WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing
property damage, personal injury, or loss of life.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire
department.
— Installation and service must be performed by a quali-
fied installer, service agency, or the gas supplier.
This appliance may be installed in an aftermarket,* permanently located, manufactured
(mobile) home, where not prohibited by local codes.
WARNING: Improper installation,
adjustment, alteration, service,
or maintenance can cause injury
or property damage. Refer to this
manual for correct installation
and operational procedures. For
assistance or additional information consult a qualified installer, service agency, or the
gas supplier.
WARNING: This is an unvented
gas-fired heater. It uses air (oxygen) from the room in which it is
installed. Provisions for adequate
combustion and ventilation air
must be provided. Refer to
Combustion and Ventilation
tion on page 4 of this manual.
Air for
sec-
This appliance is only for use with the type of gas indicated on the rating plate. This
appliance is not convertible for use with other gases.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
Save this manual for future reference.
®
UNVENTED PROPANE/LP GAS FIREPLACE
SAFETY
INFORMATION
WARNINGS
IMPORTANT: Read this owner’s
manual carefully and completely
before trying to assemble, operate,
or service this fireplace. Improper
use of this fireplace can cause serious injury or death from burns, fire,
explosion, electrical shock, and
carbon monoxide poisoning.
DANGER: Carbon monoxide
poisoning may lead to death!
Carbon Monoxide Poisoning:Early signs
of carbon monoxide poisoning resemble the
flu, with headaches, dizziness, or nausea. If
you have these signs, the fireplace may not
be working properly. Get fresh air at once!
Have fireplace serviced. Some people are
more affected by carbon monoxide than
others. These include pregnant women,
people with heart or lung disease or anemia,
those under the influence of alcohol, and
those at high altitudes.
Propane/LP Gas: Propane/LP gas is odor-
less. An odor-making agent is added to the gas.
The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas
may be present even though no odor exists.
Make certain you read and understand all
warnings. Keep this manual for reference. It
is your guide to safe and proper operation of
this fireplace.
WARNING: Any change to
this heater or its controls can be
dangerous.
WARNING: Do not allow fans
to blow directly into the fireplace.
Avoid any drafts that alter burner
flame patterns. Ceiling fans can
create drafts that alter burner
flame patterns. Altered burner
patterns can cause sooting.
WARNING: Do not use a
blower insert, heat exchanger
insert, or other accessory not approved for use with this fireplace.
Due to high temperatures, the
appliance should be located out
of traffic and away from furniture
and draperies.
Do not place clothing or other
flammable material on or near
the appliance. Never place any
objects on the heater.
Fireplace front and screen become very hot when running fireplace. Keep children and adults
away from hot surfaces to avoid
burns or clothing ignition. Fireplace will remain hot for a time
after shutdown. Allow surfaces
to cool before touching.
Carefully supervise young children when they are in the room
with fireplace. When using the
hand-held remote accessory,
keep selector switch in the OFF
position to prevent children from
turning on burners with remote.
You must operate this fireplace
with the fireplace screen and
hood in place. Make sure fireplace screen and hood are in
place before running fireplace.
Keep the appliance area clear and
free from combustible materials,
gasoline, and other flammable
vapors and liquids.
1.This appliance is only for use with the
type of gas indicated on the rating plate.
This appliance is not convertible for use
with other gases.
2.Do not place propane/LP supply tank(s)
inside any structure. Locate propane/
LP supply tank(s) outdoors.
3.If you smell gas
• shut off gas supply
• do not try to light any appliance
•
do not touch any electrical switch; do
not use any phone in your building
• immediately call your gas supplier
from a neighbor’s phone. F ollow the
gas supplier’s instructions
• if you cannot reach your gas supplier,
call the fire department
4.This fireplace shall not be installed in
a bedroom or bathroom.
5.Do not use this fireplace as a woodburning fireplace. Use only the logs
provided with the fireplace.
6.Do not add extra logs or ornaments
such as pine cones, vermiculite, or rock
wool. Using these added items can
cause sooting. Do not add lava rock
around base. Rock and debris could fall
into the control area of fireplace.
7.This fireplace is designed to be smokeless. If logs ever appear to smoke, turn
off fireplace and call a qualified ser-
Note:
vice person.
eration, slight smoking could occur due
to log curing and fireplace burning
manufacturing residues.
8.To prevent the creation of soot, follow
the instructions in Cleaning and Main-tenance, page 18.
9.Before using furniture polish, wax, carpet cleaner, or similar products, turn
heater off. If heated, the vapors from
these products may create a white powder residue within burner box or on
adjacent walls or furniture.
10. This fireplace needs fresh air ventilation to run properly . This fireplace has
an Oxygen Depletion Sensing (ODS)
safety shutoff system. The ODS shuts
down the fireplace if not enough fresh
air is available. See Air for Combus-tion and Ventilation, pages 4 through
6. If fireplace keeps shutting off, see
Troubleshooting, pages 19 through 21.
11. Do not run fireplace
• where flammable liquids or vapors
are used or stored
• under dusty conditions
12. Do not use this fireplace to cook food
or burn paper or other objects.
13. Do not use fireplace if any part has been
exposed to or under water . Immediately
call a qualified service technician to
inspect the fireplace and to replace any
part of the control system and any gas
control which has been under water.
14. Do not operate fireplace if any log is
broken. Do not operate fireplace if a
log is chipped (dime-sized or larger).
15. Turn fireplace off and let cool before
servicing. Only a qualified service person should service and repair fireplace.
During initial op-
For more information, visit www.desatech.com
2
107156
OWNER’S MANUAL
SAFETY
INFORMATION
Continued
16. Operating fireplace above ele vations of
4,500 feet could cause pilot outage.
17. To prevent performance problems, do
not use propane/LP fuel tanks of less
than 100 lbs. capacity.
18. Provide adequate clearances around air
openings.
PRODUCT
IDENTIFICATION
Crossover
Middle Log
Front Log
Front
Burner
Figure 1 - Log Base Assembly, Split Oak Set
Top Louver
Assembly
Fireplace
Hood
Firebox Support
Log
Rear
Log
Rear
Burner
Top Outer
Casing
LOCAL CODES
Install and use fireplace with care. Follow all
local codes. In the absence of local codes, use
the latest edition of
Code ANSI Z223.1/NFPA 54*
*Available from:
American National Standards Institute, Inc.
New York, NY 10018
National Fire Protection Association, Inc.
Quincy, MA 02269
The National Fuel Gas
.
1430 Broadway
Batterymarch Park
UNPACKING
WARNING: Do not remove
the data plates attached to the
heater base assembly. The data
plates contain important warranty
information.
1.With utility knife, cut the carton all the
way around above the staples on the
bottom tray. Lift the carton off the
heater. Remove packing.
hood is located in the packing on the
right hand side of the heater front. Lift
the heater off the bottom tray.
2.Locate two screws above top corners
of the fireplace screen. Remove and
discard these screws. Lift fireplace
screen up and pull out to remove.
3.Remove protective packaging applied to
logs, log base assembly, and fireplace.
4.Remove fireplace hood from carton
insert.
5.Check all items for any shipping damage. If damaged, promptly inform
dealer where you bought fireplace.
Note:
The
Screen
Assembly
Figure 2 - Fireplace
107156
Optional Blower
Assembly
(Not Included)
Bottom
Louver
Assembly
3
For more information, visit www.desatech.com
®
UNVENTED PROPANE/LP GAS FIREPLACE
PRODUCT
FEATURES
OPERATION
This vent-free fireplace is clean burning. It
requires no outside venting. There is no heat
loss out a vent or up a chimney. Heat is
generated by both realistic flames and glowing embers. When used without the blower,
the fireplace requires no electricity making
it ideal for emergency backup heat.
SAFETY DEVICE
This fireplace has a pilot with an Oxygen
Depletion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for
vent-free room heaters. The ODS system shuts
off the fireplace if there is not enough fresh air.
PIEZO IGNITION SYSTEM
This fireplace has a piezo ignitor. This system requires no matches, batteries, or other
sources to light fireplace.
BLOWER ASSEMBLY
(VSGF28PTC)
This fireplace has a blower assembly. The
blower operates thermostatically and has a
variable speed control. The blower circulates
heated air from the fireplace into the room.
Use of blower is optional. Optional blower
accessories are available for model
VSGF28PVA.
THERMOSTAT CONTROL
(VSGF28PTC)
This f ireplace has a thermostat sensing bulb
and a control valve. The thermostat controls
the heat output and flame height. This maintains a consistent room temperature. Even the
lowest setting provides realistic flames and
glowing embers from two burners. Selecting
higher comfort settings allows fireplace to run
longer, producing greater heat output. At lower
comfort settings, the fireplace will run less.
This results in increased heating comfort. This
can also result in lower gas bills.
VARIABLE MANUAL
CONTROL (VSGF28PVA)
This fireplace has a variable manual control
valve which allows the user to choose the
heat setting that best suits his needs. Any
setting between low and high may be selected by simply turning the control knob.
AIR FOR
COMBUSTION AND
VENTILATION
WARNING: This heater shall
not be installed in a confined space
or unusually tight construction
unless provisions are provided
for adequate combustion and ventilation air. Read the following instructions to insure proper fresh
air for this and other fuel-burning
appliances in your home.
Today’s homes are built more energy efficient than ever. New materials, increased
insulation, and new construction methods
help reduce heat loss in homes. Home owners
weather strip and caulk around windows and
doors to keep the cold air out and the warm air
in. During heating months, home owners
want their homes as airtight as possible.
While it is good to make your home energy
efficient, your home needs to breathe. Fresh
air must enter your home. All fuel-burning
appliances need fresh air for proper combustion and ventilation.
Exhaust fans, fireplaces, clothes dryers, and
fuel burning appliances draw air from the
house to operate. You must provide adequate fresh air for these appliances. This
will insure proper venting of vented fuelburning appliances.
PROVIDING ADEQUATE
VENTILATION
The following are excerpts from National
Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation.
All spaces in homes fall into one of the three
following ventilation classifications:
1.Unusually Tight Construction
2.Unconfined Space
3.Confined Space
The information on pages 4 through 6 will
help you classify your space and provide
adequate ventilation.
Unusually Tight Construction
The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you
must provide additional fresh air.
Unusually tight construction is defined as construction where:
a. walls and ceilings exposed to the
outside atmosphere have a continuous water vapor retarder with
a rating of one perm (6 x 10
per pa-sec-m
ings gasketed or sealed
b. weather stripping has been
added on openable windows and
doors
c. caulking or sealants are applied
to areas such as joints around
window and door frames, between sole plates and floors, between wall-ceiling joints, between wall panels, at penetrations for plumbing, electrical, and
gas lines, and at other openings.
If your home meets all of the three
criteria above, you must provide additional fresh air. See
From Outdoors
If your home does not meet all of the
three criteria above, proceed to
mining Fresh-Air Flow for Fireplace
Location
and
on page 5.
2
) or less with open-
Ventilation Air
, page 6
.
and
Deter-
-11
kg
Confined Space and Unconfined
Space
The National Fuel Gas Code, ANSI
Z223.1/NFPA 54 defines a confined space
as a space whose volume is less than 50
cubic feet per 1,000 Btu per hour (4.8 m
per kw) of the aggregate input rating of
all appliances installed in that space and
an unconfined space as a space whose
volume is not less than 50 cubic feet per
1,000 Btu per hour (4.8 m3 per kw) of the
aggregate input rating of all appliances
installed in that space. Rooms communicating directly with the space in which
the appliances are installed*, through
openings not furnished with doors, are
considered a part of the unconfined space.
This heater shall not be installed in a confined space or unusually tight construction
unless provisions are provided for adequate
combustion and ventilation air.
* Adjoining rooms are communicating only
if there are doorless passageways or ventilation grills between them.
3
For more information, visit www.desatech.com
4
107156
OWNER’S MANUAL
AIR FOR
COMBUSTION AND
VENTILATION
Continued
DETERMINING FRESH-AIR FLOW FOR FIREPLACE LOCATION
Determining if You Have a Confined or Unconfined Space
Use this work sheet to determine if you have a confined or unconfined space.
Space: Includes the room in which you will install fireplace plus any adjoining rooms with doorless passageways or ventilation grills
between the rooms.
1.Determine the volume of the space (length x width x height).
Length x Width x Height = _________________cu. ft. (volume of space)
Example:
If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of
the space.
2.Multiply the space volume by 20 to determine the maximum Btu/Hr the space can support.
___________ (volume of space) x 20 = (Maximum Btu/Hr the space can support)
Example:
3.Add the Btu/Hr of all fuel burning appliances in the space.
Vent-free fireplace____________________ Btu/Hr
Gas water heater*____________________ Btu/Hr
Gas furnace____________________ Btu/Hr
Vented gas heater____________________ Btu/Hr
Gas fireplace logs____________________ Btu/Hr
Other gas appliances* +____________________ Btu/Hr
Total =____________________ Btu/Hr
* Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors.
4.Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.
_________ Btu/Hr (maximum the space can support)
_________ Btu/Hr (actual amount of Btu/Hr used)
Example:
The space in the above example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support.
You must provide additional fresh air. Your options are as follows:
A. Rework work sheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoin-
ing room or add ventilation grills between rooms. See Ventilation Air from Inside Building, page 6.
B. Vent room directly to the outdoors. See Ventilation Air from Outdoors, page 6.
C. Install a lower Btu/Hr fireplace, if lower Btu/Hr size makes room unconfined.
If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no
additional fresh air ventilation.
Space size 22 ft. (length) x 18 ft. (width) x 8 ft. (ceiling height) = 3168 cu. ft. (volume of space)
3168 cu. ft. (volume of space) x 20 = 63,360 (maximum Btu/Hr the space can suppor t)
Example:
Gas water heater
Vent-free fireplace+
Total=
63,300 Btu/Hr (maximum the space can support)
68,000 Btu/Hr (actual amount of Btu/Hr used)
40,000
28,000
68,000
Btu/Hr
Btu/Hr
Btu/Hr
WARNING: If the area in which the heater may be operated is smaller than that defined as an unconfined space
or if the building is of unusually tight construction, provide adequate combustion and ventilation air by one of
the methods described in the
107156
National Fuel Gas Code, ANSI Z223.1/NFPA 54 Section 5.3
5
For more information, visit www.desatech.com
or applicable local codes
Continued
.
®
UNVENTED PROPANE/LP GAS FIREPLACE
AIR FOR
COMBUSTION AND
VENTILATION
Continued
VENTILATION AIR
Ventilation Air From Inside
Building
This fresh air would come from an adjoining
unconfined space. When ventilating to an
adjoining unconfined space, you must provide two permanent openings: one within
12" of the ceiling and one within 12" of the
floor on the wall connecting the two spaces
(see options 1 and 2, Figure 3). You can also
remove door into adjoining room (see option 3, Figure 3). Follow the National Fuel
Gas Code, ANSI Z223.1/NFPA 54, Section
5.3, Air for Combustion and Ventilation for
required size of ventilation grills or ducts.
Ventilation Air From Outdoors
Provide extra fresh air by using ventilation
grills or ducts. You must provide two permanent openings: one within 12" of the
ceiling and one within 12" of the floor.
Connect these items directly to the outdoors
or spaces open to the outdoors. These spaces
include attics and crawl spaces. Follow the
National Fuel Gas Code, ANSI Z223.1/
NFPA 54, Section 5.3, Air for Combustion
and Ventilation for required size of ventila-
tion grills or ducts.
IMPORTANT:
inlet or outlet air into attic if attic has a
thermostat-controlled power vent. Heated air
entering the attic will activate the power vent.
Do not provide openings for
12"
Ventilation
Grills
Into Adjoining
Room,
Option 1
Figure 3 - Ventilation Air from Inside Building
Or
Remove
Door into
Adjoining
Room,
Option
3
12"
Outlet
Air
Ventilation Grills
Into Adjoining Room,
Option 2
Ventilated
Attic
Outlet
Air
Inlet
Air
Inlet Air
Figure 4 - Ventilation Air from Outdoors
Ventilated
Crawl Space
To Attic
To
Crawl
Space
For more information, visit www.desatech.com
6
107156
OWNER’S MANUAL
INSTALLATION
NOTICE: This heater is intended
for use as supplemental heat.
Use this heater along with your
primary heating system. Do not
install this heater as your primary heat source. If you have a
central heating system, you may
run system’s circulating blower
while using heater. This will help
circulate the heat throughout the
house. In the event of a power
outage, you can use this heater
as your primary heat source.
WARNING: A qualified service person must install fireplace.
Follow all local codes.
WARNING: Never install the
fireplace
• in a bedroom or bathroom
• in a recreational vehicle
• where curtains, furniture,
clothing, or other flammable
objects are less than 42 inches
from the front, top, or sides of
the fireplace
• in high traffic areas
• in windy or drafty areas
WARNING: Models VSGF28PTC
have a three-prong, grounded
electrical plug. This plug helps
protect you against electrical
shock. Only connect plug to a
properly grounded, three-prong
receptacle. Do not cut or remove
the grounding prong from this
plug.
CAUTION: This fireplace creates warm air currents. These currents move heat to wall surfaces
next to fireplace. Installing fireplace next to vinyl or cloth wall
coverings or operating heater
where impurities (such as, but
not limited to, tobacco smoke,
aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in
the air exist, may discolor walls
or cause odors.
Note:
Your fireplace is designed to be used
in zero clearance installations. Wall or framing material can be placed directly against
any exterior surface on the rear, sides, or top
of your fireplace, except where standoff
spacers are integrally attached. If standoff
spacers are attached to your fireplace, these
spacers can be placed directly against wall
or framing materials.
Use the dimensions shown for rough openings
to create the easiest installation (see Built-InFireplace Installation, pages 9 and 10).
IMPORTANT:
ture to the air. Although this is beneficial,
installing fireplace in rooms without enough
ventilation air may cause mildew to form
from too much moisture. See Air for Com-bustion and Ventilation, pages 4 through 6.
IMPORTANT:
level. If fireplace is not level, log set will not
work properly.
Vent-free heaters add mois-
Make sure the fireplace is
CHECK GAS TYPE
Use only propane/LP gas. If your gas supply
is not propane/LP gas, do not install fireplace. Call dealer where you bought fireplace for proper type fireplace.
ELECTRICAL HOOKUP
(Model VSGF28PTC or
VSGF28PVA with GA3750 or
GA3650T Series Blower)
This fireplace has a blower assembly with an
electrical cord. The electrical cord is five feet
in length. You must locate fireplace within
reach of a 120-volt grounded electrical outlet. If not, you must install an electrical outlet
within reach of fireplace power cord.
GA3555 outlet accessory may be used for
built-in installation when a blower is installed. This same information applies if
installing optional blower accessories to
Model VSGF28PVA.
The
INSTALLING HOOD
Install hood to rail already installed in fireplace as shown in Figure 5. Use 3 Phillips
screws provided.
Hood
Rail
Screw
Figure 5 - Installing Hood
107156
Continued
7
For more information, visit www.desatech.com
®
UNVENTED PROPANE/LP GAS FIREPLACE
INSTALLATION
Continued
ASSEMBLING AND
ATTACHING OPTIONAL
BRASS TRIM
(Included with Mantel
Accessory)
IMPORTANT:
in a wall, do not attach brass trim at this time.
See page 9 for built-in fireplace installation.
Note:
The instructions below show assem-
bling and attaching brass trim to fireplace.
1.Remove packaging from three pieces
of brass trim.
2.Locate four brass screws, two adjusting plates with set screws, and two
shims in the hardware packet.
3. Align shim under adjusting plate as
shown in Figure 6.
4.Slide one end of adjusting plate/shim
in slot on mitered edge of top brass trim
(see Figure 6).
5.Slide other end of adjusting plate/shim
in slot on mitered edge of side brass
trim (see Figure 6).
6. While firmly holding edges of brass
trim together, tighten both set screws
on the adjusting plate with slotted
screwdriver.
7.Repeat steps 1 through 6 for other side.
8. Tighten trim hanging screws (#10 x
6.25 shoulder) into holes in cabinets.
Place the assembled trim onto fireplace
cabinet. Align hanging notches on trim
with hanging screws on side of fireplace (see Figure 7). Push trim firmly
into place, sliding hanging notches over
hanging screws.
Side Brass
Trim
Slot
Figure 6 - Assembling Brass Trim
If you are recessing the firebox
Set Screws
Adjusting
Plate
Shim
Mitered Edge
Top
Brass
Trim
Slot
Trim
Hanging
Screws
Hanging
Notches
on Trim
Assembled
Brass Trim
Figure 7 - Attaching Brass Trim to
Fireplace
INSTALLATION
CLEARANCES
WARNING: Maintain the minimum clearances. If you can, provide greater clearances from
floor, ceiling, and adjoining wall.
Carefully follow the instructions below. This
will ensure safe installation.
Minimum Clearances For Side
Combustible Material, Side Wall,
and Ceiling
A. Clearances from the side of the fireplace
cabinet to any combustible material and
wall should follow diagram in Figure 8.
Example:
etc. is made of combustible material and
protrudes 3 1/2" from the wall. This combustible material must be 4" from the side
of the fireplace opening (see Figure 8).
B. Clearances from the top of the fireplace
opening to the ceiling should not be less
than 42 inches.
FIREBOX
*Minimum 16 inches from Side Wall
Figure 8 - Minimum Clearance for
Combustible to Wall
The face of a mantel, bookshelf,
Example
.52
14 6 8 10 12 14 16
INCHES
121/
101/
8
7
51/
31/
3
1
7/8
7/16
*
4
2
3
/
4
4
2
/
4
CONVENTIONAL FIREPLACE
INSTALLATION
Conventional installation of this fireplace
involves installing fireplace along with the
corner or cabinet mantel with hearth base
accessories against a wall in your home (see
Accessories, page 22 and 23). Follow the
instructions below to install the fireplace in
this manner.
Note:
The instructions below show installation using the cabinet mantel and the
G3000F/G3001U/G3004W/G3006F/
G3007U series hearth base accessories. The
hearth base accessory shown is optional for
this installation. You can install fireplace
and cabinet/corner mantel directly on the
floor. The corner mantel accessory cannot
be installed with the G3000F/G3001U/
G3004W/G3006F/G3007U hearth base. The
corner mantel can be paired with the G3008F/
G3009U/G3010F corner hearth base. If
mounting fireplace and cabinet or corner
mantel to the floor, an optional G3005 Slim
Base kit may be installed.
1.Assemble cabinet mantel, hearth base,
and trim accessories. Assembly instructions are included with each accessory .
2.When installing blower , install a prop-
erly grounded, 120 volt three-prong
electrical outlet at fireplace location if
an outlet is not there. If possible, locate outlet so cabinet mantel will cover
it when installed (see Figure 9).
3.Install gas piping to fireplace location.
This installation includes an approved
flexible gas line (if allowed by local
codes) after the equipment shutoff
valve. The fle xible gas line must be the
last item installed on the gas piping. See
Installing Gas Piping to Fireplace Location, pages 10 and 11.
Rigid Pipe and
Gas Shutoff Valve
Hearth
Base
INCHES
Figure 9 - Placing Hearth Base Accessory
Against Wall
Electrical Outlet
Gas Line
Access
Hole
For more information, visit www.desatech.com
8
107156
OWNER’S MANUAL
INSTALLATION
Continued
4. Place hearth base accessory against
wall at installation location. Cut an access hole in hearth top to run gas line
to fireplace (see Figure 9, page 8).
Make sure to locate access hole so cabinet mantel will cover it when installed.
Note:
You can secure base to floor using wood screws. Countersink screw
heads and putty over.
5.Route gas line through access hole in
hearth base.
6.Center cabinet mantel on hearth base
(see Figure 10). Make sure mantel is
flush against wall.
7.Break off nailing flanges (see Figure
11) with hammer or pliers.
8. Place cardboard or other protective
material on top of hearth base. Carefully set fireplace on protective material, with back of fireplace inside mantel opening.
9.If blower is installed, route blower electrical cord through access holes in either side of fireplace.
may be moved if necessary. Plug electrical cord into electrical outlet.
Note:
Bushing
Cabinet
Mantel
10. Carefully insert fireplace into cabinet
mantel (Figure 12). Be careful not to
scratch or damage hearth base, cabinet
mantel, or any laminate trim on hearth
base. Remove protective material from
top of hearth base and from front of
fireplace (if any).
Note:
You can secure fireplace to hearth or floor. Open
lower louver. Locate screw holes in
bottom of base. Tighten wood screws
through these holes and into hearth or
floor.
11. Attach gas line from fireplace gas regulator to gas supply . See Connecting Fir e-place to Gas Supply, pa g e 11.
12. Check all gas connections for leaks. See
Checking Gas Connections, page 12.
Nailing
Flanges
Figure 11 - Location of Nailing Flanges
BUILT-IN FIREPLACE
INSTALLATION
Built-in installation of this fireplace involves
installing fireplace into a framed-in enclosure. This makes the front of fireplace flush
with wall. If installing a mantel above the
fireplace, you must follow the clearances
shown in Figure 16, page 10 . Follow the
instructions below to install the fireplace in
this manner.
ActualFraming
Height32
Front Width 34
Depth16
1.Frame in rough opening. Use dimensions shown in Figure 13 for the rough
opening.
If installing in a corner, use dimensions shown in Figure 14, page 10 for
the rough opening. The height is 33"
which is the same as the wall opening
above.
2.If using blower, install and properly
ground GA3555, three-prong 120 volt
electrical outlet, in fireplace. Follow
instructions included in kit.
3.Install gas piping into fireplace location. This installation includes an approved flexible gas line (if allowed by
local codes) after the equipment shutoff
valve. The flexib le gas line must be the
last item installed on the gas piping. See
Installing Gas Piping to Fir eplace Location, pages 10 and 11.
3
/8"33"
5
/16"35 1/2"
11
/16"17 3/4"
Figure 10 - Installing Cabinet Mantel
107156
Figure 12 - Inserting Fireplace Into Cabinet
Mantel
9
For more information, visit www.desatech.com
17 3/4"
33"
35 1/2"
Figure 13 - Rough Opening for Installing
in Wall
Continued
®
UNVENTED PROPANE/LP GAS FIREPLACE
INSTALLATION
Continued
4.Carefully set fireplace in front of rough
opening with back of fireplace inside
wall opening.
5.Plug electrical cord into electrical outlet installed in step 2, page 9.
6. Carefully insert fireplace into rough
opening.
7.Attach flexible gas line to gas supply.
See Connecting Fireplace to Gas Sup-ply, page 11.
8. Attach fireplace to wall studs using
nails or wood screws through holes in
nailing flange (see Figure 15).
9.Check all gas connections for leaks. See
Checking Gas Connections, page 12.
10. Install brass trim after final finishing
and/or painting of wall (see Figure 7,
page 8).
39 3/8"
27 7/8"
35 1/2"
55 5/8"
Figure 14 - Rough Opening for Installing
in Corner
Nails or
Wood
Screws
Mantel Clearances for Built-In
Installation
If placing mantel above built-in fireplace,
you must meet minimum clearance between
mantel shelf and top of fireplace opening.
If your installation does not meet the below
minimum clearances, you must:
• raise the mantel to an acceptable height,
OR
• remove the mantel.
Mantel
13"
16"
Shelf
19"
21"
Note:
All Vertical
measurements
are from top of
fireplace
opening to
bottom of
mantel shelf.
Figure 16 - Minimum Mantel Clearances
for Built-In Installation
10"
8"
6"
2
1
/2
"
INSTALLING GAS PIPING TO
FIREPLACE LOCATION
WARNING: This appliance requires a 1/2" NPT (National Pipe
Thread) inlet connection to the
pressure regulator.
Installation Items Needed
Before installing fireplace, make sure you
have the items listed below.
• external regulator (supplied by installer)
• piping (check local codes)
• sealant (resistant to propane/LP gas)
• equipment shutoff valve *
• test gauge connection *
• sediment trap (optional)
• tee joint
• pipe wrench
* A CSA design-certified equipment shutoff
valve with 1/8" NPT tap is an acceptable
alternative to test gauge connection. Purchase the optional CSA design-certified
equipment shutoff valve from your dealer.
See Accessories, pages 22 and 23.
The installer must supply an external regulator. The external regulator will reduce
incoming gas pressure. You must reduce
incoming gas pressure to between 11 and 14
inches of water. If you do not reduce incoming gas pressure, heater regulator damage
could occur. Install external regulator with
the vent pointing down as shown in Figure
17. Pointing the vent down protects it from
freezing rain or sleet.
CAUTION: Use only new,
black iron or steel pipe. Internally-tinned copper tubing may
be used in certain areas. Check
your local codes. Use pipe of 1/2"
diameter or greater to allow
proper gas volume to fireplace. If
pipe is too small, undue loss of
volume will occur.
vice person must connect fire-
Nailing
Flanges
Figure 15 - Attaching Fireplace to Wall
Studs
place to gas supply. Follow all
local codes.
heater directly to the propane/LP
supply. This heater requires an external regulator (not supplied). Install the external regulator between
the heater and propane/LP supply.
For more information, visit www.desatech.com
WARNING: A qualified ser-
CAUTION: Never connect
10
Propane/LP
Supply
External
Regulator
Vent
Pointing
Down
Figure 17 - External Regulator with Vent
Pointing Down
Tank
107156