Valor GV60NTK Installation & Operation Instructions

GV60NTK
Non-Thermostatic Kit
For use with Valor GV60 PLUS or MAX* Remote Control Systems ONLY
INSTALLATION & OPERATION INSTRUCTIONS
Non-Thermostatic Handset
The handset GV60NTK is used with the Valor GV60 PLUS or MAX
and the set the fl ame height. It has no thermostat or programming functions and it does not shutdown automatically. The handset shows the current time and the room temperature.
* receivers to turn the re on or off
*NOTE: The handset GV60NTK does not operate
the fan control, the lighting control or the duplex burner fi replaces with GV60 MAX systems.
Synchronizing the NT handset to the remote control receiver
The receiver and the handset of the remote control sys­tem must be initially synchronized before the fi rst use of a new handset.
Current room temperature
Current time
Valor logo only
G6R-H3D6
The non-thermostatic (NT) handset is identifi ed with a Valor logo only. It shows the current time and room temperature. The number shown on its back cover label is G6R-H3D6
Back cover label
1. Insert alkaline batteries in the remote control receiver and handset. The receiver is located left of the control valve under the burner module.
2. With a sharp object, press and hold the receiver’s reset button until you hear one short and one long beeps. Release the reset button after the second beep.
3. Within the subsequent 20 seconds, press the small ame button ( ) on the remote handset until you hear two short beeps confi rming the sychronization is set.
This is a one time setting only and is not required when changing the batteries in the remote receiver. The remote control system is now ready to use.
4003044-02 © Copyright Miles Industries Ltd., 2011.
www.valorfi replaces.com
The one-hour feature is maintained when using a
1265WSK wall switch.
One handset can be used to synchronize multiple
receivers to activate the one-hour feature.
Synchronizing the receiver again with a thermostatic
handset will reactivate the thermostat, programming and auxiliary functions.
Remote Control Operation
Current
temperature
(F or C)
Current time (12 or 24 hour clock)
Handset sensor
Battery status
NOTE: Before using the remote control system with the new NT handset, the receiver and the new handset must be synchronized. See previous page of this manual.
IMPORTANT: BEFORE YOU BEGIN, please note that on this system, the settings of time and temperature can only be set when the function display is fl ashing. Be patient when setting the handset as it can take a few seconds to set.
Large ame
Display Overview
To communicate, the handset should be within 15 feet (4.5 meters) of the fi replace.
Do not leave the handset on the mantel or hearth.
(turns the burner
OFF
and the pilot o)
button (ames up, sets hours, temperature)
Small ame button (ames down and o, sets minutes)
Handset Overview
Turning your fi replace ON
IMPORTANT: When the pilot is lit, the valve motor
turns automatically to maximum fl ame height.
1. Make sure that the MAN knob on the valve is in ON position.
2. Make sure that the switch on the valve is in the I position (except on 650 and 1500 fi replace
models).
3. Press and hold the OFF and (large fl ame) buttons until you hear a short acoustic signal.
Release the buttons.
The acoustic signals will continue until the pilot lights. The fl ame will be at maximum height until the remote control reads the temperature (factory set) and will then adjust the fl ame accordingly.
Turning your fi replace OFF
1. Press the (small fl ame) button to reduce the fl ame to pilot.
2. Press the OFF button to turn the pilot off.
Alternately, you can press the O button on the switch if you won’t use your fi replace for a long period of time, if you cannot locate your remote control handset or if you wish to change the batteries (except on 650 and 1500 fi replace models).