User Guide
®
40E, 40H+ AND 50H
VB0200
VB0200
VB0201
VB0201
40E MODEL NO. 44262
TOP PORTS SIDE PORTS
40E MODEL NO.44263
40H+* M
ODEL NO. 44252
50H* MODEL NO. 44600
40H+* MODEL NO. 44253
50H* MODEL NO. 44602
Page 2
2
Congratulations!
You have made an excellent choice! The operating principle of your Heat or Energy Recovery Ventilator will give you personal comfort you have never known before.
We have prepared this User Guide especially for you. Please read it carefully to ensure you obtain full benefit from your unit. Over the coming months, you will increasingly appreciate the feeling of living in a more comfortable house.
Please take note that this guide uses the following symbols to emphasize particular information:
WARNING
Identifies an instruction which, if not followed, might cause serious personal injuries including possibility of death.
Denotes an instruction which, if not followed, may severely damage the unit and/or its components.
!
Make sure at all times that the outdoors intake and exhaust hoods are free from any snow during the winter season. It is important to check your unit during a big snow storm, so it doesn’t draw in any snow. If this is the case, please operate the unit in the recirculation mode, or turn it OFF for a few hours.
Do not use your unit during construction or renovation of your house or when sanding drywall. This type of dust may damage your system. Since the electronic control system of the unit uses a microprocessor, it may not operate correctly because of external noise or very short power failure. If this happens, unplug the unit and wait approximately 10 seconds. Then, plug the unit in again.
CAUTION
CAUTION
NOTE: Indicates supplementary information needed to fully complete an instruction.
We welcome any suggestions you may have concerning this guide and/or the unit, and we would appreciate hearing your comments on ways to better serve you. Please forward all correspondence to us at the address indicated on the product registration card included with this guide.
When leaving the house for a long period of time (more than two weeks), a responsible person should regularly check if the unit operates adequately. If the ductwork runs through an unconditioned space (e.g.: attic), the unit must operate continuously except when performing maintenance and/or repair. Also, the ambient temperature of the house should never drop below 18°C (65°F).
CAUTION
Page 3
3
1. DEFROSTING MODE .................................................................3
2. CONTROLS .....................................................................4-15
2.1 INTEGRATED CONTROL ................................................................. 4-5
2.2 P
LATINUM MAIN CONTROL ............................................................ 5-9
2.3 D
ECO-TOUCH MAIN CONTROL .......................................................10-12
2.4 L
IGHT-TOUCH BRONZE MAIN CONTROL ................................................. 12
2.5 S
IMPLE-TOUCH BRONZE MAIN CONTROL ............................................... 13
2.6 B
RONZE MAIN CONTROL ............................................................... 13
2.7 O
PTIONAL AUXILIARY CONTROLS ................................................... 14-15
2.7.1 20/40/60-MINUTE PUSH-BUTTON T IMER ....................................................14
2.7.2 20-MINUTE LIGHTED PUSH BUTTON .........................................................14
2.7.3 DEHUMIDISTAT ..............................................................................15
2.7.4 60-MINUTE CRANK T IMER ...................................................................15
3. MAINTENANCE ................................................................ 16-17
3.1 QUARTERLY MAINTENANCE .......................................................... 16-17
3.2 ANNUAL MAINTENANCE .................................................................. 17
4. TROUBLESHOOTING ............................................................... 18
Table of Contents
1. Defrosting Mode
When the temperature outdoors is below -5°C (23°F), recovery of heat or energy creates frost in the core.
To maintain its proper operation, the unit is programmed to defrost the recovery core. The defrost frequency varies according to the temperature ourtoors.
During the defrost cycle, the unit shifts to maximum speed and the dampers close. After defrosting, the unit returns to the operating mode selected by the user.
R
EPLACEMENT PAR TS AND REPAIR
In order to ensure your ventilation unit remains in good working condition, you must use vänEE genuine replacement parts only. vänEE genuine replacement parts are specially designed for each unit and are manufactured to comply with all the applicable certification standards and maintain a high standard of safety. Any third party replacement part used may cause serious damage and drastically reduce the performance level of your unit, which will result in premature failing. vänEE also recommends to contact a vänEE certified service depot for all replacement parts and repairs.
Page 4
4
2.1 Integrated control
2. Controls
BOOTING SEQUENCE
The unit booting sequence is similar to a personnal computer boot sequence. Each time the unit is plugged after being unplugged, or a power failure occurs, the unit will perform a 30-second booting sequence before starting to operate. During the booting sequence, the integrated control LED will light up and remain GREEN for 5 seconds, and then will turn RED. During this RED light phase, the unit is checking and resetting the motorized damper position. Once the motorized damper position is completely set, the RED light turns off and the booting sequence is done. NOTE: No command will be taken until the unit is fully booted.
All units are equipped with an integrated control, located on the upper left side of the unit.
Use the push button (1) to control the unit. The LED (2) will then show which mode the unit is in.
Refer to table below to see how to operate the unit using its integrated control.
PRESS ON PUSH BUTTON LED COLOR RESULTS
ONCE AMBER UNIT IS ON LOW SPEED
TWICE GREEN Unit is on High speed
T
HREE TIMES NO LIGHT Unit is OFF
If a problem occurs during the unit operation, its integrated control LED (2) will blink. The color of the blinking light depends on the type of error detected. Refer to Section 4 Troubleshooting on last page for further details.
CAUTION
When using optional main control, the integrated control must be turned off.
VE0220
1
2
Page 5
5
For more convenience, these units can also be controlled using a main control. Only one main control can be connected per unit.
NOTES: 1. The integrated control must be turned OFF to use a main control.
2. If an optional auxiliary control is used, it’s activation will override the optional main control.
2.2 Platinum Main Control
2. Controls (cont’d)
Wall control keys and indicators
Press and hold this key for 3 seconds to access Preferences setting menu.
MODE PREF
Press this key to select either Ventilation mode (air exchange with the outdoors), Recirculation mode (air recirculation within the house) or Program mode (the
operation of the ventilation unit is customized by the user. Refer to HOW TO SET
PERIODS FOR PROGRAM MODE section).
Use the arrow keys to:
• Select ventilation and recirculation speeds.
• Review the programmed periods.
• Select Preferences and Program values.
OR
Press this key to enable and disable the SMART mode. The SMART mode uses indoor relative humidity level and minimum and
maximum outdoor temperature values to manage the air exchange with the outdoors, in order to enhance comfort in the house.
MODE/PREF KEY
ARROW KEYS
8 SEC.
Press on Up arrow key for 8 seconds to display indoor relative humidity level (in percentage).
SET
SET KEY
Press and hold this key for 3 seconds to access setting periods for Program Mode.
SMART KEY
SMART
3 SEC.
MODE PREF
Press this key to confirm the chosen option and go to the following setting.
VC0149
SMART
SET
MODE PREF
Page 6
6
FILTER MAINTENANCE INDICATOR
This indicator, located in upper right corner of the wall control, illuminates when it is time to perform the ventilation unit filter maintenance.
Once the filter maintenance is done, reset the filter maintenance indicator as follows:
SET
MODE PREF
BOTH DURING
5 SEC.
Press simultaneously on both Mode/Pref key and SET key for 5 seconds to turn off the filter maintenance indicator.
HOW TO SET PREFERENCES
In order to benefit from all of the features of your wall control, the preferences must be set. Table below shows all available settings.
SETTING AVAILABLE VALUES DEFAULT OPTION
CURRENT DAY MON/TUE/WED/THU/FRI/SAT /SUN MON HOUR DISPLAY 12:00
AM
OR 24:00 12:00
AM
CURRENT HOUR FROM 0 TO 12 OR 24 12 CURRENT MINUTE FROM 00 TO 59 00 TEMPERATURE UNIT °C OR °F °C INDOOR TEMPERATURE DISPLAY ON OR OFF ON MINIMUM OUTDOOR TEMPERATURE
FOR
AIR EXCHANGE*
-40°C TO 0°C OR
-40°F TO 32°F
-25°C OR
-13°F
MAXIMUM OUTDOOR TEMPERATURE
FOR
AIR EXCHANGE*
1°C TO 40°C OR
33°F TO 104°F
27°C OR
81°F
*IN PROG OR SMART MODE, THESE LIMIT VALUES ALLOW TO STOP AIR EXCHANGE WITH THE
OUTDOOR FOR BETTER COMFORT IN THE HOUSE.
BACKLIGHT COLOR BLUE OR GREEN BLUE BACKLIGHT DISPLAY AUTO OR ON AUTO AUTO: B
ACKLIGHT ACTIVATED 10 SECONDS WHEN ANY KEY IS PRESSED.
ON: BACKLIGHT ALWAYS ON. OFF MODE FOR INTERMITTENT MODE VENTILATION/RECIRCULATION
OR
VENTILATION/OFF
VENT/RECIRC.
AFTER A VENTILATION PERIOD, DETERMINES THE SECOND PA RT OF THE CYCLE
(RECIRCULATION OR OFF).
PM PM
2.2 Platinum Main Control (cont’d)
2. Controls (cont’d)
POWER INDICATOR
This indicator, located in upper left side of the wall control, illuminates when the control is powered on.
Page 7
7
Press and hold MODE/PREF key for 3 seconds to access the settings menu.
NOTE: You can exit Preferences setting by pressing on MODE/
PREF for 3 seconds any time in the process, or wait 60 seconds. The modified values will be kept in memory.
MODE PREF
If the control is set for the very first time, the current day will be the first setting to be made: MON (for Monday) will flash on screen.
SMART
SET
MODE PREF
NOTE: While setting Preferences, the corresponding setting value flashes (e.g.: while setting current
hour, hour is flashing).
Use the arrow keys to select value.
OR
Press SET key to confirm the selected preference and go to next setting.
SET
3 SEC.
SETTING PREFERENCES PROCEDURE
2.2 Platinum Main Control (cont’d)
2. Controls (cont’d)
Page 8
8
HOW TO SET PERIODS FOR PROGRAM MODE
The Program Mode allows the user to customize the operation of his/her ventilation unit, for week and weekend days. Each day is divided in 4 periods. The period’s starting hour and ventilation speed are factory set (see below).
DAILY PERIODS DEFAULT SETTINGS
PERIOD STARTING HOUR MODE
PERIOD 1 (MORNING) 6:00 AM MIN
P
ERIOD 2 (DAY ) 9:00 AM 20 MIN/H
PERIOD 3 (EVENING) 5:00 PM MIN
PERIOD 4 (NIGHT) 11:00 PM 20 MIN/H
TO CHANGE THESE VALUES:
Press SET key for 3 seconds.
SET
3 SEC.
SMART
SET
MODE PREF
PROG (for Program) will appear on screen and week days will flash.
NOTE: If the week days were the first to be set, the weekend
days will appear on screen; but if the weekend days were the first to be set, then the week days will appear on screen.
Use the arrow keys to select between week days or weekend days.
OR
Press SET key to confirm the choice and go to setting daily period 1.
SET
SMART
SET
MODE PREF
Period 1 will appear on screen and hour display will flash.
Use the arrow keys to select the period starting hour. NOTE: Time changes by 15 minutes increments.
OR
2.2 Platinum Main Control (cont’d)
2. Controls (cont’d)
Page 9
9
Press SET key to confirm the choice and go to select the ventilation speed or type.
SET
SMART
SET
MODE PREF
Ventilation speeds and type will flash.
Use the arrow keys to select the ventilation speed or type.
OR
Press SET key to confirm the choice and go to setting daily period 2.
SET
Period 2 will appear on screen and hour display will flash. Proceed as for Period 1 for all daily periods. Once the ventilation speed or type for Daily Period 4 has been selected:
Press SET key to confirm and go to weekend days.
SET
SMART
SET
MODE PREF
Weekend days and Period 1 will appear on screen and hour will flash.
Set weekend days periods as for week days.
Press SET key for 3 seconds.
SET
3 SEC.
TO EXIT SETTING PERIODS
HOW TO SET PERIODS FOR PROGRAM MODE (CONTD)
2.2 Platinum Main Control (cont’d)
2. Controls (cont’d)
After a power failure, the Platinum wall control returns to its previous settings. However, if the power failure duration is more than 4 hours, the wall control looses only its day and time settings memory (these must be reprogrammed, see page 7). The rest of the preferences and settings is kept in permanent memory.
POWER FAILURE
Page 10
10
OR
BACKLIGHT
If the backlight is not illuminated, the first button pressed (no matter which button) shall turn on the backlight only, without incurring any other changes. The backlight remains illuminated for 10 seconds after the last button is pressed.
To change the operation mode of the ventilation unit, press the UP or DOWN arrow button. Operating mode label will then scroll up or down on LCD screen.
OPERATING MODES
OFF
Put the unit on stand-by mode, so it will only respond to auxiliairy controls (if present). On LCD screen, only the House is visible showing the control is powered on. This is the factory default mode.
VC0150
RECIRC
Air is recirculated inside the house at high speed.
MIN
Air is exchanged with the outdoors on low speed.
MAX
Air is exchanged with the outdoors on high speed.
20 MIN/H
The ventilation unit exchanges air intermittently on a one hour cycle as follows: OFF for 40 min. (or recirculation on high speed for 40 min., see next page) and then air exchange during 20 min. on low speed. Repeat cycle after the 20 min. of air exchange.
2.3 Deco-Touch Main Control
2. Controls (cont’d)
Page 11
11
HOW TO SET THE RELATIVE HUMIDITY (RH) LEVEL AND CHOOSE BETWEEN OFF IN STANDBY
OR RECIRCULATION IN STANDBY
Setting the relative humidity level allows to select the maximum desired indoor humidity level (in percentage). This value will be used to start the dehumidistat override (air exchange in high speed).
OR
OR
USE UP OR DOWN
ARROW TO CHANGE TO
RECIRCULATION
IN STANDBY.
Press and hold OK for 3 sec. to access the settings menu. The backlight will be activated during the entire procedure.
The Relative humidity arrow and value will flash (default setting: 45%).
Use the UP or DOWN arrow to change the value. The value changes by 1% increments. Lowest value: 30%. Highest value: 55%. Still flashing.
Press OK button to accept the new value and go to next setting.
Two lines are flashing to show that OFF¹ is in stand by (default configuration setting).
Press OK button to accept and quit setting menu.
Recirculation arrows are turning and rE flashes to show that RECIRCULATION² is in standby.
Press OK button to accept and quit setting menu.
1
OFF in stand by: On 20 min/h mode, the ventilation unit is OFF during 40 minutes and exchanges
air with the outdoors on low speed during the remaining 20 minutes of the hour. This is the default value.
2
RECIRCULATION in stand by: On 20 min/h mode, the ventilation unit recirculates the indoors air
for 40 minutes on high speed and exchanges air with the outdoors on low speed during the remaining 20 minutes of the hour.
2.3 Deco-Touch Main Control (cont’d)
2. Controls (cont’d)
Page 12
12
DEHUMIDISTAT OVERRIDE SELECTION
In the operating modes MIN, MAX, 20 min/h and RECIRC, the user can select a dehumidistat override so that if the relative humidity (RH) in the house exceeds the RH setting previously stored, the ventilation unit will exchange in high speed until the target indoor RH setting is reached.
An air exchanger is not a dehumidifier, but it can change the indoor relative humidity by bringing in drier or more humid air from outdoors during non heating season. The dehumidistat override function is useful to reduce indoors RH when the outdoor air is cool and dry during the heating season. Select a target RH between 30% and 55% according to your comfort. When outdoor relative humidity is high (e.g. in summer), turn off the override by pressing OK until the RH display disappears.
When the dehumidistat override is activated, the AUTO indicator will appear on LCD screen to show that the actual mode is being overridden. Also, the relative humidity appears (if it was not shown, see example at left). Once the target humidity level is reached, the unit goes back into its original operating mode and AUTO disappears from LCD screen.
NOTE: If the actual mode is MAX, only the relative humidity level appears on screen; AUTO label
will not appear.
To engage the dehumidistat override, press OK. The actual indoor RH and the %HUM label appear on LCD screen.
NOTE: If the actual RH is less than 20%, then the humidity indicator will display “LO”, and if the
actual RH is greater than 80%, then the humidity indicator will display “HI”.
To turn off the dehumidistat override, press OK again. The RH and %HUM display will disappear from LCD screen.
MAINTENANCE INDICATOR
The maintenance indicator is represented by an M in a rounded triangle, at the top of the house (see at right). If this indicator is flashing, perform the regular maintenance (3 months), and if it is not flashing, perform the annual maintenance (refer to Section 3).
AND
Resetting Maintenance Indicator: Press simultaneously on both arrow buttons,
Maintenance indicator will disappear from LCD screen.
POWER FAILURE
After a power failure, the wall control returns to its previous operation mode. All settings are kept in memory.
Activate the push-button. The color of the indicator shows the unit operating mode.
2.4 Lite-Touch Bronze Main Control
COLOR MODE SUGGESTED USE GREEN INTERMITTENT SELECT THIS MODE WHEN YO U ARE AWAY FROM
THE HOUSE FOR A FEW DAYS OR WHEN YO U DEEM THE INDOOR AIR IS TOO DRY IN HEATING SEASON, OR TOO HUMID IN COOLING SEASON. IN THIS MODE, THE UNIT IS OFF FOR 40 MINUTES PER HOUR AND VENTILATES AT MINIMUM SPEED THE REMAINING
20 MINUTES OF THE HOUR. YELLOW MIN. SPEED VENTILATION FOR NORMAL DAILY OPERATION. RED MAX. SPEED VENTILATION FOR EXCESS POLLUTANTS AND HUMIDITY (PARTIES,
ODORS, SMOKE, ETC.).
INTERMITTENT
MAX MIN
VC0147
L-T
2.3 Deco-Touch Main Control (cont’d)
2. Controls (cont’d)
After a power failure, the Lite-Touch Bronze will turn off.
Page 13
13
Adjusting AIR SUPPLY CONTROL
1) Select speed “MIN” or “MAX” using slide switch (A).
• When “MIN” (minimum speed) is selected, if the knob
(B) is set above the click, the unit will exchange in low speed with the outdoors and if it is set below the click, the unit will exchange on high speed with the outdoors until the desired humidity level has been reached.
• When “MAX” (maximum speed) is selected, the unit will exchange on high speed with the outdoors no matter if the knob is set below or above the click.
2) To turn off the unit, slide the switch at the “OFF” position.
2.5 Simple-Touch Bronze Main Control
Activate the push-button. The color of the indicator shows the unit operating mode.
RECIRCULATION
MAX MIN
VC0146
S-T
COLOR MODE SUGGESTED USE GREEN RECIRCULATION SELECT THIS MODE WHEN YOU DEEM THE INDOOR
AIR IS TOO DRY IN HEATING SEASON, OR TOO HUMID DURING COOLING SEASON. IN THIS MODE, THE UNIT STOPS EXCHANGING WITH THE OUTDOORS AND RECIRCULATES INDOOR AIR AT HIGH SPEED.
YELLOW MIN. SPEED VENTILATION FOR NORMAL DAILY OPERATION. RED MAX. SPEED VENTILATION FOR EXCESS POLLUTANTS AND HUMIDITY (PARTIES,
ODORS, SMOKE, ETC.).
2.6 Bronze Main Control
Adjusting DEHUMIDISTAT Setting during summer months:
During this period, unless being afflicted with breathing problems, using the dehumidistat is unnecessary. Set the slide switch to “OFF”. (Do not exchange in day time; exchange at night time, if cool outdoors, or if it is not raining.)
Setting during fall, winter and spring months: (When severe condensation appears on windows.)
1) Determine the humidity level in your house (bring the knob (B) counterclockwise to its maximum
position, then bring it back clockwise slowly until you hear a “click”).
2) Set the knob to one line under this temperature level or “click”.
It is possible (and normal) to experience condensation on your windows when drastic changes in temperature happen (for example: -5°C [23°F] to -20°C [-4°F]). In that case, we suggest waiting a few days to allow the situation to stabilize.
CAUTION
Do not select a temperature below -20°C (-4°F). This could lead to excessive dryness in the air causing discomfort for the occupants.
After a power failure, the Simple-Touch Bronze wall control will turn off.
2. Controls (cont’d)
C
O
M
F
O
R
T
Z
O
N
E
O
F
F
%
R
E
L
A
T
I
V
E
H
U
M
I
DIT
Y
70%
60%
50%
40%
30%
25%
20%
HUMIDITY CONTROL
DURING FALL, WINTER AND SPRING, SET THE
DIAL ACCORDING TO
THE DESIRED MAXIMUM
INDOOR HUMIDITY LEVEL.
DURING SUMMER SET
THE DIAL TO THE
OFF POSITION.
VC0039
MIN.
MAX.
OFF
M
O
R
E
H
U
M
I
D
L
E
S
S
H
U
M
I
D
C
O
M
F
O
R
T
Z
O
N
E
-30°C
-22°F
-20°C
-4°F
-5°C 23°F
5°C+
41°F+
A
B
Page 14
14
Press once to activate air exchange. The unit will exchange air with the outdoors on high speed for 20 minutes and the indicator will light up. To stop air exchange before the end of the 20-minute cycle, push one more time. The unit will get back to its previous setting.
Location: Located in the bathroom or in other locations where there is temporary humidity excess or pollutants.
Purpose: To eliminate excess humidity produced by showers or other periodic activities producing pollutants.
Within 2 seconds, push one time for 20 minutes, two times for 40 minutes or three times for a 60-minute activation.
Results expected:
1. Motor speed: high for 20, 40 or 60 minutes.
2. Indicator light goes “ON” and flashes every 5 seconds (one time to indicate a 20-minute operation, two times for a 40-minute, and three times for a 60-minute operation).
3. Air exchange indicator light goes “ON”.
4. When chosen duration is completed, the unit resumes to it’s previous setting.
NOTE: To stop ventilation before the end of the chosen duration, push one more time.
2.7 Optional Auxiliary Controls
VC0144
2.7.1 20/40/60-minute Push-Button Timer
2. Controls (cont’d)
2.7.2 20-minute Lighted Push-Button
Page 15
15
OFF
10
Turn Past
VC0017
20
30
40
50
60
MINUTES
HOLD
This control activates the air exchange with the outdoors on high speed for periods varying from 10 to 60 minutes.
2.7.4 60-MINUTE CRANK TIMER
2.7 Optional Auxiliary Controls (cont’d)
2.7.3 Dehumidistat
2. Controls (cont’d)
C
O
M
F
O
R
T
Z
O
N
E
O
F
F
%
R
E
L
A
T
I
V
E
H
U
M
I
DIT
Y
70%
60%
50%
40%
30%
25%
20%
DURING FALL, WINTER AND SPRING, SET THE
DIAL ACCORDING TO
THE DESIRED MAXIMUM
INDOOR HUMIDITY LEVEL.
DURING SUMMER SET
THE DIAL TO THE
OFF POSITION.
VC0038
CAUTION
Do not select a humidity level below 30%. This could lead to excessive dryness in the air causing discomfort for the occupants.
Adjust knob to the desired maximum indoor humidity level.
Page 16
16
3. Maintenance
Risk of electric shock. Before performing any maintenance or servicing, always disconnect the unit from its power source. Sharp edges may be present. When cleaning the unit, it is recommended to wear safety glasses and gloves.
3.1 Quarterly Maintenance
WARNING
!
VD0244
1
2
1) Core 2) Core filters
Refer to picture beside to identify the inner parts of your unit.
VD0005
1. Unplug the unit.
2. Remove the unit door by following these steps: A. Remove both door lower machine screws no. 8-32 x 1” (1) and set aside. B. Open (2) and lift out the door (3).
VO0191
AB
1
2
3
Page 17
17
3. Slide out both filters (1) and recovery core (2) from the unit.
4. Clean the inside walls of the unit with a clean damp cloth, then wipe with a clean dry one.
5. Remove dust on filters and on core using a vacuum cleaner and a soft brush attachment.
6. Wash both core filters under lukewarm water with mild soap. Rinse thoroughly and let dry completely before reinstalling on the core.
7. Slide the core and the cleaned filters into the unit.
8. Reinstall the door. Secure it with both mechanical screws no. 8-32 x 1” previously removed and plug the unit.
NOTE: The unit will return to its previous setting after a 30-second delay for boot sequence.
3. Maintenance (cont’d)
3.1 Quarterly Maintenance (cont’d)
VD0243
1
2
CAUTION
Follow the instructions on the core label to reinstall it correctly.
3.2 Annual Maintenance
Do the same operations as the Quarterly Maintenance (Section 3.1), and clean the recovery core as follows (refer to the core label):
HRV units: Soak the heat recovery core in a mixture of lukewarm water and mild soap. Rinse thoroughly. Shake the core to remove excess water and let it dry.
ERV units: Remove the dust on the core using a vacuum cleaner and a soft brush attachment.
After reinstalling the core, the filters and the unit’s door, then clean the exterior hoods.
Page 18
18
PROBLEM TRY THIS...
1. On Platinum wall control, there is no outdoor temperature displayed on screen
__
.
• At its very start-up or after a power failure, it takes some minutes before the outside temperature appears on screen. Set the wall control on MIN or MAX in VENT Mode.
• If the problem is not solved by the above, contact your installer.
2. On Platinum or Deco-Touch wall control, error code E1 or E3 appears on screen.
• Contact your installer.
3 Nothing works. • See if the unit is plugged in.
• See if the unit is receiving power from the house circuit breaker or fuse.
4. Condensation on windows (air too humid).
• Operate the unit on maximum speed ventilation until the situation is corrected.
• Leave curtains half-open to allow air circulation.
• Store all firewood in a closed room with a dehumidifier or in a well ventilated room, or store the wood outside.
• Do not adjust the thermostat of your heating system below 18°C (64°F).
5. Indoor air too dry. • Temporarily use a humidifier.
• Operate the unit in recirculation mode (if available).
6. Air too cold at the air supply grille. • Check if the exterior hood is blocked.
• Operate the unit in low speed ventilation, in intermittent or in recirculation mode (if available).
• Install a duct heater.
7. The LED of the integrated control is blinking green.
• There is a problem with the thermistor. The unit is still working, but will defrost frequently.
Contact your installer.
8. The LED of the integrated control is blinking amber.
• There is a problem with the motorized damper. The unit is OFF. For a 2½-hour period, the unit will try to reset the damper every 30 minutes. After 2½ hours, if the problem is not solved, the unit stops trying to reset damper.
• Contact your installer.
9. The integrated control push button does not work.
• The 30-second boot sequence is not completed.
• See Integrated Control on page 4.
4. Troubleshooting
If the problem is still not solved, call your installer or the nearest approved Service Center. You
can also reach the Customer Service Department at the following phone number:
1-800-567-3855.
If the unit does not work properly, reset the unit by unplugging it for one minute and then replug it. If it is still not working properly, refer to table below. First make sure that the integrated control is set to OFF (no LED).