Fitting instructions
If in doubt, consult a qualified electrician.
1. Always disconnect the mains before beginning any electrical work
2. Clip grid modules into grid plate
3. Make electrical connections making sure any bare wires are covered by
appropriate sleeving
4. The grid plate must be earthed using the earth terminal provided
5. Screw grid plate to wall using larger fixing screws supplied
6. Attach faceplate using smaller fixing screws supplied
7. Switch on the mains supply.
WARNING: Do not apply products with metal faceplates directly to freshly
plastered or damp surfaces as product may tarnish. If in doubt, use polythene
as a temporary gasket to protect the product. Do not use masking tape on
metal plates.
Guarantee: If the unit becomes faulty within 10 years of purchase, you may
return it for to either address listed in the overview section above, together
with a letter stating the guarantee registration number below, the date and
place of purchase, your contact details and return address, the type and
wattage of the lighting or other load being controlled and the details of the
fault. This guarantee states Varilight’s entire liability, which does not extend
to cover consequential loss or damage or installation costs arising from a
defective product. The guarantee does not apply to problems arising from
any incompatibility between your lamps and the dimmer switch. This
guarantee does not in any way affect the statutory rights of the purchaser
and is offered so that you may have the benefit of our technical facilities.
In many cases products don’t need replacing, so for further information and
help with troubleshooting, see our FAQ page at www.varilight.co.uk/faqs
contact our Customer Services by calling +44 (01293) 223333 or create a
support ticket at www.varilight.co.uk/help
Doyle & Tratt Products Ltd, Carylls Lea, Faygate, Horsham, W. Sussex,
RH12 4SJ, UK. +44 (01293) 223333
Varilight Europe Kft, 2600 Vác, Althann Mihály Frigyes utca 2, Hungary.
Guarantee Registration: PGRID003
VARILIGHT Grid Dimmers
Maximum Loads Per Grid Faceplate
Important: Before using this product with dimmer modules,
read the guidance below on maximum loads permitted per
plate.
The loadings below are for LED and Halogen loads.
.
Plate Size
Single (1 and 2-Gang) 400W 400W
Twin (3 and 4-Gang) 800W 800W
Maximum
Loading
(Per Plate)
Maximum
Loading
(Per Row)
, or
Double Twin (6 and 8-Gang) 1200W 800W
Triple Twin (9 and 12-Gang) 1800W 800W