vanEE HRV 90H-V, 1601630, HRV 90H-V ECM, 43905, HRV 60H NOVO+ User Manual

...
User Guide
PLEASE READ AND SAVE THESE INSTRUCTIONS.
HEAT RECOVERY VENTILATORS
HRV 90H-V ECM, 90H-V
AND 60H NOVO+ MODELS:
08373 rev. A
Model no.: 43905
VB0124
Model no.: 1601630
VB0125
Model no.: 1601605
VB0127
2
Congratulations!
You have made an excellent choice! The operating principle of your Heat
Recovery Ventilator will give you personal comfort you have never known before.
We have prepared this User Guide especially for you. Please read it carefully to ensure you obtain full benefit from your unit. Over the coming months, you will increasingly appreciate the feeling of living in a more comfortable house.
Please take note that this manual uses the following symbols to emphasize particular information:
NOTE: Indicates supplementary information needed to fully complete an instruction. We welcome any suggestions you may have concerning this guide and/or the unit,
and we would appreciate hearing your comments on ways to better serve you. Please forward all correspondence to us at the address indicated on the product registration card included with this guide.
WARNING
Identifies an instruction which, if not followed, might cause serious personal injuries including possibility of death.
!
CAUTION
Denotes an instruction which, if not followed, may severely damage the unit and/or its components.
CAUTION
Make sure at all times that the outside hood is free from any snow during the winter season. It is important to check your unit during a big snow storm, so it doesn’t draw in any snow. If this is the case, please operate the unit in the recirculation mode, or turn it OFF for a few hours. Do not use your HRV during construction or renovation of your house or when sanding drywall. This type of dust may damage your system. Since the electronic control system of the unit is incorporated with a microprocessor, it may not operate correctly because of external noise or very short power failure. If this happens, unplug the unit and wait approximately 10 seconds. Then, plug the unit in again.
3
Table of contents
1. DEFROSTING MODE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
2. CONTROLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-11
2.1 INTEGRATED CONTROL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-5
2.2 MAIN CONTROLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-11
2.2.1 Platinum Main Control
(HRV 90H-V ECM & 60H Novo+)
. . . . . . . . . . . . . . . . . . . . . . . . .6-9
2.2.2 Lite-Touch Bronze Main Control
(90H-V only)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
2.2.3 Bronze Main Control
(90H-V only)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
2.3 OPTIONAL AUXILIARY CONTROLS . . . . . . . . . . . . . . . . . . . . . .12-13
2.3.1 20/40/60-minute Push-Button Timer
(HRV 90H-V ECM & 60H Novo+)
. . . . . . . . . . . . . . . . . . . . . . . . .12
2.3.2 20-minute Light Push Button
(90H-V only)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
2.3.3 Humidity Control
(90H-V only)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
2.3.4 60-minute Crank Timer
(All Units)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
3. MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14-15
3.1 SEMI-ANNUAL MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . .14-15
3.2 ANNUAL MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
4. TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
All units are equipped with an integrated control, located under the unit, on the recessed side of electrical compartment. Plug the unit. Use the push button (1) to control the unit. The LED (2) will then show on which mode the unit is in.
Refer to table below to see how to operate the unit using its integrated control.
If a problem occurs during the unit operation, its integrated control LED (2) will blink. The color of the blinking light depends on the type of error detected. Refer to
Section 4 Troubleshooting
on last page for further details.
PRESS ON PUSH BUTTON LED COLOR RESULTS
ONCE AMBER UNIT IS ON LOW SPEED
TWICE GREEN UNIT IS ON HIGH SPEED
THREE TIMES NO LIGHT UNIT IS OFF
When the outside temperature is below -5°C (23°F), recovery of heat creates frost in the core.
To maintain its proper operation, the unit is programmed to defrost the recovery core. The defrost frequency varies according to the outside temperature.
During the defrost cycle, the unit shifts to maximum speed and the dampers close. After defrosting, the unit returns to the operating mode selected by the user.
4
2.
Controls
2.1 Integrated Control
1.
Defrosting Mode
VD0207
1
2
BOTTOM OF THE UNIT
5
2.
Controls (cont’d)
BOOT SEQUENCE (90H-V AND 60H NOVO+ ONLY)
The unit boot sequence is similar to a personal computer boot sequence. Each time the unit is plugged after being unplugged, or after a power failure, the unit will perform a 30-second booting sequence before starting to operate. During the booting sequence, the integrated control LED will light Green (unit set in normal defrost) or AMBER (unit set in extended defrost) for 5 seconds, and then will shut off for 2 seconds. After that, the LED will light RED for the rest of the booting sequence. During this RED light phase, the unit is checking and resetting the motorized damper position. Once the motorized damper position completely set, the RED light turns off and the booting sequence is done.
NOTE: No command will be taken until the unit is fully booted.
BOOT SEQUENCE (HRV 90H-V ECM ONLY)
The unit boot sequence is similar to a personal computer boot sequence. Each time the unit is plugged after being unplugged, or after a power failure, the unit will perform a 30-second booting sequence before starting to operate. During the booting sequence, the integrated control LED will light AMBER for 10 seconds. After that, the LED will light RED for the rest of the booting sequence. During this RED light phase, the unit is checking and resetting the motorized damper position. Once the motorized damper position completely set, the RED light turns off and the booting sequence is done.
NOTE: No command will be taken until the unit is fully booted.
2.1 Integrated Control (cont’d)
2.2.1 Platinum Main Control (HRV 90H-V ECM and 60H Novo+ only)
ON-SCREEN INDICATORS
2.2 Main Controls
SMART Mode. Entirely automatic mode optimizing the ventilation. Temperature Indicators. Program Mode. Allows to program the desired ventilation according to
the period of the day. Recirculation Mode. Manual mode performing air recirculation inside
the house. Ventilation Mode. Manual mode performing air exchange with the outside. Animated Arrows showing ventilation status (recirculation or air
exchange). Periods of the day (morning, day, evening and night). Week days. Week-end days. Hour display. AM or PM display. Appears only when setting backlight preferences. Ventilation / Recirculation speeds and programming options.
VC0099
8 10
11
13
1
2
3
12
45
6
7
8
9
10
11
13
1
2
3
12
4
5
6
7
2.
Controls (cont’d)
9
6
For more convenience, this unit can also be controlled using a main control. All the following models can be used, but only one of them can be connected to the unit.
NOTES: 1.The integrated control must be turned OFF to use a main control.
2. If an optional auxiliary control is used, if activated, this auxiliary control will override the optional main control.
7
SMART
SET
MODE PREF
VC0100
C B A
G
E
F
D
A SMART key: Enables and disables the SMART mode. B Set key: • Press 3 seconds to access setting periods for
Program mode.
• Confirms the chosen option and goes to following setting.
C Arrow keys: • Adjust ventilation and recirculation speeds.
• Allows to review the program’s period.
• Adjust Preference and Program values.
D Mode / Pref. key: • Mode: Selects whether Ventilation, Recirculation or
Program mode.
• pref.: Push 3 seconds to access Preference settings.
E Reset filter keys: Press on B and D keys simultaneously for 5 seconds
to turn off (reset) the filter maintenance indicator.
F Power indicator: Illuminates when the control is operating. G Filter maintenance Perform filters maintenance. (Refer to Section 3
indicator: Maintenance).
2.2 Main Controls (cont’d)
2.
Controls (cont’d)
2.2.1 Platinum Main Control (HRV 90H-V ECM and 60H Novo+ only) (cont’d)
CASING INDICATORS AND KEYS
8
Press on MODE / PREF. key (D) for 3 seconds. NOTE:You can exit Preferences setting by pressing on MODE / PREF. key (D) for
3 seconds any time in the process, or wait 60 seconds. The modified values will be kept in memory.
WHAT WILL YOU SEE
If the control will be set for the very first time, the current day will be the first setting to be made; MON (for Monday) will flash on screen. If the control was previously set up, when setting preferences, the control returns to the last preference chosen on previous setting. While setting Preferences, the corresponding setting value flashes (e.g.: while setting current hour, hour is flashing).
HOW TO PROCEED
For every settings in table below:
• Use to select value.
• Press SET key (B) to confirm the selected preference and go to next setting.
SETTING PREFERENCES
SETTING AVAILABLE VALUE DEFAULT OPTIONS
CURRENT DAY MON/TUE/WED/THU/FRI/SAT /SUN MON HOUR DISPLAY 12:00 OR 24:00 12:00
C
URRENT HOUR FROM 0 TO 12 OR 24 12
CURRENT MINUTE FROM 00 TO 59 00 TEMPERATURE UNIT °C OR °F °C INSIDE TEMPERATURE
ON OR OFF ON
DISPLAY
MINIMUM OUTSIDE -40°C TO 0°C -25°C
TEMPERATURE OR OR FOR AIR EXCHANGE* -40°F TO 32°F -13°F
M
AXIMUM OUTSIDE 1°C TO 40°C 27°C
TEMPERATURE OR OR FOR AIR EXCHANGE* 33°F TO 104°F 81°F
*IN PROG OR SMART MODE, THESE LIMIT VALUES ALLOW TO STOP AIR EXCHANGE
WITH THE OUTSIDE.
B
ACKLIGHT COLOR BLUE OR GREEN BLUE
BACKLIGHT DISPLAY AUTO OR ON AUTO
AUTO: BACKLIGHT ACTIVATED 10 SECONDS WHEN ANY KEY IS PRESSED.
ON: B
ACKLIGHT ALWAYS ON.
OFF MODE FOR VENTILATION/RECIRCULATION
VENT/RECIRC.
INTERMITTENT MODE OR VENTILATION/OFF
AFTER A VENTILATION PERIOD, DETERMINES THE SECOND PART OF THE CYCLE
(RECIRCULATION OR OFF).
The Platinum main control is pre-programmed and ready to go. All you have to do is to set day and time. Then check the settings below and change if needed.
2.2 Main Controls (cont’d)
PM
AM
PM
AM
2.
Controls (cont’d)
2.2.1 Platinum Main Control (HRV 90H-V ECM and 60H Novo+ only) (cont’d)
9
Pressing on MODE / PREF. key (D) successively allows to go from Ventilation mode to Recirculation mode and then to Program mode (VENT , RECIRC and PROG on control screen).
•In Ventilation Mode, use to change the ventilation speed (displayed in in all options except RECIRC).
•In Recirculation mode, use to change the recirculation speed (displayed in , OFF, MAX).
•In Program mode, use to review the period settings without changing them (the period icons are displayed in ).
Pressing once on A allows to turn the ventilation unit in Smart mode. On this mode, the ventilation unit operation will be driven by the outdoor temperature and by the indoor conditions. Press once more to exit Smart mode.
To change these values:
Press on SET key (B) for 3 seconds, PROG (for program) will appear on screen, and week days will flash. NOTE: You can exit Periods setting by pressing on SET key (B) for 3 seconds any
time in the process, or wait 60 seconds.
• Use to select between setting week days or weekend days.
• Press SET key (B) to confirm the choice, and go to setting daily Period 1. (Period 1 will appear on screen, and hour display will flash.)
• Use to select the period starting hour. NOTE: Time changes by 15 minutes increments.
• Press SET key (B) to confirm and go to select the ventilation speed or type (will flash on screen).
• Use to select the ventilation speed or type.
• Press SET key (B) to confirm and go to daily Period 2. (Period 2 will appear on screen, and hour display will flash.)
Proceed as for Period 1 for all daily periods. Once the ventilation speed or type for daily Period 4 has been selected:
• Press SET key (B) to confirm. NOTE: If the week days were the first to be set, the weekend days will appear
on screen; but if the weekend days were the first to be set, then the week days will appear on screen.
(Period 1 will appear on screen, and hour display will flash.)
• Set periods as described above.
SETTING PERIODS FOR PROGRAM MODE
DAILY PERIODS DEFAULT SETTINGS
PERIOD STARTING HOUR MODE
PERIOD 1 (MORNING) 6:00 AM MIN PERIOD 2 (DAY) 9:00 AM 20 MIN/H PERIOD 3 (EVENING) 5:00 PM MIN PERIOD 4 (NIGHT) 11:00 PM 20 MIN/H
The Program Mode allows the user to customize the operation of his/her ventilation unit, for week and weekend days. All days are divided in 4 periods. The periods starting hour and ventilation speed are factory set (see below).
3
4
5
7
13
2.2 Main Controls (cont’d)
2.
Controls (cont’d)
13
2.2.1 Platinum Main Control (HRV 90H-V ECM and 60H Novo+ only) (cont’d)
10
Activate the push button; the color of the indicator shows the unit operating mode.
INTERMITTENT
MAX MIN
VC0080
®
L-T
2.2 Main Controls (cont’d)
2.
Controls (cont’d)
COLOR MODE SUGGESTED USE
GREEN INTERMITTENT SELECT THIS MODE WHEN YOU ARE AWAY FROM THE
HOUSE FOR A FEW DAYS. ALSO, WHEN YOU DEEM THE INSIDE AIR IS TOO DRY IN HEATING SEASON, OR TOO HUMID DURING COOLING SEASON. IN THIS MODE, THE UNIT IS
OFF FOR 40 MINUTES PER HOUR AND
VENTILATES AT MINIMUM SPEED THE REMAINING
20 MINUTES OF THE HOUR.
YELLOW MIN SPEED
VENTILATION
FOR NORMAL DAILY OPERATION.
RED MAX SPEED
VENTILATION
FOR EXCESS POLLUTANTS AND HUMIDITY (PARTIES, ODORS, SMOKE, ETC.).
2.2.2 Lite-Touch Bronze Main Control (90H-V only)
11
ADJUSTING DEHUMIDISTAT Setting during the summer months:
During this period, unless being afflicted with breathing problems, using the Dehumidistat is unnecessary. Set the slide switch to «OFF». (Do not exchange in day time; exchange at night time, if cool outside, or if it is not raining.)
Setting during the fall, winter and spring months: (When severe condensation appears on windows)
1) Determine the humidity level in your house (bring the knob (B)
counterclockwise to its maximum position, then bring it back clockwise slowly until you hear a «click»).
2) Set the knob to one line under this temperature level or «click».
It is possible (and normal) to experience condensation on your windows when drastic changes in temperature happen (for example:
-5°C [23°F] to -20°C [-4°F]). In that case, we suggest waiting a few days to allow the situation to stabilize.
CAUTION
Do not select a temperature below -20°C (-4°F). This could lead to excessive dryness in the air causing discomfort for the occupants.
2.2 Main Controls (cont’d)
2.
Controls (cont’d)
2.2.3 Bronze Main Control (90H-V only)
ADJUSTING AIR SUPPLY CONTROL
1) Select speed «MIN» or «MAX» using slide switch (A).
• When «MIN» (minimum speed)
is selected, if the knob (B) is set above the click, the unit will exchange in low speed with the outside and if it is set below the click, the unit will exchange on high speed with the outside until the desired humidity level has been reached.
• When «MAX» (maximum speed) is selected, the unit will exchange on high speed with the outside either if the knob is set below or above the click.
2) To turn off the unit, slide the switch at the «OFF» position.
C
O
M
F
O
R
T
Z
O
N
E
O
F
F
%
R
E
L
A
T
I
V
E
H
U
M
I
DIT
Y
70%
60%
50%
40%
30%
25%
20%
HUMIDITY CONTROL
DURING FALL, WINTER AND SPRING, SET THE
DIAL ACCORDING TO
THE DESIRED MAXIMUM
INDOOR HUMIDITY LEVEL.
DURING SUMMER SET
THE DIAL TO THE
OFF POSITION.
VC0039
MIN.
MAX.
OFF
M
O
R
E
H
U
M
I
D
L
E
S
S
H
U
M
I
D
C
O
M
F
O
R
T
Z
O
N
E
-30°C
-22°F
-20°C
-4°F
-5°C 23°F
5°C+
41°F+
A
B
12
Press once to activate the push button. The unit will operate on high speed for 20 minutes and the indicator will light up. To stop activation before the end of the 20-minute cycle, push one more time. The unit will get back to its previous setting.
VENTILATION
®
VC0040
ON
2.3.2 20-minute lighted push button (90H-V only)
2.
Controls (cont’d)
Contrary to the main controls, up to 5 optional auxiliary controls can be connected to the same ventilation unit.
Location: Located in the bathroom or in other locations
where there is temporary humidity excess or pollutants.
Purpose: To eliminate excess humidity produced by
showers or other periodic activities producing pollutants.
Within 2 seconds, push one time for 20 minutes, two times for 40 minutes or three times for a 60-minute activation.
Results expected:
1. Motor speed: high for 20, 40 or 60 minutes.
2. Indicator light goes “ON” and flashes every 5 seconds (one time to indicate a 20-minute operation, two times for a 40-minute, and three times for a 60-minute operation).
3. Air exchange indicator light goes “ON”.
NOTE: To stop activation, push one more time.
VC0041
20 min.
40 min.
60 min.
®
2.3 Optional Auxiliary Controls
2.3.1 20/40/60-minute Push-Button Timer (HRV 90H-V ECM and 60H Novo+ only)
This control makes the system operate at high speed for periods varying from 10 to 60 minutes.
OFF
10
20
30
40
50
60
TURN PAST
20
VC0017
Adjust knob to the desired maximum indoor humidity level.
C
O
M
F
O
R
T
Z
O
N
E
O
F F
%
R
E
L
A
T
I
V
E
H
U
M
I
DIT
Y
70%
60%
50%
40%
30%
25%
20%
HUMIDITY CONTROL
DURING FALL, WINTER AND SPRING, SET THE
DIAL ACCORDING TO
THE DESIRED MAXIMUM
INDOOR HUMIDITY LEVEL.
DURING SUMMER SET
THE DIAL TO THE
OFF POSITION.
VC0038
CAUTION
Do not select a humidity level below 30%. This could lead to excessive dryness in the air causing discomfort for the occupants.
2.3.4 60-minute Crank Timer (all units)
2.3.3 Humidity Control (90H-V only)
2.3 Optional Auxiliary Controls (cont’d)
2.
Controls (cont’d)
13
Refer to picture beside to identify the inner parts of your unit.
VD0210
2
1
1) HRV core 2) Core filters
14
1. Unplug the unit.
WARNING
Risk of electric shock. Before performing any maintenance or servicing, always disconnect the unit from its power source. When cleaning the unit, it is recommended to wear safety glasses and gloves.
!
3.1 Semi-Annual Maintenance
VD0005
3. Maintenance
2. Remove the unit door To remove the door follow these steps:
A. Remove both door lower mechanical screws 8-32 x 1” (1) and set aside. B. Open (2) and lift out the door (3).
VO0149
A
B
1
2
3
3.1 Semi-Annual Maintenance (cont’d)
3. Slide out both filters from the unit [(1) in the illustration beside].
4. Slide out the core from the unit [(2) in the illustration beside].
5. Clean the inside walls of the unit with a clean damp cloth, then wipe with a clean dry one.
6. Wash the 2 core filters under hot water with mild soap. Rinse thoroughly and let dry completely before reinstalling on the core.
7. Remove the dust on the core using a vacuum cleaner and a soft brush attachment.
VD0208
8. Slide in the cleaned core into the unit (see
illustration beside).
9. Slide in the cleaned filters into the unit.
NOTE: For HRV 90H-V ECM only, blue side
of filters must be on top.
3.2 Annual Maintenance
Do the same operations as the Semi-Annual Maintenance (
Section 3.1
). Then, clean
the exterior hood(s).
10.Reinstall the door. Secure it with both mechanical screws 8-32 x 1” previously
removed and plug the unit. NOTE: The unit will return to its previous setting after a 30-second delay for
boot sequence.
3. Maintenance (cont’d)
CAUTION
Make sure to align proper symbol on the core (circle or square) with the one on the unit.
1
2
VD0209
15
PROBLEMS TRY THIS...
1.
On Platinum wall control, there is no outside temperature displayed on screen
.
At its very start-up or after a power failure, it Takes some minutes before the outside temperature appears on screen. Set the wall control on MIN or MAX in VENT Mode.
If the problem is not solved by the above, Contact your installer.
2. On Platinum wall control, error code E1, E3 or E4 appears on screen.
Contact your installer.
3. Nothing works. See if the unit is plugged in.
See if the unit is receiving power from the house circuit breaker or fuse.
4. Condensation on windows. (Air too humid.)
•See
Controls Section
on pages 4 to 13.
Leave curtains half-open to allow air circulation.
Store all firewood in a close room with a dehumidifier or in a well ventilated room, or store the wood outside.
Do not adjust the thermostat of your heating system below 18°C (64°F).
5. Inside air too dry. Temporarily use a humidifier.
See
Controls Section
on page 4 to 13.
6. Air too cold at the air supply grille.
Check if the exterior hood is not blocked.
See
Controls Section
on page 4 to 13.
Install a duct heater.
7.
The LED of the integrated control is blinking red.
a) HRV 90H-V ECM only: There is a problem with
one of the motors. The unit is OFF. Contact your installer.
b) 90H-V and 60H Novo+: There is a problem with
the exhaust motor. The unit is OFF. Contact your installer.
8.
The LED of the integrated control is blinking green.
There is a problem with the thermistor. The unit is still working, but will defrost frequently. Contact your installer.
9.
The LED of the integrated control is blinking amber.
There is a problem with the motorized damper. The unit is OFF. For a 2.30-hour period, the unit will try to reset the damper at every 30 minutes. After 2.30 hours, if the problem is not solved, the unit stops trying to reset damper.
Contact your installer.
10.
The integrated control push button does not work.
The 30-second boot sequence is not completed.
See
Integrated Control
on page 4.
4. Troubleshooting
If the problem is still not solved, all your installer or the nearest approved
Service Center. Also, you can reach the Customer Service Department
at the following phone number: 1-800-567-3855.