Valor 941 Installer And Owner Manual

© Baxi Heating U.K. Limited 2011.
5139632/01
Model 941
INSET LIVE FUEL EFFECT GAS FIRE
Fitted with one of the following fascia.
Blenheim, Dream or Petrus.
INSTALLER AND OWNER GUIDE
Please keep me in a safe place for future use.
We trust that this guide gives sufficient details to enable this appliance to be installed, operated and maintained satisfactorily. However, if further information is required, our Valor Technical Helpline will be pleased to help. Telephone 0844 8711 565 (National call rates apply in the United Kingdom). In the Republic of Ireland Telephone 0044 844 8711 565.
© Baxi Heating U.K. Limited 2011.
Page 2
© Baxi Heating U.K. Limited 2011.
All rights reserved. No part of this publication may be reproduced in any material form
(including photocopying), stored in any medium by electronic means (including in any
retrieval system or database) or transmitted, in any form or by any means, whether
electronic, mechanical, recording or otherwise, without the prior written permission of
the copyright owner.
Applications for the copyright owner's permission to reproduce any part of this
publication should be made, giving details of the proposed use, to the following
address: The Company Secretary, Baxi Heating UK Limited, Brooks House, Coventry
Road, Warwick, CV34 4LL.
Warning: Any person who does any unauthorised act in relation to a copyright work
may be liable to criminal prosecution and civil claims for damages.
Valor Fires, Erdington, Birmingham B24 9QP
www.firesandstoves.co.uk
Because our policy is one of constant development and improvement, details may vary slightly from
those given in this publication
THIS APPLIANCE IS FOR USE WITH NATURAL GAS (G20).
WHEN CONVERTED USING CONVERSION KIT NO. 0595211 THIS APPLIANCE
IS FOR USE WITH PROPANE GAS (G31).
THIS APPLIANCE IS SUITABLE ONLY FOR INSTALLATION IN THE UNITED
KINGDOM (GB) AND THE REPUBLIC OF IRELAND (IE).
Page 3
Safety First.
Valor fires are CE Approved and designed to meet the appropriate British Standards
and Safety Marks.
Quality and Excellence.
All Valor fires are manufactured to the highest standards of quality and excellence
and are manufactured under a BS EN ISO 9001 quality system accepted by the
British Standards Institute.
The Highest Standards
Valor is a member of SBGI and HHIC (Heating and Hot water Industry Council) that
work to ensure high standards of safety, quality and performance.
Careful Installation
This gas fire must be installed by a competent GAS SAFE REGISTER engineer in
accordance with this installer guide.
© Baxi Heating U.K. Limited 2011.
© Baxi Heating U.K. Limited 2011.
Page 4
INSTALLER GUIDE
INSTALLER GUIDE
FOR OWNER GUIDE SEE PAGES 43 TO 55
CONTENTS
Section Heading Page
INSTALLER GUIDE 4 - 42
OWNER GUIDE 43 - 55
1. FASCIA IMAGES 7
2. SAFETY AND UNPACKING 8
3. APPLIANCE DATA, EFFICIENCY AND NOx 9
3.1 General information. 9
3.2 Efficiency. 9
3.3 NOx 10
4. GENERAL INSTALLATION REQUIREMENTS 10
4.1 Regulations, Standards and Law. 10
4.2 Ventilation requirements. 11
4.3 The Atmosphere sensing device (ASD). 11
4.4 Fireguard requirements. 11
4.5 Room considerations. 11
4.6 Chimney preparation. 12
4.7 Fireplace preparation. 12
4.8 The hearth. 13
4.9 Fireplace clearances. 13
4.10 Installation options. 15
4.10.1 Conventional fireplace and hearth. 15
4.10.1.1 ‘Hole-in-the-wall’ Installations. 16
4.10.2 Metal flue box and hearth. 16
4.10.3 Precast concrete or clay flue block system and hearth. 17
4.11 Flues. 18
5. PACK CONTENTS 19
6. FIREPLACE CHECK 22
6.1 Soundness for appliance attachment. 22
6.2 Fireplace flue pull. 22
7. IGNITION CHECK 23
8. GAS SUPPLY CONNECTION 23
9. PREPARING APPLIANCE FOR INSTALLATION 24
10. HOTBOX INSTALLATION 26
10.1 Method 1 - Cable retention and floor fixing. 26
10.2 Method 2 - Front fixing to fireplace surround. 28
10.3 Sealing floor front - All installations. 29
Page 5
© Baxi Heating U.K. Limited 2011.
Continued on next page
INSTALLER GUIDE
CONTENTS (Continued)
Section Heading Page
11. BURNER & SUPPLY PIPE INSTALLATION 29
11.1 Burner and supply pipe installation. 29
11.2 Preliminary burner checks. 29
11.3 Inlet pressure check. 30
12. CERAMIC WALLS INSTALLATION 31
13. FITTING THE BURNER BAFFLE 31
14. FITTING THE FASCIA 32
14.1 Fitting the Blenheim fascia. 32
14.2 Fitting the Dream fascia. 32
14.3 Fitting the Petrus fascia. 33
15. FITTING THE CERAMIC FUEL EFFECT 35
16. OPERATING AND SPILLAGE CHECKS 35
16.1 Check the control settings. 35
16.1.1 Lighting the burner. 35
16.1.2 Operating the burner. 35
16.2 Check for spillage. 36
16.3 Flame supervision and spillage monitoring system. 36
17. FINAL REVIEW 37
18. SERVICING & PARTS REPLACEMENT 38
18.1 Checking the aeration setting of the burner. 39
18.2 To remove the Blenheim fascia. 39
18.3 To remove Dream fascia. 39
18.4 To remove Petrus fascia. 39
18.5 To remove the complete burner unit. 40
18.6 To remove the pilot unit. 40
18.7 To remove the gas valve. 41
18.8 To remove the piezo generator. 41
18.9 To grease the control tap. 41
18.10 To replace the burner. 42
18.11 To remove the main burner injector. 42
18.12 To remove the appliance from the fireplace. 42
© Baxi Heating U.K. Limited 2011.
Page 6
INSTALLER GUIDE
1. FASCIA IMAGES
Page 7
© Baxi Heating U.K. Limited 2011.
INSTALLER GUIDE
Petrus
Blenheim
Dream
2. SAFETY AND UNPACKING
Installer
Before continuing any further with the installation of this appliance please read the following guide to manual handling:
The approximate lifting weight (kg) of this appliance is as below:
Model
Heat Engine Fascia, firefront and ash pan Combined Weight Blenheim 4.9 3.9 8.8 Dream 4.9 11.7 16.6 Prelude 4.9 13.4 18.3
One person should be sufficient to lift the fire. If for any reason this weight is
considered too heavy then obtain assistance.
When lifting always keep your back straight. Bend your legs and not your back. Avoid twisting at the waist. It is better to reposition your feet. Avoid upper body/top heavy bending. Do not lean forward or sideways whilst
handling the fire.
Always grip with the palm of the hand. Do not use the tips of fingers for support. Always keep the fire as close to the body as possible. This will minimise the
cantilever action.
Use gloves to provide additional grip. Always use assistance if required.
This product uses fuel effect pieces and burner compartment walls containing
Refractory Ceramic Fibres (RCF), which are man-made vitreous silicate fibres. Excessive exposure to these materials may cause irritation to eyes, skin and respiratory tract. Consequently, it is important to take care when handling these articles to ensure that the release of dust is kept to a minimum. To ensure that the release of fibres from these RCF articles is kept to a minimum, during installation and servicing we recommend that you use a HEPA filtered vacuum to remove any dust and soot accumulated in and around the fire before and after working on the fire. When replacing these articles we recommend that the replaced items are not broken up, but are sealed within a heavy duty polythene bag, clearly labelled as RCF waste. RCF waste is classed as a stable, non-reactive hazardous waste and may be disposed at a landfill licensed to accept such waste. Protective clothing is not required when handling these articles, but we recommend you follow the normal hygiene rules of not smoking, eating or drinking in the work area and always wash your hands before eating or drinking.
This product does not contain any component manufactured from asbestos or
asbestos related products.
© Baxi Heating U.K. Limited 2011.
Page 8
INSTALLER GUIDE
3. APPLIANCE DATA, EFFICIENCY AND NO
x
3.1 General information.
*When converted using kit 0595211.
The appliance information label and serial number label are located on a plate at the base of the fire, underneath the burner. This can be seen by removing the firefront / ash pan.
3.2 Efficiency.
The efficiency of this appliance has been measured as specified in BS 7977 - 1 and the result is as below:
Model
Efficiency % (Gross)
941 Natural gas 55 941 when converted to LPG. 53
The gross calorific value of the fuel has been used for this efficiency calculation. The test data from which it has been calculated has been certified by Advantica Certification services (0087). The efficiency value may be used in the UK Government's Standard Assessment Procedure (SAP) for energy rating of dwellings.
Page 9
© Baxi Heating U.K. Limited 2011.
INSTALLER GUIDE
Gas Natural (G20) Propane (G31) *
Inlet Pressure 20mbar 37mbar
Input - Max. (Gross) 6.8kW (23,400 Btu/h) 6.7kW (22,860 Btu/h)
Input - Min. (Gross) 2.3kW (7,850 Btu/h) 4.0kW (13,650 Btu/h)
Inlet Test Pressure (Cold)
20.0 ± 1.0 mbar
(8.0 ± 0.4in w.g.)
37.0 ± 1.0 mbar
(14.85 ± 0.4in w.g.)
Gas Connection 8mm pipe 8mm pipe
Burner Injector Cat 82 - 074 Size 132
Pilot & Atmosphere
Sensing Device
Copreci Ref. O.D.S
21500/166
Copreci Ref. O.D.S
21500/166 Fitted with RBM
180 -02 injector
Ignition
Integral piezo
(Mounted on gas valve)
Integral piezo
(Mounted on gas valve)
Aeration Factory set Non-adjustable
The conversion of net efficiency to gross was achieved by multiplying the net efficiency by the following conversion factor from Table E3 of SAP 2005, rounding down to the nearest whole number.
3.3 NO
x
The 'Weighted' result for this appliance equates to:
Model NOx Class
941 Natural gas 2. 941 when converted to LPG I.
4. GENERAL INSTALLATION REQUIREMENTS
4.1 Regulations, Standards and Law.
The installation must be in accordance with these instructions. For the user’s protection, in the United Kingdom it is the law that all gas appliances are installed by competent persons in accordance with the current edition of the Gas Safety (Installation and Use) Regulations. Failure to install the appliance correctly could lead to prosecution. GAS SAFE REGISTER require their members to work to recognised standards. In the United Kingdom the installation must also be in accordance with: All the relevant parts of local regulations. All relevant codes of practice. The relevant parts of the current editions of the following British Standards:­BS EN 1856 Part 1 - Chimneys - Requirements for metal chimneys. BS 715 - Specification for metal flue boxes for gas-fired appliances not
exceeding 20kW. BS EN 1858 - Chimneys - Components - Concrete flue blocks. BS EN 1806 - Chimneys - Clay / ceramic flue blocks. BS 5440 Part 1 - Installation of flues. BS 5440 Part 2 - Installation and maintenance of flues and ventilation for gas
appliances of rated input not exceeding 70 kW net (1st, 2nd
and 3rd family gases). BS 6461 Part 1 - Masonry chimney & flues - Installation BS 1251 - Fireplace components BS 5871 Part 2 - Installation - Inset LFE gas fires BS 6891 - Gas pipework installation
© Baxi Heating U.K. Limited 2011.
Page 10
Gas Conversion factor from net to gross efficiency
Natural Gas 0.901
LPG 0.921
INSTALLER GUIDE
In England and Wales, the current edition of the Building Regulations issued by the
Department of the Environment and the Welsh Office.
In Scotland, the current edition of the Building Standards (Scotland) Regulations
issued by the Scottish Executive.
In Northern Ireland, the current edition of the Building regulations (Northern
Ireland) issued by the Department of the Environment for Northern Ireland.
In the republic of Ireland the installation must be carried out by a competent person
and also conform to the relevant parts of: a) The current edition of IS 813 “Domestic Gas Installations” b) All relevant national and local rules in force. Where no specific instructions are given, reference should be made to the relevant British Standard Code of Practice.
4.2 Ventilation requirements.
Normal adventitious ventilation is usually sufficient to satisfy the ventilation requirements of this appliance. In GB reference should be made to BS 5871 Part 2 and in IE reference should be made to the current edition of IS 813 “Domestic Gas Installations” which makes clear the conditions that must be met to demonstrate that sufficient ventilation is available.
4.3 The Atmosphere sensing device (ASD).
The appliance is fitted with an A.S.D (Atmosphere sensing device). If the appliance closes down after a period of operation for no apparent reason, the consumer should be informed to stop using the appliance until the installation and appliance have been thoroughly checked. The A.S.D will shut the appliance down if an unacceptable amount of harmful products of combustion accumulate. Under no circumstances should the A.S.D be altered or bypassed in any way. Only a genuine manufacturer’s replacement part should be fitted. The individual A.S.D components are not replaceable.
4.4 Fireguard requirements.
A fireguard complying with BS 8423 should be fitted for the protection of young children, the elderly, the infirm and pet animals.
4.5 Room considerations.
4.5.1 This appliance must not be installed in any room that contains a bath or shower or where steam is regularly present.
4.5.2 An extractor fan may only be used in the same room as this appliance, or in any area from which ventilation for the appliance is taken, if it does not affect the safe performance of the appliance. Note the spillage test requirements detailed further on in this guide. If the fan is likely to affect the appliance, the appliance must not be installed unless the fan is permanently disconnected.
Page 11
© Baxi Heating U.K. Limited 2011.
INSTALLER GUIDE
4.5.3 Note that soft wall coverings (e.g. embossed vinyl, etc.) are easily affected by heat. They may scorch or become discoloured when close to a heating appliance. Please bear this in mind when installing.
4.6 Chimney preparation.
4.6.1 If the appliance is intended to be installed to a chimney that was previously used for solid fuel, the flue must be swept clean prior to installation. All flues should be inspected for soundness and freedom from blockages.
4.6.2 Any chimney damper or restrictor should be removed. If removal is not possible, they must be secured in the open position.
4.7 Fireplace preparation.
4.7.1 If the fireplace opening is an underfloor draught type, it must be sealed to stop any draughts.
4.7.2 The fireplace floor should be reasonably flat to ensure that the hotbox can be installed without it rocking and so that a good seal can be made at the bottom front of the box.
4.7.3 The front face of the fireplace should be reasonably flat over the area covered by the hotbox top and side flange seals to ensure good sealing. These faces should be made good if necessary.
4.7.4 If the appliance is to be fitted against a wall with combustible cladding, the cladding must be removed from the area covered by the fascia. The cladding must also not touch the fascia (See figure 1). We suggest that the actual fascia is used as a template to mark the area for combustible cladding removal and that this area is increased by at least 2mm all round.
4.7.5 If the fireplace opening is greater than the acceptable dimensions given in this guide, do not use the back of a fire surround or marble to reduce the opening. This may cause cracking of the surround back or marble.
© Baxi Heating U.K. Limited 2011.
Page 12
Figure 1. Removal of combustible cladding (Fascia may differ from that shown).
INSTALLER GUIDE
4.8 The hearth.
The appliance must be mounted behind a non-combustible hearth unless the conditions of section 4.10.1.1 are met (N.B. conglomerate marble hearths are considered as non-combustible). The appliance can be fitted to a purpose made proprietary class “O”-150°C surround. The hearth material must be at least 12mm thick. The periphery of the hearth (or fender) should be at least 50mm above floor level to discourage the placing of carpets or rugs over it. The surface of the hearth must be sufficiently flat to enable the bottom of the front surround and the bottom front cover to be aligned horizontally. Any excessive unevenness (uneven tiles, Cotswold stone, etc.) should be rectified. The appliance must not stand on combustible materials or carpets.
4.9 Fireplace clearances.
4.9.1 The minimum height from the base of the fireplace opening to the underside of any shelf made from wood or other combustible materials is detailed below.
For a shelf up to 150mm deep: Minimum height = 760mm.
For a shelf deeper than 150mm: 760mm + 12.5mm for every 25mm depth over 150mm (See Figure 2).
Page 13
© Baxi Heating U.K. Limited 2011.
Figure 2. Combustible shelf clearances.
INSTALLER GUIDE
4.9.2 The minimum allowable distance from the outside of the appliance fascia to a corner wall having combustible material or any other combustible surface which projects beyond the front of the appliance is shown in figure 3.
© Baxi Heating U.K. Limited 2011.
Page 14
Figure 3. Appliance dimensions and clearances (Dimensions are subject to manufacturing deviation. Fascia may differ from that shown).
Key
A B C D E
Model
Height
(mm)
Width
(mm)
Depth
into room (mm)
Minimum
mandatory
clearance to
combustible
surfaces projecting beyond the front of
appliance (mm).
Recommended
clearance to non-
combustible
surfaces for access
purposes (mm).
Blenheim 599 492 65 125 10
Dream 636 518 94 100 50
Petrus 636 518 94 100 50
INSTALLER GUIDE
4.10 Installation options.
In the United Kingdom, as supplied, the appliance can be installed in the following situations: -
4.10.1 Conventional fireplace and hearth.
To a fireplace complete with surround and hearth as shown in figure 4 and complying with BS1251 after removal of the fireback and sufficient material behind the fireback for a debris catchment space. The required fireplace, hearth, debris catchment area and clearance dimensions are shown in figure 5.
Page 15
© Baxi Heating U.K. Limited 2011.
Figure 4. Hearth and fireplace opening dimensions
Figure 5. Fireplace area.
INSTALLER GUIDE
4.10.1.1 ‘Hole-in-the-wall’ Installations.
It is recommended that a hearth should be installed as in section 4.8 (See figure
4).
If a hearth is not fitted or a reduced depth hearth is fitted, the fire must be installed
so that the distance from the base of the fireplace opening in the wall to the finished floor level is at least 100mm. Where there is no floor covering or carpet and the floor is of a type that is likely to be covered in such a way in the future then the distance from the base of the fireplace opening in the wall to the floor level should be increased to at least 175mm.
To protect from the risk of burns and ignition of clothing a tactile separator shall be
used. The hearth detailed in section 4.8 meets the requirements for a tactile separator. If this is not used then a 672mm long fender, kerb, horizontal bar, or other barrier, being fixed not less than 50mm above floor level and positioned 300mm in front of the fixing plane of the fire will meet the requirement.
If the lower part of the fascia (the firefront) is free standing, the recommended
reduced hearth depth is 100mm. This is necessary to support the firefront (See figure 3 for appliance dimensions).
4.10.2 Metal flue box and hearth.
The appliance can be installed to a fireplace incorporating a metal flue box complying with the constructional requirements of the current edition of BS 715 and with a flue conforming to BS EN 1856 part 1. The dimensions of the flue box must conform to those shown in figure 6
Important Note: The top surface of the metal flue box must be covered with a 100mm layer of mineral wool or equivalent insulation (See figure 6).
© Baxi Heating U.K. Limited 2011.
Page 16
Figure 6. Metal flue box dimensions
INSTALLER GUIDE
4.10.3 Precast concrete or clay flue block system and hearth.
The appliance can be installed to a precast concrete or clay flue block system conforming to BS EN 1858 with dimensions as in figure 7. BS 1289 part 1 recommends there should be an air space or insulation between the flue blocks and the plaster because heat transfer may cause cracking on directly plastered flues. However, generally this appliance is suitable for installations under all circumstances unless there is a history of cracking problems. Remember that faults such as cracking may be caused by poorly built and restrictive flues, e.g. mortar extrusions, too many bends, flue heights below three metres, restrictive terminations etc.
Page 17
© Baxi Heating U.K. Limited 2011.
Figure 7. Precast or clay flue block system
INSTALLER GUIDE