Vanguard Heating NLFB32NC, FB32CA, FB32NCA, NLFB32C User Manual

UNVENTED (VENT-FREE) 32” LogMate® UNIVERSAL FireBOX
®
OWNER’S MANUAL
Shown with optional cabinet
mantel, hearth base, brass trim,
and marble trim accessories.
FB32CA (SHOWN) AND NLFB32C CIRCULATING
LOUVERED;
FB32NCA AND NLFB32NC NONCIRCULATING SMOOTH
FACE MODELS
WARNING: If the information in this manual is not fol­lowed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life.
WARNING: For use only with a listed gas-fired unvented decorative room heater. Not to exceed 40,000 Btu/Hr. Do not build a wood fire.
Carefully review the instructions supplied with the decorative type unvented room heater for the minimum fireplace size requirement.
Do not install an appliance in this firebox unless this firebox meets the minimum dimensions required for the installation.
This firebox has been tested and approved by CSA under ANSI Z21.91 for use with any ANSI Z21.11.2 ap­proved gas logs.
Save this manual for future reference.
For more information, visit www.desatech.com
WARNING: Improper installation, adjustment, altera­tion, service, or maintenance can cause injury or prop­erty damage. Refer to this manual for correct installation and operational procedures. For assistance or addi­tional information consult a qualified installer, service agency, or the gas supplier.
This appliance may be installed in an aftermarket,* per­manently located, manufactured (mobile) home, where not prohibited by local codes.
This appliance is only for use with the type of gas indi­cated on the rating plate. This appliance is not convert­ible for use with other gases.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
TABLE OF CONTENTS
Safety Information ............................................... 3
Local Codes ........................................................ 4
Unpacking ........................................................... 4
Product Specifications ......................................... 4
Product Features ................................................. 5
Locating Firebox ................................................. 5
Air for Combustion and Ventilation ...................... 6
Installation ........................................................... 8
Replacement Parts ............................................ 15
Technical Service .............................................. 15
Accessories ....................................................... 16
Illustrated Parts Breakdown and Parts List ....... 18
Warranty Information ...........................Back Cover
www.desatech.com
105604-01H2

SAFETY INFORMATION

WARNING: This product con­tains and/or generates chemicals known to the State of California to cause cancer or birth defects, or other reproductive harm.
IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, operate, or service this firebox. Improper use of this firebox can cause seri­ous injury or deatah from burns, fire, explosion, electrical shock, or carbon monoxide poisoning.
WARNING: Any change to this firebox or its controls can be dangerous.
WARNING: Do not allow fans to blow directly into the firebox. Avoid any drafts that alter burner flame patterns. Ceiling fans can create drafts that alter burner flame patterns. Altered burner patterns can cause sooting.
Do not place clothing or other flammable material on or near firebox. Never place any objects on the firebox or logs.
Carefully supervise young chil dren when they are in the room with firebox.
Firebox front and screen become very hot when running firebox. Keep children and adults away from hot surfaces to avoid burns or clothing ignition. Firebox will remain hot for a time after shut­down. Allow surfaces to cool before touching.
You must operate this fireplace with the provided fireplace screen (closed) and hood in place. Make sure these parts are in place before running firebox. This firebox has been tested and approved with and without the brick liner. If the liner is removed, the model number reverts to the NL (non-lined) series.
-
WARNING: Do not use a blow­er insert, hood, heat exchanger insert, or other accessory not ap­proved for use with this heater. Do not use blower accessory with Models NLFB32NC and FB32NCA. Use only the provided hood or GA6096 polished brass hood accessory (see Accesso- ries on page 16).
Due to high temperatures, the firebox should be located out of traffic and away from furniture and draperies.
105604-01H 3
www.desatech.com
Keep the firebox area clear and free from combustible materials, gasoline, and other flammable vapors and liquids.
1. This firebox shall not be installed in a bedroom or bathroom.
2. Never install the firebox
• in a recreational vehicle
• where curtains, furniture, clothing, or other flammable objects are less than 42 inches from the front, top, or sides of the firebox
• in high traffic areas
• in windy or drafty areas
3. Do not use this firebox as a wood-burning fireplace. Use only decorative unvented room heaters (log sets).
4. Do not add extra logs or ornaments such as pine cones, vermiculite, or rock wool. Using these added items can cause sooting.
SAFETY INFORMATION
351/16"
313/4"
161/4"
11/4"
23/4"
23/4"
63/8"
193/8"
37/8"
63/4"
Continued
5. Vent-free gas log heaters installed in these fireboxes require fresh air ventilation to run properly. See Air for Combustion and Ventila- tion, page 6.
6. Do not run firebox
• where flammable liquids or vapors are used or stored
• under dusty conditions
7. Do not use this firebox to cook food or burn paper or other objects.
8. Turn firebox off and let cool before servicing. Only a qualified service person should service and repair firebox.
9.
Operating vent-free log sets in a firebox above elevations of 4,500 feet could cause pilot outage.
10. Do not use the firebox if it has been under water due to the shock hazard that could result with the blower accessary (if installed) in place.
Provide adequate clearances around air
11. openings.

LOCAL CODES

Install and use fireplace with care. Follow all local codes. In the absence of local codes, use the latest edi tion of The National Fuel Gas Code ANSI Z223.1/ NFPA 54*. Firebox must be electrically grounded in accordance with the National Electrical Code,
ANSI/NFPA70
(latest edition).
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269

UNPACKING

1. With utility knife, cut the carton all the way around above the staples on the bottom tray. Lift the carton off the firebox. Remove pack ing. Note: The hood is located in the packing on the right hand side of the heater front. Lift the heater off the bottom tray.
2. Check carton contents for the following:
• Screen assembly (2)
• Screen support rod (2)
• Hood
• Hardware and parts bag containing the following:
• Ownerʼs Operation and Installation
Manual
• 2 - Black #10 x 3/8” Phillips screws
• 3 - Zinc #10 x 1/2” shouldered hex
screws
• 2 - Black #10 x 5/8” shouldered hex
screws
If any items are missing, inform dealer where
you bought the firebox.
3. Check all items for any shipping damage. If damaged, promptly inform dealer where you bought firebox.
PRODUCT
SPECIFICATIONS
Built-in Nailing Flanges
-
Louvers (Models FB32CA and NLFB32C only)
Figure 1 - Firebox Front View
-
Standoffs (Models FB32NCA and NLFB32NC only)
www.desatech.com
105604-01H4
121/2"
23/4"
11/2"
93/4"
45/8"
21/2"
6"
323/16"
3311/16"
221/2"
1611/16"
131/4"
*
141/4"
*
315/8"
343/8"
355/8"
191/4"
PRODUCT
SPECIFICATIONS
Continued
Standoffs (Models FB32NCA and NLFB32NC only)
Electrical Access Hole
Figure 2 - Firebox Side View
Electrical Access Hole with Bushing
Gas Line Access

PRODUCT FEATURES

OPERATION
This firebox is designed for use with approved ANSI Z21.1.2 decorative type unvented room heaters. (Physical size limitations apply. Refer to minimum firebox requirements supplied with log heater.) It requires no outside venting or chimney making installation easy and inexpensive. When used without the blower (models FB32CA and NLFB32C only), the firebox requires no electricity making it ideal for emergency backup heat.
BLOWER ACCESSORY
The FB32CA and NLFB32C firebox will accept the GA3700 accessory. The variable blower allows you to select the fan speed you desire. The blower circulates heated air from the firebox into the room. Use of blower is optional.

LOCATING FIREBOX

Plan where you will install the firebox. This will save time and money later when you install the fire­box. Before installation, consider the following:
1. Where the firebox will be located. Allow for wall and ceiling clearances (see Clearances, page 9).
2. Everything needed to complete installation.
3. These models CANNOT be installed in a bedroom or bathroom.
4. Proper air for combustion and ventilation (see page 6).
Installation
1
*Note: 14 including brick liner. 13 floor including brick liner.
105604-01H 5
4
/
" is total firebox cavity depth
1
4
/
" is depth of flat
Figure 3 - Firebox Top View
www.desatech.com
AIR FOR COMBUSTION
AND VENTILATION
WARNING: This firebox shall not be installed in a confined space or unusually tight construc­tion unless provisions are provid­ed for adequate combustion and ventilation air. Read the following instructions to insure proper fresh air for this and other fuel-burning appliances in your home.
Todayʼs homes are built more energy efficient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible.
While it is good to make your home energy effi cient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper combustion and ventilation.
Exhaust fans, fireboxes, clothes dryers, and fuel burning appliances draw air from the house to operate. You must provide adequate fresh air for these appliances. This will insure proper venting of vented fuel-burning appliances.
PROVIDING ADEQUATE VENTILATION
The following are excerpts from National Fuel Gas Code ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation.
All spaces in homes fall into one of the three fol lowing ventilation classifications:
1. Unusually Tight Construction
2. Unconfined Space
3. Confined Space
The information on pages 6 through 8 will help you classify your space and provide adequate ventilation.
Unusually Tight Construction
The air that leaks around doors and windows may provide enough fresh air for combustion and ventila tion. However, in buildings of unusually tight con­struction, you must provide additional fresh air.
Unusually tight construction is defined as construction where:
a. walls and ceilings exposed to the out
side atmosphere have a continuous water vapor retarder with a rating of one perm (6x10 less with openings gasketed or sealed and
b. weather stripping has been added on
openable windows and doors and
c. caulking or sealants are applied to
areas such as joints around window and door frames, between sole plates and floors, between wall-ceiling joints, between wall panels, at penetrations for plumbing, electrical, and gas lines, and at other openings.
If your home meets all of the three criteria above, you must provide additional fresh air. See Ventilation Air From Outdoors, page 8.
If your home does not meet all of the
-
three criteria above, proceed to Determin­ing Fresh-Air Flow For Firebox Location,
page 7.
Confined Space and Unconfined Space
The National Fuel Gas Code ANSI Z223.1/NFPA 54 defines a confined space as a space whose
volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms com­municating directly with the space in which the
-
appliances are installed*, through openings not furnished with doors, are considered a part of the unconfined space.
* Adjoining rooms are communicating only if there are doorless passageways or ventilation grills between them.
-
-11
kg per pa-sec-m2) or
-
www.desatech.com
105604-01H6
AIR FOR COMBUSTION
AND VENTILATION
Continued
DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION
Determining if You Have a Confined or Unconfined Space
Use this work sheet to determine if you have a confined or unconfined space.
Space: Includes the room in which you will install
heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms.
1. Determine the volume of the space (length x width x height).
Length x Width x Height =__________ cu. ft.
(volume of space)
Example: Space size 20 ft. (length) x 16 ft.
(width) x 8 ft. (ceiling height) = 2560 cu. ft. (volume of space)
If additional ventilation to adjoining room is sup­plied with grills or openings, add the volume of these rooms to the total volume of the space.
2. Multiply the space volume by 20 to determine the maximum Btu/Hr the space can support.
____________ (volume of space) x 20 =
(Maximum Btu/Hr the space can support) Example: 2560 cu. ft. (volume of space) x 20 =
51,200 (maximum Btu/Hr the space can support)
3. Add the Btu/Hr of all fuel burning appliances in the space.
Vent-free heater ________
Gas water heater* ________
Gas furnace ________
Vented gas heater ________
Gas fireplace logs ________
Other gas appliances* + ________
Total = ________
* Do not include direct-vent gas appliances.
Direct-vent draws combustion air from the outdoors and vents to the outdoors.
Example:
Gas water heater ________
Vent-free heater + ________
Total = ________
40,000
39,000
79,000
Btu/Hr
Btu/Hr
Btu/Hr
Btu/Hr
Btu/Hr
Btu/Hr
Btu/Hr
Btu/Hr
Btu/Hr
Btu/Hr
4.
Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.
_______Btu/Hr (maximum the space
can support)
________ Btu/Hr (actual amount of
Btu/Hr used) Example: 51 ,2 00 Btu/Hr (maximum the
space can support)
79,000 Btu/Hr (actual amount of
Btu/Hr used)
The space in the above example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows:
A.
Rew ork worksh eet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoining room or add ventilation grills between rooms. See
Ventilation Air From Inside Building
B. Vent room directly to the outdoors. See Ven-
tilation Air From Outdoors
C. Install a lower Btu/Hr heater, if lower Btu/Hr size
makes room unconfined.
If the actual Btu/Hr used is less than the maxi­mum Btu/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.
, page 8.
, page 8
.
WARNING: If the area in which the firebox and gas log heater may be operat ed is smaller than that defined as an unconfined space or if the building is of unusually tight construction, provide adequate combustion and ventilation air by one of the methods described in the National Fuel Gas Code, ANSI Z223.1/NFPA 54 Section 5.3 or applicable local codes.
105604-01H 7
www.desatech.com
Or
Remove
Door into
Adjoining
Room, Option
3
Ventilation Grills
Into Adjoining Room,
Option
2
Ventilation
Grills
Into Adjoining
Room,
Option 1
12"
12"
Outlet Air
Ve
ntilated
Attic
Outlet
A
ir
Inlet Air
Inlet Air
Ventilated
Crawl Space
To
Crawl
Space
To Attic
AIR FOR COMBUSTION
AND VENTILATION
Continued
VENTILATION AIR
Ventilation Air From Inside Building
This fresh air would come from an adjoining un confined space. When ventilating to an adjoining unconfined space, you must provide two perma­nent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 4). You can also remove door into adjoining room (see option 3, Figure 4). Follow the National Fuel Gas
Code ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation for required size of
ventilation grills or ducts.
Figure 4 - Ventilation Air from Inside
Ventilation Air From Outdoors
Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the
National Fuel Gas Code ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation for
required size of ventilation grills or ducts.
Figure 5 - Ventilation Air from Outdoors
Building
www.desatech.com
IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a thermostat­controlled power vent. Heated air entering the attic will activate the power vent.

INSTALLATION

-
NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your primary heating system. Do not install this heater as your pri­mary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.
WARNING: A qualified ser­vice person must install firebox. Follow all local codes.
WARNING: Never install the firebox
• in a bedroom or bathroom
• in a recreational vehicle
• where curtains, furniture,
clothing, or other flammable objects are less than 42 inches from the front, top, or sides of the firebox
• in high traffic areas
• in windy or drafty areas
WARNING: Never install the firebox
• in a bedroom or bathroom
• in a recreational vehicle
• where curtains, furniture,
clothing, or other flammable objects are less than 42 inches from the front, top, or sides of the firebox
• in high traffic areas
• in windy or drafty areas
105604-01H8
INSTALLATION
Supplied Fire
box Hood Must Be Used at All Times
Wire-mesh Screen
Fire
box
Mantel Shelf
13"
16"
19"
21"
19" 20" 21" 22"
For FB32NCA and NLFB32NC Series noncirculating smooth face models
2
1
/2
"
6"
8"
10"
For FB32CA and NLFB32C Series circulating louvered models only
Continued
IMPORTANT: Vent-free gas log heaters add moisture to the air. Although this is beneficial, installing firebox in roo ms with ou t enough ventilation air may cause mildew to form from too much moisture. See Air for Combustion and Ventilation, page 6.
IMPORTANT: Make sure the firebox is level. If firebox is not level, log set will not work
*Minimum 16 inches from Side Wall
properly. Note: Your Vanguard firebox is designed to be
used in zero clearance installations. Wall or fram ing material can be placed directly against any exterior surface on the rear, sides, or top of your firebox, except where standoff spacers are inte grally attached. If standoff spacers are attached to your firebox, these spacers can be placed directly against wall or framing materials.
Use the dimensions shown for rough openings to create the easiest installation (see Built-In Firebox Installation, page 14).
-
Mantel Clearances for Built-In Installation
If placing custom mantel above built-in firebox,
­you must meet the minimum allowable clearance
between mantel shelf and top of firebox opening shown in Figure 8. These are the minimum allowable mantel clearances for a safe installation. Use larger clearances wherever possible to minimize the heating of objects and materials placed on the mantel.
INSTALLATION CLEARANCES
WARNING: Maintain the minimum clearances. If you can, provide greater clearances from floor, ceiling, and adjoining wall.
Carefully follow the instructions below. This will ensure safe installation.
Minimum Clearances For Side Combustible Material, Side Wall, and Ceiling
A. Clearances from the side of the fireplace
cabinet to any combustible material and wall should follow diagram in Figure 6.
Example: The face of a mantel, bookshelf,
etc. is made of combustible material and protrudes 3 1/2" from the wall. This combus­tible material must be 4" from the side of the fireplace opening (see Figure 6).
B.
Clearances from the top of the fireplace opening to the ceiling should not be less than 42 inches.
105604-01H 9
MINIMUM CLEARANCE TO
COMBUSTIBLE MATERIALS
Top Left and Bottom Right Sides and Rear
42" 16" 0"
www.desatech.com
before operation of vent-free gas log heater. Do not allow the heater to touch or extend beyond the fireplace screen.
If your installation does not meet the minimum clearances in Figure 8, you must:
• raise the mantel to an acceptable height,
OR • remove the mantel.
Note: All vertical measurements are from top of fireplace opening to bottom of mantel shelf. All measurements are in inches. Facing material (above firebox) may be of combustible material, including decorative mantel ornaments.
Figure 7 - Minimum Mantel Clearances
Example
Figure 6 - Minimum Clearance for
Combustible to Wall
CAUTION: Close screens
for Built-In Installation
*
For FB32NCA and NLFB32NC Series noncirculating, smooth face models
For FB32CA and NLFB32C Series circulating, louvered models only
INSTALLATION
Continued
INSTALLING BLOWER ACCESSORY
(Model FB32CA only)
You may install blower accessory GA3700 with conventional installation (below) or with built-in installation (page 11) with models FB32CA and NLFB32C only.
Conventional Installation of Blower Accessory
NOTICE: If a log set is currently installed in the firebox, disconnect log set from gas supply and remove from firebox. Contact a qualified service person to do this.
1. Remove the firebox bottom:
a. Remove the 4 screws that secure the bottom
of the firebox (see Figure 8).
b. Carefully raise and remove the firebox
bottom from the firebox.
WARNING: If there is a duplex electrical outlet installed in the right side of the bottom of the fireplace base area, be sure that the electrical power to the outlet is turned off before proceeding with blower installation. Failure to do this may result in serious injury.
2. Place the blower against lower rear wall of firebox wrapper with the exhaust port directed upward. Align the holes in top mounting tabs of blower with holes in wall of wrapper (see Figure 9). Using 2 screws provided, mount blower and tighten screws securely.
3.
Be certain that all wire terminals are securely at­tached to terminals on blower motor and that the screw retaining the green ground wire is tight.
4. Locate the plastic hole plug installed in the 3/8" diameter opening in the lower right side of the firebox front panel (see Figure 9). Remove the plastic plug and discard.
5. Place speed control against inner wall of front panel, pushing the plastic control shaft for ward through the opening (see Figure 10).
6. While supporting speed control, secure control shaft with lock nut by pushing and turning lock nut with pliers clockwise until it is tight against front panel. Place control knob pro vided on shaft (see Figure 10).
Lower Rear Wall of Firebox Wrapper
Blower
Screws
Exhaust Port
Figure 9 - Mounting Blower to Firebox
Floor Supports
Plastic Hole Plug
Top Mounting Tab
-
-
Screws
Figure 8 - Removing Screws from
Firebox Bottom
www.desatech.com
Speed Control
Control Knob
Figure 10 - Attaching Speed Control
Control Shaft
Lock Nut
105604-01H10
INSTALLATION
Continued
7. Plug in blower power cord.
a. If your firebox is installed as a freestanding
unit, determine whether the power cord will exit the left side or the right side of the firebox. Install 1 plastic bushing provided into the 1 the exit side. Install the second plastic bushing provided into the 1 outer casing through which the power cord will exit (see Figure 11). Route power cord through both plastic bushings and plug the power cord into a 3-prong grounded wall receptacle near the firebox.
b. If your firebox installation is recessed
and/or pre-wired, see Built-In Installation
of Blower Accessory
8. Turn on power to duplex outlet if previously turned off per the warning in step 1.
9.
Check to make sure that the power cord is com­pletely clear of the blower wheel and that there are no other foreign objects in blower wheel. Turn blower on and check for operation.
WARNING: Never touch the
blower wheel while in operation.
10. Peel off the backing paper and stick the sup­plied wiring diagram decal on the firebox bottom approximately 12" in front of the blower.
11. Replace bottom of firebox. the back of the firebox bottom slides under the rear of the firebrick (lift the firebrick up if necessary.)
12. Reattach firebox bottom using 4 screws re moved in step 1. Note: Discard the remaining hardware items.
13. Install the log set heater according to the instal lation instructions supplied with the heater.
Figure 11 - Installing Plastic Bushing for
1
/2" hole in the floor support on
1
/2" hole in the
, column 2.
Note: Make sure
Plastic Bushing
Power Cord
NOTICE: A qualified electrician must connect electrical wiring to duplex outlet for built-in instal­lation. Follow all local codes. In absence of local codes follow
The National Electrical Code ANSI/NFPA 70.
Built-In Installation of Blower Accessory
1. Before replacing bottom of firebox, remove screw holding duplex outlet to the support bracket in the bottom of firebox. Remove duplex outlet.
2. Clamp electrical cable into firebox through smallest hole in outer casing using strain relief provided.
3. Route wires from electrical box through hole in side of heater and hole in support bracket (see Figure 12).
4. Connect wires from the electrical box to duplex outlet. Match wire colors to those indicated on duplex outlet. Be sure to connect ground wire.
5. Replace duplex outlet with screw.
6. Plug blower power cord into duplex outlet.
7. Replace bottom of firebox.
Cables From
Support Bracket
Blower
-
-
Figure 12 - Routing Blower Accessory
Power Cord for Built-In Installation
Operating the Blower
Light your gas appliance with the blower off. After about 15 minutes, turn the blower on to deliver heated air at the top louvers. The blower features a variable control which allows you to select the speed you desire.
Note: Periodically check the louvers of the firebox and remove any dust, dirt, or other obstructions.
Electrical Source
Blower Power Cord
Screw
Duplex Outlet
105604-01H 11
www.desatech.com
INSTALLATION
Cut to
7 1/4"
Length
Continued
INSTALLING LOG HEATER IN FIREBOX
CAUTION: Do not remove the data plates attached to the heater base assembly. The data plates contain important warranty and safety information.
CAUTION: Do not pick up log base assembly by burners. This could damage burners. Only handle base by grates.
1. Remove four screws holding firebox bottom in place.
2.
Lift and remove firebox bottom (see Figure 13).
3. If i ns talling GA3700 Blower A ccessory (Models FB32CA and NLFB32C only), see Installing Blower Accessory, page 10.
4. Route flexible gas line from manual shutoff valve into firebox through side.
NOTICE: Most building codes do not permit concealed gas connections. A flexible gas line is recommended to allow ac cessibility from the firebox. The flexible gas supply line connec tion to the manual shutoff valve should be accessible.
5.
Install and properly test gas log heater. Follow installation instructions included with the vent­free gas log heater that is being installed.
6. Replace firebox bottom and secure with screws.
-
-
Heater Base
Screws
Mounting Bracket
Firebox Bottom
Figure 14 - Cutting Brackets
INSTALLING FIREPLACE HOOD
NOTICE: The firebox canopy (hood) must not be modified or replaced with a canopy (hood) that may be provided with the unvented decorative room heater.
1. Attach three zinc-colored shoulder screws to back of hood.
2. Insert hood into hood-mount ing slots on firebox.
3. Hold hood in place. Insert two black Phillips screws through bottom of hood and tighten.
Hood
Hood Mounting Slot
Shoulder Screw
Screw
Screws
Figure 13 - Removing Firebox Bottom
www.desatech.com
Figure 15 - Installing Fireplace Hood
105604-01H12
INSTALLATION
Continued
INSTALLING FIREPLACE SCREEN
1. Insert each rod through nine rings located at top of screen.
2. Insert first rod into rear hole in left side of firebox. Fasten rod to rear hole near center of firebox using black shoulder screw.
3. Insert other rod into front hole on right side of firebox and fasten using remaining shoulder screw.
Front and Rear Hole
Screw
2. If using an optional GA3700 blower (FB32CA and NLFB32C models only), install a properly grounded, 120 volt three-prong electrical out let at firebox location if an outlet is not there. If possible, locate outlet so cabinet mantel will cover it when installed (see Figure 18).
3.
Install gas piping to firebox location. This instal­lation includes an approved flexible gas line (if allowed by local codes) and a manual shutoff valve. The flexible gas line must be the last item installed on the gas piping. See Connecting to Gas Supply in your log set ownerʼs manual.
NOTICE: A qualified service per­son must connect firebox to gas supply. Follow all local codes.
Rod
Ring
Screen
Figure 16 - Installing Fireplace Screen
(Shown Without Fireplace Hood for
Clarity)
FIREBOX INSTALLATION USING OPTIONAL ACCESSORY MANTELS
This firebox may be installed using the corner or cabinet mantel with hearth base accessories against a wall in your home. You must use a GA6090 brass trim kit included with the mantel accessories (see Accessories, page 12). Follow the instructions below to install the firebox in this manner.
Note: The instructions below show installation using GM100F/GM101U/GM102W/GM106F/ GM107U series cabinet mantels and the G3000F/ G3001U/G3004W/G3006F/G3007U series hearth base accessories. The hearth base accessory shown is optional for this installation. You can install firebox and cabinet mantel directly on the floor. The corner mantel cannot be installed with the G30 00 F/G3001U/G3004W /G 30 06F/G3007U series hearth base. You must install corner and face mantels directly on the floor. If mounting firebox and cabinet mantel to the floor or using corner mantel, an optional G3005 Slim Base kit may be installed.
1. Assemble cabinet mantel, hearth base, brass trim, and trim accessories. Assembly instruc tions are included with each accessory.
105604-01H 13
www.desatech.com
4.
Place hearth base accessory against wall at instal­lation location. Cut an access hole in hearth top to run flexible gas line to firebox (see Figure 17). Make sure to locate access hole so cabinet mantel will cover it when installed. Note: You can secure base to floor using wood screws. Countersink screw heads and putty over.
5. Route flexible gas line through access hole in hearth base.
6.
Center cabinet mantel on hearth base (see Figure
18). Make sure mantel is flush against wall.
Hearth Base
Cabinet Mantel
-
Rigid Pipe and Gas Shutoff Valve
Figure 17 - Placing Hearth Base
Accessory Against Wall
Figure 18 - Installing Cabinet Mantel
Electrical Outlet
Gas Line Access Hole
-
INSTALLATION
34
3
/
4
"
17
3
/
4
"
33" (FB32CA and
NLFB32CA)
34
1
/
4
" (FB32NCA and
NLFB32NCA)
39
3
/8
"
27
7
/8
"
55
5
/8
"
34
3
/4
"
Continued
7. Break off nailing flanges (see Figure 19) with hammer or pliers.
IMPORTANT: When installing Brass Trim
Kit, see instructions included with mantel accessory.
8. Place cardboard or other protective material on top of hearth base. Carefully set firebox on protective material, with back of firebox inside mantel opening.
9. Attach flexible gas line to log set. See Con necting to Gas Supply in your log set ownerʼs manual.
10. If installing GA3700 blower (FB32CA and NLFB32C models only), route blower electri cal cord through bushing included with blower accessory in right side firebox support and bushing in side access opening of firebox. Plug electrical cord into electrical outlet. See Installing Blower Accessory, page 10.
11. Carefully insert firebox into cabinet mantel. Be careful not to scratch or damage hearth base, cabinet mantel, or any laminate trim on hearth base. Remove protective material from top of hearth base and from front of firebox (if any). See Figure 20.
12.
Install the trim after final finishing and/or painting of wall. See instructions included with mantel accessory for attaching brass trim.
13.
Che ck all gas connections for lea ks . See Checking Gas Connections in log set ownerʼs manual.
-
Figure 20 - Inserting Firebox Into
Cabinet Mantel
BUILT-IN FIREBOX INSTALLATION
-
Built-in installation of this firebox involves install­ing firebox into a framed-in enclosure. This makes the front of firebox flush with wall. If installing a mantel above the firebox, but you must follow the clearances shown in Figure 7, page 7. Follow the instructions below to install the firebox in this manner.
Frame in rough opening. Use dimensions
1. shown in Figure 21 for the rough opening. If installing in a corner, use dimensions shown in Figure 22 for the rough opening. The height is 33" (FB32CA and NLFB32C) or
1
4
"(FB32NCA and NLFB32NC), which is
/
34 the same as the wall opening in Figure 21.
Figure 19 - Location of Nailing Flanges
Nailing Flanges
www.desatech.com
Figure 21 - Rough Opening for Installing
in Wall
Figure 22 - Rough Opening for Installing
in Corner
105604-01H14
INSTALLATION
Continued
2. Install gas piping to firebox location. This installation includes an approved flexible gas line (if allowed by local codes) after the manual shutoff valve. The flexible gas line must be the last item installed on the gas pip ing. See Connecting to Gas Supply in log set ownerʼs manual.
3. Carefully set firebox in front of rough open ing with back of firebox inside wall opening.
IMPORTANT:
GA6090, see instructions included with brass trim accessory. You must install shoulder screws now.
4. If using GA3700 blower accessory (Models FB32CA and NLFB32C only), see Blower Accessory for built-in installation, page 11.
5. Attach flexible gas line to log set. See necting to Gas Supply in log set owner ʼs manual.
6. Carefully insert firebox into rough opening.
7. Attach firebox to wall studs using nails or wood screws through holes in nailing flange (see Figure 23).
8. Check all gas connections for leaks. See Checking Gas Connections in log set ownerʼs manual.
9. If using optional GA6090 brass trim kit, install the trim after final finishing and/or painting of wall. See instructions included with brass trim accessory for attaching brass trim.
Nails or Wood Screws
If installing Brass Trim Kit
Installing
Con-
Height Front Width Model # Actual Framing Actual Framing
1
" 34
/
4
1
4
" 34
/
3
8
/
3
8
/
3
/
8
3
8
/
" 34 " 34 " 34 " 34
FB32CA 32 NLFB32C 32 FB32NCA 33 NLFB32NC 33
-
Depth
3
16
" 33" 34
/
3
16
" 33" 34
/
11
16
34
/
11
16
" 34
/
Model # Actual Framing FB32CA 16
-
NLFB32C 16 FB32NCA 16 NLFB32NC 16
11
11
11
11
" 17
/
16
" 17
/
16
16
" 17
/
16
" 17
/
3
4
"
/
3
4
"
/
3
4
"
/
3
4
"
/

REPLACEMENT PARTS

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.
PARTS UNDER WARRANTY
Contact authorized dealers of this product. If they canʼt supply original replacement part(s), call DESA Heating Productsʼ Technical Service Department at 1-866-672-6040.
When calling DESA Heating Products, have ready
• your name
• your address
• model and serial numbers of your firebox
• how firebox was malfunctioning
• type of gas used (propane/LP or natural gas)
• purchase date
Usually, we will ask you to return the part to the factory.
PARTS NOT UNDER WARRANTY
Contact authorized dealers of this product. If they canʼt supply original replacement part(s), call DESA Heating Products at 1-866-672-6040 for referral information.
When calling DESA Heating Products, have ready
• model number of your firebox
• the replacement part number
3
4
"
/
3
4
"
/
3
4
"
/
3
4
"
/
Nailing Flanges
Figure 23 - Attaching Firebox to Wall
105604-01H 15
Studs
www.desatech.com
You may have further questions about installation, operation, or troubleshooting. If so, contact DESA Heating Productsʼ Technical Service Department at 1-866-672-6040. When calling please have your model and serial numbers of your heater ready.
You can also visit DESA Heating Productsʼ Techni cal Service web site at www.desatech.com.

TECHNICAL SERVICE

-

ACCESSORIES

Purchase these firebox accessories from your local dealer. If they can not supply these accessories, call DESA Heating Productsʼ Sales Department at 1-866-672-6040 for information. You can also write to the address listed on the back page of this manual.
EQUIPMENT SHUTOFF VALVE GA5010
All models. Equipment shutoff valve with 1/8" NPT tap.
BLOWER ACCESSORY - GA3700
Use with Models FB32CA and NLFB32C only.
The variable speed blower allows you to select the desired speed. The blower circulates heated air from the fireplace into the room.
CABINET MANTEL
GMC11F Series - Walnut Finished GMC12U Series - Unfinished GMC13F Series - Oak Veneer Finished GM102W Series - Off White
All models. Shown with optional base and lami­nate hearth and mantel trim accessories. Dimen sions (WxHxD): 56 3/4" x 48" x 22 3/4"
-
CABINET MANTEL AND FULL HEARTH BASE
GMC90F Series - Oak Finished GMC91U Series - Unfinished Birch GMC92F Series - Cherry Finished Birch
For all models. Mantel features columns, mold­ings, fluting and medallion. 56" x 50" x 24
"
Dimensions (WxHxD):
www.desatech.com
CORNER MANTEL
GMC36F Series - Walnut Finished GMC37U Series - Unfinished GM202F Series - Oak Finished GMC93F Series - Oak Finished with Columns
All models. Shown with optional laminate mantel trim accessory.
Dimensions (WxHxD): 60 7/8" x 48 3/4" x 34 5/8"
HARDWOOD CORNER HEARTH BASE - (Not Shown)
G3000F Series - Walnut Finished G3009U Series - Unfinished G3010F Series - Oak Finished
The corner hearth base creates a handsome riser for the firebox (cannot be used with cabinet mantel or face mantel).Dimensions (WxHxD): 52 1/2" x 6 1/2" x 26"
105604-01H16
ACCESSORIES
Continued
HARDWOOD CABINET HEARTH BASE
GC3333F Series - Walnut Finished GC3334U Series - Unfinished GC3335F Series - Oak Veneer Finished GM3004W Series - Off White
The cabinet hearth base creates a handsome riser for the firebox (cannot be used with corner mantel or face mantel).
Dimensions (WxHxD): 58" x 6 1/2" x 28 9/16"
SLIM HEARTH BASE (Not Shown)
G3005J - Jade Marble Laminate G3005S - Sandstone Marble Laminate G3005B - Black Onyx Marble Laminate
The slim hearth base allows you to further cus tomize your firebox. Dimensions (WxHxD): 41
7
/8" x 5/8" x 10"
PERIMETER TRIM ACCESSORY (Not Shown)
PT32 - Black PT32B - Brushed Brass PT32PB - Polished Brass PT32P - Platinum
Polished brass trim included with all mantel accessories. Optional with built-in installation. Provides a finished appearance covering rough and/or unfinished mantel edges.
BRASS HOOD ACCESSORY - GA6096 (Not Shown)
All models. Decorative polished brass hood en­hances the appearance of the firebox.
-
LAMINATE TRIM FOR HEARTH OR MANTEL
G3002J - Jade Marble Laminate Mantel Trim G3003J - Jade Marble Laminate Hearth Base Trim G3002S - Sandstone Marble Laminate Mantel Trim G3003S - Sandstone Marble Laminate Hearth Base Trim G3002B - Black Onyx Marble Laminate Trim G3003B - Black Onyx Marble Laminate Hearth Base Trim
Mantel trim for cabinet or corner mantel. Hearth base trim for hardwood hearth bases.
105604-01H 17
www.desatech.com

ILLUSTRATED PARTS BREAKDOWN

5
14
16
16
16
13
15
17
17
17
16
6
1
7
16
18
10
8
20
12
19
9
4*
2*
3*
2*
16
11
18
MODELS FB32NCA AND NLFB32NC
www.desatech.com
105604-01H18
PARTS LIST
This list contains replaceable parts used in your firebox. When ordering parts, follow the instructions listed under Replacement Parts on page 15 of this manual.
KEY PART NUMBER
NO. FB32NCA NLFB32NC DESCRIPTION QTY.
1 101872-03 101872-03 Firebox Top 1 2 101889-01 * Firebrick Retainer 3 3 101929-04 * Rear Firebrick 1 4 101932-04 * Side Firebrick 2 5 103207-01 103207-01 Outer Casing 1 6 103208-01 103208-01 Outer Shell Base 1 7 ** ** Firebox Wrapper 1 8 103297-01 103297-01 Assembly Screen 2 9 103217-01CK 103217-01CK Hood 1 10 103773-02 103773-02 Front Assembly 1 11 ** ** Firebox Bottom 1 12 103809-01 103809-01 Screen Rod 2 13 103816-01 103816-01 Firebox Insulation 1 14 101348-01 101348-01 Firebox Support 2 15 101357-03 101357-03 Outer Casing Top 1 16 M11084-26
____
M11084-26 Hex Head Screw, #10-16 46 17 098194-02 098194-02 Stand Off 3 18 098304-01 098304-01 Phillips Pan Head Screw, #10 11 19 099230-01 099230-01 Hex Head Screw 3 20 099230-02 099230-02 Shoulder Screw 2
*Not Included with Model NLFB32NC ** Not available for field replacement.
____
Hex Head Screw, #10-16 49
105604-01H 19
www.desatech.com
ILLUSTRATED PARTS BREAKDOWN
5
16
16
15
16
17
22
6
1
16
7
16
14
21
13
18
10
8
20
12
19
9
4*
2*
3*
2*
16
11
18
18
MODELS FB32CA AND NLFB32C
www.desatech.com
105604-01H20
This list contains replaceable parts used in your firebox. When ordering parts, follow the instructions
PARTS LIST
listed under Replacement Parts on page 15 of this manual.
KEY PART NUMBER NO. FB32CA NLFB32C DESCRIPTION QTY.
1 101872-03 101872-03 Firebox Top 1 2 101889-01 * Firebrick Retainer 3 3 101929-04 * Rear Firebrick 1 4 101932-04 * Side Firebrick 2 5 103207-01 103207-01 Outer Casing 1 6 103208-01 103208-01 Outer Shell Base 1 7 ** ** Firebox Wrapper 1 8 103297-01 103297-01 Assembly Screen 2 9 103217-01CK 103217-01CK Hood 1 10 103773-01 103773-01 Front Assembly 1 11 ** ** Firebox Bottom 1 12 103809-01 103809-01 Screen Rod 2 13 M12461-2 M12461-2 Screw, Outlet Mounting 1 14 101348-01 101348-01 Firebox Support 2 15 101357-01 101357-01 Outer Casing Top 1 16 M11084-26
____
17 103771-01 103771-01 Strain Relief Fitting 1 18 098304-01 098304-01 Phillips Pan Head Screw, #10 13 19 099230-01 099230-01 Hex Head Screw 3 20 099230-02 099230-02 Shoulder Screw 2 21 GA3555 GA3555 Duplex Outlet 1 22 103457-01 103457-01 Button Plug 1
*Not Included with Model NLFB32C ** Not available for field replacement.
M11084-26 Hex Head Screw, #10-16 46
____
Hex Head Screw, #10-16 49
105604-01H 21
www.desatech.com
NOTES __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________
www.desatech.com
105604-01H22
NOTES __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________
105604-01H 23
www.desatech.com

WARRANTY INFORMATION

105604 01
KEEP THIS WARRANTY
Model
Serial No.
Date Purchased
Always specify model and serial numbers when communicating with the factory.
We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.
LIMITED WARRANTY VENT-FREE FIREBOX
DESA warrants this product to be free from defects in materials and components for four (4) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.
This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this heater to proper operating condition and an allowance for labor when provided by a DESA Authorized Service Center. Warranty part(s) MUST be obtained through authorized dealers of this product and/or DESA who will provide original factory replacement parts. Failure to use original factory replacement parts voids this war ranty. The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit.
This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner.
TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRAN TIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO FOUR (4) YEARS ON ALL COMPONENTS FROM THE DATE OF FIRST PURCHASE; AND DESAʼS LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.
Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.
For information about this warranty write:
-
-
2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 www.desatech.com
NOT A UPC
105604-01 Rev. H 07/04
Loading...