BAT.PAR 6 RGBUV
45
LED spotlight
Page 46
Channel Value Function
Program speed, if channel 6 = 16…223 Microphone sensitivity, if channel 6 = 224…255
Operating
46
BAT.PAR 6 RGBWA BAT.PAR 6 RGBUV LED spotlight
Page 47
8 Technical specifications
Technical specifications
BAT.PAR 6 RGBWA BAT.PAR 6 RGBUV
47
LED spotlight
Page 48
BAT.PAR 6 RGBWA
(Item no. 385435)
BAT.PAR 6 RGBUV (Item no. 385457)
LEDs 6 × RGBWA, each 8 W 6 × RGBUV, each 8 W Number of DMX
channels
1, 5, 7, 8 1, 4, 6, 7
Dispersion angle 25 ° Operating voltage
supply
100 – 240 V 50/60 Hz Replaceable battery pack, item no. 385488 (lithium-ion battery,
10.8 V, 1500 mAh) Fuse 5 mm × 20 mm, 5 A, fast blow Operating time after a
battery charging
max. 5 h
Power consumption 48 W
Technical specifications
48
BAT.PAR 6 RGBWA BAT.PAR 6 RGBUV LED spotlight
Page 49
BAT.PAR 6 RGBWA
(Item no. 385435)
BAT.PAR 6 RGBUV (Item no. 385457)
Dimensions (W × H × D)
250 mm × 254 mm × 130 mm
Weight 2 kg
Technical specifications
BAT.PAR 6 RGBWA BAT.PAR 6 RGBUV
49
LED spotlight
Page 50
9 Plug and connection assignments
This chapter will help you select the right cables and plugs to connect your valuable equip­ment so that a perfect light experience is guaranteed.
Please take our tips, because especially in ‘Sound & Light’ caution is indicated: Even if a plug fits into a socket, the result of an incorrect connection may be a destroyed DMX controller, a short circuit or ‘just’ a not working light show!
The unit offers a 3-pin XLR socket for DMX output and a 3-pin XLR plug for DMX input. Please refer to the drawing and table below for the pin assignment of a suitable XLR plug.
Pin Configuration
1 Ground, shielding 2 Signal inverted (DMX–, ‘cold signal’) 3 Signal (DMX+, ‘hot signal’)
Introduction
DMX connections
Plug and connection assignments
50
BAT.PAR 6 RGBWA BAT.PAR 6 RGBUV LED spotlight
Page 51
10 Troubleshooting
NOTICE! Possible data transmission errors
For error-free operation make use of dedicated DMX cables and do not use ordi­nary microphone cables.
Never connect the DMX input or output to audio devices such as mixers or ampli­fiers.
In the following we list a few common problems that may occur during operation. We give you some suggestions for easy troubleshooting:
Troubleshooting
BAT.PAR 6 RGBWA BAT.PAR 6 RGBUV
51
LED spotlight
Page 52
Symptom Remedy
Device not working, no light Check the mains connection and the main fuse. Not responding to DMX controller 1. Check the DMX connectors and cables to see if they
are properly linked.
2. Check the address settings and the DMX polarity.
3. Try using another DMX controller.
4. Check whether the DMX cables run near or parallel to high-voltage cables that may cause damage or interfer­ence to the DMX interface circuit.
The built-in battery can no longer be recharged
Do not attempt to replace the built-in battery yourself. Please contact our service centre.
If the procedures recommended above do not succeed, please contact our Service Center. You can find the contact information at www.thomann.de.
Troubleshooting
52
BAT.PAR 6 RGBWA BAT.PAR 6 RGBUV LED spotlight
Page 53
11 Cleaning
Clean the optical lenses, that are accessible from the outside, regularly in order to optimize the light output. The frequency of cleaning depends on the operating environment: wet, smoky or particularly dirty surroundings can cause more accumulation of dirt on the optics of the device.
n Clean with a soft cloth using our lamp and lens cleaner (item no. 280122). n
Always dry the parts carefully.
The fan grids of the device must be cleaned on a regular basis to remove dust and dirt. Before cleaning, switch off the device and disconnect AC-powered devices from the mains. Use a lint­free damp cloth for cleaning. Never use solvents or alcohol for cleaning.
Optical lenses
Fan grids
Cleaning
BAT.PAR 6 RGBWA BAT.PAR 6 RGBUV
53
LED spotlight
Page 54
12 Protecting the environment
For the packaging, environmentally friendly materials have been chosen that can be supplied to normal recycling.
Ensure that plastic bags, packaging, etc. are properly disposed of. Do not just dispose of these materials with your normal household waste, but make sure that
they are collected for recycling. Please follow the notes and markings on the packaging.
Batteries do contain some hazardous chemicals so they should not be thrown away with the normal household waste. They should be returned to the manufacturer for disposal or recycled elsewhere in accordance with your local regulations.
Remove lithium batteries from the device before disposal. Protect used lithium batteries against short circuit, for example by taping the poles.
Disposal of the packaging mate­rial
Disposal of batteries
Protecting the environment
54
BAT.PAR 6 RGBWA BAT.PAR 6 RGBUV LED spotlight
Page 55
This product is subject to the European Waste Electrical and Electronic Equipment Directive (WEEE) in its currently valid version. Do not dispose with your normal household waste.
Dispose of this device through an approved waste disposal firm or through your local waste facility. When discarding the device, comply with the rules and regulations that apply in your country. If in doubt, consult your local waste disposal facility.
Disposal of your old device
Protecting the environment
BAT.PAR 6 RGBWA BAT.PAR 6 RGBUV
55
LED spotlight
Page 56
Notes
56
BAT.PAR 6 RGBWA BAT.PAR 6 RGBUV LED spotlight
Page 57
Notes
BAT.PAR 6 RGBWA BAT.PAR 6 RGBUV
57
LED spotlight
Page 58
Notes
58
BAT.PAR 6 RGBWA BAT.PAR 6 RGBUV LED spotlight
Page 59
Page 60
Musikhaus Thomann · Hans-Thomann-Straße 1 · 96138 Burgebrach · Germany · www.thomann.de
Loading...