Valor HORIZON H4 650NGK, HORIZON H4 534PGK, HORIZON H4 650PGK, HORIZON H4 534NGK, Legend G3 Installation Instructions Manual

...
HORIZON/H4
Propane Gas Conversion Kit
534/650PGK
For use with Valor Models 534I & 650I Heaters ONLY
INSTALLATION INSTRUCTIONS
Once converted to LPG, this appliance is certifi ed for use from 0–4500 feet. For altitudes above 4500 feet, see local codes.
Kit Contents
1 Pilot injector (marked 27) 1 Burner 1 Injector (marked 260) 1 Set of conversion labels 1 Set of air shutters
Tools Required
Wrenches, to disconnect gas line
Phillips (+) screwdriver, to remove burner module &
pilot shield
Small (jewelers size) fl at blade screwdriver, to set
pressure
Small fl at blade screwdriver, to release pressure tap
on valve
Needle nose pliers, to remove by-pass screw
Hex (Allen) wrench, 4 mm or 5/32”, to remove pilot
injector
Manometer, to set manifold at the valve
WARNING
Use this manual in conjunction with the instal­lation manual supplied with the appliance.
Rating
Maximum 24,000 Btu/hr Minimum 13,000 Btu/hr
General notes regarding conversion
The conversion may be done before or after the appliance is installed into the cavity. However, the gas must be connected in order to set the manifold pressure.
4002603-03
© 2013, Miles Industries Ltd. All rights reserved.
Conversion Procedure
1. If the fi replace is already installed, remove the window, ceramic logs and brick liners.
2. Disconnect the gas inlet pipe from the inlet elbow tting on the valve.
3. Detach the rear log support by removing 5 screws as shown.
4. Detach the burner module by removing 10 screws. If the unit has been burned previously, it may be necessary to pry the burner module gasket as they tend to adhere when removed the fi rst time. Note: When converting log set appliance, 2 screws are under the front log brackets (highlighted below).
6. Remove the 4 screws securing the burner brackets to the burner tray.
7. Detach the two burner support brackets from the burner by removing two nuts, using a 5/16” (8 mm) wrench.
5. Disconnect the burner elbow injector from the pipe, using a 11/16” (17 mm) wrench.
8. Accessing pilot assembly from underside of module, disconnect the pilot pipe, using a 7/16” (11 mm) wrench.
9. Remove the pilot injector. Replace with propane gas injector.