Valor CHURCHILL 32-810-58 Owner's Manual

OWNER’S GUIDE
THIS APPLIANCE IS FOR USE WITH NATURAL GAS (G20)
THIS APPLIANCE IS FOR USE IN THE UNITED KINGDOM (GB) AND
THE REPUBLIC OF IRELAND (IE) ONLY.
This guide is intended to help you care for your gas fire. Please read thoroughly
before using and keep for future reference
For Service Phone 0845 960 5040
Lane, Erdington, Birmingham B24 9QP
This guide to be left with the owner
© Valor Heating
3002402/02
Churchill
Balanced Flue
(GC No. 32-810-58)
ROOM SEALED RADIANT/ CONVECTOR GAS FIRE
(Manufacturer ref. 4733)
OWNER’S GUIDE
Page 2
Safety First.
This fire is CE Approved and designed to meet the appropriate British Standards
and Safety Marks.
Quality and Excellence
This fire has been manufactured to the highest standards of quality and excellence
and was manufactured under a BS EN ISO 9001 quality system accepted by the
British Standards Institute.
The Highest Standards
The manufacturer is a member of the Society of British Gas Industries which works
to ensure high standards of safety, quality and performance.
Careful Installation
The manufacturer is a CORGI registered company. This gas fire must be
installed by a competent CORGI Registered Installer in accordance
with our Installer Guide and should not be fitted directly on to a
carpet.
Because our policy is one of constant development and improvement, details may vary slightly from those
given in this publication
OWNER’S GUIDE
Page 3
LIST OF CONTENTS
SAFETY.....................................................................................................................4
1. GAS CONSUMPTION..................................................................................... 7
1. GENERAL SPECIFICATION ...........................................................................7
2. OPERATION .................................................................................................... 8
2.3 To light the pilot .................................................................................................8
2.4 To select the burner setting.................................................................................8
2.5 To turn off........................................................................................................... 9
3. CLEANING.....................................................................................................10
3.1 To clean the inside of the window....................................................................10
3.2 Cleaning the coal pieces ................................................................................... 10
3.3 Replacing the coal pieces .................................................................................11
4 SERVICING & MAINTENANCE ...............................................................15
CUSTOMER CARE
This gas fire is designed to meet the most stringent quality, performance and safety requirements to provide our customers with many years’ trouble-free service.
Your owner guide aims to improve your understanding and appreciation of your gas fire by providing simple and informative instructions to ensure that you benefit from the excellent performance and features it has to offer.
OWNER’S GUIDE
Page 4
SAFETY
IF YOU SMELL GAS DON’T SMOKE EXTINGUISH ALL NAKED FLAMES DON’T TURN ELECTRICAL SWITCHES ON OR OFF TURN OFF THE GAS SUPPLY AT THE METER OPEN DOORS AND WINDOWS TO GET RID OF THE GAS IMMEDIATELY CALL THE GAS EMERGENCY SERVICE - SEE YOUR LOCAL TELEPHONE DIRECTORY
DO
✔✔✔✔ Have the fire installed by a competent person. In the United Kingdom,
installation must be in accordance with the latest edition of the Gas Safety (installation & use) Regulations. In the Republic of Ireland, installation must be in accordance with all national and local regulations in force.
✔✔✔✔ Have the fire installed in accordance with the installation instructions. ✔✔✔✔ Provide a minimum clearance as shown in graph 1 above the extreme top
surface of the fire to a shelf made of wood or other combustible material. Please bear this in mind if you are making any alterations to the room.
Graph 1. Combustible shelf clearances.
OWNER’S GUIDE
Page 5
✔✔✔✔ Provide the following clearance for combustible projections up to a depth of
178mm (Measured from the rear fixing plane of the fire). A minimum clearance of 75mm should be maintained at the left and right side of the fire. This is measured from the extreme side of the case. This will allow easy access to the control knob and knurled nuts for removal of the outer case. This clearance is mandatory for temperature requirements.
✔✔✔✔ Provide the following clearances for combustible projections beyond 178mm
(Measured from the rear fixing plane of the fire). A minimum clearance of 100mm should be maintained at the left and right side of the fire. This is measured from the extreme side of the case. This clearance is mandatory for temperature requirements.
✔✔✔✔ Provide the following clearances for non-combustible projections. (Measured
from the rear fixing plane of the fire). A minimum clearance of 75mm should be maintained at the left and right side of the fire. This is measured from the extreme side of the case. This will allow easy access to the control knob and knurled nuts for removal of the outer case
✔✔✔✔ Provide a suitable guard that complies with BS 6539 or 6778 for the protection of
young children, the elderly and the infirm. Such a guard is also recommended for the protection of pet animals. Although this fire conforms to all the applicable
standards, it is a heating appliance and certain parts of its surface will become hot.
✔✔✔✔ Wait three minutes before attempting to relight if the fire is switched off or the
flames are extinguished for any reason. Your fire is fitted with a safety device
that will automatically shut off the gas supply to the fire if, for any reason, the flames go out.
✔✔✔✔ Get advice about the suitability of any wall covering near your fire. Soft wall
coverings (e.g. embossed vinyl, etc.) which have a raised pattern are easily affected by heat. They may, therefore, scorch or become discoloured when close to a heating appliance. Please bear this in mind whenever you are considering redecorating.
✔✔✔✔ Keep the flue terminal on the outside wall free from all obstructions and
blockages.
DON’T
H Hang clothing, towels or any other fabrics over the fire. H Use the fire without the glass window panel in position or with damaged glass. H Add any additional coals on to the ceramic fuel pieces supplied with the fire.
This could cause a safety hazard.
Loading...
+ 10 hidden pages