![](/html/dc/dc6e/dc6ed623a7ae6158153eff4b9e27e63f9ce90e4aa99a840d79542917d193b7e9/bg1.png)
ACTpro-100 / ACTpro-1002A
Installation and Operating Instructions
Document ID: A-100542
Edition date: 05.11.2018
![](/html/dc/dc6e/dc6ed623a7ae6158153eff4b9e27e63f9ce90e4aa99a840d79542917d193b7e9/bg2.png)
Data and design subject to change without notice. / Supply subject to availability.
© 2018 Copyright by Vanderbilt International Ltd.
We reserve all rights in this document and in the subject thereof. By acceptance of the document the recipient acknowledges these rights and
undertakes not to publish the document nor the subject thereof in full or in part, nor to make them available to any third party without our prior
express written authorization, nor to use it for any purpose other than for which it was delivered to him.
ACTpro-100
Hereby, Vanderbilt International (IRL) Ltd declares that this equipment type is in compliance with the following EU Directives for CE marking:
• Directive 2014/30/EU (Electromagnetic Compatibility Directive)
• Directive 2011/65/EU (Restriction of the use of certain hazardous substances Directive)
The full text of the EU declaration of conformity is available at: http://van.fyi?Link=DoC
ACTpro-1002A
Hereby, Vanderbilt International (IRL) Ltd declares that this equipment type is in compliance with the following EU Directives for CE marking:
• Directive 2014/30/EU (Electromagnetic Compatibility Directive)
• Directive 2014/35/EU (Low Voltage Directive)
• Directive 2011/65/EU (Restriction of the use of certain hazardous substances Directive)
The full text of the EU declaration of conformity is available at: http://van.fyi?Link=DoC
&
http://van.fyi?Link=ACTpro100
![](/html/dc/dc6e/dc6ed623a7ae6158153eff4b9e27e63f9ce90e4aa99a840d79542917d193b7e9/bg3.png)
Table of Contents
1 Overview 4
1.1 Technical specification 4
1.1.1 ACTpro-1002A electrical specification 4
1.2 Ordering details 5
1.3 Monitoring 5
2 Installation 6
2.1 Wiring 6
2.1.1 DIP switch addressing 7
2.1.2 Wiring for Vanderbilt EM1030e Clock & Data or Wiegand Reader 8
2.1.3 Wiring exit readers 9
2.2 ACTpro-100 9
2.2.1 Mounting 9
2.2.2 Power supply 9
2.3 ACTpro-1002A 9
2.3.1 Mounting 10
2.3.2 Mains power up 10
2.3.3 Load Output 10
2.3.4 Standby Battery 11
2.3.5 Tamper 11
© Vanderbilt 2018 3 A-100542
05.11.2018
![](/html/dc/dc6e/dc6ed623a7ae6158153eff4b9e27e63f9ce90e4aa99a840d79542917d193b7e9/bg4.png)
1 Overview
This guide describes the installation of the ACTpro-100 door stations, which are compatible with all
ACTpro controllers.
The ACTpro-100 is a single door station.
The ACTpro-1002A is a single door station with a 12V DC 2A PSU.
1.1 Technical specification
ACTpro-100 ACTpro-1002A
Input Voltage Range 12V DC 12V DC
Current Consumption 40–120 mA 40–120 mA
Operating Environment Surface mounting
Internal use only
Operating Temperature -10 to +50° C -10 to +40° C
Dimensions (H x W x D mm) 165 x 235 x 55 275 x 330 x 80
Weight (kg) 0.4 2.2
Enclosure Material ABS 1.2mm steel grey powder coated
LED Status Indicators Yes Yes
PSU Fault Output n/a Yes
Lid Opening Tamper Detection (Front) Yes Yes
Rear Tamper Detection No Yes
Surface mounting
Internal use only
75% RH non-condensing
1.1.1 ACTpro-1002A electrical specification
Battery charging Yes
Standby Battery 12V 7Ah Battery
Battery Deep Discharge
Protection
Input: Voltage Rated 100–240V AC
Input: Voltage Operating 90–264V AC
Input: Frequency 50–60Hz
Input: Max Current 1.0A (@ 90V AC)
Input: Mains input fuse T2.0A
Input: Max standby power 0.5W (no load and no battery connected)
© Vanderbilt 2018 4 A-100542
No
05.11.2018