Valor Fireplaces 922ECP, 922ECN User Manual

PORTRAIT
DECORATIVE
Models 922ECN/ECP
Decorative Vented Gas Fireplace
With Coal effect fuel
Installation & Operating Instructions
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Please read this manual BEFORE installing and operating this appliance.
WARNING: If the information in these
instructions is not followed exactly, a  re
or explosion may result causing property damage, personal injury or loss of life.
Do not store or use gasoline or other
 ammable vapors and liquids in the vicinity
of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call
the  re department.
Installation and service must be performed
by a quali ed installer, service agency or the
gas supplier.
This appliance may be installed in an
after-market permanently located,
manufactured (mobile) home where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with
other gases, unless a certi ed kit is used.
This appliance is a domestic room-heating appliance. It must not be used for any other purposes such as drying clothes, etc.
This appliance is suitable for installation in a bedroom or bed sitting room.
Massachusetts: The piping and  nal gas connection must be performed by a
licensed plumber or gas  tter in the State of
Massachusetts.
MILES INDUSTRIES LTD.
4000192-07
©2008, Miles Industries Ltd. All rights reserved.
Manufactured by
British Columbia, Canada
www.miles replaces.com
Thank You ...
For purchasing a Valor by Miles Industries. Your new radiant gas heater is a technical appliance that must be installed by a qualied dealer. Each Valor is fully tested during the production process for your safety and comfort.
Your unit has been professionally installed by:
Dealer Name _______________________________________
Phone Number ______________________________________
Should you encounter an operational problem, call your dealer immediately.
Do not try to repair the unit as you may cause an injury or damage the replace.
The information contained in this installation manual is believed to be correct at
the time of printing. Miles Industries Ltd. reserves the right to change or modify any information or specications without notice. Miles Industries Ltd. grants no warranty, implied or stated, for the installation or maintenance of your heater, and assumes no responsibility for any consequential damage(s).
We recommend that our gas hearth products be installed and serviced by professionals
who are certied in the United
States by NFI (National Fireplace Institute®).
Designed and Manufactured by
Miles Industries Ltd.
190 – 2255 Dollarton Highway, North Vancouver B.C., CANADA V7H 3B1
Tel. 604-984-3496 Fax 604-984-0246
www.milesreplaces.com
© Copyright Miles Industries Ltd., 2008
2
2
Table of Contents
Safety and Warning Information ..............................................................4
Specications ............................................................................................5
Choice of Fronts ........................................................................................6
Options .......................................................................................................6
Location in the room .................................................................................7
Gas Supply Installation ...........................................................................10
Firebox Installation (insert application only) ........................................11
Remote Control Installation ....................................................................12
Ceramic Fuel Bed Installation ................................................................13
923ACF Adorn Cast Front Installation ...................................................15
Adorn Safety Guard Fitting .....................................................................15
Operation Checks ....................................................................................16
Owners Information .................................................................................17
Lighting Instructions ...............................................................................19
Warranty ...................................................................................................20
Replacement Parts ..................................................................................21
33
Safety and Warning Information
READ and UNDERSTAND all instructions carefully before starting the installation. FAILURE TO FOLLOW
these installation instructions may result in possible re
hazard and will void the warranty.
Prior to the rst ring of the replace, READ the Owner’s Information section of this manual.
DO NOT USE this appliance if any part has been under
water. Immediately, CALL a qualied service technician to inspect the unit and to replace any part of the control
system and any gas control that has been under water.
THIS UNIT IS NOT FOR USE WITH SOLID FUEL.
Installation and repair should be PERFORMED by a qualied service person. The appliance and venting
system should be INSPECTED before initial use and at
least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding, etc. It is IMPERATIVE that the unit’s control compartment, burner, and circulating air passageways BE KEPT CLEAN to provide for adequate combustion and ventilation air.
Always KEEP the appliance clear and free from combustible materials, gasoline, and other ammable vapors and liquids.
This gas replace and vent assembly MUST be vented
directly to the outside and MUST NEVER be attached
to a chimney serving a separate solid fuel burning appliance. Each gas appliance MUST USE a separate
vent system. Common vent systems are PROHIBITED.
INSPECT the external vent cap on a regular basis to
make sure that no debris, plants, trees, shrubs are interfering with the air ow.
TURN OFF the gas before servicing this appliance. It is recommended that a qualied service technician perform an appliance check-up at the beginning of
each heating season.
Any safety screen or guard removed for servicing
MUST BE REPLACED
DO NOT place furniture or any other combustible
household objects within 36” of the replace front.
BE CAREFUL not to put any decorating objects sensitive to heat to close above or around the replace as it gets very hot when operating.
DO NOT use this heater as a temporary source of heat
during construction.
before operating this appliance.
NEVER OBSTRUCT the ow of combustion and ventilation air. Keep the front of the appliance CLEAR of all obstacles and materials for servicing and proper operation.
Due to the high temperature, the appliance should be LOCATED out of trafc areas and away from furniture and draperies. Clothing or ammable material SHOULD NOT BE PLACED on or near the appliance.
Children and adults should be ALERTED to the
hazards of high surface temperature and should STAY AWAY to avoid burns or clothing ignition. Young
children should be CAREFULLY SUPERVISED when
they are in the same room as the appliance.
This unit MUST be used with a vent system as described in this installation manual. NO OTHER vent
system or components MAY BE USED.
NOTE: When operating your new replace for the rst time, some vapors may be released due to the burning
of curing compounds used in the manufacture of the appliance. They may cause a slight odor and could cause the ames to be the full height of the rebox, or even slightly higher, for the rst few hours of operation. It is also possible that these vapors could set off any smoke detection alarms in the immediate vicinity. These vapors are quite normal on new appliances. We recommend opening a window to vent the room. After a few hours use, the vapors will have disappeared and the ames will be at their normal height.
44
Specications
Approvals and Codes
This appliance is certied to ANSI Z21.50b–2005/CSA 2.22b–2005 Vented Gas Fireplaces Standard for use in
Canada and USA.
The appliance complies with CGA P.4.1, Testing method for measuring annual replace efciencies. The installation must conform with local codes or, in the absence of local codes with the National Fuel Gas Code, ANSI Z223.1or the Natural Gas and Propane Installation Code CAN/CGA-B149. Only qualied licensed or trained personnel should install the appliance.
Venting
This appliance must be connected to an approved venting system.
Ratings
NG LPG
Altitude (Ft) 0-4500 *
Input Max. (Btu/h) 20,500 19,000
Input Min (Btu/h) 12,000 12,500
Manifold pressure (in.w.c.) 3.7 10.5
Min. Supply pressure (in. w.c.) 5 11
Max. Supply pressure (in. w.c.) 10.5 13
*Tested to CAN/CGA - 2.17 Gas red appliances for use at high altitudes. In USA, installations may require deration
over 2000’—Check local codes.
Electrical
The unit does not require an electrical power source.
Supply Gas
Model 922ECN is for use only with natural gas. Model 922ECP is for use only with propane gas. The supply pressure must be between the limits listed above.
The supply connection is 3/8”NPT male thread. The supply pipe connection is to a exible connector at the left hand side of the appliance.
55
Options
975ZCK Zero Clearance Kit—For installation into combustible type framing.
976BRK Bedroom Kit—Includes optional thermostat handset and wiring harness (for use in Canada only).
923ACF—Adorn Cast Front.
539 or 549 Cast Iron Arch Fronts—Also require #540WDK Wire Dress Guard, supplied separately.
3336 Closure Plate—For insert installations to cover up to 33” high x 36” wide.
Choice of Fronts
21-1/2” 39” 31”
38”
34”
30-1/4”
923 Adorn 539 Windsor Arch with Plate 549 Windsor Arch no Plate
Note : the 539/549 Fronts require a 540 WDK Wire Dress Guard with the 922 heater.
Cast Iron Tolerances – Due to the nature of Cast Iron, dimensional consistency may vary from one unit to the next and some variation in surface nish and atness is to be expected. We have done our best to control and make
allowance, however some variation is inevitable.
Closure plates may be required for insert applications where cast fronts do not cover entire openings.
Standard black 33” high x 36” wide closure plate with black aluminum extrusion edge is available.
For installation instructions with Adorn cast front, see Adorn cast front installation section.
For Windsor Arch cast fronts see instructions supplied with individual kit.
66
Location in the room
ceiling
See mantel table
A
36” min.
to combust.
mat’l
B
Min. 39-1/2”
Center line
Edge of protruding arch
4-3/4”
This appliance must not be connected to a chimney ue serving a separate solid-fuel burning appliance. Note: The State of Massachusetts requires that any ue damper must be removed or permanently welded in the open position.
The appliance can be installed in the following constructions:
Solid-fuel (non-combustible) replaces
As supplied, this appliance can be installed as an inset in an existing solid fuel type replace with a chimney and
4” dia. liner.
The replace must be built in accordance with the national, state provincial or territorial building code recognised by
the authority having jurisdiction, or in the absence of such a code, in accordance with the National Building Code
of Canada or the National Fire Protection Association code in the USA. The size of the replace recess must be sufcient to accommodate the appliance as shown in gure below.
If previously used for burning solid-fuel, the chimney must be swept before installation of the appliance. Both chimney and replace must be checked for soundness before installation of the appliance. The liner must be a type approved by the enforcing authority and installed in accordance with the manufacturer’s instructions.
The appliance must be installed on a oor, which is sufciently at and level to ensure stability. Some replace constructions have a well in the oor at the back that may need to be lled in.
Though not mandatory, we recommend that carpet, soft vinyl or other combustible oor coverings are kept at least 16” from the front of the appliance since these types of materials may be affected by the radiant heat output from this appliance.
The minimum clearances from any combustible constructions at the front of the appliance are shown below.
The appliance must be connected to a vent that is a minimum of 9’-0” in height and must not have any 90
degrees elbows within 9’-0” of the ue outlet of the unit (see g. below). Radiused offsets in the ue liner of
less than 90 degrees are permitted.
Ceiling
Min vent liner Ht 9’-0”
Min Ht before 90 deg elbows is 9’-0”. Radiused offsets in liner are permitted
Mantel depth A
Clearance from base of heater B
1” & 2” 3”-8”
40” 42-1/2”
77