This document is confidential and proprietary to PerkinElmer
The following pages contain the “User Manual”
Version
REVISION
1 Initial release S. Arnold TBA 2013-11-29
SECTIONS
CHANGED
ORIGINATOR CN DATE
TBA, Ver.01
PUB XRpad 4336
MED User Manual
Printed document is valid for use within the day printed.
Use or verify the latest revision of document in Document Control
Directory
Page 0 of 34
XRpad™ 4336 MED
Before using the detector, be sure to read this manual thoroughly along with any other
Digital X-Ray Detector System
DI GIT AL IM AG I N G
U S E R M A N U A L
manuals for the software and other system components. Keep this manual where it is
easily accessible.
ww w .p er k in e lm e r. c om
PLEASE NOTE
To avoid personal injury or product damage, read the manual and all accompanying
information carefully before installation or use of the XRpad™ 4336 MED detector.
The detector is intended for use by trained and qualified professional personnel who are
knowledgeable with the use of x-ray detectors, x-ray systems, and electrical equipment.
The user is responsible for using and maintaining the detector according to prescribed
installation, usage, maintenance, handling and storage specifications. To keep the detector
and its accessories in a safe and proper condition, only trained and qualified professional
person(s) shall be in charge of maintenance.
X-ray imaging, image processing, image acquisition, and data storage must be performed in
accordance with the applicable laws. The user is also responsible for compliance to laws
pertaining to the privacy of image data.
In no event is PerkinElmer liable for direct, indirect, or consequential injury, damage, or loss
of equipment operation time or image data arising from the use of the x-ray detector, its
components, and or accessories.
Protection against Ionizing Radiation
U S E R M A N U A L
Exposure of any part of the human body to x-radiation may be harmful to health. Whenever
x-ray equipment or radioactive sources are in use, appropriate safety precautions and
measures shall be instituted, and all regulatory requirements must be met. It is the
responsibility of the x-ray system installer, operator, and user to comply with applicable
requirements.
The x-ray detector is intended to be installed, maintained, and used by qualified professional
personnel who are trained and qualified in the installation, maintenance, and use of x-ray
equipment.
The x-ray detector does not contain a primary barrier for x-rays or Gamma rays. The
x-ray system installer or manufacturer must provide the necessary protection based on the x-ray
system’s intended use.
For portable applications the x-ray system installer or manufacturer must provide the necessary
training for the operator to protect them self, the patient, or surrounding persons.
ww w .p er k in e lm e r. c om XR p ad ™ 43 3 6 ME D 2
FOR YOUR SAFETY
To avoid personal injury or product damage, read this manual and all accompanying information
carefully before handling, installing, or using the XRpad™ 4336 MED detector. Follow all
instructions, warnings, and cautions in this manual and all warnings and cautions printed on the
warning label. Ignoring instructions, warnings, or cautions in the handling, installing, or using of the
detector may result in personal injury, death, or product damage. Keep this manual for future
reference.
Meaning of Caution Signs
U S E R M A N U A L
DANGER
WARNING
Caution
Note:
This indicates a potentially hazardous situation which, if ignored, will result in
severe personal injury, death, or substantial product damage.
This indicates a potentially hazardous situation which, if ignored, may result in
severe personal injury, death, or substantial product damage.
This indicates a potential hazardous situation which, if ignored, may result in
minor or moderate personal injury or damage to the product.
This emphasizes or supplements important information about the main text.
Installation and Environmental Use
Do not operate the x-ray detector in or around flammable gases, gas mixtures,
WARNING
Caution
WARNING
WARNING
liquids, chemicals, or other substances. Ignoring this warning may result in
explosion, fire, or electric shock, which may result in severe personal injury,
death, or substantial product damage.
Do not operate the x-ray detector in a location with the following conditions.
• Close to fluid or places where fluid is used
• Close to heat sources, such as a heater
• High temperature environment
• High humidity environment
• High condensation environment
• Extreme cold environment
• Dusty environment
• Salty or sulphurous environment
• Near a vibrating environment
Ignoring this caution may result in personal injury or damage to the product.
Do not connect the x-ray detector to any component or accessory, other than
manufacturer’s specified components and accessories. Ignoring this warning may
result in explosion, fire, or electric shock, which may result in severe personal
injury, death, or substantial product damage.
Do not modify or alter the x-ray detector, its components, or accessories.
Ignoring this warning may result in explosion, fire, or electric shock, which may
result in severe personal injury, death, or substantial product damage.
ww w .p er k in e lm e r. c om XR p ad ™ 43 3 6 ME D 3
Interface and Power Unit and Cables
Be sure to turn OFF the power of the XRpad™ 4336 MED detector, including
turning off the power supply and or removal of the XRpad™LBP (Lithium
WARNING
WARNING
WARNING
WARNING
Battery Pack) before servicing, maintaining, connecting, or disconnecting the
cables or accessories.
Do not touch the power supply, Lithium Battery Pack, detector, cable, connector,
or any other electrical component or equipment with wet hands. Ignoring this
warning may cause electrical shock, which may result in severe personal injury,
death, or substantial product damage.
Disconnect the cables by pulling on the connector and not the cable itself.
Ignoring this warning may cause electrical shock, which may result in severe
personal injury, death, or substantial product damage.
Do not modify the cables or subject the cable to external stress or damage. Avoid
placing anything heavy, including the detector, on the cable, stepping on the
cable, pulling the cable, or subjecting the cable to excessive bending or bundling.
Ignoring this warning may cause cable failure resulting in electrical shock, which
may result in severe personal injury, death, or substantial product damage.
Do not turn ON the power supply or x-ray detector when condensation is formed
on the system. Ignoring this warning may cause electrical shock, which may
result in severe personal injury, death, or substantial product damage.
U S E R M A N U A L
Handling
WARNING
WARNING
Caution
Caution
Caution
Caution
Never disassemble, modify, or alter the x-ray detector, its components,
Lithium Battery Pack, battery charger, or accessories. Ignoring this warning
may cause electrical shock, and/or unknown hazards, which may result in
severe personal injury, death, or substantial product damage.
Do not touch the interface and power unit, or cable and the patient at the same
time. Do not let the patient touch the interface and power unit, or cable.
Ignoring this warning may cause electrical shock and or unknown hazards,
which may result in severe personal injury, death, or substantial product
damage.
Place the x-ray detector horizontally on a flat, stable surface. If the detector is
placed vertically or in any tilted position, the detector must be securely placed
in the Bucky tray. Ignoring this caution may result in personal injury or
damage to the product.
Do not exceed the maximum load weight of 150 kg distributed around the
overall surface of the detector (Uniform Load).
Do not exceed the maximum load weight of 100 kg distributed on an area of
40 mm in a diameter of the detector surface (Local Load).
Do not drop the detector. If the detector is dropped, remove the detector from
service and inform your establishment safety representative immediately to
verify or re-validate the proper function of the detector prior to resuming use
of the detector. Further use under abnormal conditions may result in severe
personal injury, death, or substantial product damage.
ww w .p er k in e lm e r. c om XR p ad ™ 43 3 6 ME D 4
Battery
WARNING
WARNING
WARNING
Do not use the XRpad™ LBP (Lithium Battery Pack) if the casing is broken or
if it emits an unusual odor, smoke, or excessive heat, or if it leaks any substance.
Avoid contact with any substance seeping from the battery pack. If any fluid
touches your skin or eyes, wash the affected area with clean running water and
immediately seek medical attention.
The cells within the XRpad™ LBP contain toxic substances. Do not attempt to
open the battery packs. Do not insert any object into the battery pack or use
any device to pry at the battery pack casing. Attempting to open the XRpad™ LBP casing will damage the casing which could cause the LBP to release toxic
and harmful substances, causing injuries such as electric shock, burns, or cause a
fire, and will render the pack unusable.
Observe and follow all safety information in this manual and on the warning
label found on the XRpad™ LBP. Ignoring warning may result in personal
injury or damage to the product.
U S E R M A N U A L
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
Use only charging devices approved by PerkinElmer and never attempt to
bypass or override their charging protection circuits.
Keep out of reach of children.
Remove the XRpad™LBP if the XRpad™ 4336 MED detector is not likely to
be used for some time.
Do not submerge the XRpad™ LBP in water or other liquid.
Do not charge the XRpad™ LBP near flammable materials
Do not connect the XRpad™ LBP to an electrical outlet directly, or to any other
electrical source not described in the manual.
Do not drop or hit the battery against hard objects since this may cause damage
to the LBP and risk release of the battery toxic and harmful substances, causing
injuries such as electric shock, burns, or cause a fire, and will render the
XRpad™ LBP unusable.
Do not use the Battery Charger in the patient environment
Caution
ww w .p er k in e lm e r. c om XR p ad ™ 43 3 6 ME D 5
Risk of explosion, personal injury, or damage to product if the Battery
XRpad™ LBP is replaced by non-OEM approved component.
When a Problem Occurs
If any abnormal condition is evident such as smoke, fumes, or strange sounds,
unplug the power supply from the AC outlet, and inform your establishment
WARNING
WARNING
safety representative immediately to contact your dealer, distributor, or
PerkinElmer.
Further use under abnormal conditions may result in severe personal injury,
death, or substantial product damage.
When liquid has been spilled into, or on any part of the x-ray detector, power
supply, Lithium Battery Pack, battery charger, or when the detector, its
component, or accessory is dropped, unplug the power supply from the AC
outlet, and inform your establishment safety representative immediately to
contact your dealer, distributor, or PerkinElmer.
Further use under abnormal conditions may result in severe personal injury,
death, or substantial product damage.
Maintenance and Inspection
U S E R M A N U A L
WARNING
WARNING
WARNING
Caution
Turn OFF the power of the detector when the inspections indicated in this
manual are going to be performed. Ignoring this warning may result in electric
shock, which may result in severe personal injury, death, or substantial product
damage.
When the detector system is going to be cleaned, turn OFF the XRpad™ 4336 MED, remove the XRpad™ LBP, and or unplug the power supply cable from
the AC outlet. Never use thinner, benzine, acetone, or other flammable cleaning
agents. Ignoring this warning may result in explosion, fire, or electric shock,
which may result in severe personal injury, death, or substantial product damage.
The XRpad™ 4336 MED must be repaired by PerkinElmer authorized
personnel only. Ignoring this warning may result in explosion, fire, electric
shock, or unknown hazards, which may result in severe personal injury, death, or
substantial product damage.
Follow the manufacturer’s recommendation for inspecting the detector before
use.
ww w .p er k in e lm e r. c om XR p ad ™ 43 3 6 ME D 6
ww w .p er k in e lm e r. c om XR p ad ™ 43 3 6 ME D 8
1 Scope
This document describes design elements and respective interfaces for the XRpad™ 4336 MED
detector. Applicable mechanical, electronic, and software interfaces are addressed.
PerkinElmer digital X-ray Flat Panel Detectors and accessories are designed to be integrated into
products by x-ray system manufacturers. Manufacturers are responsible for qualifying, validating, and
certifying their products for their intended uses and meeting all applicable regulatory requirements.
2 Intended Use / Indication for Use
The XRpad™ 4336 MED detector, when used with a radiographic imaging system, is intended for
use in generating radiographic images of human anatomy for diagnostic x-ray procedures, wherever
conventional screen-film (SF), digital radiography (DR), or computed radiography (CR) systems may
be used. It is not intended for mammographic use.
Final application and intended use is based on the completed x-ray system design. It is the
responsibility of the x-ray system manufacturer to confirm the efficacy and compliance of the
x-ray system for its intended use, inclusive of the detector. The Digital Radiography Software referred
to in this manual is medical imaging software for radiography, which is typically supplied by the x-ray
system manufacturer or third-party provider and is not part of the PerkinElmer XRpad™ 4336 MED
detector.
U S E R M A N U A L
3 Audience
This document is for professional users from Original Equipment Manufacturers (OEMs) and system
installers who are responsible for installing the XRpad™ 4336 MED detector into an x-ray system.
4 Abbreviations
Table 1 Abbreviations
Abbreviation Description
FoV Field of View
fps Frames per second
I/F Interface
IP Internet Protocol
LED Light Emitting Diode
SF Screen Film
CR Computed Radiography
DR Digital Radiography
OEM Original Equipment Manufacturer
5 References
Table 2 References
Document Name Document #
1 XRpad™ LBC Reference Manual 620-005121-002
2 XRpad™ LBP Reference Manual 620-005149-001
3 Digital Radiography Software Manual Supplied by OEM
ww w .p er k in e lm e r. c om XR p ad ™ 43 3 6 ME D 9
~
XRpad
4336
6 Definition of Symbols
Table 3 Symbols
Symbol
This Way Up
Handle with Care
Keep Dry
Reusable
Description
Disposal (WEEE)
Refer to Instruction Manual
U S E R M A N U A L
Caution
Manufacturer‘s name and address.
Date of Manufacture, YYYY=Year, MM=Month
Authorized representative in the European Community
Protection Class I
Wireless Connectivity
/LAN Connection / Missing LAN Connection
Do not expose to fire
Keep away from children.
UL Recognized component mark for US and Canada
Conformity European - Hereby, PerkinElmer Inc., declares that this
0050
MED is in compliance with the essential requirements and other relevant provisions of
Directive 1999/5/EC and 93/42/EEC. “0050” shows the notified body number for MDD.
™
ww w .p er k in e lm e r. c om XR p ad ™ 43 3 6 ME D 10