Valor 530IP, 530ICN/ICP, 530ILN, 530ICN, 530IRN Installation & Owner's Manual

...
PORTRAIT
DV Gas Fireplace Heater
530ILN/ILP (logs), 530ICN/ICP (coals),
530IRN/IRP (rocks)
Installation & Owner’s Manual
!
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed for the protection of children and other at-risk individuals.
! WARNING
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious injury, death, or property damage.
— Do not store or use gasoline or other
ammable vapors and liquids in the vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
▪ Do not try to light any appliance. ▪ Do not touch any electrical switch; do
not use any phone in your building. ▪ Leave the building immediately. ▪ Immediately call your gas supplier from
a neighbor’s phone. Follow the gas
supplier’s instructions. ▪ If you cannot reach your gas supplier,
call the fi re department.
— Installation and service must be
performed by a qualifi ed installer, service agency or the gas supplier.
DANGER
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
This manual contains instructions to install the EN­GINE ONLY. A front trim kit is REQUIRED to install
with the front for framing and fi nishing.
This appliance may be installed in an after-market permanently located, manufactured (mobile) home where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certifi ed kit is used.
This appliance is a domestic room-heating appliance. It must not be used for any other purposes such as drying clothes, etc.
This appliance is suitable for installation in a bedroom or bed sitting room.
Ce guide est disponible en français sur demande.
INSTALLER
Leave this manual
with the appliance.
CONSUMER
Retain this manual
for future reference.
Please read this manual BEFORE installing and operating this appliance.
4001754-20
©2014, Miles Industries Ltd. All rights reserved.
Table of Contents
W
A
R
R
A
N
T
Y
P
R
O
G
R
A
M
V
A
L
O
R
C
O
M
F
O
R
T
V
A
L
O
R
C
O
M
F
O
R
T
FOR THE OWNER FOR THE QUALIFIED INSTALLER
Safety Precautions ................................................. 3
Commonwealth of Massachusetts......................15
Safety and Your Fireplace ......................................4
Owner’s Information ............................................... 5
Operating Your Fireplace for the First Time ............... 5
Cleaning Your Fireplace ............................................ 6
Checking Pilot and Burner Flames ............................ 7
Using Handset Wall Holder ........................................ 7
Replacing Batteries ...................................................7
Locating Lighting, Operation and Rating Information
Plate ..........................................................................8
Servicing Your Fireplace ............................................ 8
Operating Your Fireplace ........................................... 8
How to Turn Your Fireplace OFF (including pilot) ...... 8
How to Ensure Your Fireplace Cannot
Be Turned ON Inadvertently ...................................... 8
Automatic Shut-Off (in certain conditions) ................. 8
Remote Control Operation ..................................... 9
Options .................................................................. 13
Lighting Instructions ............................................14
Warranty ................................................................43
R
O
M
L
A
R
A
G
Warranty Card at the back of this manual.
W
O
V
R
P
Y
T
T
N
A
R
R
R
A
O
C
F
O
M
Specifi cations ....................................................... 17
Dimensions, Clearance and Framing .................18
Venting ................................................................... 18
Co-Axial Venting ...................................................20
Co-Linear Venting ................................................. 27
Installation Planning ............................................28
Installation ............................................................. 29
Unpack Appliance .................................................... 29
Remove Window .....................................................29
Convert from Rear Outlet to Top Outlet
(co-axial venting) ..................................................... 29
Prepare Vent Outlet ................................................. 30
Connect Gas Supply ................................................31
Install Ceramic Walls (530IL and IC only) ................ 32
Install Ceramic Logs (530IL) ....................................33
Install Ceramic Coals (530IC) ..................................34
Install Ceramic Walls and Rocks (530IR) ................ 35
Refi t and Check Window ......................................... 37
Set-up Remote Control ............................................ 37
Check Operation ......................................................38
Set Aeration ............................................................. 38
Install Front, Trim and Barrier Screen ...................... 38
Install Remote Control Handset Wall Holder ........... 39
Wiring Diagram ..................................................... 40
Massachusetts: The piping and fi nal gas connection must be performed by a licensed plumber or gas fi tter in the State of Massachusetts. Also, see Carbon Monoxide Detector requirements on page 15.
190–2255 Dollarton Highway, North Vancouver, BC, CANADA V7H 3B1
2
Approved Venting Components .......................... 41
Warranty ................................................................43
Replacement Parts ............................................... 44
The information contained in this installation manual is believed to be correct at the time of printing. Miles Industries Ltd. reserves the right to change or modify any information or specifi ca- tions without notice. Miles Industries Ltd. grants no warranty, implied or stated, for the installation or maintenance of your heater, and assumes no responsibility for any consequential damage(s).
Designed and Manufactured by / for
Miles Industries Ltd.
Tel. 604-984-3496 Fax 604-984-0246
www.valorfi replaces.com
© Copyright Miles Industries Ltd., 2014. All rights reserved.
Safety Precautions
!
READ and UNDERSTAND all instructions carefully
before starting the installation. FAILURE TO FOLLOW these installation instructions may result in possible fi re hazard and will void the warranty.
Prior to the fi rst fi ring of the fi replace, READ the Owner’s Information section of this manual.
DO NOT USE this appliance if any part has been under water. Immediately, CALL a qualifi ed service technician to inspect the unit and to replace any part of the control system and any gas control that has been under water.
THIS UNIT IS NOT FOR USE WITH SOLID FUEL.
Installation and repair should be PERFORMED by a qualifi ed service person. The appliance and venting system should be INSPECTED before initial use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding, etc. It is IMPERATIVE that the unit’s control compartment, burner, and circulating air passageways BE KEPT CLEAN to provide for adequate combustion and ventilation air.
Always KEEP the appliance clear and free from combustible materials, gasoline, and other fl ammable vapors and liquids.
NEVER OBSTRUCT the fl ow of combustion and ventilation air. Keep the front of the appliance CLEAR of all obstacles and materials for servicing and proper operation.
This unit MUST be used with a vent system as described in this installation manual. NO OTHER vent system or components MAY BE USED.
This gas fi replace and vent assembly MUST be vented directly to the outside and MUST NEVER be attached to a chimney serving a separate solid fuel burning appliance. Each gas appliance MUST USE a separate vent system. Common vent systems are PROHIBITED.
INSPECT the external vent cap on a regular basis to make sure that no debris, plants, trees, shrubs are interfering with the air fl ow.
TURN OFF the gas before servicing this appliance. It is recommended that a qualifi ed service technician perform an appliance check-up at the beginning of each heating season.
DO NOT use this heater as a temporary source of heat during construction.
State of California. Proposition 65 Warning. Fuels used in gas, wood-burning or oil fi red appliances, and the products of combustion of such fuels, contain chemicals known to the State of California to cause cancer, birth defects and other reproductive harm. California Health & Safety Code Sec. 25249.6.
Due to the high temperature, the appliance should be LOCATED out of traffi c areas and away from furniture and draperies.
Clothing or fl ammable material SHOULD NOT BE PLACED on or near the appliance.
This appliance is a DOMESTIC ROOM-HEATING AP- PLIANCE. It must not be used for any other purposes such as drying clothes, etc.
DO NOT place furniture or any other combustible household objects within 36” of the fi replace front.
BE CAREFUL not to put any decorating objects sensitive to heat to close above or around the fi replace as it gets very hot when operating.
The glass door assembly MUST be in place and sealed before the unit can be placed into safe operation.
DO NOT OPERATE this appliance with the glass door removed, cracked, or broken. Replacement of the glass door should be performed by a licensed or qualifi ed service person. DO NOT strike or slam the glass door.
The glass door assembly SHALL ONLY be replaced as a complete unit, as supplied by the fi replace manufacturer. NO SUBSTITUTE material may be used.
DO NOT USE abrasive cleaners on the glass door assembly. DO NOT ATTEMPT to clean the glass door when it is hot.
A BARRIER DESIGNED TO REDUCE THE RISK OF BURNS from the hot viewing glass is provided with this appliance and SHALL BE INSTALLED for the
PROTECTION OF CHILDREN and other AT-RISK INDIVIDUALS.
If the barrier becomes damaged, the barrier SHALL BE REPLACED with the MANUFACTURER’S BARRIER
for this appliance.
Any safety screen, guard or barrier removed for ser­vicing the appliance, MUST BE REPLACED prior to operating the appliance.
Children and adults should be ALERTED to the hazards of high surface temperature and should STAY AWAY to avoid burns or clothing ignition.
YOUNG CHILDREN should be CAREFULLY SUPERVISED when they are in the same room as the
appliance. Toddlers, young children and others may be susceptible to ACCIDENTAL CONTACT BURNS. A physical barrier is recommended if there are at-risk individuals in the house. To restrict access to a fi replace or stove, INSTALL AN ADJUSTABLE SAFETY GATE to keep toddlers, young children and other at-risk individuals out of the room and away from hot surfaces.
3
Safety and Your Fireplace
!
Safety and Your Fireplace
Please Read and Carefully Follow all Safety Warnings and Operating Instructions Contained in Your Owner’s Manual
(Replacement Manuals are available by contacting our service department at 1-800-468-2567 or visit www.valorfi replaces.com).
Please Follow These Important Child Safety Precautions and Recommendations,
Parts of your Valor Fireplace become
extremely hot while in operation.
The glass viewing window
temperature can exceed 500 F
at full capacity. Momentary contact with a hot glass surface can cause a severe burn, even if the fi replace is operating at reduced heating capacity.
withdraw in the event of accidental contact with a hot surface.
A physical barrier is strongly
recommended if there are young children, or at-risk individuals in the house. Install an approved after­market safety gate to keep toddlers, young children and other at-risk individuals a safe distance from the replace.
Keep the remote control handset
out of reach of children at all times. A wall mount storage holster
is provided with your remote control handset.
The glass window will remain hot
for an extended period of time after the fi replace has been turned off. Ensure that children are prevented from touching the fi replace during the cool down period.
Toddlers and Young Children
must be closely supervised at all times when they are in the same
room as the operating fi replace. They lack full awareness of danger and rely on your protection. Toddlers, in particular, do not have the motor skills and response refl exes to
4
Ensure that the fi replace, including
the pilot light, is completely turned off when children are present and
close supervision and safety barriers are not available—see page 8 of
Owner’s Information section.
If the fi replace is not going to be used
for the summer or any extended period of time, remove the batteries
from the remote control handset and receiver. It is recommended that
batteries are replaced annually in any event—see page 7.
Owner’s Information
• • Some materials or items, although safe, may discolor, shrink, warp, crack, peel, and so on because of the heat produced by the fi replace.
AVOID PLACING
candles, paintings, photos,
and other items
SENSITIVE TO HEAT
OWNER’S INFORMATION
WARNING
!
EXTREMELY HOT!!!
READ the SAFETY information on pages 3 and 4 of this manual BEFORE operating your gas heater.
• Some parts of your replace are EXTREMELY HOT, particularly the GLASS window.
DO NOT LET CHILDREN touch the glass or any parts of your fi replace even after it is turned off as it is still hot.
USE THE SAFETY SCREEN provided with the front or trim or a GATE to reduce the risk of burns.
• Keep the remote control handset OUT OF REACH of children.
HOT HEARTH / FLOOR! The hearth or fl oor in front of the fi replace may become very hot when the fi replace heats. Do not use the hearth as a seat or shelf.
Some materials or items, although safe, may discolor, shrink, warp, crack, peel, and so on because of the heat produced by the fi replace.
AVOID PLACING
and other items 36 inches (0.9 m) around the fi replace.
candles, paintings, photos,
SENSITIVE TO HEAT within
Thank You ...
For purchasing a Valor by Miles Industries. Your new radiant gas heater is a technical appliance that must be installed by a qualifi ed dealer. Each Valor fi replace is fully tested during the production process for your safety and comfort. Your unit has been professionally installed by:
Dealer Name: ________________________________
Phone Number :_______________________________
Should you encounter an operational problem, call your dealer immediately.
Do not try to repair the unit as you may cause an injury or damage the fi replace.
This manual and particularly the preceding and following pages contain very important information regarding the safe operation of your replace as well as maintenance instructions.
Read carefully BEFORE operating your fi replace and pay special attention to the SAFETY WARNINGS.
A heating gas appliance does require safe handling and for this reason, we very strongly recommend that no children be allowed to touch the fi replace and its controls at all times. Do install a screen or barrier
in front of the fi replace to protect your children against severe burns.
• Solid wood fl ooring in front of the fi replace (if allowed) may shrink during the heating season due to heat.
Performance of LPG appliances may be affected by the quality of commercial gas supplied in your area.
Fireplace
Hearth
Do not put
furniture or other objects
in this space in front of
the replace:
36” (0.9 m)
Operating Your Fireplace for the First Time
When operating your new fi replace for the fi rst time, some vapors may be released due to the burning of curing compounds used in the manufacture of the appliance. They may cause a slight odor and could cause the fl ames to be the full height of the fi rebox, or even slightly higher, for the fi rst few hours of operation.
It is also possible that these vapors could set off any smoke detection alarms in the immediate vicinity. These vapors are quite normal on new appliances. We recommend opening a window to vent the room. After a few hours use, the vapors will have disappeared and the fl ames will be at their normal height.
Flame Supervision Device
For your safety, this appliance is fi tted with a fl ame supervision device which will shut-off the gas supply if, for any reason, the pilot fl ame goes out. This device incorporates a fi xed probe, which senses the heat from the pilot fl ame. If the probe is cool, the device will prevent any gas fl ow unless manually lighting the pilot. See full lighting instructions on page 14 of this manual.
5
OWNER’S INFORMATION
Owner’s Information
Cleaning Your Fireplace
WARNING
!
DO NOT TOUCH THE GLASS WHILE IT IS HOT!
Let the fi replace cool fi rst before cleaning it.
Important - Glass cleaning - Mineral deposits
One of the by-products of the combustion process in a gas appliance is a mineral which can show up as a white fi lm on the ceramic glass of the viewing door.
The composition of the deposit varies with location and time. It is believed to be associated with the varying sulfur content of the gas. You may have the problem intermittently.
We have consulted with ceramic glass manufacturers and they cannot offer a defi nitive solution to this prob- lem. Dealers have tried various cleaning products with varying results. The following are recommendations only and are not meant to guarantee results.
NOTE: This is a problem beyond Miles Industries’ control and is not covered under warranty.
• Clean the glass regularly as soon as you notice
the buildup (white fi lm). If the fi lm is left for a longer period of time, it will etch into the glass. It is then much harder, if not impossible, to remove.
• NEVER use an abrasive cleaner on the ceramic glass. Any abrasion of the surface has the
immediate effect of compromising the strength of the glass. An emulsion type cleaner is recommended.
• Use a soft damp cloth to apply the cleaner. Dry the glass with a soft, dry, preferably cotton cloth. Most paper towels and synthetic materials are abrasive to ceramic glass and should be avoided.
• Our dealers have had good results from the products listed below. We cannot, however, guarantee the results of these products.
Brasso, Polish Plus by Kelkem, Cook Top Clean
Creme by Elco, White Off by Rutland, Turtle Wax
Do not clean the glass while it is hot!
Always securely replace the window and the barrier screen before lighting.
If broken, the glass pane may only be replaced as a complete window unit as supplied by the manufacturer.
To remove the window for cleaning:
1. Unhook the front and barrier screen.
2. Release the top of the window by pulling forward and rotating outwards the two bars at the top corners.
3. Unscrew the two spring-loaded bolts securing the bottom of the window.
4. Carefully lift the window. Keep the window and bolts in a safe place.
Clean the window following the guidelines in this section. Clean the trim or front with mild soap and water.
Dust the barrier screen with a soft brush. Dust the fi rebox ceramic logs/rocks and walls with a
soft brush. Dust can also be removed from the burner using a soft brush after removing the ceramic logs.
When cleaning, make sure that no particles are brushed into the slots of the burner.
To refi t the window:
1. Place the window centrally against the engine unit resting it on the support at bottom front of the engine.
2. Pull the clamping bars forward and rotate inwards to secure the top of the window.
3. Fit the two spring loaded bolts through the bottom of the window and tighten to secure the bottom of the window.
4. Pull the top of the window forward and release to ensure the springs return it in position.
5. Similarly check the bottom of the window by pulling it forward and releasing.
IMPORTANT: To ensure a safe operation, ensure that the spring-loaded mechanism functions properly.
6. Apply light hand pressure against the window frame sides to bed in the window seal.
If the barrier becomes damaged, the barrier shall be replaced with the manufacturer’s barrier for this appliance.
6
Owner’s Information
OWNER’S INFORMATION
7. If the Hot Glass Warning plate has been removed
from the front lower corner of the window, reinstall it by sliding it between the glass and the frame as indicated.
Safety warning plate
8. Reinstall the front and barrier screen.
WARNING
!
FOR SAFETY PURPOSE, ensure the barrier screen is re-installed on the fi replace front after maintenance.
Checking Pilot and Burner Flames
A periodic check of the pilot and burner fl ames should be made. Check after the fi re has been on for at least 30 minutes. The pilot fl ame must cover the tip of the thermocouple probe. The main burner fl ame pattern will vary from appliance to appliance depending on the type of installation and climatic conditions.
With Logs
With Rocks
Correct fl ame appearance
With Coals
Thermocouple probe must be in flame
The appliance area must always be kept clear and free from combustible materials, gasoline and other ammable vapors and liquids. Inspect the vent terminal outdoors regularly to make sure that dirt, snow, insects, leaves, shrubs, trees do not obstruct it. Examine the whole vent system regularly. We recommend annually.
Using Handset Wall Holder
Your fi replace equipment includes a wall holder to store the handset. If it hasn’t be installed, refer to the instructions further on in this manual for the installation.
Replacing Batteries
Low battery signal: see page 13.
WARNING
!
DO NOT ATTEMPT TO CHANGE THE BATTER­IES WHILE THE FIREPLACE IS STILL HOT! Let
the fi replace cool fi rst before touching it.
CAUTION
DO NOT USE a screwdriver or other metallic object to
remove the batteries from the receiver or the handset! This could cause a short circuit to the receiver.
BEFORE changing the batteries, turn off the valve using the manual On/Off switch —see instructions on
next page.
The appliance uses four 1.5 V AA alkaline batteries for its remote control receiver and one 9 V alkaline battery for its handset. The batteries should last one to two seasons, depending on usage. Removing the batteries in the off-season will extend the battery life. Should the batteries loose power, the control may be operated by manually turning the control knob at the valve or by turning off the valve at the switch.
To replace the batteries in the remote control receiver:
1. The receiver is located to the left of the valve and it
is retained to the fi rebox by a Velcro tab. Grab the
receiver and pull it out from its location.
2. Slide and remove the receiver cover.
3. Replace batteries with 4 AA alkaline batteries.
4. Replace the cover.
5. Put the receiver back in its position pushing it in so
it attaches to the Velcro tab.
7
Valve Switch
OWNER’S INFORMATION
Owner’s Information
Locating Lighting, Operation and Rating Information Plate
WARNING
!
DO NOT ATTEMPT TO TOUCH THE DATA PLATE WHILE THE FIREPLACE IS STILL HOT! Let the
replace cool fi rst before touching it.
The Lighting, Operation and Rating information is located on a plate under the fi rebox.
To access the plate, remove any fret or access panel and grab the plate and slide it out to read it. There is important information on both sides of the plate.
Servicing Your Fireplace
If your appliance require any attention, contact your supplier quoting the model number. It will be helpful if the appliance serial number can also be quoted. This is on the rating plate located under the fi rebox. The repair parts are shown in the separate repair parts leafl et. Please always quote part number and description when requesting spare parts.
Operating Your Fireplace
There are three ways to control your fi replace.
1. Thermostatic Remote Control;
2. Manual On/Off Switch;
3. Wall Switch (optional) .
The Thermostatic Remote Control can be programmed to function automatically—see pages 9–13.
The manual On/Off switch must be ON for the fi replace to function. It can be used to shut off the fi replace in case of emergency—see above.
The Wall Switch (optional) can be used to turn on, off and to increase or decrease the fl ame height—see 1265WSK—Wall Switch Kit.
NOTE: The remote control in the AUTO mode will override the wall switch.
ON
OFF
Thermostatic Remote
Control
Wall Switch
(optional)
Manual On/Off Switch
How to Turn Your Fireplace OFF (including pilot)
Familiarize yourself with each of these methods before operating your fi replace.
Handset and Wall Switch: Press and hold the OFF button for a second (either on the handset or the wall switch).
If the fl ames are on, they go down and you hear the valve motor wind down. You hear a clunk and a beep indicating that the valve has received the signal from the remote control.
Remote control
handset
Wall Switch
(optional)
Manual ON/OFF Switch: Press the O button.
O
ON
OFF
O
How to Ensure Your Fireplace Cannot Be Turned ON Inadvertently
You can use one of the two following methods to ensure that your fi replace will not turn on when you don’t want it on.
First, ensure your fi replace is turned off—including the pilot—and cold BEFORE going ahead.
• You can prevent your fi replace from lighting by pressing the O button on the manual ON/OFF switch on the gas valve—see image above.
• Alternately, you can remove all batteries from the receiver as well as the battery from the handset.
Automatic Shut-Off (in certain conditions)
Your fi replace’s remote control is equipped with an automatic shut-off mechanism which is activated in
certain conditions. See page 13 in the Remote Control Operation section for a description of this feature.
8
Remote Control Operation
Current
temperature
(F or C)
Current time (12 or 24 hour clock)
Modes (Manual, Temperature, Timer)
Handset sensor
Battery status
Current
programmed
period (Timer)
Period
start or end
(Temp, Timer)
OWNER’S INFORMATION
NOTE: Before using the remote control system for the fi rst time, the receiver and the handset must
be synchronized. See the sub-section Set-up Remote Control on page 37 of this manual.
Display Overview
Note: In the TEMP or TIMER modes, the remote handset senses the room temperature and adjusts the ame accordingly.
To communicate, the handset should be within 15 feet (4.5 meters) of the fi replace.
Do not leave the handset on the mantel or hearth.
IMPORTANT: BEFORE YOU BEGIN, please note that on this system, the settings of time, temperature and automatic ON/OFF can only be programmed when the function display is ashing. Be patient when programming as it can take a few seconds to set.
Large ame
Set (scrolls
through
modes and
settings)
OFF (returns
to set mode,
turns the burner
and the pilot o)
Handset Overview
button (ames up, sets hours, temperature)
Small ame button (ames down and o, sets minutes, temperature)
TO TURN ON APPLIANCE TO TURN OFF APPLIANCE
CAUTION
When pilot ignition is confi rmed, motor turns automatically to maximum fl ame height.
• On the valve, turn MAN knob on the ON, full counterclockwise position.
• Place ON/OFF switch (if equipped) in I (ON position).
• Simultaneously press the OFF and
(large fl ame) buttons until a short beep confi rms the start sequence has begun; release buttons.
• Continuing beeps confi rm the
ignition is in process.
• Once pilot ignition is confi rmed, there is main gas fl ow.
• After main burner ignition the
handset will automatically go into manual (MAN) control mode.
• Press OFF button.
When the pilot is off, it will take 2
When the pilot is off, it will take 2
minutes before it can be lit again.
minutes before it can be lit again.
STANDBY MODE (Pilot Flame)
• Press and hold (small fl ame) to set appliance at pilot fl ame.
FLAME HEIGHT ADJUSTMENT
• In standby mode: Press and hold
(large fl ame) button to increase ame height.
9
OWNER’S INFORMATION
Remote Control Operation
• Press and hold (small fl ame) button to decrease fl ame height or to set the appliance at pilot fl ame.
• For fi ne adjustment tap the (large fl ame) or (small fl ame) buttons.
Express Low and High Fire
• Double-click (small fl ame) button. “LO” will be displayed. NOTE: Flame goes to high fi re fi rst before going to designated low fi re.
x 2
• Double-click (large fl ame) button. Flame automatically goes to high fi re. “HI” will be displayed.
x 2
SETTING ºC/24-HOUR OR ºF/12-HOUR CLOCK
• In MAN mode, press OFF and (small fl ame) buttons until display changes from Fahrenheit/12-hour clock to Celsius/24-hour clock and vice versa.
SETTING THE TIME
• The time display will fl ash after either:
Installing the battery or
Simultaneously pressing the
(large fl ame) and (small fl ame) buttons.
• Press (large fl ame) button to set the hour.
• Press (small fl ame) button to set the minute.
• Press OFF or simply wait to return to MAN mode.
MODES OF OPERATION
• Briefl y pressing the SET button
changes the mode of operation in the following order:
MAN
TIMER
→ → and back to .
TEMP
TEMP
MAN
NOTE: Manual mode can also be reached by pressing
either the (large fl ame) or the (small ame) buttons.
MAN
- Manual Mode - Manual Flame Height Adjustment.
TEMP
- Daytime Tempera- ture Mode (Appliance must be in
standby mode; pilot ignited) - The room temperature is measured and compared to the set temperature. The fl ame height is then auto- matically adjusted to achieve the Daytime Set Temperature.
TEMP
- Nighttime Setback Temperature Mode (Appliance
must be in standby mode; pilot ignited) - The room temperature is measured and compared to the Nighttime Setback temperature. The fl ame height is then automati- cally adjusted to achieve the Night­time Setback Temperature.
TIMER
- Timer Mode (Appliance must be in standby mode; pilot ignited) - The timers P1 and P2
(Program 1, Program 2) each can be programmed to go ON and OFF at specifi c times. For instructions see Timer Programming Mode.
NOTE: The display shows the set temperature every
30 seconds.
10
Remote Control Operation
SETTING THE ON / OFF TEMPERATURES
SETTING THE “DAYTIME” TEMPERATURE
Default Settings: (sun), 23ºC / 74ºF
TEMP
OWNER’S INFORMATION
SETTING THE “NIGHTTIME SETBACK” TEMPERA­TURE
Default Settings: (moon),--” (OFF)
TEMP
• Briefl y press SET button to scroll to
TEMP (sun) mode. Hold
TEMP
the SET button until the TEMP ashes.
• Press (large fl ame) button
to increase the Daytime Set Temperature.
• Press (small fl ame) button
to decrease Daytime Set Temperature.
• Briefl y press SET button to scroll to
TEMP (moon) mode. Hold
TEMP
the SET button until the TEMP ashes.
• Press (large fl ame) button to
increase Nighttime Setback Temperature.
• Press (small fl ame) button to
decrease Nighttime Setback Temperature.
• Press OFF or simply wait to complete programming.
• Press OFF or simply wait to complete programming.
Tip
Set the different parameters when they are fl ashing.
11
OWNER’S INFORMATION
Remote Control Operation
SETTING PROGRAM TIMERS
• You can program two periods of time between 12:00 am and 11:50 pm in each 24-hour cycle.
• The Programs P1 and P2 must be set in the following order during a 24-hour cycle: , ,
P2
and .
• The icon indicates the beginning of the period (ON) and the icon indicates the end of the period (OFF).
P1
• If = or = , the programming is cancelled.
• To keep the fi replace ON all night, set at 11:50 am and at 12:00 am.
P1
P2
P1
P2
P2
P1
P2
P1
Default settings:
Program 1: 6:00 am 8:00 am Program 2: 11:50 pm 11:50 pm
P1
P2
• Briefl y press SET button to scroll to
TIMER mode.
P1
P2
SETTING P1 OFF TIME
• Briefl y press SET button to scroll
to TIMER (moon) while the time fl ashes.
• Press (large fl ame) button to set
the hour.
• Press (small fl ame) button to
set the minutes.
P1
SETTING P1 ON TIME
• Hold the SET button until (sun) is displayed and the time ashes.
• Press (large fl ame) button to set the hour.
• Press (small fl ame) button to set the minutes.
P1
SETTING P2 ON TIME
• Briefl y press SET to scroll to TIMER mode (sun) while the time fl ashes.
• Follow the instructions given to set P1 ON time.
P2
SETTING P2 OFF TIME
• Briefl y press SET to scroll to TIMER mode (moon) while the time fl ashes.
• Follow the instructions given to set P1 OFF time.
Press OFF button to save these settings. The timers are programmed. See the diagram on programming sequences on the following page.
P2
Tip
If you want to program only one period, program and with desired times and program and
P1
P2
with the same time as .
P1
P1
P2
12
Remote Control Operation
Timer Programming Example (default temperatures shown)
OWNER’S INFORMATION
6:00 a.m.— P1
Start time
Set temp 74˚F Set temp 40˚FSet temp 74˚F
AUTOMATIC TURN DOWN
No communication. If there is no communication between the receiver and the handset for a period of 6 hours, the appliance goes into pilot mode.
No change in ame height. If there is no change in fl ame height for a period of 6 hours, the appliance goes into pilot mode. NOTE: In TEMP or TIMER modes, the fl ame height will vary according to room temperature. The appli­ance will continue to work normally. However, if the room temperature remains the same for 6 hours, the appliance will go into pilot mode.
AUTOMATIC SHUT OFF
Low batteries in the receiver. With low battery power in the receiver the system shuts off completely. NOTE: This does not apply when the power supply is interrupted.
No change in pilot. The appliance shuts off completely when it is continually in pilot position— without any change—for a period of 5 days.
8:00 a.m.— P1
End time
Set temp 40˚F
☽☽
4:00 p.m.— P2
Start time
LOW BATTERY INDICATION
DO NOT USE a screwdriver or other metallic object
to remove the batteries from the battery box or the handset! This could cause a short circuit.
Remote handset: The battery icon will show when the battery needs to be replaced. Replace with one 9 V alkaline battery.
Receiver: Three short ‘beeps’ will sound when the motor turns when the batteries need to be replaced. Replace with four 1.5 V alkaline batteries.
HANDSET / RECEIVER MATCH
The remote control handset and receiver are program­med to function together. In case of a replacement of the handset or the receiver, you will need to reset the receiver to allow them to function together. Contact your dealer for details.
10:00 p.m.— P2
End time
CAUTION
6:00 a.m.— P1
Start time
Required Kits*
Fronts (choose one)
531CSB—President Stove FS with Barrier Screen
4003288
536CXB—President ZC Front with Barrier Screen
4003359
541BPC—Bolero Front with Barrier Screen 4003289 539/549/559—Windsor and Classic Arches with Barrier
Screen 4003290
563CSB—Senator Front with Barrier Screen 4003291 569—Ledge Fronts with Barrier Screen 4003375 575-576-578—Lift Stove with Barrier Screen 4003429
Options
Optional Kits*
567FGP—Top Grille (with logs or rocks ONLY) 580EBL—Enamel Liner Kit 1265WSK—Wall Control Switch Kit 555CFK—Circulating Fan Kit
Gas Conversion Kit
530NGK—Conversion Kit LPG to NG 530PGK—Conversion Kit NG to LPG
Hearth Gate
Hearth gates such as Cardinal’s VersaGates are available at retail stores carrying safety products for children.
*Information accurate at the time of printing and subject to change without notice.
13
X
OWNER’S INFORMATION
WARNING: If you do not follow these instructions exactlyD¿UHRUH[SORVLRQPD\UHVXOWFDXVLQJ
SURSHUW\GDPDJHSHUVRQDOLQMXU\RUORVVRIOLIH
A. This appliance has a pilot which must be lighted by hand or by remote control. Follow these instructions exactly.To
save gas, turn the pilot off when not using the appliance for a prolonged period of time.
%%()25(/,*+7,1*VPHOODOODURXQGWKHDSSOLDQFHDUHDIRUJDV%HVXUHWRVPHOOQH[WWRWKHÁRRUEHFDXVHVRPHJDV
DUHKHDYLHUWKDQDLUDQGZLOOVHWWOHRQWKHÁRRr.
WHATTO DO IFYOU SMELL GAS
'RQRWWU\WROLJKWDQ\DSSOLDQFH 'RQRWWRXFKDQ\HOHFWULFVZLWFKGRQRWXVHDQ\SKRQHLQ\RXUEXLOGLQJ
,PPHGLDWHO\FDOO\RXUJDVVXSSOLHUIURPDQHLJKERr’s phone. Follow the gas supplier’s instructions. ,I\RXFDQQRWUHDFK\RXUJDVVXSSOLHrFDOOWKHÀUHGHSDUWPHQW
C. Use only your hand to push in or turn the control knobs. Never use tools. If the knobs will not push in or turn by hand,
GRQ·WWU\WRUHSDLUWKHPFDOODTXDOLÀHGVHUYLFHWHFKQLFLDQ)RUFHRUDWWHPSWHGUHSDLUPD\UHVXOWLQDÀUHRUH[SORVLRQ
D. Do not use this appliance if any part has been under water,PPHGLDWHO\FDOODTXDOLÀHGVHUYLce technician to inspect
the appliance and to replace any part of the control system and any gas control, which has been under water.
1. STOP! Read the safety information above.Dependent on model, switch #1 may be mounted directly to valve see Fig 2A.
Lighting Instructions
FOR YOUR SAFETY, READ BEFORE LIGHTING
LIGHTING INSTRUCTIONS
)LJ
2. SET ON/OFF SWITCH (1) TO “OFF” POSITION.
WDLWÀYHPLQXWHVWRFOHDURXWDQ\JDVWKHQVPHOOIRUJDVLQFOXGLQJQHDUWKHÁRRr. If you smell gas, STOP! Follow
“B” in the safety information above on this label. If you don’t smell gas, go to the next step.
3. AUTOMA7,&,*1,7,21ÀJ/RFDWHWKHSLORWÀJLQVLGHRIÀUHER[DW/HIW+DQGVLGH
212))VZLWFKLQ21SRVLWLRQ0$1NQRELQ21SRVLWLRQVHW)ODPH Adjustment knob (3) to lowest setting
(3);
On the remote control handset, press and hold the ‘off ’ button and (large flame) VLPXOWDQHRXVO\DVKRUW
DFRXVWLFVLJQDOFRQÀUPVWKHVWDUWKDVEHJXQ
)XUWKHUVKRUWDFRXVWLFVLJQDOVLQGLFDWHWKHLJQLWLRQSURFHVVLVLQSURJUHVV
When the pilot is lit, the Flame Adjustment knob (3) will automatically rotate to the highest setting.
Press the (small flame)RQWKHUHPRWHFRQWUROKDQGVHWWRUHGXFHWKHÁDPHKHLJKW
4. MANUAL,*1,7,21ÀJWLWKWKHZLQGRZRIIORFDWHWKHSLORWÀJ
LQVLGHRIÀUHER[DW/HIW+DQGVLGH
212))VZLWFKLQ21SRVLWLRQ0$1NQRELQ0$1SRVLWLRQ
Set Flame Adjustment knob (3) to the lowest setting (3);
3XVKGRZQWKHPHWDOOLFFRUHZLWKDSHQRUVLPLODULQVWUXPHQWWKLVZLOOHVWDEOLVKWKHSLORWJDVÁRZ /LJKWJDVDWWKHSLORWZLWKDPDWFK &RQWLQXHKROGLQJGRZQPHWDOFRUHIRUDERXWVHFRQGVDIWHUUHOHDVHSLORWVKRXOGUHPDLQOLW
5HLQVWDOOWKHZLQGRZDQGVHWWKH0$1NQREWR´21µWXUQ)ODPH Adjustment knob (3) up (4) or down
manually or use the up/down ‘flame’ buttons on the remote control handset to adjust theÁDPHKHLJKW
If the pilot will not stay lit after several tries, turn the gas control knob (3) to “OFF” (3) and call your local service technician or gas supplier.
)LJ
)LJ$
TO TURN OFF GAS TO APPLIANCE
1. AUTOMATIC SHUT2))XVLQJWKHUHPRWHFRQWUROKDQGVHW
Press and hold the (small flame) RQWKHUHPRWHFRQWUROKDQGVHWWRVKXWRIIWKHPDLQEXUQHUJDVÁRZ
3UHVV´2))µEXWWRQRQUHPRWHKDQGVHWWRVKXWRIIWKHDSSOLDQFHLQFOXGLQJSLORWÁDPH
2. MANUAL SHUT-OFF (using only the ON/OFF switch (1)) Press “O” the ON/OFF switch (1) to shut-off the appliance.
)LJ
14
Commonwealth of Massachusetts
QUALIFIED INSTALLER
State of Massachusetts Carbon Monoxide Detector/Vent Terminal Signage Requirements
For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above nished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfi ed:
1. INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber or gas fi tter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the fl oor level where the gas equipment is to be installed. In addition, the installing plumber or gas fi tter shall observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualifi ed licensed professionals for the installation of hard wired carbon monoxide detectors.
3. SIGNAGE. A metal or plastic identifi cation plate shall be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign shall read, in print size no less than one-half (1/2) inch in size, “GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS”.
4. INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.08(2)(a)1 through 4.
(b) EXEMPTIONS: The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4:
1. The equipment listed in Chapter 10 entitled “Equipment Not Required To Be Vented” in the most current edition of NFPA 54 as adopted by the Board; and
2. Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or structure used in whole or in part for residential purposes.
a. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent fl oor level.
b. In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed.
2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certifi ed.
(c) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM PROVIDED. When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by the manufacturer for installation of the equipment and the venting system shall include:
1. Detailed instructions for the installation of the venting system design or the venting system components; and
2. A complete parts list for the venting system design or venting system.
15
Loading...
+ 33 hidden pages