Vallox 1992 A EK Instructions For Installation And Use Manual

Page 1
1
Rocker switch pressed
• right edge down, on
• left edge down, off
Ventilation switch
NOTE! Carefully push the tongues inwards.
In flush mounting, maximum installation depth is 55 mm.
Surface mounting box
Instrument box
Room by room ventilation system
In buildings with room by room ventilation the user can influence the level of ventilation. Ventilation can be adjusted in accordance with usage with the ventilation regulator.
Normal operation (position 2 or 3)
Ventilation has to be continual, i.e. air volume in the dwelling has to be exchanged at least every two and a half hours.
Absence operation (position 1)
When the room is empty, ventilation can be adjusted lower than the normal operation position unless it is harmful for the building structures or ventilation system.
Boosted operation (positions 3 and 4)
Cooking, bathing in the sauna or bathroom, drying clo­thes, using the toilet, having guests, overheat or a simi­lar situation in dwellings may cause a need for higher than normal ventilation. In other rooms, ventilation is boosted in accordance with the usage of the room.
© VALLOX • We reserve the right to make changes without prior notification. www.vallox.com
SEPARATE CONTROL CENTRE EK
INSTRUCTIONS FOR INSTALLATION AND USE
Installation
EK
55
140
90
110
1. Open the front panel of the control centre with e.g. a screwdriver.
2. Mark the locations for the fixing screws.
3. Fasten the control panel to the wall with the fixing accessories provided in the kit. (Fixing screws are suitable for wooden, chipboard, concrete and masonry walls; for other surfaces, use appropriate fixing accessories.)
Operating switches of the control centre:
If ventilation of a room is closed, it also prevents new, clean outdoor air from coming in to the house and dirty air from going out. Impurities emanating from human bodies, structures and the soil, such as carbon dioxide, humidity, smells, formaldehyde, dust and radon, quickly spoil indoor air and cause health damage. Therefore, the building regulations require ventilation to be continually in operation and the level of ventilation to be adjusted as needed by the user.
WARNING
2
For instance in dwellings
1. Absence position
2. Normal position
3. Boost position
4. Peak boost position
1 Ventilation regulator
NOTE! Electrical connections must be carried out by an authorised person only. In case of failure with the control centre, contact the seller or
manufacturer of the device.
NOTE! In fans that are controlled with the control panel, a
motor protector is needed. The maximum output of the fan is 340 W. Follow the ventilation plan that states the position of
the regulator in normal living conditions in order to ensure proper air circulation.
2
1
86
48
86
• 1.09.341E
• 25.1.2008 © VALLOX
Page 2
© VALLOX • We reserve the right to make changes without prior notification.
L
N
W2
U2V1V2
U1
W1
VALLOX 15P-2-1 VALLOX 20P-2-1 VALLOX 22P-2-1
L2
N
VALLOX 25P-4-1
L2 N
3*1.5 S
3*1.5 S
N
L2
N
3*1.5 S
L2
N
L
N
PE
2
1
3
4
1
2
3
4
CAM SWITCH factory mounting
b
3*1.5 S
10A
5*1.5
1
2
3
L
3
L
N
N
L
2
4
VALLOX 70
N
L1
PE
N
L
10A
PE
N
L
L3
L3
VALLOX 75/95
L2 N
L
L
N
N
1
L
L2
N
L
L
5*1.5 S
N
5*1.5 S
10A
L
LN
3*1.5 S
3*1.5 S
L3 L2
N
2
1
3
4
1
2
3
4
CAM SWITCH factory mounting
b
5*1.5
1
2
3
L
3
L
LNNL
2
4
ROOF VENTIILATORS:
ROOF VENTILATOR
DISTRIBUTION PANEL
CONTROL CENTRE VALLOX 1992 A EK
ATTIC FAN
CONTROL CENTRE VALLOX 1992 A EK
DISTRIBUTION PANEL
DISTRIBUTION PANEL
1.09341E/25.1.2008/PDF
123
L
3
L
N
N
L
2
4
N
M
120 V
90 V
70 V
230 V
135 V 160 V 180 V
110 V
www.vallox.com
Vallox Oy FIN-32200 Loimaa Finland Telephone +358 2 7636 300 Fax +358 2 7631 539
www.vallox.com.
CONTROL CENTRE 1992 A EK
ELECTRICAL DIAGRAMS
Internal electrical connection / Control centre VALLOX 1992 A EK
External electrical coupling / Distribution panel – ventilation unit – control centre
External electrical coupling / Distribution panel – control centre – powered roof ventilator