Varad SPIDER-VS260, EVO-VS360, AERO-VS460, RAPTOR-VS560 User Manual

®
Tri-Color Series
Thank you for purchasing our new generation of SCANNERS . With our latest LED technology, microcontroller and software design we have added many new features to provide you with the best visual theft deterrence ever. This generation of SCANNERS have 40 new and exciting patterns along with three color LEDs, adjustable speeds and programmable features. You can select from a variety of color changing, glowing and strobe patterns. Each pattern is unique and will provide extra excitement for visual theft deterrence!.
®
®
®
IM-VSX60V2
Features:
• 40 Selectable patterns
• Tri - Color SMT LED - Red/Blue/Purple
• Network multiple SCANNERS
®
• Three speed selections.
• Low power enable/disable mode.
• Temporary shut down.
• Temporary low power mode.
Mounting the SCANNERS :
®
Find suitable location for installation. Drill any holes if necessary and clean surface with rubbing alcohol to remove oils. Use the provided 3M™ double sided tape and mount. Refer to following diagram for wiring instructions.
Installation with alarm system:
SCANNERS will activate when alarm system is activated.
Black
Red
Orange
White
®
SCANNERS
®
Battery negative or chassis ground
Battery positive (constant) Alarm system accessory output or ground
output when armed.
Network for multiple SCANNERS . See
®
“Networking” for details
SCANNERS will activate when engine is turned off.
Black
Red
Orange
White
®
SCANNERS
®
Battery negative or chassis ground Battery positive (constant) Ignition - Ground when engine is “OFF”.
(See fuse box) Network for multiple SCANNERS
®
installation. See “Networking” for details
Networking multiple SCANNERS :
This type of installation requires multiple SCANNERS .
®
®
Be sure to connect all wires together at the same location. This will ensure proper network communication.
SCANNERS
SCANNERS
SCANNERS
®
®
®
White -
Orange
Red
Black
Connect all white wires together.
How to operate SCANNERS :Installation without alarm system:
Program button
Program button on Raptor
(Use a small paper clip)
®
Ignition
OFF
Ignition
ON
How to select Patterns:
Ignition must be “ON”, press program button (Paper clip for VS560C) momentarily and SCANNERS will display
®
next pattern. Repeat to view next pattern. The SCANNERS has a total of 40 patterns. Note! - After 30 seconds you cannot change patterns. To change patterns after 30 seconds cycle the ignition.
How to change speed:
Ignition must be “ON”, push program button rapidly two times. SCANNERS will display the next speed. Repeat to select next speed. The SCANNERS has three speed
®
®
selections.
®
Special Modes:
Occasionally, you may want to leave your vehicle for extended periods of time. In order to save power and maintain visual theft deterrence you can activate the low power mode. Or, you can leave the SCANNERS off
®
completely. The following are instructions for each option.
How to select low power mode momentarily:
Ignition must be “ON”, hold program button until no.1 and no.2 LED turn on then release (approximately 5 seconds for no.1 LED and additional 5 seconds for no.2 LED). SCANNER S will flas h tw o ti mes to confirm that SCANNERS will be in low power mode when ignition is
®
®
turned off. This mode is temporary and will be reset when ignition is turned on.
How to shut down momentarily:
Ignition must be “ON”, hold program button until no.1 LED is on (all networked units) then release (approximately 5 seconds for no.1 LED to turn on). SCANNERS (all networked units) will flash one time to confirm that SCANNERS will remain off when ignition is turned off.
®
®
How to enable/disable low power mode:
If you’re not sure how long your car will be parked you can program SCANNERS to enable/disable the low power mode. When the low power mode is enabled, a clock begins to count 5 days. After 5 days the SCANNERS will
®
®
activate the low power pattern with a single flashing LED. The count down begins each time the ignition is turned off. For network installations, only one unit needs to be programmed. You do not need to program all units!
How to enable/disable low power mode (contd.) Follow these steps:
Ignition must be “OFF”, hold program button until no.1 LED turns on (all networked units, approximately 7 seconds). Continue holding program button and turn ignition “ON” then release program button. At this time no.2 LED will turn on (all networked units). Now push program select button one more time and the no. 3 LED will turn on (all networked units). The SCANNERS is now
®
in the low power enable/disable mode. To enable the low power mode push program select button and no.7 LED will turn on (all networked units). This confirms that the SCANNERS will activate the low power mode after
®
approximately 5 days. To disable the low power mode push program select button and the no.7 LED will turn off (all networked units). Turn ignition off to save and exit this mode. The SCANNERS will flash once (all networked
®
units) each time the ignition is turned off to confirm that the low power mode is enabled. NOTE! Due to a wide variety of tolerances in electronic components. The low power mode timing will vary between 2 to 8 days.
How to reset to default mode:
Under certain circumstances it may be necessary to reset the SCANNERS (all networked units) to default mode. Situations that will require a reset are when networked SCANNERS are out of sync or you simply want to return to the default mode. The following steps will allow you to reset the SCANNERS :
®
®
®
How to reset to default mode (contd.)
Follow these steps: Ignition “OFF”, hold program button until no.1 LED turns on (all networked units, approximately 7 seconds). Continue holding program button and turn ignition “ON” then release program button. At this time no.2 LED will turn on (all networked units). Now, turn off ignition and SCANNERS (all networked units) will flash red then blue once to confirm reset.
30 Second lock out:
The SCANNER patterns can only be changed for 30
®
seconds after ignition is turned on.
Trouble shooting - frequently asked questions
SCANNERS does not remember pattern
®
Memory loss will occur whenever the positive wire loses contact with the battery for a moment. This can occur if the positive wire is attached to the wrong contact on the fuse box or some other location in the vehicle. Try to connect the SCANNERS positive wire directly to the
®
battery positive terminal.
SCANNERS does not work when connected to my alarm
If you want the SCANNERS to turn on when you activate
®
®
you alarm system you must connect the orange SCANNER wire to the grounded output (when armed) of your alarm system. DO NOT CONNECT TO THE LED OUTPUT!. The LED output wire only provides a 2-3 volts flashing. Refer to your alarm system installation manual or ask your local dealer for the correct ground output wire.
My SCANNERS patterns are out of sync.
®
This can happen for many reasons. If you push the program select button too fast or too soon before a pattern cycle is finished. If there is a poor or loose connection on the network wire line (white wire). If you push buttons on more than one unit at a time. If this occurs you can perform
®
a “reset”. Refer to the “How to reset to default mode” section.
My SCANNERS does not turn off when I arm my
®
alarm system.
This situation is caused by ground leakage through the ignition kill relay. You must install a diode per the following diagram.
®
SCANNERS
Alarm system
Varad’s product warranty covers against breakage due to defects in materials or workmanship for one year from the date of purchase. Warranty is only valid with proof of purchase from an Authorized Varad Dealer. Varad’s warranty program does not cover cosmetic damage, and damage due to acts o f God, acci dent, misuse, abuse or negligence to the product. Repair or replacement as provided under this warran ty is the exclusive remedy of the consumer. Varad shall not be liable for any incidental or consequential damage for breach
®
of any express or implie d warranty on this product. Except to the extent provided by this warranty or prohibited by applicable law, there are no implied nor expressed warranties or merchantability or fitness for a particular purpose of this product.
Ground output
when armed
Red
Orange
Switching diode 1N4148, 1/2 Watt
www.varad.com
tech supp ort@ varad.com
Desig ned a nd E ngineere d in U.S .A. • Asse mbled in China
Black
Starter Kill
Relay