Valor GV60 PLUS Operation Manual

Operation Manual
GV60 PLUS
GV60 PLUS Electronic Ignition Remote Control
For Valor heaters 530, 534, 650, 738, 739M, 1500, 1600, 1700, 1800, MF28 and RF24
Synchronize Remote Control
The receiver and the handset of the remote control sys­tem must be initially synchronized before the fi rst use.
1. Insert alkaline batteries in the remote control battery holder and handset. The battery holder is located beside the receiver, near the control valve under the fi rebox, left of the fi rebox or beside the wall switch.
2. With a sharp object, press and hold the receiver’s reset button until you hear one short and one long beeps. Release the reset button after the second beep.
3. Within the subsequent 20 seconds, press the small
ame button ( ) on the remote handset until you hear two short beeps confi rming the sychronization is set. If you hear one long beep, this indicates the code learning sequence has failed or the wiring is incorrect.
This is a one time setting only and is not required when changing the batteries in the remote receiver. The remote control system is now ready to use.
June 2019
1
Remote Control Operation
O
Current
temperature
(F or C)
Current time (12 or 24 hour clock)
Modes (Manual, Temperature, Timer)
Handset sensor
Battery status
Current
programmed
period (Timer)
Period
start or end
(Temp, Timer)
Radio Frequency
315 MHz for USA and Canada.
This device complies with Part 15 of the FCC Rules and with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
NOTE: Before using the remote control system for the fi rst time, the receiver and the handset must
be synchronized. See the section Synchronize Remote Control on page 1.
IMPORTANT: BEFORE YOU BEGIN, please note that on this system, the settings of time, temperature and automatic ON/OFF can only be programmed when the function display is ashing. Be patient when programming as it can take a few seconds to set.
Note: In the TEMP or TIMER modes, the remote handset senses the room temperature and adjusts the fl ame accordingly.
To communicate, the handset should be within 15feet (4.5 meters) of the fi replace.
Do not leave the handset on the mantel or hearth.
Turn Fireplace ON
Press + buttons until you hear a short beep; release buttons.
Beeping continues until pilot is lit.
Burner lights to maximum fl ame height and handset goes automatically to manual (MAN) mode.
NOTES: On the valve, MAN button must be at ON, in full counter-clockwise position .
ON/OFF switch (if equipped) must be in I (ON) position.
Turn Fireplace OFF
Press button.
When pilot is just turned off , wait 2 minutes to light it again.
Standby Mode (Pilot Flame)
Press and hold to set fi replace to pilot.
FF (returns to set mode,
2
SET (scrolls through
modes and settings)
turns the burner and
WKHSLORWR΍
/DUJHȵDPHEXWWRQȵDPHV
up, sets hours, temperature)
6PDOOȵDPHEXWWRQȵDPHV GRZQDQGR΍VHWVPLQXWHV
temperature)
Adjust Flames Height
With pilot lit, press and hold buttons:
= increase fl ame height
= decrease fl ame height or
set to pilot
For fi ne adjustment, tap buttons.
Express Low and High Fire
Double-click buttons:
= increase fl ame to maximum
height “HI”
= decrease fl ame minimum
height “LO”
NOTE: Flame goes to high fi re fi rst before going to designated low fi re.
x 2
x 2