INSTALLATION MANUAL
H5 Series
1135TSBE Three Sided Trim with Edgemont Front
Use with Valor 1100 & 1150 Models only
!
DANGER
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
INSTALLER
Leave this manual
with the appliance.
CONSUMER
Retain this manual
A barrier designed to reduce the risk of burns from the hot
viewing glass is provided with this appliance and shall be
installed for the protection of children and other at-risk
individuals.
The 1135TSBE trim is intended to be used on Valor heaters models 1100 & 1150. Mounting of the 1135TSBE does
not aff ect clearances or other specifi cations listed in the appliance installation manuals—see installation manual
supplied with the appliance for more information.
Note: Mounting of this trim allows for non-combustible
material up to 3/4” (19 mm) thick installed over top of the
required 1/2” (13 mm) cement board. For thicker fi nishes,
refer to appliance manual.
for future reference.
1100 or 1150 engine
41-7/8” (1063 mm)
4004430-05
© Copyright Miles Industries Ltd., 2018
31-7/8” (811 mm)
Overview
Convection baffl e
LH door
RH door
Removable panel
Backing plate
assembly
Edgemont barrier screen
Installation
1. On completion of fi replace installation, fi t the convection baffl e to top face of fi rebox with 3 screws.
3. Slide the removable panel in the clip on the
horizontal supports on each side and push it in until
fl ush with the front trim.
2. Carefully position and secure backing plate with 4
low profi le screws to 4 fi rebox mounting brackets;
before tightening, hold plate up against wall fi nish
then tighten.
4. Adjust the position of the convection brackets on
each side of the window. Release the nut, pull the
bracket as forward as possible and tighten the nut.
5. Identify left hand door from right using diagram
below.
2
Bottom of
locator tabs
have hook
LH Door RH Door
nger grip inboard,
with locator on left
nger grip inboard,
with locator on right