Model VT320VHB
Read these instructions completely before attempting to operate your new Enclosed LCD
User’s Guide
Page 2
Revision History
Date Rev No Summary Page
07/15/12 01 First Issue 10/18/12 02 Updated outline drawing to include DVI & S-Video 11/05/12 03 Corrected Resolution spec
5 4
32.0” NEMA 4 Fully Enclosed LCD 486-0035-00-01
2
Page 3
Safety Instructions
Read the Safety Instructions carefully and keep it for use later. The chassis metalwork of the module must be installed properly to the main earthing termination
for Class 1 equipment.
Care must be exercised in the application of the system to prevent overheating. Ensure that the
ambient temperature around the system does not exceed 60°C and provide adequate means of ventilation to achieve this.
When cleaning cut off the electrical supply at all times. Never use liquid or aerosol detergent,
use a soft damp cloth instead.
Never insert anything metallic into the enclosure. This may create an electric shock hazard or
hazard from rotating fan blades.
To avoid electric shock, never touch the inside of the system. There are no user adjustable
components inside, only a qualified technician should open the enclosure’s case.
If the LCD does not operate normally – in particular, if there are any unusual sounds or smells
coming from it – disconnect it immediately.
Do not put pressure on the LCD panel screen because it is very fragile. Always handle the system with care when moving it. Take care that the system is disposed of correctly at the end of its life. If in doubt refer to your
local ordinances or regulations for proper disposal.
A socket-outlet shall be installed near the equipment and shall be easily accessible.
Cleaning the LCD monitor
To clean the LCD panel:
Wipe the screen gently with a clean lens brush made of camel hair, or a soft, clean, lint free
cloth. This is to remove dust and other particles without scratching the LCD panel.
If it is still not clean, then wipe with a damp lint free cloth and blow on it to dry. Desirable cleaners are water, IPA (Isopropyl Alcohol) or Hexane.
Do not clean the panel with a Ketone type material (e.g. Acetone), or Ethyl alcohol, Toluene, Ethyl acid, Methyl chloride. These may permanently damage the polarizer due to chemical reaction.
Do not apply pressure to the LCD panel.
32.0” NEMA 4 Fully Enclosed LCD 486-0035-00-01
3
Page 4
Standard Technical Specifications:
LCD Monitor:
Size / Type Native Resolution Contrast Ratio Viewing Angles
Pixel Pitch Brightness (typical) Indoor - 850 cd/m²
Response Time (typical) 8ms Typical, 16ms Max. Colors Supported
32.0” WXGA TFT LCD 1366 x 768 4000:1 Horizontal: 89° Vertical: 89°
0.51075(H) x 0.51075(V)mm Outdoor – 1400cd/m² @ 80Klux
16.7 million
Touch Screen:
Touch Screen
N/A
Environmental:
Power Input Power Consumption Temperature
Humidity
Installation of Your Enclosed VESA Mount PC
Packaged with each carton will be: 1 – VT320VHB
1 - AC Power Cable 1 – DVI-D Cable 1 – S-Video Cable 1 – VGA Cable
32.0” NEMA 4 Fully Enclosed LCD 486-0035-00-01
100-240 VAC 1.5A 50/60 Hz 85 watts typical – 90 watts max. Operational: -4°F to 140°F -20°C to 60°C Storage: -13°F to 158°F -25°C to 70°C Operational: 0 to 90% RH NC Storage: 0 to 95% RH NC
4
Page 5
1 - Users Guide (Printed or on CD)
BEFORE MAKING ANY CONNECTIONS OR APPLYING POWER,
FIRST READ THROUGH THE ENTIRE MANUAL
Mounting Procedure
1- Secure the enclosure using 3/8-16 x .625” long screws. 2- Tighten all mounting hardware to a torque of 15 inch-pounds.
ATTENTION: Mounting hardware must be tightened to a torque of 15 inch-pounds to provide a proper panel mount and avoid potential damage. Vartech Systems assumes no responsibility for water or chemical damage to the monitor or other equipment within the enclosure due to improper installation.
3- Attach the power and system cables to the bottom side of the enclosure if you have not
already done so.
32.0” NEMA 4 Fully Enclosed LCD 486-0035-00-01
5
Page 6
Product Drawing: Detail –A–
32.0” NEMA 4 Fully Enclosed LCD 486-0035-00-01
6
Page 7
Connections to the Enclosed LCD:
Power Connection (Power In)
The Enclosed LCD includes an AC line cord which is 6ft long. VGA Port Connection
The Enclosed LCD is supplied with a circular to 15-pin D-Shell connector.
DVI-D Port Connection
The Enclosed LCD is supplied with a circular to DVI-I connector. The DVI connector is DVI-I but only supports DVI-D.
S-Video Port Connection
The Enclosed LCD is supplied with a circular to S-Video connector.
Composite Port Connection
The Enclosed LCD is supplied with a composite BNC connection.
LCD Monitor Warm-up Time
All LCD monitors need time to become thermally stable the first time you turn them on. Therefore, to achieve more accurate adjustments for parameters, allow the LCD monitor to warm (be on) for at least 20 minutes before making any screen adjustments.
Maintenance
The Enclosed LCD is designed to provide optimum service and performance with minimal maintenance including the occasional external cleaning. For cleaning the Enclosed LCD enclosure follow the suggested guidelines.
General – NEVER use abrasive cleaners or solvent-based cleaners!! Use a clean soft cloth. The Enclosed LCD should only be opened and serviced by a qualified technician. Keep the area around the Enclosed VESA Mount PC clear and free of excessive dirt or other contaminants.
32.0” NEMA 4 Fully Enclosed LCD 486-0035-00-01
7
Page 8
Controls Analog VR type Digital type On/Off – turns controller board power on VR toggle switch On/Off button Brightness – controls backlight brightness Rotary VR Brightness +/- buttons Menu – turns OSD menu On or Off (it will auto time off) (Function with signal input only) Select – Select function / Confirm
(under OSD menu on state) Move up to select individual RGB color level OSD page
(under OSD menu on state) + – increase the setting / moves the selector to the next function
(under OSD menu on state)
- - decrease the setting / moves the selector to the previous function
(under OSD menu on state) Load factory default Press and hold SEL DN
Lock OSD menu
(Function with signal input only)
Switch to next input source
(under OSD menu off state)
Menu button Menu button SEL DN SEL DN SEL UP SEL UP
+ +
- -
botton to power on the controller Press and hold MENU button for 15 seconds to enable / disable lock of the OSD menu + +
Press and hold SEL DN botton to power on the controller Press and hold MENU button for 15 seconds to enable / disable lock of the OSD menu
Selection page
Select input source
Auto Source Seek ON – Auto source select always enable
Video system selection*
Select input source to Analog RGB
Select input source to DVI
Select input source to S-Video 1
Select input source to Composite 1
Select input source to S-Video 2 (No function now)
Select input source to Composite 2 (No function now)
OFF – Disable auto source select function
Select Auto video system detection
Select PAL video system
Select PAL M video system
Select NTSC video system
Select NTSC 4.43 video system
Select SECAM video system
32.0” NEMA 4 Fully Enclosed LCD 486-0035-00-01
8
Page 9
Brightness and Contrast
Wide screen mode information display#
Exit Exit the OSD menu and save the settings
Select the input mode (1280 / 1360 / 1366 / 1368) to recognize and display the correct input signal information display on the OSD menu. 1280 : 1280x768 1360 : 1360x768 1366 :1366x768 1368 : 1368x768
Color
Auto RGB Calibration#
Brightness Increase/decrease brightness level.
Contrast Increase/decrease panel contrast level.
Saturation* Increase/decrease hue level.
Hue* Increase/decrease saturation level
Exit Exit the OSD menu and save the settings
Color Temperature (Adjust the warmness of the image displayed. The higher temperature the
coolest image looks like. The lower temperature the warmest image looks like.)
Press – or + (- + ) Total : 256 steps
Press – or + (- + ) Total : 192 steps
Press – or + (- + ) Total : 256 steps
Press – or + (- + ) Total : 128 steps
Yes No (See appendix IV)
Adjust red color level Press – or + (- +) Total :128 steps Adjust green color level Press – or + (- +) Total : 128 steps Adjust blue color level Press – or + (- +) Total : 128 steps
Press SEL UP/DN button to select item Set the color temperature to 4200K
Set the color temperature to 5000K
Set the color temperature to 6500K
Set the color temperature to 7500K
Set the color temperature to 9300K
Gamma adjustment
Exit Exit the OSD menu and save the settings
Position#
Autosetup Auto adjust the positions, phase, frequency
Frequency Adjust the image horizontal size
Phase Fine tune the data sampling position (adjust image quality)
32.0” NEMA 4 Fully Enclosed LCD 486-0035-00-01
Adjust Gamma settings (0.4 / 0.6 / 1.0 / 1.6 / 2.2)
Select Gamma to 0.4
Select Gamma to 0.6
Select Gamma to 1.0
Select Gamma to 1.6
Select Gamma to 2.2
Yes No
9
Page 10
Utilities
Image Horizontal
Position
Image Vertical
Position
Exit Exit the OSD menu
Use +/- to move the image horizontally Press – or + (- + )
Use +/- to move the image vertically Press – or + (- + )
OSD Timeout : 0 / 10 / 20 / 30 / 40 / 50 / 60 seconds (Always on when set to 0)
Exit the OSD menu
OSD setting
Press – or + (- + ) OSD menu horizontal position
Press – or + (- + ) OSD menu vertical position
Press – or + (- + )
Load Factory Default Initialize the setting stored in non-volatile memory
Sharpness Adjust sharpness level
Press – or + (- + ) Total : 49 steps
Exit Exit the OSD menu
For Additional Assistance
Contact Your VarTech Sales Representative
Vartech Systems, Inc.
11529 Sun Belt Ct.
Baton Rouge, LA 70809
800-223-8050
Fax: 225-297-2440
www.vartechsystems.com
32.0” NEMA 4 Fully Enclosed LCD 486-0035-00-01
10
Loading...