1. PRODUCT OVERVIEW, SCOPE OF DELIVERY, SERVICE 1. PRODUCT OVERVIEW, SCOPE OF DELIVERY, SERVICE
MIGHTY MEDIC Vaporizer functional elements:
Filling Chamber
Cooling Unit
Minus Temperature
Button
Type Label
(on the rear)
ON/OFF Switch
Charging Socket
Filling Chamber Tool
(under the Type Label)
Mouthpiece
Actual Temperature Display
Plus Temperature
Set Temperature
Battery Charging Display
Button
Display
Delivery includes MIGHTY MEDIC:
1 pc. MIGHTY MEDIC Vaporizer
1 pc. Instructions for Use
1 pc. Power Adapter
4 pcs. Spare Seal Rings
1 pc. Cleaning Brush
1 pc. Magazine with 8 pcs. Dosing Capsules
1 pc. Herb Mill
3 pcs. Spare Screens
3 pcs. Lip Piece
Please check whether all components have been included.
If not, please inform our Service Center.
Operating life:
The MIGHTY MEDIC Vaporizer has an average expected operating life of:
– approx. 1,000 operating hours
– approx. 5 years
The batteries have an average expected operating life of:
– approx. 500 operating hours
– approx. 2 years
For exchanging the batteries, please contact our Service Center.
Service
Contact in case of technical problems or questions about the device:
Storz & Bickel Service Center
Tel.: +49-74 61-969707-0 · e-mail: info@vapormed.com
For repairs, warranty claims, or disposal, please send the device to
the following address:
Storz & Bickel & Co. KG
Service Center
In Grubenäcker 5-9
78532 Tuttlingen, Germany
7 6
2. EXPLANATION OF SYMBOLS, SAFETY RECOMMENDATIONS
2. EXPLANATION OF SYMBOLS, SAFETY RECOMMENDATIONS
Please read the following
safety recommendations
thoroughly and carefully
before using the device.
These Instructions for Use are
a significant part of the MI GHTY MEDIC Vaporizer and must be provided to the user.
These instructions given in this Instructions for Use must be strictly
observed as they are extremely
Explanation of Symbols
Please follow these instructions carefully!
(according to IEC 60601: 2005)
Warning !
In order to avoid injuries to persons and damage to the equipment,
it is mandatory to observe instructions marked with this symbol.
Note /Tip!
This symbol always gives you technical information or useful tips
regarding the MIGHTY MEDIC Vaporizer.
SN
Symbol for serial number - followed by the serial number of the
medical product
Symbol for the manufacturer - the manufacturer‘s name and address are next to the symbol
The medical product was introduced after 13 August 2005. The
product may not be disposed of in normal household waste. The X
on the trash can indicates the necessity of disposing of this product
separately.
The device contains a built-in rechargeable lithium-ion battery that
must be discharged before disposal.
important to ensure safety during
installation, use and maintenance
of the MIGHTY MEDIC Vaporizer.
Please keep this brochure in a safe
place for future reference.
You may download the current
Instructions for Use for the
MIGHTY MEDIC Vaporizer on
www.vapormed.com.
IP 22
0123
REF
The MIGHTY MEDIC Vaporizer is protected by an angle of 15°
against dropping water (IP 22). The device should nevertheless be
protected against moisture and rain. Do not use in the bathroom or
above water.
EU conformity symbol: A 4-digit number after the CE marking
indicates that a notified body is involved in the conformity
assessment procedure.
Symbol for order number - followed by the order number of the
corresponding medical product (or part)
Safety tested and production monitored by TUEV SUED according
to IEC 60601-1, CAN/CSA C22.2 No. 60601-1 and ANSI/AAMIES
60601-1.
Caution! Hot surfaces!
Do not touch metal parts!
Keep away from sunlight
Protect against moisture and humidity
DC (direct current)
Interference may occur in the vicinity of equipment marked with
the following symbol.
Temperature limits of ambient temperature
Humidity limitation
9 8
2. EXPLANATION OF SYMBOLS, SAFETY RECOMMENDATIONS
2. EXPLANATION OF SYMBOLS, SAFETY RECOMMENDATIONS
Air pressure limitation
INT:
7 on/ 30 off
The following symbols relate to the power adapter:
intermittent operation
Do not reuse
Safety Category II device
UL Recognized Component Mark: This symbol indicates that the
corresponding devices are listed by UL
Restriction on the use of certain hazardous substances in
electrical and electronic equipment
Efficiency Level 5
Efficiency of power adapter
Symbol for FCC declaration of conformity
(electromagnetic interference approval in the USA)
Equipment with this symbol may only be used in the house
(dry surroundings).
Safety Recommendations
The packaging material (plastic bags,
boxes etc.) must be kept out of the
reach of children as it is a potential
source of danger.
People who require assistance must
be supervised constantly during
inhalation. Such persons often
underestimate the hazards involved
(e.g. strangulation with the power
adapter cord), thus resulting in a risk
of injury.
The device contains small parts
which can block the respiratory tract
and lead to choking. Therefore,
make sure that you always keep
the MIGHTY MEDIC Vaporizer and
the accessories out of the reach of
babies and infants.
When charging the battery, use the
power adapter supplied with the
Vaporizer only. The use of products
from other sources can damage the
batter y.
If you have any concerns, ask a spe-
cialist to check whether the electrical
system is in accordance with the
local safety regulations.
If there are any problems during
operation, immediately pull out the
power adapter from the socket.
The power adapter cord must be
unwound over its entire length
(avoid rolling up and overlapping the
cord). It must not be exposed to any
impacts and must be kept out of the
reach of children. Also, it must not be
kept near liquids or sources of heat
and must not be damaged. Do not
wind the power adapter cord tightly,
nor pull it over sharp edges and never
crush or kink it. If the power adapter
cord is damaged, please contact our
Service Center to have it replaced.
Never try to repair a power adapter
cord yourself!
The use of multiple sockets and /or
extension cables is not recommended. However, if this is absolutely
necessary, only products with a quality certificate (such as UL, IMQ, VED,
+S etc.) may be used, provided the
specified power exceeds the power
required (A= Ampere) by the devices
that are connected.
After use, the Vaporizer must be
placed on a stable, flat surface. To
be used only at a sufficient distance
away from heat sources (ovens,
stoves, fireplaces), and in locations
where the ambient temperature cannot drop below +5°C (+41°F). Store
the Vaporizer and power adapter in
a dry place protected against the effects of weather and out of the reach
of children or unqualified persons.
It cannot be used in damp locations
(such as bathrooms etc.).
11 10
2. EXPLANATION OF SYMBOLS, SAFETY RECOMMENDATIONS
2. EXPLANATION OF SYMBOLS, SAFETY RECOMMENDATIONS
Do not operate the Vaporizer close to
flammable objects such as curtains,
tablecloths, or paper.
Keep the Vaporizer and power adapt-
er away from pets (e.g. hamsters,
mice) and other animals which could
damage the insulation of the power
adapter cord.
The Vaporizer and power adapter
may only be repaired by our Service
Center. Incorrectly performed repairs
without the use of original spare parts
can prove dangerous to the user.
Danger to life when opening the
power adapter as live components
and connections are exposed.
The Vaporizer must never be re-
paired or transported when the power
adapter is plugged in.
The Vaporizer and power adapter
must never be operated when the
power adapter cord is faulty.
Do not put any objects into the open-
ings of the device.
Do not leave the Vaporizer unat-
tended while it is being operated.
After use, switch off the heater.
The Vaporizer may not be obstructed
while the device is being used, nor
while it is cooling down.
Caution! Hot surfaces!
The Filling Chamber is made of
metal; do not touch it when it is hot.
The Dosing Capsule is made of
metal; do not touch it when it is hot.
Before cleaning, disconnect the
power adapter from the socket. The
Vaporizer and the power adapter
should be cleaned only with a dry
cloth - or a damp cloth if absolutely
necessary. Never immerse the Vaporizer or the power adapter in water
or any other liquid, nor clean it with
direct jets of water or steam.
The Vaporizer and the power adapter
must not be used in damp or wet
conditions.
The Vaporizer is protected by an an-
gle of 15° against dropping water (IP
22). The device should nevertheless
be protected against moisture and
rain. Do not use in the bathroom or
above water.
Never touch the Vaporizer or power
adapter with wet or damp parts of the
body.
Never operate the Vaporizer or power
adapter when it is wet or damp. If the
Vaporizer or the power adapter gets
wet, it must be checked by our Service Center for damage to electrical
components.
Do not use in an atmosphere with risk
of explosion or ignition.
Never allow the Vaporizer or the
power adapter to be used by children
or unqualified persons.
Only use original Storz & Bickel ac-
cessories and spare parts.
The manufacturer is not responsible for any damage
or personal injury caused
by inappropriate, incorrect or irresponsible use.
3. INTENDED USE
The MIGHTY MEDIC Vaporizer is in-
tended for vaporizing and then inhaling cannabinoids from hemp flowers
(cannabis flos).
The goal is the application of the ac-
tive ingredients in the human body via
the alveoli for the appropriate medical
indication.
It is suitable for the temporary inhalative application of cannabinoids
prescribed by a physician for use at
home, in a hospital, or doctor’s office.
13 12
4. IMPORTANT REMARKS4. IMPORTANT REMARKS
The MIGHTY MEDIC Vapor-
izer ensures the highly effec-
tive, safe, and fast-acting application of cannabinoids. The patient
must undergo a medical examination
before the beginning of treatment.
The MIGHTY MEDIC Vaporizer is not
intended for use in children and youth
under age 18. Adults may use the device following the Instructions for Use
or physician’s instructions.
Due to hygienic reasons, the
MIGHTY MEDIC Vaporizer
may be operated only with attached (disposable) Lip Piece on the
Mouthpiece (see Chapter 8.1. „Disposable Lip Piece for Hygienic Use“
from page 29 onwards).
The device is not to be used, if
the user has respiratory tract
or lung conditions. Depending
on the density, the vapor could irritate
respiratory tracts or lungs, which can
lead to coughing.
The application and inhalation is described in Chapter 8.2. “Cooling Unit
with Mouthpiece” on page 30.
Before every use by another person,
the Cooling Unit and the Vaporizer
must be cleaned thoroughly (see information on the Cooling Unit and
Vaporizer from page 28 onwards).
Please note that damaged or
brittle Lip Pieces are not to be
used.
At a certain dosage, cannabis
can have a psychotropic
(mind-altering) effect.
Thus, there is a potential for abuse,
which governments in nearly all countries of the world counteract with corresponding laws.
Use only medicinal hemp flowers
(cannabis flos) prescribed by your
physician and purchased from a pharmacy. Otherwise you may be at risk of
breaking the law.
In case of doubt, ask your physician,
pharmacist, or the responsible authorities about the current laws at your
place of residence.
Cannabinoids vaporize at temperatures over 180°C (356°F) and then
form an aerosol with an average droplet size (MMAD) of 0.64 µm (micrometer) that can be inhaled and respired.
The droplets are absorbed in the alveoli and enter the bloodstream (systemic absorption).
When cannabinoids are inhaled, the
onset of the effect takes approx. 1-2
min. and the effects last for 2-4 hours.
Our Service Centre is available to answer your questions and receive your
comments and suggestion concerning the MIGHTY MEDIC Vaporizer.
You may download the current Instructions for Use for
the M IGHTY MEDIC Vaporiz-
er on www.vapormed.com. Here you
will find the up-to-date information to
the current state of research.
If questions occur about the medical
use of cannabinoids or cannnabis
please contact your doctor, pharmacist or manufacturer of medical hemp
flowers (Cannabis flos).
15 14
4. IMPORTANT REMARKS
Operating Conditions
Ambient conditions in which the
specified aerosol characteristics are
guaranteed:
+35°C
+5°C
Ambient temperature:
+5°C to +35°C (+41°F to +95°F)
15% - 90%
Relative humidity of ambient air:
15% to 90%
Atmospheric pressure:
700 hPa to 1060 hPa
The device features interference suppression acc. to EN 60601-1-2 (see
Chapter 10.5. “Information on Electromagnetic Compatibility“, page 40).
Radiofrequency emitting equipment
(e.g. mobile phones) should not be
used in the immediate vicinity of the
device. In case of doubt, contact qualified personnel.
Storage and Transport Conditions
+60°C
-20°C
Ambient temperature:
-20°C to +60°C (-4°F to +140°F)
15% - 90%
Relative humidity:
15% to 90%
Atmospheric pressure:
700 hPa to 1060 hPa
Do not store any parts of the M IG HTY MEDIC Vaporizer in wet rooms (e.g.
bathroom) or transport near damp
objects.
Extreme fluctuations in ambient temperature can lead to condensation
and damage the device’s function.
5. COMMISSIONING AND OPERATION OF THE
MIGHTY MEDIC VAPORIZER
5.1. Unpacking
The box contains all components as
well as the Instructions for Use. Keep
the Instructions for Use for future ref-
erence.
Remove the M IGHTY MEDIC Vapor-
izer and the accessories from the box.
Immediately after unpacking, check
whether the Vaporizer, the accessories, the power adapter and its device
plug are all included in the delivery
and work properly.
If you notice any defects, inform the
seller or the delivery agent immediate ly.
The packing material (plastic
bags, boxes etc.) must be
kept out of the reach of children as it is a potential source of danger.
Please dispose of the packing material in a proper and environmentally
friendly manner.
We recommend keeping the original
packaging in case it is required later
(transport, Service Centre, etc.).
5.2. Power Connection
Before connecting up the MI GHTY
MEDIC Vaporizer, make sure that the
information given on the power adapter type label corresponds to the local
power supply voltage.
All parts of the electrical system must
comply with currently applicable official regulations.
Place the heated Vaporizer only on a
hard, stable surface, and not on any
soft or heat-sensitive material.
Take care that the power adapter cord
cannot be damaged through kinking,
crushing or pulling.
Improper installation may
lead to personal injury or material damages, for which the
manufacturer cannot be held respon-
sible.
17 16